Pengembangan dan Validasi Metode Analisis Favipiravir dan Remdesivir dalam Volumetric Absorptive Microsampling dengan Kromatografi Cair Kinerja Ultra Tinggi Tandem Spektrofotometri Massa = Development and Validation of Methods for Analysis of Favipiravir and Remdesivir in Volumetric Absorptive Microsampling with Ultra High Performance Liquid Chromatography Tandem Mass Spectrophotometry

Roesyta’s Fitria Noer; Harahap, Yahdiana, supervisor; Hayun, examiner; Maggadani, Baitha Palanggatan, examiner; Ratika Rahmasari, examiner (Fakultas Farmasi Universitas Indonesia, 2021)

 Abstrak

Favipiravir dan remdesivir adalah obat-obatan yang digunakan untuk pengobatan COVID-19. Favipiravir berperan sebagai antivirus dengan menghambat enzim RNA-dependen RNA polimerase sementara remdesivir dimetabolisme menjadi metabolitnya GS-441524 atau remdesvir trifosfat (RDV-TP) sehingga menjadi ligan menyerupai ATP sehingga dapat mengakhiri sintesis RNA virus. Sebelumnya, telah dikembangkan dan divalidasi metode analisis favipiravir dan remdesivir namun dengan matriks plasma. Penelitian ini bertujuan untuk menemukan metode yang optimal dan tervalidasi untuk analisis favipiravir dan remdesivir secara simultan dalam Volumetric Absorptive Microsampling (VAMS). Penggunaan VAMS dapat menjadi salah satu keuntungan karena volume darah yang diambil sedikit dan proses pengambilan darah hanya melalui teknik finger prick, sehingga dapat dilakukan oleh pasien sendiri. Hal ini dapat mengurangi proses penularan virus. Preparasi sampel dengan VAMS dilakukan dengan pengendapan protein menggunakan metanol sebanyak 500 µl. Analisis dilakukan dengan kromatografi cair kinerja ultra tinggi dengan detektor spektrofotometri massa dan electrospray ionization positif dan multiple reaction monitoring dengan m/z 157,9 > 112,92 untuk favipiravir dan 603,09 > 200,005 unuk remdesivir dan pada m/z 225,968 > 151,991 untuk asiklovir sebagai baku dalam. Pemisahan dilakukan dengan kolom Acquity UPLC BEH C18 (100 x 2,1 mm; 1,7 µm), fase gerak asam format 0,2%-asetonitril (50:50), laju alir 0,15 ml/menit, dan suhu kolom 50oC. Metode analisis telah tervalidasi sesuai dengan persyaratan yang dikeluarkan oleh Food and Drug Administration (2018) dan European Medicines Agency (2011). Nilai LLOQ yang didapatkan untuk favipiravir adalah 500 ng/ml dengan rentang konsentrasi 500-160.000 ng/ml dan LLOQ remdesivir adalah 2 ng/ml dengan rentang konsentrasi 2-8.000 ng/ml.

Favipiravir and remdesivir are drugs to treat COVID-19. Favipiravir acts as an antiviral by inhibiting the RNA-dependent RNA polymerase enzyme while remdesivir is metabolized to its metabolite GS-441524 or remdesvir triphosphate (RDV-TP) so that it becomes an ATP-like ligand that can terminate viral RNA synthesis. Previously, a method of analysis of favipiravir and remdesivir has been developed and validated but with a plasma matrix. This study aims to find an optimal and validated method for simultaneous analysis of favipiravir and remdesivir in Volumetric Absorptive Microsampling (VAMS). The use of VAMS can be an advantage because the volume of blood drawn is small and the blood collection process is only through finger prick technique, so that it can be done by the patient. This can reduce the process of transmitting the virus. Sample preparation with VAMS was carried out by precipitation of protein using 500 µl of methanol. Analysis was carried out by ultra high-performance liquid chromatography with mass spectrophotometry detector and positive electrospray ionization and multiple reaction monitoring with m/z 157.9 > 112.92 for favipiravir and 603.09 > 200.005 for remdesivir and at m/z 225.968 > 151.991 for acyclovir as the internal standard. The separation was carried out using an Acquity UPLC BEH C18 column (100 x 2.1 mm; 1.7 m), formic acid 0.2%-acetonitrile (50:50), flow rate 0.15 ml/min, and column temperature. 50oC. The analytical method has been validated in accordance with the requirements issued by the Food and Drug Administration (2018) and European Medicine Agency (2011). The LLOQ value obtained for favipiravir was 500 ng/ml with a concentration range of 500-160,000 ng/ml and the LLOQ for remdesivir was 2 ng/ml with a concentration range of 2-8,000 ng/ml.

 File Digital: 1

Shelf
 S-Roesytas Fitria Noer.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Farmasi Universitas Indonesia, 2021
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xix, 84 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-pdf 14-25-05473829 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920556311
Cover