Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 16417 dokumen yang sesuai dengan query
cover
"This study investigated the performance of electrocoagulation using iron and aluminum electrodes for removing silica, calcium and magnesium from cooling tower blowdown and reverse osmosis reject waters. Experiments were conducted at both the bench and pilot scales to determine the levels of target species removal as a function of the coadulant dose. At the bench scale, aluminium removed he taget compounds from cooling tower blowdown and reverse osmosis reject more efficiently than iron."
Artikel Jurnal  Universitas Indonesia Library
cover
Yahya Suriah
Depok: Fakultas Teknik Universitas Indonesia, 1992
S35992
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ridwan
Depok: Fakultas Teknik Universitas Indonesia, 2000
S37195
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adityo Purwanto
"Menara pendingin adalah suatu unit yang dugunakan untuk proses pembuangan dalam sebuah sistem pendingin. Efektivitas thermal adalah suatu variabel yang sangat penting untuk menentukan hasil performa menara pendingin. Timbulnya korosi, lumut, dan presipitasi kerak dapat menghambat perpindahan panas sehingga dapat mengganggu tingkat efektivitas thermal dari menara pendingin tersebut. Bukan hanya mengurangi efektivitas termal saja, namun juga bisa merusak menara pendingin. Penelitian ini bertujuan untuk mengetahui pengaruh ozonasi terhadap faktor-faktor penghambat tersebut. Proses ozonasi ini diharapkan akan mengurangi pertumbuhan faktor-faktor tersebut. Metode yang dugunakan adalah dengan air pendingin dari basin disirkulasikan dengan sebuah sistem baru. Dalam sistem baru tersebut air dari basin akan disuntikan ozon, lalu air kembali ke basin. Selanjutnya sampel air akan di uji di laboratorium menggunakan metode AAS, Titrimetric, Gravimetric, Spectrophotometric untuk mengetahui kualitas air. Data yang didapat dari laboratorium adalah Ph, Konduktivitas Elektrik, TDS, Ca, Alkalinitas, Mg, Na, Cl. Data tersebut selanjutnya dimasukan kedalam penghitungan menggunakan metode Practical Ozone ScalingIndex dan Langelier Saturation Index untuk mengetahui kualitas air sirkulasi. Hasil yang didapat dari penelitian ini mununjukan bahwa aplikasi ozon dapat meningkatkan kualitas air dikarenakan TDS dan EC pada air siklus yang digunakan menurun. Jumlah konsentarasi siklus air yang aman digunakan pun meningkat dari 2 siklus menjadi 4 siklus.

cooling tower is a unit that is used for the disposal process in a cooling system. Thermal effectiveness is a very important variable to determine the performance of the cooling tower. The emergence of corrosion, moss, and crustal precipitation can inhibit heat transfer so that it can disrupt the level of thermal effectiveness of the cooling tower. Not only does it reduce thermal effectiveness, but it can also damage the cooling tower. This study aims to determine the effect of ozonation on these inhibiting factors. This ozonation process is expected to reduce the growth of these factors. The method used is with cooling water from the basin circulated with a new system. In the new system water from the basin will be injected with, then the water will return to the basin. Furthermore, water samples will be tested in the laboratory using the AAS, Titrimetric, Gravimetric, Spectrophotometric method to determine water quality. Data obtained from the laboratory are Ph, Electrical Conductivity, TDS, Ca, Alkalinity, Mg, Na, Cl. The data is then entered into the calculation using the Practical Ozone Scaling Index and Langelier Saturation Index method to determine circulating water quality. The results obtained from this study show that the application of ozone can improve water quality because TDS and EC in the cycle water used decrease. The amount of safe water cycle concentration is also increased from 2 cycles to 4 cycles."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Amrullah Farad Sunaryo
