Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 112592 dokumen yang sesuai dengan query
cover
"This paper present the results of modeling study of two dimensions turbulent flow in an expansion canal by using depth averaged K-E model....."
PRITSAT
Artikel Jurnal  Universitas Indonesia Library
cover
Bahrul Jalaali
"Kajian CFD mengenai aliran air-minyak pada pipa horizontal telah dilakukan dengan menggunakan model multifase Volume-of-Fluid (VOF) yang dikombinasikan dengan skema model turbulen SST . Kajian ini bertujuan untuk melakukan simulasi karakteristik campuran aliran dengan mempertimbangkan parameter temperature. Kasus ini diselesaikan secara numerik menggunakan model volume hingga yang digunakan pada piranti lunak Fluent. Dari hasil simulasi yang dibandingkan dengan hasil eksperimen menunjukkan prediksi yang baik terutama pada pola aliran tertentu. Pada kajian ini, parameter termal diselesaikan menggunakan persamaan energi yang dikopel dengan model multifase. Temperatur aliran air divariasikan pada rentang 300-340K. Dari hasil didapatkan bahwa temperatur berpengaruh mengurangi kekentalan dan densitas fluida. Selanjutnya, pola aliran berubah dimana minyak akan berada diatas air karena memiliki kekentalan dan densitas yang lebih rendah. Kajian ini bermanfaat untuk mengetahui pengaruh temperature pada aliran air-minyak sebagaimana ditemukan dalam aplikasi pengangkatan minyak pada industri perminyakan"
Yogyakarta: Pusat Penelitian dan Pengabdian Pada Masyarakat (P3M) STTA, 2021
620 JIA XIII:2 (2021)
Artikel Jurnal  Universitas Indonesia Library
cover
Edo Widi Virgian
"Kebutuhan terhadap refrigeran alternatif untuk sistem refrigerasi semakin meningkat. Salah satu refrigerant alternatif yang umum digunakan terutama dalam keperluan sistem tata udara pemukiman adalah propana. Propana atau R290 memiliki keunggulan karena selain mudah didapatkan, juga memiliki sifat properti termodinamika dan perpindahan kalor yang cukup baik antara lain viskositas dinamik serta rapat massa jenis yang kecil dan stabil sehingga memiliki kemampuan penyerapan kalor yang baik meskipun membutuhkan perhatian terutama di dalam penannganan potensi bahaya ledakan. Salah satu metode yang umum digunakan di dalam analisis performa sistem refrigerasi adalah aliran dua fasa. Perhitungan korelasi perhitungan tekanan dilakukan dengan menggunakan basis data yang berasal dari penelitian Pamitran, et. al (2011) yang terdiri dari fluks kalor q = 5-20 kW/m2, G = 50-180 kg/m2. s; temperatur saturasi 0-11 oC, dan fraksi massa atau kualitas uap 0-1. Hasil menunjukkan bahwa fluks laju aliran massa, fluks kalor, dan bilangan Reynolds fasa campuran berbanding lurus terhadap penurunan tekanan aktual, persamaan korelasi Friedel (1979) memberikan nilai yang lebih akurat untuk memprediksi penurunan tekanan dengan nilai MAE (Mean Absolute Error) sebesar 59,12 % dan regim aliran yang terbentuk adalah regim aliran plug (kantong udara), slug, dan transition menuju wavy-annular menurut peta pola aliran Zhuang, et.al (2016).

The need for alternative refrigerants for refrigeration system is increasing. One of the alternative refrigerants that commonly used, especially in residential air conditioning systems, is propane. Propane or R290 has the advantage because in addition to being easy to obtain, it also has good thermodynamic properties and heat transfer, including small and stable dynamic viscosity and density so that it has good heat absorption ability although it requires attention, especially in potential explosion hazards. One of the methods that commonly used in refrigeration system performance analysis is two-phase flow. Calculation of the correlation of pressure drop is carried out using a database derived from Pamitran, et. al (2011) which consists of parameters range such as heat flux q = 5-20 kW/m2, G = 50-180 kg/m2. S, saturation temperature 0-11 oC, and mass fraction or vapor quality 0-1. The results show that the mass flow rate flux and heat flux are directly proportional to the actual pressure drop with a greater effect of mass flow rate flux and Friedel's (1979) correlation equation provides a more accurate value for predicting pressure drop with MAE (Mean Absolute Error) value of 59,12 %. On the flow pattern map of Zhuang, et.al (2016) a plug-slug and transition flow condition to wavy-annular is formed."
