Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 8370 dokumen yang sesuai dengan query
cover
Greenstein, Caren E.
Philadelphia: Wolters Kluwer, 2011
R 618.19 GRE b
Buku Referensi  Universitas Indonesia Library
cover
Deka, Bhabesh
"This book presents a comprehensive review of the recent developments in fast L1-norm regularization-based compressed sensing (CS) magnetic resonance image reconstruction algorithms. Compressed sensing magnetic resonance imaging (CS-MRI) is able to reduce the scan time of MRI considerably as it is possible to reconstruct MR images from only a few measurements in the k-space; far below the requirements of the Nyquist sampling rate. L1-norm-based regularization problems can be solved efficiently using the state-of-the-art convex optimization techniques, which in general outperform the greedy techniques in terms of quality of reconstructions. Recently, fast convex optimization based reconstruction algorithms have been developed which are also able to achieve the benchmarks for the use of CS-MRI in clinical practice. This book enables graduate students, researchers, and medical practitioners working in the field of medical image processing, particularly in MRI to understand the need for the CS in MRI, and thereby how it could revolutionize the soft tissue imaging to benefit healthcare technology without making major changes in the existing scanner hardware. It would be particularly useful for researchers who have just entered into the exciting field of CS-MRI and would like to quickly go through the developments to date without diving into the detailed mathematical analysis. Finally, it also discusses recent trends and future research directions for implementation of CS-MRI in clinical practice, particularly in Bio and Neuro-informatics applications."
Singapore: Springer Nature, 2019
e20507352
eBooks  Universitas Indonesia Library
cover
Berry, Elizabeth
Boca Raton: CRC Press, Taylor & Francis Group, 2009
616.075 48 BER f
Buku Teks SO  Universitas Indonesia Library
cover
Berry, Elizabeth
Boca Raton: Taylor & Francis Group, 2009
616BERF001
Multimedia  Universitas Indonesia Library
cover
Runge, Val M.
"The objective of this book is to serve as a practical educational resource for clinical magnetic resonance imaging. The bulk of the text is organized along anatomic lines and discusses disease entities commonly encountered in clinical practice. The focus is illustrating and describing the MR appearances of the most commonly imaged disease entities, covering briefly in each area important points relative to imaging techniques then discussing in depth, the clinical MR interpretation. The breadth of clinical MRI is explored. For each subtopic within an anatomic region, clinical cases serve as the backbone for discussion, the most common pathologies affecting each anatomic region being illustrated. The final chapters discuss specifically contrast media and contrast enhanced MRA, two topics worthy of further description due to their present clinical importance. When relevant to diagnosis or essential for understanding, MR physics is discussed, however the reader is referred separately to Runge et al, The Physics of Clinical MR Taught Through Images 2nd Edition (New York: Thieme; 2009) for further elaboration. It is the goal that upon completing this text, the reader will have an appreciation for the complexity, utility, and versatility of MR in clinical imaging and will possess the knowledge essential for interpretation of basic clinical MR "
New York: Thieme, , 2011
616.075 48 RUN e
Buku Teks SO  Universitas Indonesia Library
cover
Lingga Magdalena Sulaiman
"TUJUAN. Mengetahui akurasi MRI 0,5T dalam mendeteksi ruptur meniskus.
BAHAN DAN CARA. Selama kurun waktu 6 bulan (Oktober 2004 sampai dengan Maret 2005) dilakukan pemeriksaan MRI terhadap 19 pasien (20 lutut) dengan klinis ruptur meniskus. Pemeriksaan MRI menggunakan MRI 0,5T superkondukting magnet, Bruker Tomikom, buatan Perancis tahun 2000 dan closely coupled extremity coil dengan teknik konvensional spin-echo T1W1 dan T2WI potongan sagital dan koronal. Dua kriteria MRI dalam mendiagnosis ruptur meniskus adalah adanya signal hiperintens intrameniskus pada T1W1 dan T2W1 yang dapat meluas ke permukaan sendi, ditemukannya morfologi meniskus yang abnormal seperti adanya perubahan kontur atau deformitas fokal meniskus. Untuk mempertajam diagnosis digunakan sistem penderajatan meniskus berdasarkan signal intrameniskus. HasiI pemeriksaan MRI dibandingkan dengan temuan artroskopi sebagai baku emas.
HASIL. Sensitivitas, spesifisitas MRI 0,5T dalam mendeteksi ruptur meniskus adalah 84,4% dan 85,7% dengan akurasi 84,6%. Terdapat kesesuaian yang baik antara MRI 0,5T dengan artroskopi (k-D,573)
KESIMPULAN. MRI 0,5T merupakan modalitas pencitraan non invasif yang mempunyai sensitivitas dan akurasi yang tinggi yang dapat digunakan untuk mendiagnosis adanya ruptur meniskus.
