Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 153855 dokumen yang sesuai dengan query
cover
Yuli Amalia Husnil
"Tesis ini membahas pengaruh perlakuan paparan gelombang mikro dengan variasi daya dan waktu paparan gelombang mikro terhadap kandungan bambu yang larut dalam air, jumlah gula pereduksi, dan konsentrasi etanol. Hasil penelitian menunjukkan bahwa perlakuan gelombang mikro mampu meningkatkan persentase kandungan larut air. Hal ini semakin diperkuat dengan hasil gula pereduksi dan etanol yang lebih tinggi pada substrat yang telah mengalami perlakuan gelombang mikro dibanding substrat yang tidak mengalami perlakuan.

This thesis explains the effect of microwave exposure with power and time variation on water soluble content of bamboo, reducing sugars and also yields of ethanol. Experimental data shows that microwave exposure could increase the water soluble content of bamboo. This result is emphasized with result of reducing sugars and ethanol yield that higher in substrate that had been exposed on microwave radiation."
2009
T25899
UI - Tesis Open  Universitas Indonesia Library
cover
Suharno
"Bahan yang memiliki sifat ferroelektrik dan ferromagnetik berpotensi sebagai absorber gelombang mikro dan memiliki peranan penting pada dunia militer. BiFeO3 merupakan salah satu bahan multiferroik yang memiliki sifat ferroelektrik dan ferromagnetik. Pada penelitian ini dilakukan rekayasa sintesa BiFeO3 dengan doping Yttrium dan Seng dengan variasi konsentrasi (%wt) 6, 12, dan 18%. Sintesa BiFeO3 telah berhasil disintesis dengan metode sol-gel autocombustion. Melalui uji XRD, fasa BiFeO3 diperoleh pada temperatur 750°C selama 5 jam. Hasil refinement menunjukkan bahwa BiFeO3 memiliki struktur kristal rhombohedral space grup R3c. BiFeO3 doping Yttrium dan Seng di atas 12% (%wt) terjadi perubahan struktur kristal dari rhombohedral ke orthorombic. Kurva hysterisis menunjukkan bahwa BiFeO3 memiliki saturasi magnetik 3.04 emu/g, remanen magnetik 0.26 emu/g, dan medan koersivitas 0.0013 T. BiFeO3 doping Yttrium dengan konsentrasi (%wt) 12% terjadi peningkatan nilai saturasi magnetik, remanen magnetik, dan medan koersivitas namun BiFeO3 doping Seng dengan konsentrasi (%wt) 12% terjadi penurunan nilai saturasi magnetik, remanen magnetik, dan medan koersivitas. BiFeO3 doping Yttrium 12% (%wt) dan Seng 12% (%wt) memiliki nilai saturasi magnetik 8.18 emu/g, remanen magnetik 2.92 emu/g, medan koersivitas 0.0036 T. Pada frekuensi 1 kHz BiFeO3 memiliki konstanta dielektrik sebesar 239.12 dan adanya doping Yttrium dan Seng terjadi penurunan nilai konstanta dielektrik. Hasil pengujian sifat penyerapan gelombang mikro pada frekuensi X band (8.2 ? 12.4 GHz) diperoleh bahwa bahan Bi0.88Y0.12FeO3/C memiliki refleksi loss -39.42 dB pada frekuensi resonansi 11.47 GHz. Dengan demikian bahan Bi0.88Y0.12FeO3/C dapat dijadikan bahan penyerap gelombang mikro pada frekuensi X band.

