Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 163006 dokumen yang sesuai dengan query
cover
Joko Suryana
"Dalam paper ini akan dipaparkan langkah-langkah desain dan realisasi tranceiver SFGPR pada frekwensi kerja 1- 2 GHz untuk aplikasi deteksi logam dalam tanah. Sebelum prototip SFGPR diuji, dilakukan proses kalibrasi hubungan langsung untuk kalibrasi fasa dan pulsa monocycle. Setelah proses kalibrasi selesai, prototip SFGPR (Stepped Frequency Ground Penetrating Radar) ini kemudian diuji untuk mendeteksi silinder logam yang ditanam pada kedalaman 5 cm dibawah tanah dalam suatu kotak tanah nonhomogen berukuran 25 cm x 75 cm x 10 cm. Dari hasil kalibrasi dan uji deteksi silinder logam diperoleh kesimpulan bahwa, prototip SFGPR dapat bekerja dengan baik sesuai spesifikasi yang telah ditetapkan.

Design and Implementation of 1-2 GHz Stepped Frequency GPR for Buried Metal Detection. In this paper, we describe the design and realization steps of 1 ? 2 GHz SFGPR (Stepped Frequency Ground Penetrating Radar) transceiver for metal detection under the ground. Before using prototyped GPR for detecting the metal under the ground, several of calibration processes must be performed, namely phase calibration and monocycle pulse waveform calibration. After completing the calibrations, this prototyped GPR would be ready for detecting a hidden object such as a metal plate 5 cm under the ground in our small test range size 25 cm x 75 cm x 10 cm. From the calibration and detection results, we concluded that the prototyped SFGPR passed the technical specifications of the design and could perform the metal detection under the ground with high SNR."
Depok: Lembaga Penelitian Universitas Indonesia, 2005
AJ-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
Sidik Noertjahjono
"Detektor yang baik merupakan divais yang mampu bekerja pada frekuensi yang lebar, peka terhadap foton yang datang dan tidak menimbulkan derau yang mengganggu dalam proses komunikasi maupun dalam bidang instrumentasi.
Untuk maksud tersebut dipilih jenis fotodioda jenis p-i-n dengan bahan aktif semikonduktor GaInAsP sebagai campuran empat macam bahan semikonduktor dari komposisi III dan V pada tabel periodik kimiawi.
Dalam tesis ini dibahas tentang perhitungan dan analisa karakteristik fotodioda p-i-n, dari analisa diketahui bahwa hal ini sangat dipengaruhi aleh ketebalan lapisan yang atas (p+), sedangkan lapisan i (intrinsik) pada ketebalan tertentu sampai maksimum tidak mengalami peningkatan effisiensi, disamping itu unjuk kerja fotodioda secara umum sangat dipengaruhi pula oleh nilai resistansi bebannya.
A good device for detector should operate at. wide band range, and sensitive to incident photon and produce low noise in both fields of communication and instrumentation systems. For that purpose the device used a type of p-i-n photodiode which contains active layers as quaternary of 111 and V compound in periodic system.
This thesis describes design and analysis of p-i-n photodiode to be used as a laser detector for )..= 1,.28 wiz . The Result show that the thickness of first (p+) and second (z) layer will limit the external efficiency of the detector, and also the load resistance will effect influence the performance of the detector.
"
Depok: Fakultas Teknik Universitas Indonesia, 1997
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
"A material study for cathode tube of side window Geiger-Muller detector was carried out. Aim of the study is determine the counting correction factor to the absorpsion gamma radiation, so the type and thickness of materials tube can be sutled...."
Artikel Jurnal  Universitas Indonesia Library
cover
"A new microwave - based transesterification reactor for converting vegetable oils to biodiesel has been developed and tested. The reactor consists of a microwave generator, microwave, waveguide and reaction tube that are compacted in small space. The transesterification of biodiesel feedstocks is performed in the reaction tube that is spatially an extention of the microwave waveguide. Using this scheme, the microwave energy is accumulated in narrow space such that it can be efficiently absorbed by the biodiesel feedstocks. The prototype have been tested by performing the transesterification of biodisel feedstocks, consisting of 80 % cooking oil, 20% of methanol and 1% of potassium hydroxide (KOH). We found that the physical properties of biodiesel product satisfies the SNI standard. The preliminary estimation of the electrical energy consumption yields a value of 0.04 kw/liter of biodiesel feedstock, or correspondingly 40% lower than that consumed by conventional method. Due to compactness of the reactor and low electrical consumption, we believe that this scheme can be further developed and applied for supporting the biodiesel industry in Indonesia. We therefore suggest the development of the microwave - based biodiesel pilot plant at a small to medium entrepreneur or home industry level."