"Menara pendingin merupakan satu dari komponen sistem pengkondisian udara yang berperan dalam menjaga suhu yang diinginkan untuk mendapatkan efisiensi yang ingin dicapai.Menara pendingin didefiniskan sebagai alat penukar kalor untuk mendinginkan air dari mesin pendingin melalui kondenser dengan dikontakkan secara langsung dengan air atau udara mengunakan kipas besar. Air dalam sirkulasi menara pendingin sistem tertutup berperan sangat penting sebagai media penukar kalor. Kualitas air yang kurang baik dan penanganan terhadap kualitas air yang kurang tepat dapat menyebabkan korosi dan pengendapan kerak. Korosi dapat merusak material logam dari menara pendingin yang akan menganggu efektivitas perpindahan panas pada pipa. Kerak dapat menghambat proses perpindahan kalor dan akan menyebabkan kenaikan pada konsumsi energi. Salah satu pencegahan terhadap korosi dan kerak ialah melalui ozonasi. Tujuan penelitian ini adalah mengetahui pengaruh penggunaan ozon terhada korosi dan presipitasi kerak melalui indikator Langelier Saturation Index LSI, maksimum konsentrasi dari sirkulasi air tanpa ozon dan menggunakan ozon melalui indikator Practical Ozone Scaling Index (POSI), dan kualitas air melalui Total Dissolve Solid (TDS), Electric Conductivity (EC), dan pH dari air sirkulasi tanpa ozon dan menggunakan ozon. Metode yang digunakan dalam penelitian ini adalah dengan menginjeksikan ozon pada basin dan melakukan uji laboratorium terhadap kualitas air dengan metode AAS, Titrimetri, dan Gravimetri. Hasil yang didapat dari penelitian ini menunjukkan bahwa air sirkulasi menara pendingin tanpa ozon cenderung korosif karena nilai LSI turun dari -5,56 menjadi -6,43 dan air sirkulasi menggunakan ozon dapat menahan laju korosi karena nilai LSI naik dari -6,43 menjadi -5,47. Air sirkulasi tanpa ozon kurang baik karena konsentrasi maksimal dari air tersebut turun dari 1,47 menjadi 1,45 dan air sirkulasi menggunakan ozon mampu menaikkan konsentrasi maksimal dari 1,45 menjadi 1,56. Air sirkulasi tanpa ozon kurang baik karena cenderung mengalami kenaikan nilai TDS dan EC dan air sirkulasi menggunakan ozon cenderung mengalami penurunan pada nilai TDS dan EC. Baik dari air sirkulasi tanpa ozon dan menggunakan ozon, tidak terlalu mempengaruhi pH.

The cooling tower is one of the components of the air conditioning system that plays a role in maintaining the desired temperature to get the efficiency. A cooling tower is defined as a heat exchanger to cool water from a cooling machine through a condenser by direct contact with water or air using a large fan. Water in a closed system cooling tower circulation plays a very important role as a heat exchanger. Poor water quality and improper handling of water quality can cause corrosion and deposition of scale. Corrosion can damage metal material from the cooling tower which will disrupt the effectiveness of heat transfer in the pipe. Crust can inhibit the process of heat transfer and will cause an increase in energy consumption. One of the prevention against corrosion and scale is through ozonation. The purpose of this study was to determine the effect of ozone use on corrosion and crustal precipitation through the Langelier Saturation Index (LSI) indicator, the maximum concentration of circulating water with/without ozone and through the Practical Ozone Scaling Index (POSI) indicator, and water quality through Total Dissolve Solid (TDS) , Electric Conductivity (EC), and the pH of circulating water with/without ozone. The method used in this research is by injecting ozone on basin and conducting laboratory tests on water quality by the AAS, Titrimetry and Gravimetric methods. The results obtained from this study indicate that the cooling tower circulation water without ozone tends to be corrosive because the LSI value drops from -5.56 to -6.43 and that circulating water using ozone can withstand the corrosion rate because the LSI value rises from -6.43 to - 5,47. Circulating water without ozone is not good because the maximum concentration of the water drops from 1.47 to 1.45 and circulating water using ozone can increase the maximum concentration from 1.45 to 1.56. Circulating water without ozone is not good because it tends to increase in TDS and EC values and circulating water using ozone tends to decrease in TDS and EC values. Both of the circulation water without ozone and using ozone, does not greatly affect the pH.
