UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Pengujian dan Analisa Performansi Solar Charge Controller pada Sistem Pompa Air berbasis Energi Surya = Testing and Analysis of Solar Charge Controller Performance on Solar Energy-Based Water Pump Systems

Muhammad Daffa Athaya; Tomy Abuzairi, supervisor; Nji Raden Poespawati, examiner; Purnomo Sidi Priambodo, examiner (Fakultas Teknik Universitas Indonesia, 2025)

 Abstrak

Penelitian ini bertujuan untuk menguji dan menganalisis performa sebuah prototipe Solar Charge Controller (SCC) tipe MPPT saat diintegrasikan dalam sistem Pembangkit Listrik Tenaga Surya (PLTS) untuk menyuplai beban pompa air AC. Pengujian ini dilakukan berbagai skenario untuk mengkarakterisasi kinerja setiap komponen dan sistem secara terintegrasi. Hasil pengujian menunjukkan prototipe SCC memiliki efisiensi konversi daya rata-rata yang tinggi sebesar 91,7%, namun dengan keterbatasan teknis pada tegangan output maksimal 50V yang menghambat pengisian baterai secara optimal. Inverter terbukti andal dengan efisiensi stabil di kisaran 85% dan mampu menangani arus start pompa sebesar 17,4A. Pada uji sistem keseluruhan, sistem mampu beroperasi dalam mode hibrida, di mana baterai secara efektif menopang mayoritas beban saat daya dari panel surya tidak mencukupi. Prototipe SCC berfungsi efisien dalam konversi daya, namun keterbatasannya menjadi kendala signifikan untuk kesehatan baterai jangka panjang, sementara sistem secara keseluruhan menunjukkan kemampuan pembagian daya yang andal untuk menjamin operasional beban.

This research aims to test and analyze the performance of a prototype MPPT-type Solar Charge Controller (SCC) when integrated into a Photovoltaic (PV) system to supply an AC water pump load. The testing was conducted in various scenarios to characterize the performance of each component and the integrated system. The test results show that the SCC prototype has a high average power conversion efficiency of 91.7%, but with a technical limitation of a 50V maximum output voltage, which hinders optimal battery charging. The inverter proved to be reliable with a stable efficiency in the range of 85% and was capable of handling the pump's inrush current of 17.4A. In the overall system test, the system was able to operate in a hybrid mode, where the battery effectively supported the majority of the load when solar power was insufficient. The SCC prototype functions efficiently in power conversion, but its limitations pose a significant constraint to long-term battery health, while the system as a whole demonstrates reliable power-sharing capability to ensure load operation.

 File Digital: 1

Shelf
 S-Muhammad Daffa Athaya.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2025
Bahasa : ind
Sumber Pengatalogan : LIbUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xii, 42 pages : illustration