Materials with both ferroelectric and ferromagnetic properties are potential candidate for microwave absorbers and play important role in military world. One of them is BiFeO3, a multiferroic material with both ferroelectric and ferromagnetic properties. In this research, BiFeO3 has been synthesized successfully via auto-combustion sol-gel method. To improve its properties, yttrium- and zinc-doped BiFeO3 has been synthesized with various doping concentrations, i.e. 6, 12, and 18 wt.%. X-ray diffraction patterns showed that BiFeO3 phase was obtained after heating at 750ᵒC for 5 hours with rhombohedral crystal structure and space group of R3c. The hysteresis curve of BiFeO3 showed a magnetic saturation of 3.04 emu/g, magnetic remnant 0.26 emu/g and coercive field 0.0013 T. Yttrium- and zinc-doped BiFeO3 over 12wt.% showed a structural change from rhombohedral to orthorhombic with magnetic saturation of 8.18 emu/g, the magnetic remnant of 2.92 emu/g and coercive field of 0.0036 T. Yttrium-doped BiFeO3 showed an increase in the magnetic saturation, the magnetic remnant and the coercive field; however zinc-doped BiFeO3 showed a decrease in the magnetic saturation, the magnetic remnant and coercive field. At a frequency of 1 kHz, the dielectric constant of BiFeO3 was 239.12, and this value will decrease when it was doped by yttrium and zinc. Further investigation on the application of this material, composites Bi0.88Y0.12FeO3/C has also been synthesized. The composites showed a reflection loss of -39.32 dB within the frequency range of 8.2-12.4 GHz (X-band) particularly at the frequency of 11.47 GHz with the absorptivity of 98.60%. Based on this results, composite Bi0.88Y0.12FeO3/C material could be used as a potential microwave absorber in the X-band frequency.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
D2061
UI - Disertasi Membership  Universitas Indonesia Library
cover
Syahrul Ramdani
"ABSTRAK
Proses pemindaian dini saat ini masih dilakukan dengan Computed Tomography Scan atau Magnetic Resonance Imaging. Namun, alat pemindai tersebut memiliki biaya yang mahal dan ukuran yang besar. Pencitraan gelombang mikro merupakan salah satu teknik tomografi alternatif yang dapat menutupi kekurangan tersebut. Sementara itu, sistem pencitraan medis membutuhkan jumlah pengukuran yang cukup banyak untuk mendapatkan citra hasil rekonstruksi yang baik. Untuk mengurangi jumlah pengukuran, penelitian ini mengusulkan pendekatan Compressive Sensing CS untuk aplikasi pencitraan gelombang mikro. Proses pemindaian dilakukan pada perangkat lunak Computer Simulation Technology dengan objek uji berupa phantom kubus dua lapis dengan permitivitas yang berbeda. Agar sesuai dengan kerangka CS , matriks pembobotan Discrete Radon Transform dipilih sebagai matriks proyeksi. Discrete Cosine Transform dan Basis Pursuit dipilih sebagai matriks sparse dictionary dan algoritma rekonstruksi sinyal sparse. Pada proses pemindaian, jumlah translasi dan rotasi divariasikan untuk menguji kinerja CS. Data pengukuran S21 berhasil direkonstruksi menjadi citra dengan pendekatan CS. Hasil rekonstruksi menunjukkan bahwa penambahan jumlah translasi dan rotasi dapat meningkatkan kualitas citra hasil rekonstruksi, meskipun tidak terdapat hubungan yang linear antara keduanya. Secara kualitatif dan kuantitatif, citra hasil rekonstruksi menggunakan CS memiliki kualitas yang lebih baik dibandingkan dengan yang direkonstruksi menggunakan algoritma Filtered Back Projection dan Simultaneous Algebraic Reconstruction Technique. Sebagai tambahan, CS terbukti dapat merekonstruksi data pengukuran sebenarnya dari phantom fisik menjadi sebuah citra.

ABSTRACT
Early detection is still generally performed by using Computed Tomography scan or Magnetic Resonance Imaging. However, those modalities have high production costs and considerable size. Microwave Imaging is one of the alternative tomography techniques that can overcomes those aforementioned problems. Meanwhile, the medical imaging systems require a great amount of data measurements to obtain a good reconstructed image. In order to reduce the number of measurements, this research proposes a Compressive Sensing CS approach for microwave imaging application. The scanning process is conducted on Computer Simulation Technology software. A two layer cube phantom with different permittivity is used as the scanned object. To meet the framework of CS, weight matrix of Discrete Radon Transform is utilized as projection matrix. Discrete Cosine Transform and Basis Pursuit are selected as sparse dictionary matrix and sparse reconstruction algorithm respectively. In the data acquisition process, the number of translations and rotations is varied to test the performance of CS. The measured S21 data are successfully reconstructed by CS approach into an image. The reconstruction results show that adding the number of translations and rotations can improve the quality of the reconstructed image, although there is no linear relationship between them. Qualitatively and quantitatively, the image reconstructed using CS has a better quality compared to that reconstructed using Filtered Back Projection and Simultaneous Algebraic Reconstruction Technique algorithm. In addition, CS is proved to be able to reconstruct the real measurement data from the physical phantom into an image"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Telah dikembangkan alat yang dapat digunakan untuk membantu menetukan sudut pada pembuatan lead brick (plain brick). Sudut yang dimaksud adalah sudut luar dan dalam pada lead brick (plain brick) male and female yang harus memenuhi standart ISO 7212-1986 dengan toleransi sudut male 90o o+15 dan female 90o o-15. Ketepatan pengerjaan sudut ini menjadi sangat penting untuk menjaga keseimbangan supaya susunan lead brick tidak miring atau rubuh. Oleh karena itu setiap pengerjaannya menggunakan rotary table karena memudahkan dalam setting benda kerja dan kepresisian pengukuran bisa dijaga. Namun dikarenakan banyaknya operator yang belum bisa menggunakan alat ini sebagai alat bantu untuk mencapai toleransi sudut yang disyaratkan, maka diperlukan adanya metode pengukuran yang tepat pada proses machining lead brick menggunakan alat bantu rotary table sehingga dapat digunakan sebagai acuan untuk mencapai tingkat ketelitian sudut 0,03o pada pembuatan sudut luar dan dalam (male and female) lead brick (plain brick)."