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Muhammad Hanan Thomas
"Dalam penilitian ini akan dibahas tentang penurunan tekanan yang terjadi pada aliran evaporasi dua fasa pada kanal mini horizontal dengan menggunakan refrigeran alternatif R-290. Pada penilitian ini akan dicari nilai prediksi penurunan tekanan secara teoritis yang didapatkan melalui pendekatan Lockhart-Martinelli dan Chisolm dengan bantuan program Matlab. Program Fluent juga digunakan untuk mendapatkan prediksi penurunan tekanan aliran evaporasi dua fasa berdasarkan simulasi CFD. Hasil dari prediksi tersebut kemudian akan dibandingkan dengan nilai penurunan tekanan dari hasil pengukuran menggunakan alat uji refrigerasi dengan sistem pemutaran tertutup untuk mendapatkan nilai deviasi untuk masing-masing pendekatan teoritis dan dari hasil simulasi CFD.

This study will examine the pressure drop for two phase flow boiling in horizontal mini channel using refrigerant R-290. This study will look into obtaining theoretical pressure drop prediction using Lockhart-Martinelli and Chisolm correlations with the help of Matlab software. The Fluent software will also be used to obtain the two phase flow boiling pressure drop prediction using CFD simulation. These prediction results will then be compared to the pressure drop from experiment data using closed loop refrigeration system experiment apparatus to obtain the deviation values for each theoretical correlations and from the CFD simulation."
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50936
UI - Skripsi Open  Universitas Indonesia Library
cover
Damawidjaya Biksono
"Penelitian aliran campuran udara-air di dalam pipa spiral horizontal telah dilakukan. Efek aliran di dalam pipa spiral melihat letak lokasi perubahan gelembung udara. Tujuan dari studi ini memperjelas karakteristik aliran campuran udara-air yang mengalir di dalam pipa spiral horizontal. Pengukuran kerugian tekanan dan letak lokasi penyebaran gelembung udara-air pada penampang melintang pipa masing-masing digunakan manometer dan digital video. Hasil koefisien gesek campuran udara-air lebih besar dibandingkan koefisien gesek pada air dan letak posisi udara dapat dijelaskan."
Depok: Fakultas Teknik Universitas Indonesia, 2005
T16149
UI - Tesis Membership  Universitas Indonesia Library
cover
Lazuardy Akbar
"Sebuah experiment telah dilakukan untuk penggunaan refrigeran ramah lingkungan menjadi kebutuhan manusia. Dalam percobaan aliran mendidih R-22, diameter pipa konvensional 7,6 mm digunakan. Variasi fluks panas dari 5,9 kW / m2 hingga 25,04 kW / m2, fluks massa 282 kg / m2.s hingga 630 kg / m2.s, dan suhu saturasi dari -0,42 ° C hingga 11,97 ° C untuk hasil R- 22. Hasil tersebut dipengaruhi oleh penurunan tekanan di fluks massa, fluks panas dan temperature saturasi. Adapun perpindahan kalor dipengaruhi oleh fluks kalor dan temperatur, sedangkan fluks massa menunjukkan tidak ada perubahan dalam perpindahan kalor untuk nilai R-22. Dalam rangka untuk mencari dan membandingkan hasil, Computational Fluid Dynamics (CFD) telah menjadi pendekatan untuk desaindan evaluasi kinerja. Pada penelitian ini, simulasi numerik untuk internal pipa dilakukan dengan menggunakan model Eulerian dengan paket CFD, ANSYS Fluent 12.1. Turbulensi di fase cair dan gas dijelaskan menggunakan model k-ε. Parameter hidrodinamika global seperti fluks masa dan kecepatan cairan telah diteliti untuk berbagai dangkal uap dan kecepatan gas, dengan simulasi 3D. Selain itu, studi geometri dan skala pengaruh pada pipa horisontal telah dipertimbangkan. Hasil penelitian menunjukkan fluks massa dan fluks panas memiliki efek signifikan pada parameter hidrodinamik, yang dapat menyebabkan efek besar pada hasil penurunan tekanan. Perhitungan numerik dengan sistem aliran dua fase gas-cair telah dilakukan untuk mengetahui pengaruh penurunan tekanan, perbedaan suhu, dan massa penurunan fluks pada karakteristik hidrodinamika fluks massa yang berbeda dan fase atau jenis arus. Hasil ini diproduksi mengungkapkan bahwa CFD memiliki potensi yang sangat baik untuk mensimulasikan dua-fase sistem aliran.