"
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Husni Fadillah
"Cooling tower adalah komponen penting dalam sistem pendinginan industri yang mengandalkan perpindahan panas melalui air. Kualitas air sangat memengaruhi kinerja dan efisiensi sistem. Penelitian ini membandingkan kualitas air cooling tower dengan teknologi ozonasi dan senyawa kimia. Teknologi ozonasi diharapkan menjadi solusi ramah lingkungan dan efektif. Metode penelitian melibatkan analisis sampel air dari cooling tower dengan kedua teknologi, mengukur parameter seperti TDS, blowdown rate, electric conductivity (EC), pH, LSI, RSI, dan POSI. Hasil menunjukkan ozonasi lebih unggul dalam beberapa parameter. TDS dengan ozon turun dari 315,1 ppm menjadi 229,6 ppm, dibandingkan 297,6 ppm dengan bahan kimia. Blowdown rate naik dengan ozon (0,00169 m³/hari menjadi 0,00293 m³/hari) dibandingkan bahan kimia (0,00233 m³/hari). EC dengan ozon menurun dari 525,93 μS/cm menjadi 299,93 μS/cm, sementara bahan kimia meningkat menjadi 610,07 μS/cm. pH dengan ozon stabil (7,27 menjadi 7,28), sedangkan bahan kimia menurun menjadi 7,20. Indeks LSI dan RSI menunjukkan ozon lebih baik dalam mengurangi kerak. POSI juga menunjukkan siklus konsentrasi maksimum lebih tinggi dengan ozon (0,802) dibanding bahan kimia (0,727).

Cooling tower is an important component in industrial cooling systems that rely on heat transfer through water. Water quality greatly affects the system's performance and efficiency. This study compares the water quality of cooling towers with ozone treatment and chemical compounds. Ozone technology is expected to be an environmentally friendly and effective solution. The research method involves analyzing water samples from cooling towers with both technologies, measuring parameters such as TDS, blowdown rate, electric conductivity (EC), pH, LSI, RSI, and POSI. The results show that ozone treatment is superior in several parameters. TDS with ozone decreased from 315.1 ppm to 229.6 ppm, compared to 297.6 ppm with chemicals. Blowdown rate increased with ozone (0.00169 m³/day to 0.00293 m³/day) compared to chemicals (0.00233 m³/day). EC with ozone decreased from 525.93 µS/cm to 299.93 µS/cm, while chemicals increased to 610.07 µS/cm. pH with ozone remained stable (7.27 to 7.28), while chemicals decreased to 7.20. The LSI and RSI indices show ozone is better at reducing scaling. POSI also shows a higher maximum concentration cycle with ozone (0.802) compared to chemicals (0.727). "
Depok: Fakultas Teknik Universitas Indonesia, 2025
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Chevy Cahyana. author
"ABSTRAK
Pengoperasian suatu instalasi pembangkit listrik tenaga termal, baik yang berbahan bakar batubara, minyak bumi maupun energi nuklir, umumnya menggunakan air laut sebagai pendingin. Air pendingin yang masuk kembali ke laut memiliki temperatur di atas temperatur ambien air laut. Masuknya limbah air panas dari kanal pendingin ke laut (thermal pollution) dalam jumlah besar dapat memberikan dampak negatif bagi kehidupan biota laut di sekitarnya. Pengkajian tentang pola sebaran polutan panas dari kanal pendingin pembangkit listrik perlu dilakukan untuk dapat mengetahui luas daerah yang terkena dampak dan berapa besar perubahan temperatur yang terjadi. Simulasi sebaran panas di laut dilakukan dengan mengasumsikan pembangkit listrik
tenaga nuklir dengan kapasitas 7000 MWe beroperasi di Semenanjung Muria Jepara sebagai calon tapak PLTN di Indonesia. Hasil simulasi menunjukkan temperatur sebesar 34-360C menyebar sejauh 115 m, sementara temperatur sebesar 31-330C menyebar sejauh 1048 m dari outlet kanal pendingin.