KEENTER
Artikel Jurnal  Universitas Indonesia Library
cover
Mariana Br Subakti; Panjaitan, Poltak
"Landfills Namo Bintang located on the street Pancurbatu - Delitua, sub Pancur Batu, Deli Serdang regency, is a reservoir of waste that came from Medan city and District Pancurbatu. With the operation of the wholesale market Tuntungan (moving from the morning market in Medan Sutomo road) which is located about 3 km from the landfill, then the volume jpf waste in the landfill Namo Bintang will be increased and more smell; reopening of the landfill to collect the garbage from the wholesale market on the market Pancurbatu. Landfills Namo Bintang yet have sewage treatment facilities into materials that are more useful for example compost, landfills is impressed less attention and garbage only in landfills without ig processed at all. The number of garbage collectors who came to take it waste, scrap metal, etc., make it look alive landfill, but the location is seedy and smelly. Around the landfill, there are houses, mostly of ethnic and Java. The content of heavy metals in water wells around the 11, creates a need for us to conduct research chemical analysis of the We from landfills Namo Bintang, whether leachate from the landfill Bintang has been contaminated by heavy metals such as (0,00034mg/L), iron(0,00078mg/L), zinc(0,00S7MG/l), (0,00058mg/L), lead(0,00087mg/L) and arsenic(0,00032mg/L) e garbage is piled on the location of the landfill. The results of laboratory analyzes showed no heavy metals exceeded the threshold contained in the leachate from the three locations. This proves the absence of that occurred in leachate from three sampling sites
"
Universitas HKBP Nonmensen, 2017
VISI 25:1 (2017)
Artikel Jurnal  Universitas Indonesia Library
cover
Kholid Fakhriy
" ABSTRAK
ABSTRAK Nama : Kholid FakhriyProgram Studi : Teknik Metalurgi dan MaterialJudul : Pengaruh Jenis Pasir Sebagai Lapisan Pertama Cetakan Keramik Investment Casting Pada Aplikasi Turbin Radial Inflow Potensi energi geotermal yang besar di Indonesia dapat dimanfaatkan sebagai pembangkit tenaga listrik dengan sistem Organic Rankine Cycle ORC bertemperatur rendah
ABSTRACT ABSTRACT Name Kholid FakhriyMajor Metallurgy and Materials EngineeringTittle Effect of Sand Type as the Ceramic Shell Moulding First Layer of Investment Casting for Radial Inflow Turbine The potential of geothermal energy in Indonesia can be utilized for power generation with organic rankine cycle system ORC low temperature T "
Depok: Fakultas Teknik Universitas Indonesia, 2013
S66645
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Budiman
"Deteksi awal kebakaran mempunyai peranan yang sangat penting terhadap keselamatan penghuni suatu bangunan. Penggunaan detektor asap merupakan salah satu upaya pencegahan kebakaran dalam suatu bangunan. Selama ini pemanfaatan detektor asap masih kurang efektif sehingga kinerja detektor asap tersebut tidak optimal. Penelitian ini difokuskan pada kajian simulasi menggunakan program FDS dan eksperimental untuk mengetahui waktu respon dari dua tipe detektor asap yaitu tipe ionisasi dan fotoelektrik terhadap jenis pembakaran yang berbeda dan pengaruh konfigurasi bentuk geometri yang berbeda yaitu dengan menggunakan sekat dan tanpa sekat terhadap aktivasi detektor asap.