Kata kunci : Ruptur meniskus, MRI, artroskopi.

OBJECTIVE The purpose of this study was to evaluate the accuracy of MR imaging 0,5T in detecting meniscal tears.
MATERIALS AND METHOD& During an 6 months period (October 2004 until March 2005), 19 patients (20 knees) who had meniscal tears identified at physical examinations underwent MR imaging examinations. MR imaging was performed with a 0,5T (superconducting; Bruker Tomikom, France, 2000) and a closely coupled extremity coil, conventional spin-echo pulse sequences were used in sagital and coronal planes TI and T2 weighted images. Two MR imaging criteria to established the diagnose of meniscal tears were increased internal signal intensity in the meniscus on TI and T2-weighted images, abnormal morphology of the meniscus such as contour or focal deformities of the meniscus. To increase the accuracy of MR imaging, meniscal were grading according to the character of the intrameniscal MR imaging signal. MR imaging finding was compared with arthroscopic results as the standard of reference.
RESULTS. Sensitivity, specificity and accuracy MR imaging 0,5T for detecting meniscal tears were 84,4%, 85,7% and 84,6%. There is good correlation of MR imaging and arthroscopic findings (kappa = 0,573).
CONCLUSION. MR imaging is a non-invasive modality with high sensitivity and accuracy which can used in detecting meniscal tears.
Key wards : Meniscal tears, MR Imaging, arthroscopic.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2005
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Agus Sun Sugiharto
"Tesis ini membahas tentang analisis dari perancangan divais dioda tunnel dari bahan silikon yang dipabrikasikan dengan menggunakan teknologi planar. Pabrikasi divais disesuaikan dengan teknologi peralatan dan bahan yang tersedia pada Laboratorium Mikroelektronika Puslitbang TELKOKA LIPI Bandung sebagai tempat proses pembuatan. Dalam tesis ini dirancang 3 divais dioda tunnel, dengan berbagai konsetrasi impurity lapisan tipe n+, tetapi bentuk dan ukuran geometrinya sama. Ketiga rancangan tersebut disimulasikan dengan program perangkat lunak SPICES2B, MATLAB dan UIHKCAD untuk memperoleh kurva karakteristik I-V dan hubungan antara konsentrasi impurity bahan dengan unjuk kerja untuk sinyal kecil. Unjuk kerja tersebut meliputi figure of merit, daya maksimum dan efisiensi. Ketiga rancangan dipabrikasi menggunakan teknologi difusi planar, parameter proses yang dipakai dari basil simulasi program perangkat lunak SSUPREM. Hasil simulasi menunjukkan suatu karakteristik divais yang apabila konsentrasi impurity pada bahan tipe n+ (HD) dinaikkan, maka performasi dari dioda tunnel meningkat. Setelah dipabrikasi dan diukur, divais telah menunjukkan fenomena dioda tunnel."
Depok: Fakultas Teknik Universitas Indonesia, 1996
T40680
UI - Tesis Membership  Universitas Indonesia Library
cover
Ho Natalia
"Tujuan: Penelitian ini dilakukan untuk mengetahui korelasi perubahan nilai ADC pada DWMRI dengan perubahan ukuran tumor pasca kemoterapi neoajuvan kanker payudara dalam menilai respons kemoterapi neoajuvan.
Metode: Penelitian studi deskriptif analitik dari data sekunder MRI pasien kanker payudara yang mendapat kemoterapi neoajuvan serta menjalankan pemeriksaan MRI. Pemeriksaan MRI dilakukan sebelum pasien mendapat kemoterapi neoajuvan, setelah pasien mendapat kemoterapi neoajuvan siklus pertama dan siklus ketiga. Pengukuran ukuran tumor dilakukan sesuai standar RECIST, sedangkan nilai ADC diperoleh pada nilai b800s/mm2.
