Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 348 dokumen yang sesuai dengan query
cover
Andonyev, S.M.
Moscow: Mir, 1976
669.8 AND e
Buku Teks  Universitas Indonesia Library
cover
Kazantsev, E. L.
New York: John Wiley & Sons, 1961
621.182 KAZ i (1)
Buku Teks  Universitas Indonesia Library
cover
R. Evi Sofia
"Sebagian besar penelitian tentang evaporative cooling hanya berfokus pada proses termodinamika dan optimalisasi kinerja beberapa konfigurasi dasar, seperti direct evporative cooling (DEC) dan tipe tubular atau plat indirect evaporative cooling (IEC). Penelitian mengenai beberapa teknologi evaporative cooling terbaru seperti heat pipe IEC, dew point IEC dan semi indirect evaporative cooling, masih sedikit dilakukan. Penelitian ini bertujuan untuk mengembangkan sistem pengkondisian udara yang menggunakan indirect evaporative cooling yang dikombinasikan dengan finned heat pipe sebagai pemindah panas dan cooling pad dari bahan serat alami. Tahapan awal dilakukan dengan melakukan studi literatur mengenai indirect evaporative cooling dan heat pipe, melakukan evaluasi terhadap penelitian yang pernah dilakukan, melakukan pengujian terhadap karakteristik finned heat pipe yang akan digunakan, melakukan penelitian terhadap bahan media pendingin berbahan serat alami yang akan digunakan, merancang bangun kombinasi indirect evaporative cooling dan finned heat pipe dengan media pendingin berbahan serat alami. Selain itu pada penelitian ini juga akan dicari beberapa hubungan atau korelasi antara parameter-parameter yang ada pada indirect indirect evaporative cooling dengan tujuan meningkatkan efektifitasnya. Hasil dari pengujian ini menunjukkan bahwa efektivitas indirect evaporative cooling meningkat ketika digunakan serat alami berbahan nanas dibandingkan dengan serat lain (rami dan luffa), nilai maksimumnya 90% untuk efektivitas wet bulb dan 71% untuk efektivitas dew point, serta nilai EER yang mencapai 62%. Selain itu kinerja finned heat pipe sebagai pemindah panas bekerja dengan baik pada sistem ini terbukti dengan nilai kapasitas pendinginan maksimum yang mencapai 1180W.

The majority of evaporative cooling research only considers the thermodynamic operations and performance enhancement of a few fundamental configurations, such as direct evaporative cooling (DEC) and indirect evaporative cooling (IEC) tubular or plate kinds. There is still little research on some of the most recent evaporative cooling techniques, including indirect evaporative cooling (IEC) heat pipes, indirect evaporative cooling (IEC) dew points, and semiindirect evaporative cooling. With the use of finned heat pipes for heat transfer, cooling pads made of natural fibers, and indirect evaporative cooling, an air conditioning system is being developed. The first stage involves researching indirect evaporative cooling and heat pipes in the literature, assessing previous research, testing potential finned heat pipe characteristics, researching potential cooling media materials made of natural fibers, and designing buildings with a combination of indirect evaporative cooling and finned heat pipes and a natural fiberbased cooling medium. In addition, this study will look for connections or correlations between the present indirect evaporative cooling factors in an effort to increase its efficiency. The results of this test demonstrate that using natural fibers made from pineapple increases the effectiveness of indirect evaporative cooling when compared to other fibers (ramie and luffa); the maximum value is 90% for the wet bulb effectiveness and 71% for the dew point effectiveness, and the EER value reaches 62%. Additionally, this system effectively transfers heat thanks to the finned heat pipes, as shown by the maximum cooling capacity of 1180 W."