An experiment has been done previously to the use of environmentally friendly refrigerants into human needs. In the experiment of boiling flow conditions, R-22 is done in a conventional pipe diameter of 7.6 mm. Variation of heat flux of 5.9 kW / m2 to 25.04 kW / m2, the mass flux of 282 kg / m2.s up to 630 kg / m2.s, and the saturation temperature of -0.42 ° C to 11.97 ° C for R-22.The results are influenced by the pressure drop in the mass flux, heat flux and temperature saturation. As for the heat, transfer is affected by the heat flux and temperature saturation, whereas the mass flux showed no change in the heat transfer value for R-22. In order to find and compare results, Computational Fluid Dynamics (CFD) has become an approach for design, scale-up and performance evaluation. In the present work, numerical simulations for internal-pipe were performed using the Eulerian model with CFD package, ANSYS Fluent 12.1. The turbulence in the liquid and vapor phase are described using the k-ε model. Global hydrodynamic parameters like mass flux and liquid velocity have been investigated for a range of superficial vapor and gas velocities, only with 3D simulations. Moreover, the study of geometry and scale influence on the horizontal pipe have been considered. The results suggest mass flux and heat flux have significant effects on the hydrodynamic parameters, which may lead to substantial effects on the pressure drop results. Numerical calculations with gas-liquid two-phase flow system have been carried out to investigate the effect of mass flux and heat flux on the hydrodynamic characteristics of two-phase flows. These produced results reveal that CFD have excellent potential to simulate two-phase flow system.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S63202
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rio Hidayah
"Proses pencampuran pupuk dan air sangat penting dalam pertanian jagung dan padi. Untuk memenuhi kebutuhan campuran pupuk dan air dalam skala besar dan konstan, diperlukan sistem pencampuran dengan memanfaatkan aliran turbulen. Alat yang dapat digunakan yaitu gabungan antara nozel jet dan pipa venturi. Interaksi antara kedua alat ini dalam mencampurkan pupuk dan air perlu dianalisa. Analisa dilakukan dengan simulasi computational fluid dynamics (CFD). Tujuan dari studi ini adalah untuk menganalisa akibat dari posisi nozel jet di dalam pipa venturi terhadap proses pencampuran pupuk dan air. Simulasi numerik dilakukan dengan model multifasa dan sifat termofisik konstan. Bentuk sistem yaitu pipa venturi klasik berdasarkan standar ISO 5167-4 2003 dengan nozel jet dipasangkan pada salah satu diantara dua posisi. Simulasi dilakukan dalam kondisi turbulen model Eulerian k-epsilon. Variasi simulasi dilakukan dengan beberapa kecepatan aliran masuk air dan pupuk dengan fraksi volume kedua fluida konstan. Hasil yang didapatkan adalah bahwa kedua geometri memiliki pola dispersi pupuk yang berbeda. Variasi fraksi volume pupuk pada kedua geometri berada pada rentang 0,18% hingga 1,79%. Kata Kunci: Pertanian, Pencampuran, CFD, Fraksi Volume, Pupu

Water and fertilizer mixing is very important in paddy and corn agriculture. To fulfill a large and constant amount of fertilizer-water mixture, it requires a mixing system that utilizes turbulent flow. The tools that will be used are a combination of jet nozzle and venturi pipe. The interaction of these tools in fertilizer-water mixing need to be analyzed. The analysis will be done with CFD simulations. The goal of these study us to analyze the effect of jet nozzle position in venturi pipes against fertilizer-water mixing process. Numerical simulation is proceeded with multiphase model and constant thermophysical properties. The system shape is a classic venturi pipe based on ISO 5167-4 2003 standards with nozzle jet placed in one of two positions. The simulation is running on Eulerian kepsion turbulence model. These simulations are varied with several water and fertilizer inlet flow rate with volume fraction of both fluids constant. The results that acquired are that both geometries have different fertilizer dispersion pattern which tends to be inversed. The fertilizer volume fraction on both geometries is appear in 0,18% to 1,79% interval."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Marpaung, Nurdiansyah
"Skripsi ini membahas mengenai Pengurangan Koefisien Gesek Larutan PEG 4000 800 PPM, 1000 PPM, 1200 PPM. Eksperimen ini menggunakan pipa bulat acrylic berdiameter luar 12,7 mm dan diameter dalam pipa 11 mm pada aliran Turbulen. Aliran dalam pipa tersebut diuji dengan menambahkan Larutan PEG 4000 kedalam air murni pada konsentrasi 800 ppm, 1000 ppm dan 1200 ppm dengan aliran Turbulen. Dari hasil data, tabel, dan grafik menunjukkan bahwa dengan penambahan Larutan PEG 4000 pada konsentrasi 800 ppm, 1000 ppm, dan 1200 ppm kedalam air murni terjadi Drag Reduction. Dari hasil data eksperimen penambahan dengan konsentrasi 800 ppm Larutan PEG 4000 yang dicampurkan kepada air murni dapat menurunkan koefisien gesekan sebesar 16,7 % pada f 12 dan 18,5 % pada f 23, sedangkan dengan konsentrasi 1000 ppm Larutan PEG 4000 dapat menurunkan koefisien gesekan sebesar 17,4 % pada f 12 dan 18,9 % pada f 23, dan dengan konsentrasi 1200 ppm Larutan PEG 4000 dapat menurunkan gesekan sebesar 19,2 % pada f 12 dan 19,8 % pada f 23 dengan Bilangan Reynold 21.222.