ABSTRACT
The operation of a thermal power plant, including coal-fired, oil and nuclear energy, use sea water as coolant. Cooling water back into the sea has a temperature above the ambient temperature of sea water. The entry of warm water waste from the cooling canal to the sea (thermal pollution) in large quantities may cause negative impact on marine biota around the canal outlet. Assessment of heat pollutant dispersion pattern from power plant cooling canal needs to be done in order to know the area affected and how much the temperature changes that occur. It is assumed that 7000 MWe nuclear power plant is operated to simulate heat dispersion to ocean water body at Muria peninsula, Jepara as a candidate site of nuclear power plant at Indonesia. The simulation results show that temperature of 34-360C disperse along 115 meters,
meanwhile temperature of 31-330C disperse along 1048 meters from cooling canal outlet.
"
2011
T 29864
UI - Tesis Open  Universitas Indonesia Library
cover
Tarigan, Richardo Elkana
"Pada penelitian ini membahas perbedaan pengaruh media quenching (air,air garam (5% NaCl), dan Oli SAE 5W-40) yang tidak diaduk atau diaduk dengan kecepatan 200 rpm terhadap kecepatan pendinginan,kekerasan,dan struktur mikro dari baja S45C dan D2.Penelitian ini memilih baja S45C dan D2 untuk membedakan pengaruh media pendingin yang signifikan pada baja S45C yang merupakan baja karbon sedang dan baja D2 yang merupakan baja perkakas.Pada penelitian ini sampel awalnya diuji OES untuk mengetahui komposisi baja S45C dan D2 apakah sudah sesuai standar,lalu dilakukan karakterisasi OM dan kekerasan sebelum diquenching,setelah diquenching baja di karakterisasi kecepatan pendinginan,kekerasan,dan struktur mikronya.Hasil penelitian menunjukkan bahwa media pendingin yang di agitasi memberikan pengaruh pada kecepatan pendinginan,struktur mikro dan kekerasan baja.Kecepatan pendinginan air garam(5%NaCl) lebih tinggi dibandingkan dengan air dan oli SAE 5W-40.Proses pengadukan memberikan hasil martensit yang lebih banyak dari pada yang tidak diaduk serta homogenitas struktur mikro yang lebih baik dan mengurangi resiko retak karena distorsi martensite.Baja D2 memiliki kekerasan yang lebih tinggi dari baja S45C karena unsur karbon pada baja D2 lebih tinggi dibandingkan dengan baja S45C,ditambah unsur Paduan yang lebih banyak pada baja D2 dibandingkan S45C membuat hidung CCT diagram baja D2 jauh lebih kekanan dari pada baja S45C.Hal ini mengakibatkan baja D2 lebih mudah membentuk martensit dibandingkan dengan baja S45C.Penelitian ini dapat disimpulkan bahwa kombinasi media quenching dan agitasi yang tepat akan menghasilkan sifat mekanik baja yang optimal untuk aplikasi industri.