Depok: Fakultas Teknik Universitas Indonesia, 2023
D-pdf
UI - Disertasi Membership  Universitas Indonesia Library
cover
Bambang Ali Gunawan
"Konduktivitas termal menunjukkan seberapa cepat panas mengalir pada bahan tertentu pada pengujian ini bahan yang akan diuji menggunakan serat luffa sebagai cooling pad yang diaplikasikan pada sistem evaporative cooling. Untuk mengetahui nilai panas yang dipindahkan dari heat pipe ke cooling pad pada alat evaporative cooling yang ditambahkan heat pipe perlu diketahui termal konduktivitas dari serat yang akan dijadikan media pendingin. Penelitian ini memiliki tujuan untuk mengetahui nilai konduktivitas termal dari serat luffa dengan menggunakan alat konduktivitas termal berbasis termoelektrik dan mengetahui kinerja dari evaporative cooling berbasis finn heat pipe. Metode yang digunakan yaitu metode axial flow dengan variasi temperatur 35-50 oC. Sedangkan variasi temperatur pada evaporative cooling digunakan untuk mengetahui kinerja dari sistem evaporative cooling pada temperatur 35-45 oC pada udara masuk sistem serta variasi temperatur air 20 oC dan 25 oC pada cooling pad. Berdasarkan hasil pengujian diperoleh bahwa nilai konduktivitas termal pada temperatur 35 oC dari serat luffa sebesar 0,0459 W/mK dan serat luffa sebesar 0,1746 W/mK. Berdasarkan hasil perhitungan diperoleh bahwa nilai untuk nilai penurunan temperatur terbesar yang didapat 6,67°C, effectiveness wet bulb 49,94%, effectiveness dew point 37,99% kemudian untuk EER 6,32.

Thermal conductivity evaluates how fast heat flow through with a bahan once it is tested using luffa fiber as a cooling 1,1 m/sfor the cooling pad used for an evaporative cooling system. The thermal conductivity of the fiber that will be used as the cooling 1,1 m/sshould be known in determining the value of heat transferred from the heat pipe to the cooling 1,1 m/sin the evaporative cooler with the extra heat pipe. The purpose of this research is to use a thermoelectric-based Ogawa Saiki thermal conductivity instrument to determine the thermal conductivity value of luffa fiber and to evaluate the performance of finn heat pipe-based evaporative cooling. The axial f0,4 m/s method was used, with a temperature variation of 35-50 oC while the temperature variation in evaporative cooling is used to determine the performance of the evaporative cooling system at a temperature of 35-45oC in the air intake system and variations in air temperature of 20 oC and 25oC on the cooling pad cooling media, the temperature variation in evaporative cooling is used to determine the performance of the evaporative cooling system at a temperature of 35-45oC in the air intake system and variations in air temperature of 20oC and 25oC. The thermal conductivity value of luffa fiber at a temperature of 35oC was 0.0459 W/mK, while luffa fiber was 0.1746 W/mK, according to the test. According to the calculations, the value for the largest temperature drop is 6.67°C, the wet bulb effectiveness is 49.94 %, the dew point effectiveness is 37.99 %, as well as the EER is 6.32."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Jain, Surender Kumar
New Delhi: Vikas Publishing House PVT LTD, 1982
669.9 JAI i
Buku Teks  Universitas Indonesia Library
cover
Upadhyaya, G.S.
Oxford: Pergamon Press, 1977
669.9 UPA p
Buku Teks  Universitas Indonesia Library
cover
Nemenyi, R.
Oxford: Pergamon Press, 1984
671.36 NEM c (1)
Buku Teks  Universitas Indonesia Library
cover
Mochammad Renaldy Abdurachman
"Pengkondisian udara dengan maksud untuk mengatur nilai temperatur dan kelernbaban udara sangat penting untuk mendapatkan suatu udara yang nyaman bagi ma usia dan mandukung proses industri. Dengan metode pandinginan evaponatif udara dapat dikondisikan agar mempunyai temperatur dan kelembaban relatif yang tartentu.
Pendinginan evaporatif bertujuan untuk menurunkan temperatur bola kenng udara dan menaikkan kelembaban relatif dengan temperatur bola basah yang konstan. Tujuan penufisan skripsi ini adalah untuk mengetahui unjuk kerja dari alat eksperimen pendingin evaporatif iangsung dengan menvanasikan peletakan penyearah aIiran pada posisi 0 cm dan dimajukan sejauh 20 cm dan posisi awal.