This thesis discusses about Reduction Coefficient of Friction with solution of PEG 4000 with concentration of 800 PPM, 1000 PPM, 1200 PPM. This experiment uses a round acrylic tube outer diameter 12,7 mm and 11 mm inner diameter of the pipe in Turbulent flow. The flow in the pipe tested by adding a solution of PEG 4000 into pure water at a concentration of 800 PPM, 1000 PPM and 1200 PPM with a Turbulent flow. From the data, tables, and graphs show that with the addition of PEG 4000 solution at a concentration of 800 PPM, 1000 PPM, and 1200 PPM into pure water occurs Drag Reduction. From the experimental data with the addition of concentrations 800 PPM solution of PEG 4000 are mixed to pure water can decrease the friction coefficient of 16,7 % at f 12 and 18,5 % at f 23, while a concentration of 1000 PPM solution of PEG 4000 can reduce the coefficient of friction 17,4 % at f 12 and 18,9 % at f 23, and a concentration of 1200 PPM solution of PEG 4000 can reduce friction by 19,2 % at f 12 and 19,8 % at f 23 with Reynold's Numbers 21.222."
Depok: Fakultas Teknik Universitas Indonesia, 2011
S133
UI - Skripsi Open  Universitas Indonesia Library
cover
Samuel Agustinus Adam
"[Pada paper ini void fraction dari R-290 di investigasi. Penggunaan R-290 ditujukan untuk menggantikan R-22, dikarenakan R-22 memiliki nilai ODP (Ozone Depletion Potential) sebesar 0.05 dan nilai GWP (Global Warming Potential) sebesar 1700. Nilai void fraction dibutuhkan karena berhubungan dengan prediksi nilai dari jatuh tekanan, yaitu pada jatuh tekanan akibat akselerasi. Sehingga, merupakan suatu kebutuhan untuk melakukan studi komprehensif mengenai void fraction pada aliran didih dua fase pada pipa konvensional berdiameter dalam 7.6 mm. Data primer didapatkan dengan melakukan eksperimen pada kondisi: Fluida kerja R-290, pipa horizontal berdiameter dalam 7.6 mm, temperatur saturasi pada rentang 5 hingga 15ºC, fluks kalor pada rentang 9 hingga 20 kW/m2 dan fluks massa pada rentang 300 hingga 420 kg/m2.s. Hasil jatuh tekanan eksperimen yang di dapatkan kemudian dibandingkan dengan jatuh tekanan prediksi., In this present paper the void fraction of R-290 was investigated. The use of R-290 is to replace R-22, since R-22 has 0.05 Ozone Depletion Potential (ODP) and 1700 Global Warming Potential (GWP). The relevancy to obtain the void fraction was related to predict the value of pressure drop, especially accelerational pressure drop. Therefore, it is a necessity to conduct a comprehensive study about void fraction in two-phase flow boiling in conventional pipe with 7.6 mm inner diameter. To obtain the primary data, the experiment was conducted with the experimental conditions of R-290 working fluid, 7.6 mm inner diameter horizontal tube, 5 to 15ºC saturation temperature, 9 to 20 kW/m2 heat flux, and 300 to 420 kg/m2.s mass flux. The recent results of pressure drop were compared to some existing method of pressure drop calculations]"
2015
T44149
UI - Tesis Membership  Universitas Indonesia Library
cover
"Since B A Tom 's found out the drag reduction phenomena, which occurs in polymer solutions in
1948 many studies, have been done for it because we can apply to the economizing energy system the
phenomena. The drag reduction is the application of the turbulent modification of the flow and we can
apply it for the turbulent flow region. We measured the turbulent pressure loss in the square ducts and
circular pipe flow of a guar gum solution by manometer, and found that the friction factor in the ducts
flow ware expressed by Re. Pressure loss in ducts ware measured for various concentrations of guar
gum and various diameters of pipes in water to study the effect of the additive on drag reduction, It is
found that guar gum acts like other drag reduction polymer additives because it constant the friction
factor in laminar regime, modify the transition to turbulent flow, and reduces the friction factor the fully
turbulent regime.
"
Jurnal Teknologi, 21(1) Maret 2007 : 32-38, 2007
JUTE-21-1-Mar2007-32
Artikel Jurnal  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>