This study discusses the differences in the effects of quenching media (water, saltwater (5% NaCl), and SAE 5W-40 oil) with and without agitation at 200 rpm on the cooling rate, hardness, and microstructure of S45C and D2 steels. The study selects S45C and D2 steels to differentiate the significant effects of cooling media on S45C, a medium-carbon steel, and D2, a tool steel. In this study, the initial samples were tested using OES to determine whether the chemical composition of S45C and D2 met the standard, followed by optical microscopy (OM) and hardness characterization before dequenching. After dequenching, the steel samples were characterized for cooling rate, hardness, and microstructure. The results showed that agitated quenching media had an effect on the cooling rate, microstructure, and hardness of the steel. Saltwater (5% NaCl) had a higher cooling rate than water and SAE 5W-40 oil. The agitation process resulted in a greater amount of martensite compared to the non-agitated samples, along with better microstructural homogeneity and reduced risk of cracking due to martensite distortion. D2 steel exhibited higher hardness than S45C steel due to the higher carbon content in D2 compared to S45C, along with a greater amount of alloying elements in D2. This made the CCT diagram for D2 shift significantly to the right compared to S45C, making D2 more susceptible to martensite formation. In conclusion, the study suggests that the proper combination of quenching media and agitation can optimize the mechanical properties of steel for industrial applications. "
Depok: Fakultas Teknik Universitas Indonesia, 2025
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rafif Roid Shiddiq
"Bucket tooth pada alat berat excavator menggunakan baja High Strength Low Alloy sebagai material didasari oleh sifat-sifatnya. Perlakuan panas yang dilakukan pada baja HSLA adalah normalisasi, tempering, austenisasi, dan quenching, serta double tempering. Penemuan Delay Crack pada produk bucket tooth yang disebabkan oleh adanya austenit sisa pada komponen bucket tooth, austenite ini menimbulkan tegangan sisa di dalam produk. Meminimalisir jumlah austenite sisa serta keseragaman mikrostruktur adalah langkah yang tepat untuk mencegah Delay Crack. Penelitian ini berfokus pada kualifikasi kecepatan pendinginan media pendingin berupa air, air hangat, dan oli dan meneliti pengaruhnya terhadap struktur mikro dan kekerasan baja HSLA. Kecepatan pendinginan rata-rata yang paling tinggi secara berurutan adalah air, oli, dan air hangat, senilai 111,28 oC/s, 51.30 oC/s, 56.75 oC/s. Perbedaan kecepatan pendinginan akan menghasilkan struktur mikro baja HSLA yang berbeda. Fasa martensite terbentuk paling dominan pada setiap jenis media pendingin dengan sedikit austenite sisa yang kadarnya meningkat seiring dengan meningkatnya kecepatan pendinginan yaitu 0.8%, 2,4%, 3% . Kekerasan mikro menemukan fraksi area transformation zone keras akibat dikelilingi oleh martensite pada setiap baja, fasa lower bainite pada baja media pendingin air hangat, serta karbida pada baja media pendingin Air suhu kamar. Nilai kekerasan makro untuk tiap sampel meningkat seiring meningkatnya kecepatan pendinginan, yaitu secara berturut turut menjadi 49.1 HRC, 47.1 HRC, dan 44.3 HRC. Sehingga meningkatnya kecepatan pendinginan menyebabkan peningkatan kekerasan dan kadar austenite sisa. Beberapa temuan lainnya seperti dekarburisasi pada permukaan baja di analisis untuk mengetahui penyebab delay crack terjadi.

Excavator’s bucket tooth using High Strength Low Alloy Steel based material because of it’s properties. The heat treatment performed on HSLA steel is normalization, tempering, austenisation, and quenching, and the last double tempering. Delay Crack was discovered on bucket tooth products caused by the presence of retained austenite in the bucket tooth component, this austenite raises residual stresses in the product. Minimizing the amount of retained austenite and gaining microstructural uniformity is the right step to prevent Delay Crack. This research focuses on qualifying the cooling rate of quenching media in the form of water, hot water, and oil then examines their effects on the microstructure and hardness of HSLA steels. The highest average cooling speed, respectively, is water, oil and warm water, valued at 111.28 oC / s, 51.30 oC / s, 56.75 oC / s. The difference in cooling speed will produce a different HSLA steel microstructure. Martensite phase is formed dominantly in every quenching media variables with a little content of retained austenite whose levels increase with increasing cooling rate by 0.8%, 2.4%, 3%. Microhardness Testing found a hard zone named transformation zone fraction due to being surrounded by martensite in each variables, lower bainite phase in hot water variable, and carbide in water variable. The value of macro hardness for each sample increased with increasing cooling rate, which became 49.1 HRC, 47.1 HRC, and 44.3 HRC respectively. So that the increase in cooling rate causes an increase in hardness and residual austenite levels. Several other findings such as decarburization on the steel surface are analyzed to determine the cause of the delay crack.