Alat eksperimen pendingin evaporatif langsung dengan menggunakan fan sentrifuga! sebgai komponen pengolah udara untuk menghembuskan udara melewati media basah yang dibasahi oleh air. Dengan melakukan pengujian pada alat eksperimen didapafkan data-data temparatur bola kering dan temperatur bola basah.
Dari data-data tersebut dilakukan perhitungan-perhitungan dengan rumus-rumus yang diketahuf dan diagram psikometri. Dan hasil pengujian didapatkan penumnan iemperatur bola kering yang disertai juga dengan penurunan temperatur bola basah sehingga kelembaban relatif udara tersebut juga rnengalami penurunan Dan hasif parhitungan juga didapat penumnan nano humiditas yang berarti kandungan uap air dafam udara berkurang atau berubah menjadi aiu Kesalahan pengujian disebabkan oleh kesalahan pengukuran temperatur bofa basah dengan menggunakan termokopal, dimana penempatan dan penggunaan kain basah sebagai pembasah tidak bekerja dengan efektif.
Alat eksperimen menunjukkan penurunan temperatur bola kering rata-rata sebesar 0,88 °C, temperatur bofa basah sabesar 0,38 °C pada posisi penyearah aliran di 0 Cm dan efisiensi alat rata-rata 31,3% Pada saat penyearah aliran dimajukan sejauh 20 Cm penurunan temperatur bola kering dan bola basah terjadi rata-rata sebesar 0,2"C dan 0,73 ?C sehingga didapatkan elisiensi alat rata-rata yaftu 13,3%. "
Depok: Fakultas Teknik Universitas Indonesia, 1999
S37016
UI - Skripsi Membership  Universitas Indonesia Library
cover
Cheremisinoff, Nicholas P.
Ann Arbor, Mich.: Ann Arbor Science, 1981
621.197 CHE c
Buku Teks  Universitas Indonesia Library
cover
Fadhil Azharrisman
"Penelitian ini membahas mengenai perancangan dan perhitungan palka ikan untuk kapal ikan 30 GT menggunakan kapal yang dirancang khusus. Pada penelitian ini pendinginan palka ikan menggunakan sistem refrigerasi untuk mengoptimalkan volume ruangan palka karena, dalam pengoperasiannya palka berpendingin es membutuhkan 50% dari kapasitas ruang palka untuk memuat es. Dalam penelitian ini, dilakukan studi literatur guna menentukkan parameter perhitungan, desain geometrik palka, dan dilakukan simulasi CFD menggunakan Ansys Fluent untuk menilai bentuk aliran fluida pendingin dan waktu pendinginan produk, lalu dilanjutkan dengan perhitungan beban pendinginan dan kebutuhan daya listrik yang dibutuhkan untuk sistem pendingin yang telah dirancang. Berdasarkan hasil simulasi didapatkan waktu pendinginan paling cepat terjadi ketika kecepatan inlet fluida pendingin 8 m/s pada kapasitas pemuatan 100% dengan waktu pendinginan ikan dari 27°C sampai 0°C membutuhkan waktu selama 4 jam 15 menit, serta kebutuhan daya total untuk sisterm refrigerasi yaitu 5,88 kW.

This study discusses the design and calculation of fish hold for 30 GT fishing vessels using specially designed vessels. In this study, fish hold cooling uses a refrigeration system to optimize the volume of the hold because, in its operation, the ice-cooled hatch requires 50% of the capacity of the hold to load ice. In this study, a literature study was conducted to determine the calculation parameters, geometric design of the hold, and a CFD simulation was carried out using Ansys Fluent to review the shape of the cooling fluid flow and product cooling time then continued with the calculation of the cooling load and the electrical power required for the cooling system has been designed. Based on the simulation results, the fastest cooling time occurs when the cooling fluid inlet velocity is 8 m/s at a loading capacity of 100% with a cooling time of fish from 27°C to 0°C which takes 4 hours 15 minutes, as well as the total power requirement for the refrigeration system is 5.88 kW."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>