Dari hasil pangujian didapatkan bahwa waktu aktivasi suatu detektor asap pada saat pangujian relatif lebih lama dibandingkan waktu aktivasi yang didapat dari hasil simulasi FDS pada lokasi dan kondisi yang sama. Selain itu didapatkan bahwa jenis pembakaran mempengaruhi waktu aktivasi dari detektor asap. Pola aktivasi detektor asap juga berubah akibat penambahan sekat pada suatu ruangan. Selain itu, ditemukan fenomena bahwa detektor asap yang ditempatkan didekat sekat akan mengalami perlambatan waktu respon.

Early detection of fire has a very important role on the occupier safety in a building. The use of smoke detectors is one of the ways to prevent fire accident in a building. Nowadays, the use of smoke detectors in a building is still not optimal and ineffective. This study is focused on computer simulation using FDS and experiment to determine the response time of two types of smoke detectors, ionization and photoelectric against the variations of burning type and the effect of different room geometry, using smoke curtain and without smoke curtain on smoke detector response.
Experiment result shows that the required response time of smoke detector in experiment is longer than the results from FDS simulation with the same location and condition. From the experiment result was also found that burning type can affect the response time of smoke detector. Smoke detector response is also changed with the addition of smoke curtain in the room configuration. Beside that, smoke detectors which are placed close to the smoke curtain will have slower response time.
"
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50960
UI - Skripsi Open  Universitas Indonesia Library
cover
Aldino Ahmad Ossama
"Penggunaan hasil pemeriksaan poligraf yang dijadikan alat bukti dalam praktik peradilan pidana Indonesia seharusnya dapat diiringi dengan keberadaan regulasi yang memadai serta mekanisme pengawasan yang jelas terhadap pelaksanaan pemeriksaan poligraf agar dapat sejalan dengan asas due process of law. Hal tersebut tentunya berkaitan pada keabsahan suatu alat bukti yang dihadirkan dalam persidangan di pengadilan, mengingat keabsahan suatu alat bukti dapat ditentukan dengan melihat ke belakang terkait kesesuaian tata cara perolehan alat bukti tersebut dengan ketentuan hukum yang berlaku. Penelitian ini dilakukan dengan menggunakan metode penelitian kualitatif dengan bentuk penelitian yuridis normatif. Skripsi ini akan membahas mengenai pemeriksaan poligraf dalam praktik peradilan pidana Indonesia mulai dari regulasi yang berlaku saat ini dan perbandingannya dengan yang berlaku dalam negara Common Law System yaitu Negara Bagian New Mexico di Amerika Serikat, serta peran dan keabsahan alat bukti yang bersumber dari hasil pemeriksaan poligraf dalam praktik peradilan pidana di Indonesia, yang kemudian akan dianalisis keterkaitannya dengan asas due process of law. Kesimpulan dari penelitian ini adalah pemeriksaan poligraf dan penggunaannya di Indonesia saat ini belum diatur secara lengkap, serta tidak terdapat mekanisme pemeriksaan keabsahan dari perolehan alat bukti yang bersumber dari hasil pemeriksaan poligraf, dan penggunaan instrumen pemeriksaan poligraf telah bertentangan dengan asas due process of law. Oleh karena itu, perlu adanya pembahasan lebih lanjut untuk mengkaji penggunaan instrumen pemeriksaan poligraf sebagai alat bukti.

The usage of polygraph examination results that are used as evidence in Indonesian criminal justice practices should be accompanied by the existence of adequate regulations and obvious supervisory mechanisms for the enforcement of polygraph examination, so it could be in line with the due process of law principle. This is certainly related to the validity of the evidence presented in a trial at the court, considering the validity of evidence can be determined by observing the conformity of the procedure for obtaining the evidence with the provisions of applicable law. This research is conducted using qualitative research methods with normative juridical forms of research. This thesis will discuss the polygraph examination in Indonesian criminal justice practices starting from the current applicable regulation and its comparison with those applicable in the Common Law System, namely in the State of New Mexico in the United States of America, as well as the role and validity of the evidence that derived from the result of a polygraph examination in Indonesian criminal justice practices, which will be analyzed about the correlation with the due process of law principle. The conclusion of this thesis are the polygraph examination and its current application in Indonesia are not fully regulated, furthermore there is no supervisory mechanism for checking the validity of the acquisition of evidence derived from the results of the polygraph examination, thus it is not proven to fulfill the due process of law principle. Therefore, there needs to be a further discussion to examine the use of the polygraph examination instruments as evidence."