"
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Refi Kunaefi
"Fluida pendingin dan pemanas adalah dua hal penting untuk banyak sector industri, termasuk bidang energi, transportasi dan manufaktur. Thermal conductivity dari fluida tersebut memainkan peranan penting dalam perkembangan peralatan penukar kalor yang efisien.
Dalam industri manufaktur, khususnya industri pemesinan logam (metal cutting), fluida pendingin mempunyai pengaruh besar dalam menentukan kualitas kekasaran permukaan (surface roughness) hasil pemesinan. Kekasaran permukaan adalah parameter utama yang (selalu) digunakan setelah ketepatan dimensi-toleransi untuk menyatakan kualitas hasil pemesinan. Kekasaran permukaan suatu produk pemesinan dapat mempengaruhi beberapa fungsi produk seperti gesekan permukaan (surface friction), perpindahan panas, estetika, dan lain-lain. Beberapa metode yang sering digunakan untuk meningkatkan kualitas kekasaran permukaan adalah: pengaturan kecepatan potong, material pahat potong, kedalaman pemotongan (depth of cut), dan penggunaan fluida pendingin (cooling fluid) konvensional.
Penelitian ini bertujuan untuk meningkatkan kualitas permukaan hasil pemesinan dengan cara mengganti fluida pendingin konvensional dengan nanofluida. Nanofluida adalah material komposit padatan-cairan yang mengandung nano partikel atau nano fiber (serat nano) dengan ukuran pada umumnya 1-100 nm yang larut dalam cairan; air, minyak, atau ethilene glycol [Pawel Geblinski, Jeffrey A.Eastman, David G. Cahill, 2005]. Jumlah yang sangat kecil dari nano partikel, dapat meningkatkan secara signifikan karakteristik termal dari fluida dasar.
Banyak publikasi yang menyebutkan bahwa penggunaan nanofluida dapat memperbaiki karakteristik termal suatu fluida pendingin?khususnya peningkatan konstanta perpindahan panas, heat transfer coefficient. Fenomena inilah yang penulis manfaatkan pada proses metal cutting. Hasil pengujian menunjukkan peningkatan karakteristik perpindahan panas. Selain itu, penggunaan nanofluida yang dicampur dengan lubricant mampu menghasilkan kualitas kekasaran permukaan produk yang lebih baik dibanding dengan pendingin konvensional yang banyak digunakan saat ini. Kata kunci: nanofluida, thermal conductivity, kekasaran permukaan.

Cooling and heating fluid are two important things for many industry fields, such as energy field, transportaion, and manufacture. The thermal conductivity of this fluid has important role in developing an efficient heat exchanger device.
In manufacturing, especially metal cutting industry, cooling fluid has significant effect in determining the surface roughness of the machining product. Beside dimension accuracy, surface roughness is main parameter which is always used for scoring the quality of machining product. Surface roughness of machining product can influence some of product function: surface friction, heat transfer, aestetic, etc. Many methods have been developed to enhance surface roughness quality of the product within adjusting machining parameter: cutting speed, type of cutting tool, depth of cut, and using various cooling fluid system.
This research?s purpose is increasing surface roughness quality of machining product by changing conventional cooling fluid with nanofluids. Nanofluids is novel fluid which contains nano particle (1-100 nm in dimension). This nano particle can be solved in liquid such as water, oil, and ethylene glycol [Pawel Geblinski, Jeffrey A.Eastman, David G. Cahill, 2005]. Low concentration of nano particle in liquid can significantly enhance the thermal characteristic of the base fluid.
There are many publication state that nanofluids can improve thermal charactistic of cooling fluid?especially enhanching heat transfer coefficient. Due to this phenomenon, writer has the idea to use this nanofluid in metal cutting process. Laboratory investigation show increasing in heat transfer characteristic of nanofluid in metal cutting process. Then, combination nanofluid with lubricant with 3.3 % volume can produce better surface roughness quality of metal cutting product compare with conventional cooling fluid."
2008
S37312
UI - Skripsi Open  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>