Artikel Jurnal  Universitas Indonesia Library
cover
Icha Fatwasauri
"Pencegahan kanker dapat dilakukan dengan deteksi dini menggunakan pemindai seperti Computed Tomography (CT) Scan dan Magnetic Resonance Imaging (MRI). Namun, modalitas tersebut memiliki biaya produksi yang tinggi dan ukuran yang besar. Alternatif yang digunakan untuk mengatasi masalah ini adalah menggunakan pencitraan gelombang mikro. Pencitraan gelombang mikro membutuhkan data pengukuran besar untuk meningkatkan kualitas gambar. Untuk mengatasi kelemahan ini, proses penelitian ini adalah merekonstruksi algoritma pencitraan gelombang mikro dengan jumlah pengukuran yang lebih rendah menggunakan pendekatan Compressive Sensing (CS). CS memungkinkan merekonstruksi sinyal dari sejumlah kecil pengukuran daripada yang diperlukan dalam metode pengambilan sampel konvensional. Penelitian ini berkontribusi dengan menambahkan informasi spasial menggunakan Total Variation (TV) dan menyelesaikan masalah optimasi menggunakan Alternating Direction Method of Multipliers (ADMM). Penelitian ini dianalisis untuk kinerja kualitatif dan kuantitatif. Parameter yang digunakan dalam analisis kuantitatif adalah MSE dan SSIM. Hasil penelitian ini menunjukkan bahwa algoritma yang diusulkan berhasil mengimplementasikan rekonstruksi CS dengan menambahkan TV dalam hal kualitas gambar dan parameter kuantitatif.

Prevention of cancer can be done by early detection using a scanner such as Computed Tomography (CT) Scan and Magnetic Resonance Imaging (MRI). However, those modalities have high production cost and considerable size. The alternative used to overcome this problem is using microwave imaging. Microwave imaging requires large measurement data to improve image quality. To overcome these weaknesses, this research process is algorithmic reconstruct the microwave images with lower number of measurements using Compressive Sensing (CS) approach. CS enables reconstructing a signal from a smaller number of measurements than which is required in the conventional sampling method. This research contributes by adding spatial information using total variation (TV) and solving the problem of optimization using Alternating Direction Method of Multipliers (ADMM). This research were analyzed for the qualitative and quantitative performance. Parameters used in quantitative analysis are MSE and SSIM. The results of this research show that the proposed algorithm successfully implemented the reconstruction of CS by adding TV in terms of image quality and quantitative parameters.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
T55069
UI - Tesis Membership  Universitas Indonesia Library
cover
Ria Aprilliyani
"Sel tubuh manusia mengalami pertumbuhan, pembelahan, dan pergantian setiap menitnya secara normal. Pola hidup yang tidak baik terkadang menyebabkan sel mengalami pertumbuhan, pembelahan yang lebih cepat dibandingkan dengan pergantiannya. Pendeteksian dini sangat dianjurkan untuk mengetahui kondisi tubuh secara berkala. Kebutuhan dalam melihat obyek secara non-invasive tanpa merusak dan non-intrusive tanpa memasukkan alat mendorong berkembangnya teknologi tomografi di bidang kedokteran. Pemanfaatan Microwave Imaging dalam bidang medik sebagai teknologi tomografi mengalami peningkatan, karena kelebihan yang dimiliki dibandingkan dengan teknologi tomografi lainnya yaitu resiko kesehatan kecil, biaya yang murah dalam implementasi dan operasinya, dan mudah untuk digunakan. Perbedaan parameter dielektrik pada jaringan normal dan tidak normal dimanfaatkan dalam pendeteksian. Transmitter akan mengalirkan gelombang mikro melalui obyek yang akan diamati dan diterima oleh receiver. Informasi yang dihasilkan dari receiver akan direkonstruksi menggunakan algoritma untuk mencitrakan obyek bagian dalam. Dalam skripsi ini akan dibuat program algoritma Simultaneous Algebraic Reconstruction Technique SART serta menganalisisnya secara kualitatif dan kuantitatif. Selain itu, akan dibandingkan dengan algoritma Filtered Back Projection FBP dan Algebraic Reconstruction Technique ART untuk melihat hasil citra SART secara keseluruhan. Program SART telah berhasil dibuat dan analisis menunjukkan bahwa hasil rekonstruksi citra SART memiliki hasil citra yang paling baik secara kualitatif dan kuantitatif dibandingkan dengan algoritma ART dan FBP. Sedangkan waktu yang dibutuhkan dalam satu kali iterasi adalah 1 menit 50 detik.