Hasil dan diskusi: Dilakukan analisis bivariat dengan menggunakan korelasi Pearson untuk melihat korelasi perubahan nilai ADC kedua terhadap nilai ADC pertama dengan perubahan ukuran tumor pada pemeriksaan MRI ketiga terhadap pemeriksaan MRI pertama. Sebanyak 17 pasien penelitian dengan usia antara 40 tahun sampai 65 tahun dan ukuran tumor antara 5,41 cm sampai 13,41 cm. Terdapat 16 pasien yang mengalami peningkatan nilai ADC dan 1 pasien yang mengalami penurunan nilai ADC setelah pemberian kemoterapi neoajuvan siklus pertama. Sebanyak 17 pasien mengalami pengurangan ukuran tumor setelah kemoterapi neoajuvan siklus ketiga. Berdasarkan standar RECIST diperoleh sebanyak 7 pasien dengan pengurangan ukuran tumor lebih dari 30% (antara 31,55% sampai 56,25%) dan sebanyak 10 pasien dengan pengurangan ukuran tumor kurang dari 30% (antara 7,47% sampai 29,22%). Nilai korelasi yang diperoleh sebesar -0,499.
Kesimpulan: Terdapat korelasi yang bermakna antara perubahan nilai ADC pada DWMRI dengan perubahan ukuran tumor sebagai respons kemoterapi neoajuvan kanker payudara dengan kekuatan korelasi yang sedang dan arah negatif.

Objectives: To determine the correlation of changes in ADC values in DWMRI with changes in tumor size after neoadjuvant chemotherapy in breast cancer to assess neoadjuvant chemotherapy response.
Methods: Analytical descriptive study using secondary data from MRI of breast cancer patients receiving neoadjuvant chemotherapy as well as running an MRI. MRI examination performed before neoadjuvant chemotherapy, after received first cycle neoadjuvant chemotherapy and third cycle. Tumor size measurements carried out according to standard RECIST, whereas the ADC values obtained in the b800s/mm2. Bivariate analysis using Pearson correlation was conducted to determine the correlation of changes in the value of the second ADC to first ADC and changes of the tumor size on the third MRI to the first MRI examination.
Result and discussion: A total of 17 study patients, 40 years to 65 years old, tumor size between 5.41 cm to 13.41 cm. 16 patients experienced an increase in ADC values while 1 patient had decreased ADC values after the first cycle of neoadjuvant chemotherapy. Tumor size in all patients decreased after three cycles of neoadjuvant chemotherapy. Based on RECIST standards, 7 patients showed tumor size reduction of more than 30% (between 31.55% to 56.25%) and tumor size in 10 patients was reduced less than 30% (between 7.47% to 29.22% ). Correlation value of -0.499 obtained.
Conclusions: There is a significant moderate and negative correlation between in ADC value changes in DWMRI with tumor size changes in response to neoadjuvant chemotherapy.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2013
T31952
UI - Tesis Membership  Universitas Indonesia Library
cover
Arwan Priatna
"Pada skripsi ini dirancang sebuah resonator RF Birdcage Coil tanpa lumped circuit untuk aplikasi sistem Magnetic Resonance Imaging (MRI). MRI merupakan teknologi pencitraan tubuh manusia untuk aplikasi diagnosis medis yang bersifat non-invasive dan tidak memiliki pengaruh radiasi foton seperti halnya yang terdapat pada sistem Computed Tomography (CT). MRI memanfaatkan efek kuat medan magnet untuk mensejajarkan susunan inti atom hidrogen (proton) dengan arah medan magnet eksternal. Pada saat yang bersamaan sistem memancarkan RF Pulse ke tubuh pasien kemudian menerima sinyal Magnetic Resonance (MR) untuk rekonstruksi citra penampang tubuh.
Pada penilitian ini dirancang suatu resonator RF Birdcage Coil tanpa lumped circuit yang beresonansi di spektrum frekuensi 128 MHz. Secara desain, resonator ini dirancang terdiri atas Leg dan End Rings (ERs) terbuat dari selembar konduktor tembaga tipis yang ditempelkan di kedua sisi akrilik sebagai material substrat untuk memberikan nilai kapasitansi resonator dan sekaligus sebagai pembentuk konfigurasi resonator RF Birdcage Coil. End Rings disusun superposisi untuk membentuk kapasitor secara bergantian. Untuk mendapatkan frekuensi resonansi yang diinginkan, dilakukan tuning dengan cara memperbesar atau memperkecil dimensi plat tembaga End Rings untuk mengubah nilai kapasitansi resonator.
Desain resonator dirancang dengan menggunakan perangkat lunak Birdcage Builder untuk menghitung nilai kapasitansi awal dan disimulasikan dengan perangkat lunak berbasis Finite Integration Technique (FIT). Setelah dilakukan validasi dengan cara pengukuran tanpa ada tubuh manusia, resonator dapat beresonansi di frekuensi 128,5 MHz. Pengujian resonator dengan memasukkan bagian tubuh manusia seperti kepala dan tangan, resonator memberikan response perubahan yang sangat kecil pada pergeseran frekuensi berturut-turut 128,8 MHz dan 127,7 MHz untuk kepala dan tangan manusia.