Depok: Fakultas Hukum Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Syfa Rasyunatussahidah
"Dosimeter merupakan salah satu aspek penting dalam radioterapi untuk verifikasi dosis pengobatan kanker. Saat ini telah dikembangkan detektor microDiamond PTW 60019 yang digunakan untuk mengukur dosis pada lapangan kecil. Tujuan penelitian ini adalah untuk melakukan karakterisasi pada detektor microDiamond PTW 60019 berdasarkan respons energy dependence dan directional dependence menggunakan energi 6 MV FFF dan 10 MV FFF pada berkas foton dengan teknik source to axis distance (SAD) dan source to skin (surface) distance (SSD). Penelitian ini dilakukan dengan mengukur uji kualitas yaitu meliputi uji reproduksibilitas, uji linearitas bacaan, dan uji kebocoran detektor. Kemudian, pengukuran karakteristik energy dependence dan directional dependence menggunakan teknik SAD dan SSD. Energi yang digunakan yaitu 6 MV dan 10 MV, kemudian sudut yang digunakan 0o – 330o dengan rentang 30o. Berdasarkan hasil yang diperoleh pada pengukuran kualitasnya, detektor ini memiliki nilai koefisien variansi 0,0257% pada uji reproduksibilitas dan memperoleh hasil R2 = 0,9947 pada uji linearitas bacaan. Pada pengukuran karakteristik tiap teknik, hasil berdasarkan energinya didapatkan bahwa semakin besar energi yang diberikan maka semakin besar nilai bacaan yang diperoleh. Hasil respons penyimpangan terbesar pada energy dependence dan directional dependence terjadi pada pengukuran sudut 180o. Detektor ini memiliki respons energy dependence dengan penyimpangan sebesar 2,5% pada teknik SAD dan pada teknik SSD sebesar 0,8%. Respons directional dependence yang mempunyai nilai 1±0,5% pada teknik SAD terdapat 7 nilai sudut yaitu (60o, 90o, 300o) pada energi 6 MV FFF dan (60o, 90o, 150o, 300o) pada energi 10 MV FFF, kemudian pada teknik SSD terdapat 4 nilai sudut yaitu (60o, 330o) pada energi 6 MV FFF dan 10 MV FFF. Dari hasil penelitian ini, dapat disimpulkan bahwa energy dependence mempunyai nilai yang lebih baik pada teknik SSD dan directional dependence mempunyai nilai yang lebih baik pada teknik SAD.

Dosimetry is one of the important aspects of radiotherapy for cancer treatment dose verification. A microdiamond detector, PTW 60019, is currently being used to measure dose in a small field. This study investigated characterization of the microDimamond PTW 60019 for energy and directional dependence using unflattened photon energy at 6 MV and 10 MV with the source to axis distance (SAD) and source to skin (surface) distance (SSD) technique. There was an investigated quality check for reproducibility, linearity, and detector leakage. Then, it was measured for energy and directional dependence using SAD and SSD techniques. The energy used is 6 MV and 10 MV and the angle used is 0o –330o with an interval of 30o. As a result of the quality check, the microDiamond has a coefficient of variance of 0,0257% for reproducibility and R2 = 0,9947 for linearity. At the measured characterization, the response electrometer increases as the energy is increased. The result of the response of the largest deviation in energy dependence and directional dependence occurs at a 180o angle measurement. This detector has an energy dependence response with a largest deviation of 2,5% on SAD technique and a deviation of 0,8% on the SSD technique. The directional dependence response has a 1±0,5% for the SAD technique; there was 7 angles (60o, 90o, 300o) for 6 MV FFF and (60o, 90o, 150o, 300o) for 10 MV FFF, for the SSD technique there was 4 angles (60o, 330o) for 6 MV FFF and 10 MV FFF. In conclusion, the SSD technique responds better to energy dependence than the SAD technique responds to directional dependence."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1995
S36370
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>