Human cells grow, divide and replace into new cells every minute normally. Sometimes Improper lifestyle causes cell growth and divide faster than cell replacement. Early detection is recommended to know the condition of the body regularly. The challenge for non invasive and non intrusive object encourage the development of tomographic technology in the field of medicine. Utilization of Microwave Imaging in the medical field as a tomography technology has increased, because of its advantages compared to other tomography technologies that are low health risk, low cost in implementation and operation, and easy to use. The differences of dielectric parameters in normal and abnormal tissue are utilized in detection. Transmitter will transmit microwaves through the object to be observed and received by the receiver. The information generated from the receiver will be reconstructed using an algorithm to image the inner object. In this thesis will be created algorithm program Simultaneous Algebraic Reconstruction Technique SART and analyze it qualitatively and quantitatively. In addition, it will be compared with Filtered Back Projection FBP algorithms and Algebraic Reconstruction Technique ART to see overall SART image results. The SART program has been successfully created and analysis shows that the results of SART image reconstruction have the best image results qualitatively and quantitatively compared to the ART and FBP algorithms. While the time required in one time iteration is 1 minute 50 seconds.
"
Depok: Fakultas Teknik Universitas Indonesia, 2017
S69597
UI - Skripsi Membership  Universitas Indonesia Library
cover
Bhargava, Deepshikha
"The rapidly increasing concern of non-ionizing microwave radiations affecting human health adversely has been gaining much of attention. a large volume of research studies have been published in the past decade. most of the previous review literature in this key research area are limited to a certain domain leading to questionable gaps that still need to be filled. this paper, therefore, investigates and analyses all possible gaps, which are left in recent literature related to this issue and aims to provide an inclusive up-to-date overview of evidences and epidemiological studies on different parts of human body, in both adult and children. based on the literature review, it is evident that the rise in the Specific Absorption Rate (SAR) above its maximum value due to the exposure from non-ionizing radiation can cause severe effect on human body such as a cataract formation in the eye, a shortfall in sperm count in men etc. specific Anthropomorphic Mannequin (SAM) model, which is used as a certification technique for cell phone, is found to be overestimating the adult and child head exposure by using same geometric model for child and adult head types. It has also been observed that the electromagnetic radiation has both positive and negative effect on the human life, depending on the context of its application. It is envisaged that human can gain from the positive side and avoid the negative effect. A step by step example of numerical simulation model is illustrated to support future researchers in developing further work in this research area."
Pathum Thani: Thammasat University, 2017
607 STA 22:3 (2017)
Artikel Jurnal  Universitas Indonesia Library
cover
Agus Riyanto
"Radiografer secara umum mempunyai tugas dan tanggung jawab untuk melakukan pemeriksaan pasien secara radiografi meliputi pemeriksaan untuk radiodiagnostik termasuk kedokteran nuklir dan ultrasonografi (USG) dan melakukan tindakan proteksi radiasi dalam mengoperasikan peralatan radiologi. Penelitian ini bertujuan memprakirakan risiko pajanan radiasi sinar-X pada pekerja radiasi di Departemen Radiologi RSUPN Cipto Mangunkusumo. Dalam perhitungan prakiraan risiko pajanan radiasi sinar-X, dosis pajanan radiasi sianr-X radiografer diperoleh dari hasil pengukuran film badge. Data pola aktifitas (lama kerja, frekuensi pajanan dan masa kerja) diperoleh berdasarkan hasil wawancara pada 35 radiografer di Departemen Radiologi RSUPN Cipto Mangunkusumo.