In this final project the RF Birdcage Coil resonator is designed without using lumped circuit for application of Magnetic Resonance Imaging (MRI) system. MRI is a scanning technology of human body tissues to medical diagnosis application which generally is non-invasive and doesn’t has the impact of photon like another system such as Computed Tomography (CT). It utilizes the effect of magnetic field strength to aligns proton with external magnetic field and transmits the RF Pulse to the human body then recieves the Magnetic Resonance (MR) signal for image reconstruction simultaneously.
In this research the RF Birdcage Coil resonator is designed without using lumped circuit and it can resonance in 128 MHz. This resonator has the Leg and End Rings which is made from copper foil and attached to the inner and outer of acrylic as a substrat material to produce the capacitance of the resonator and also as a shaper of the RF Birdcage Coil’s configuration. The End Rings arrange superposition to create the capacitance respectively. To get desired resonance frequency it should be tuned by make dimension foil of End Rings bigger or smaller to change the capacitance.
Birdcage Builder as a software which used to design the beginning form of the resonator and count the first value of capacitance then simulated in software based on Finite Integration Technique. After validation with measurement without human body the resonator can resonance in 128,5 MHz. Measurement with import body parts such as head and hand into resonator give the smallest change in 128,8 MHz and 127,7 MHz for human head and hand respectively.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S47679
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dhany Wicaksono
"Pada saat ini, teknologi elektromagnetik terapan telah digunakan di berbagai bidang, termasuk di bidang kesehatan. Teknologi ini banyak diaplikasikan untuk melakukan proses analisa suatu penyakit atau bahkan melakukan penyembuhan. Dari banyak kegunaan itu, salah satu aplikasi teknologi elektromagnetik terapan di bidang medis adalah sistem pencitraan penampang tubuh. Dari beberapa instrumen kesehatan yang berfungsi untuk menampilkan pencitraan penampang tubuh, Magnetic Resonance Imaging (MRI) memiliki keunggulan untuk melakukan pencitraan organ-organ lunak. Pengaplikasian teknologi MRI terus berkembang hingga sekarang termasuk teknik penggunaan RF Coil Resonator yang terdapat di sistem MRI.
Pada skripsi ini akan dirancang bangun sebuah RF Coil Resonator untuk sistem MRI 3 Tesla agar dapat menghasilkan citra atau penggambaran dari objek yang lebih jelas dan dapat digunakan oleh tenaga medis seperti dokter sebagai acuan untuk menganalisa suatu jaringan lunak yang bermasalah.
Penelitian ini merancang sebuah resonator phased array yang terdiri dari 8 elemen yang bekerja pada frekuensi 127,7 MHz. Berdasarkan hasil simulasi, resonator tersebut memiliki keseragaman medan magnet dan nilai Specific Absorption Rate (SAR) dibawah ambang batas aman yaitu 0,195 W/kg.
Diharapkan hasil rancangan ini dapat bekerja secara paralel untuk meningkatkan fungsionalitas dan kemampuan sistem MRI yang menghasilkan suatu citra yang lebih baik dan waktu scanning yang lebih cepat dibandingkan dengan resonator konvensional. Resonator phased array coil ini telah difabrikasi dan diukur parameter S-parameter dengan hasil yang sesuai dengan hasil simulasi pada frekuensi kerja 127,67 MHz.

Currently, applied electromagnetic technology has been used in various fields, including for health sector. This technology is widely adopted for disease diagnosis as well as for treatment. One of several applications in applied electromagnetic technology is imaging system for medical field application. One of medical instruments which are used for body imaging system, that is Magnetic Resonance Imaging (MRI), has the advantage to create an image of soft organ. Application of MRI technology continues to evolve up until now, including the development of RF Coil Resonator techniques for MRI systems.
In this thesis, a RF Resonator Coil for 3 MRI 3 Tesla system is designed in order to produce high-resolution images, so it can be used by medical personnel such as doctors to analyze the soft tissue problems.
In this study, a RF phased array resonator that consists of 8 elements is designed for working at the frequency of 127.7 MHz. According to the simulation results, the resonator has uniform magnetic field and low value of Specific Absorption Rate (SAR) below the safety threshold by 0.195 W / kg.
It is expected that this design is able to operate for parallel operation in order to increase the functionality and capability of the MRI system can produces a better image and a faster scanning time in comparison with the conventional resonator one. The phased array coil resonator has been fabricated and measured, where the Sparameter results agree with the simulation results at the operation frequency 127.67 MHz.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S45728
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>