Berdasarkan perhitungan yang dilakukan, nilai rata-rata Excess Cancer Risk (ECR) lifetime (4,8E-2) dan realtime (1,9E-2). Karena secara teoretis karsinogenisitas tidak mempunyai nilai ambang atau non threshold, maka prakiraan risiko dinyatakan unacceptable (dosis tidak dapat diterima) bila ECR < E4. Kisaran angka E-4 diperoleh dari nilai default karsinogenistas yang digunakan oleh US-EPA (1990). Berdasarkan perhitungan ECR lifetime dan ECR realtime diperoleh gambaran prakiraan risiko efek karsinogenik yang terjadi pada radiografer di Departemen Radiologi RSUPN CM, dinyatakan aceptable pada risiko kanker baik pada ECR lifetime maupun realtime.

Radiographer in general have a duty and responsibility to audit includes examined patients for radiodiagnostic including nuclear medicine and ultrasonography (USG), and radiation protection in radiology and operating equipment. This study aims to estimated the risk of X-ray radiation exposure to radiographer in the Department of Radiology RSUPN Cipto Mangunkusumo using Environmental Health Risk Analysis (ARKL). In calculating the estimated risk forecasts ARKL, risk of X-ray radiation exposure dose radiographer obtained from measurements of the film badge. Data patterns of activity (duration of work, frequency of exposure and years of work) obtained based on the results of a survey of 35 radiographers in the Department of Radiology RSUPN Cipto Mangunkusumo.
Based on the calculations performed, the average value of Excess Cancer lifetime Risk (ELCR) is 4,8E-2 and the value of Excess Real-time Cancer Risk (ERRC) the average is 1,9E-2. Because theoretically carcinogenicity has non-threshold value, then the forecast is declared unacceptable when ECR < E-4. Range of numbers obtained from the E-4, carcinogenicity default values used by the US-EPA (1990). Based on the calculation of the ELCR and ERCR forecasts illustrate the risk of carcinogenic effects that occur in the radiographers in the Department of Radiology RSUPN CM, acceptable on cancer risk both in the ELCR and ERRC.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2014
T43374
UI - Tesis Membership  Universitas Indonesia Library
cover
Puji Astuti Tri Kusumawati
"Latar Belakang: Tingginya pertumbuhan kasus keganasan ginekologi dan organ panggul menyebabkan penggunaan terapi radiasi meningkat. Akan tetapi, terapi radiasi juga cukup banyak menimbulkan proktitis radiasi sebesar 30%. Tatalaksana menggunakan agen topikal seperti SCFA, sukralfat, steroid, formalin, dan 5-ASA diketahui memiliki hasil yang baik, namun belum banyak studi yang membandingkan terapi mana yang lebih superior. Tujuan: Menilai efektivitas beberapa terapi topikal terhadap perbaikan gejala klinis dan gambaran endoskopi pasien proktitis radiasi.
Sumber Data: Pencarian utama dilakukan secara elektronik pada basis data PubMed, Cochrane/CENTRAL, Scopus, dan Science Direct antara September hingga November 2020. Pencarian sekunder dilakukan secara snowballing pada referensi studi yang terkait, dan melalui register uji klinis yang tersertifikasi lainnya seperti Global Index Medicus, Garba Rujukan Digital (GARUDA), ClinicalTrial.gov, dan International Clinical Trials Registry Platform (ICTRP) WHO.
Seleksi Studi: Studi uji klinis acak terkontrol dengan intervensi terapi topikal dibandingkan plasebo atau terapi topikal lainnya atau kombinasi terapi medikamentosa, yang menilai luaran berupa respon gejala klinis dan gambaran endoskopi, serta dapat disertai luaran lain, ataupun tidak. Tidak ada batasan terhadap tahun publikasi dan bahasa. Penilaian judul, abstrak, dan studi dilakukan oleh dua orang peninjau independen. Dari total 1786 studi, didapatkan 9 studi memenuhi kriteria eligibilitas.
Ekstraksi Data: Ekstraksi data dilakukan oleh dua peninjau independen dan dikonfirmasi pada peninjau ketiga. Konfirmasi data dilakukan dengan menghubungi peneliti dari studi terkait. Tidak didapatkan data tambahan.
Hasil: Studi yang melaporkan efektivitas terapi berupa banyaknya jumlah subjek yang mengalami perbaikan atau penurunan skor klinis dan endoskopi dirangkum secara kualitatif. Masing-masing studi saling membahas antar terapi, dan memiliki heterogenitas yang tinggi. Dua studi mengenai formalin dapat dilakukan meta-analisis dengan hasil perbaikan klinis dan endoskopi, namun tidak bermakna terhadap dua studi tersebut (RR 0.97, 95% CI: 0.82-1.15) dan tidak terdapat terapi yang lebih superior dibanding terapi lain dalam meta-analisis tersebut. Empat studi yang membahas formalin 4% memiliki kualitas hasil studi menengah dengan risiko bias rendah. Terdapat 3 dari 9 studi yang membandingkan terapi SCFA dengan plasebo sehingga sulit untuk menyimpulkan terapi mana yang berefek lebih baik, dan memiliki risiko bias tidak jelas, namun dengan jumlah pasien yang sedikitsehingga kualitas studi rendah. Satu studi mengenai efektivitas sukralfat menunjukkan hasil bermakna dengan estimasi risiko rendah (RR 0.57, 95% CI: 0.35-0.92, P = 0.02). Akan tetapi studi mengenai 5-ASA topikal tidak ditemukan dalam inklusi telaah sistematis ini. Secara umum, kualitas hasil studi berdasarkan GRADE dapat dimasukkan ke dalam kategori sedang.
Kesimpulan: Penggunaan terapi SCFA enema, formalin topikal, steroid topikal, dan sukralfat enema efektif dalam memperbaiki gejala klinis dan gambaran endoskopi proktitis radiasi. Namun, hingga saat ini belum ada studi klinis berkualitas baik sehingga sulit untuk menilai terapi yang terbaik. Sedangkan dari 2 studi formalin 4% yang dapat dilakukan meta-analisis, menunjukkan bahwa tidak ada terapi yang lebih superior dibandingkan lainnya. Selain itu, tidak ditemukan tidak ditemukan efek samping berat pada penggunaan terapi SCFA enema, formalin topikal, steroid topikal, dan sukralfat enema dalam mengobati proktitis radiasi.

Background: The high incidence of gynecological and pelvic malignancies has led to the usage of radiation therapy. Nonetheless, radiation therapy also causes a significant complication, about 30% of radiation proctitis. Treatments using topical agents such as SCFA, sucralfate, steroids, formalin, and 5-ASA are known to have good results. However, there are only a few studies comparing the superiority of those therapies.
Objectives: To assess the effectiveness of topical therapies in the clinical and endoscopic improvement of radiation proctitis patients.
Data Sources: Primary searching was conducted on electronic databases such as PubMed, Cochrane/CENTRAL, Scopus, and Science Direct between September and November 2020. Secondary searching was done by snowballing method on the relevant study references and through other certified clinical trial registries (Global Index Medicus, Garba Digital Reference (GARUDA), ClinicalTrial.gov, and WHO's International Clinical Trials Registry Platform (ICTRP).
Study Selection: A randomized controlled trial comparing topical therapies versus placebo or other topical therapies or combination with medical therapies that evaluating the clinical response and endoscopic response. There is no restriction regarding the year of publication and language. Each study were assessed by two independent reviewers. From a total of 1,786 studies identified, 9 studies met the eligibility criteria.
Data Extraction: Data extraction was performed by two independent reviewers and confirmed by a third reviewer. Data confirmation was made by contacting the first researchers from related studies. No additional information was obtained.
Results: Studies reporting the effectiveness of therapy in the form of a large number of subjects experiencing improvement or reduction in clinical symptoms and endoscopy were summarized qualitatively. Each study discussed the therapies and the heterogeneity that could not be calculated due to the different outcomes. Two studies on formalin were subject to meta-analysis with clinical and endoscopy improvement. However, they were not significant in the two studies (RR 0.97, 95% CI: 0.82-1.15), and no better treatment compared with others in those studies. Further, four studies discussing 4% formalin had medium study quality results with a low risk of bias. There are 3 out of 9 studies that compared SCFA therapy with placebo so it is difficult to conclude which therapy has a better effect, and has an unclear risk of bias, but with a small number of patients so that the quality of the study is low. One study using sucralfate showed significant results with a low-risk estimate (RR 0.57, 95% CI: 0.35-0.92, P = 0.02). However, the study of topical 5-ASA was not found in the inclusion of this systematic review. The level of evidence for the majority of outcomes was downgraded using GRADE to a moderate level, due to imprecision and study limitation.
Conclusion: The usage of SCFA enema, topical formalin, topical steroid and sucralfate enema are effective in improving the clinical and endoscopic response in radiation proctitis patient. However, until now, there are no good quality studies, making it difficult to prove the best therapy. A meta-analysis from 2 studies using 4% formalin versus irrigation and antibiotics, shows no therapy is superior to another. Otherwise, no serious side effects were found in the usage of these topical therapies
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2021
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Nuraini Mutrikah
"Tujuan: Membandingkan distribusi dosis respon akhir RE dan efek samping akut RE teknik konvensional dan teknik konformal pada kasus kanker serviks lokal lanjut Metode Dilakukan studi kohort retrospektif terhadap pasien kanker serviks II B dan III B yang mendapat RE pra brakiterapi di Dept Radioterapi RSCM.
Hasil: Didapat 51 pasien menjalani RE teknik konvensional 25 dengan Cobalt 60 26 dengan Linac dan 29 pasien menjalani teknik konformal Sesuai ketentuan ICRU 50 dan 62 prescribed dose dan cakupan volume target teknik konvensional Cobalt lebih kecil p 0 001 dan 1 kasus dari 25 pasien mendapatkan PTV 95 Prescribed dose dan cakupan volume target teknik konvensional Linac lebih besar p 0 001 dibanding teknik konformal Rerata conformity index teknik konvensional sebesar 2 dan teknik konformal 1 02 p 0 001 Dosis dan volume pada buli rektosigmoid dan bowel teknik konvensional lebih besar p 0 001 Respon komplit akhir RE teknik konvensional adalah 42 dan teknik konformal adalah 58 p 0 001 Faktor independen respon akhir RE yaitu stadium FIGO dini dan ukuran tumor sebelum RE kecil le 4cm Pada semua kasus tidak didapatkan efek samping akut lokal yang berat RTOG grade 3 4 Proporsi efek samping ringan RTOG grade 1 2 pada gastrointestinal vesikourinaria dan kulit lebih banyak pada teknik konvensional secara berurutan 72 Vs 28 p 0 002 78 Vs 22 p 0 003 dan 78 Vs 22 p 0 01.
Kesimpulan: RE teknik konformal lebih unggul dibanding teknik konvensional dalam distribusi prescribed dose dan cakupan volume target atau organ kritis yang berdampak pada respon tumor akhir RE dan efek samping.

Purpose: To compare the dose distribution acute tumor response and acute side effects between conventional and conformal techniques EBRT in locally advanced uterine cervical cancerMethods and materials Retrospective cohort study was done in stage II B and III B uterine cervical cancer underwent EBRT before brachytherapy in Dept Radioterapi RSUPN Cipto Mangunkusumo.
Results: Fifety one patients underwent conventional technique EBRT and 29 patients of conformal technique EBRT The average of target prescribed dose and volume coverage of 2 techniques EBRTwas in accordance with criteria of ICRU 50 and 62 smaller p 0 001 only 1 case of Cobalt conventional technique EBRT showed PTV 95 Conformity index of conventional technique EBRT was 2 and conformal technique EBRT was 1 02 p 0 001 Dose and volume of vesicourinary rectosigmoid and distal large bowel of conventional technique EBRT was greater p 0 001 Complete response of conventional technique was 42 and conformal technique was 58 p 0 001 Independent factors were early FIGO stage and tumor size before EBRT le 4cm There were no severe acute side effects RTOG grade 3 4 in both groups Acute side effects RTOG grade 1 2 of conventional techniques was more than conformal gastrointestinal vesikourinaria and skin respectively 72 vs 28 p 0 002 78 vs 22 p 0 003 and 78 vs 22 p 0 01.
Conclusion: Conformal technique EBRT was superior to conventional technique EBRT in prescribed dose distribution target volume coverage and organ at risk dose that impact on acute tumor response and side effects
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2013
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>