Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 12696 dokumen yang sesuai dengan query
cover
Anderson, Bruce N.
New York: McGraw-Hill, 1977
697.78 AND s (1)
Buku Teks SO  Universitas Indonesia Library
cover
Anderson, Bruce N.
New York: McGraw-Hill, 1977
621.47 AND s (1)
Buku Teks  Universitas Indonesia Library
cover
Yannas, Simos
London: Architectural Association, 1993
720.472 YAN s
Buku Teks SO  Universitas Indonesia Library
cover
Gevorkian, Peter
New York: McGraw-Hill, 2008
720.472 GEV s
Buku Teks SO  Universitas Indonesia Library
cover
cover
Tully, Gordon F.
New York, NY: McGraw-Hill, 1981
697.78 TUL s
Buku Teks SO  Universitas Indonesia Library
cover
Sutanto, 1950-
"Research has been carried out for designing and construction of solar radiation concentration by using array of mirrors. A solar water heater is used to demonstrate the usefulness of such solar radiation concentration."
Depok: Fakultas Teknik Universitas Indonesia, 1993
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Schubert, Richard C.
Englewood Cliffs, NJ: Prentice-Hall, 1981
697.78 SCH f
Buku Teks SO  Universitas Indonesia Library
cover
Adi Januardi
"Penggunaan energi terbarukan sebagai sumber pembangkitan energi listrik terus mengalami peningkatan setiap tahunnya. Namun, di Indonesia sendiri belum banyak pembangkit listrik yang memanfaatkan energi terbarukan ini sebagai sumbernya. Padahal kita ketahui bahwa Indonesia memiliki potensi energy terbarukan yang sangat besar. Salah satu potensi energi terbarukan yang sangat besar di Indonesia adalah cahaya matahari. Dengan photovoltaics sebagai alat yang menyerap dan mengubah energi matahari menjadi energi listrik maka energi listrik yang dihasilkan dari sumber energi matahari tersebut diperkirakan sangat besar hasilnya. Namun, modul photovoltaics ini sangatlah rentan terhadap kondisi lingkungan sekitarnya sehingga dapat memengaruhi energi listrik yang dihasilkan. Maka dari itu, diperlukannya perhitungan performa modul PV untuk memprediksikan besar energi yang akan dihasilkan suatu modul PV pada kondisi lingkungan tertentu sehingga kita dapat menentukan tipe modul PV yang akan digunakan.
Pada skripsi ini digunakan dua metode perhitungan performa PV, yaitu Sandia PV Array Performance Model dan Five Parameters Model, dimana kedua metode ini akan dibandingkan satu sama lain. Sehingga didapat bahwa metode Five Parameters merupakan metode perhitungan performa PV yang paling optimal dan efisien yang dapat digunakan pada daerah tropis karena hanya membutuhkan input data yang sedikit namun memberikan hasil prediksi keluaran energy listrik yang cukup presisi, yaitu 56,58 Wdc untuk mono-crystalline PV, 52,7 Wdc untuk poly-crystalline PV, dan 43,29 Wdc untuk thin film PV, dengan input data yang sedikit. Metode five parameters juga dapat menghasilkan kurva karakteristik (I-V) pada kondisi operasi modul PV yang lebih presisi.

The use of renewable energy as a source of electric energy generation continues to increase every year. However, in Indonesia itself has not many power plants that utilize renewable energy source. And we all know that Indonesia has the potential of renewable energy is very large. One of the renewable energy potential that very large in Indonesia is sunlight. With photovoltaics as a tool that absorb and convert solar energy into electrical energy, the electrical energy generated from solar energy sources are expected very big results. However, photovoltaics module is particularly vulnerable to environmental conditions that can affect the electrical energy produced. Therefore, the need for PV module performance calculations to predict the amount of energy that will be produced by a PV module in a certain environment so that we can determine the type of PV modules that will be used.
In this study used two methods of calculating the performance of PV, those are Sandia PV Array Performance Model and Five Parameters Model, where both methods will be compared with each other. In order to get that Five Parameters method is the most optimal and efficient method in calculating PV performance that can be used in tropical region as it only requires less input data but may predicted electrical energy output with sufficient precision, those are 56,58 Wdc for mono-crystalline PV, 52,7 Wdc for poly-crystalline PV, and 43,29 Wdc for thin film PV, with less data input. Five parameters method can also produce the characteristic curve (I-V) on a PV module operating conditions more precise.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S65496
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dhavani Ardyas Putera
"Energi terbarukan yang berasal dari radiasi matahari merupakan salah satu sumber energi potensial di Indonesia karena letak geografisnya. Hal ini dapat mendukung pemenuhan kebutuhan energi yang terus meningkat, khususnya di wilayah Provinsi Jawa Barat yang memiliki kepadatan penduduk tertinggi di Indonesia. Namun, radiasi matahari bersifat intermiten karena dipengaruhi oleh kondisi atmosfer yang dinamis, sehingga diperlukan estimasi nilai radiasi matahari yang mencapai permukaan bumi. Penelitian ini melakukan estimasi radiasi matahari menggunakan model Gated Recurrent Unit (GRU) pada dua lokasi, yaitu Puslitbang PLN dan BMKG Sumedang, berdasarkan skema parameter terbaik. Analisis spasial dilakukan menggunakan model Weather Research and Forecasting (WRF), serta pengujian hybrid model dilakukan untuk meningkatkan akurasi model GRU. Hasil model menunjukkan nilai relative root mean square error (rRMSE) yang tinggi untuk Puslitbang PLN (50,21%) dan BMKG Sumedang (46,19%). Berdasarkan pola sebaran radiasi matahari terhadap tutupan lahan, nilai radiasi tinggi tersebar di wilayah terbangun dan rendah pada wilayah vegetasi. Selanjutnya, integrasi data dari model WRF dilakukan untuk meningkatkan akurasi estimasi radiasi matahari. Namun, peningkatan akurasi ini hanya terjadi pada lokasi BMKG Sumedang dengan nilai rRMSE 45,05%, sementara di Puslitbang PLN tidak terdapat peningkatan yang signifikan karena kualitas data temporal yang kurang baik. Oleh karena itu, pengembangan metode serta ketersediaan data temporal berkualitas baik menjadi hal yang penting untuk menghasilkan model dengan akurasi tinggi.

Renewable energy from solar radiation is a potential energy source in Indonesia due to its geographical location. This can support the growing energy needs, especially in West Java Province, which has the highest population density in Indonesia. However, solar radiation is intermittent due to dynamic atmospheric conditions, necessitating the estimation of solar radiation reaching the Earth's surface. This study estimates solar radiation using the Gated Recurrent Unit (GRU) model at two locations: Puslitbang PLN and BMKG Sumedang, based on the best parameter scheme. Spatial analysis was conducted using the Weather Research and Forecasting (WRF) model, and hybrid model testing was carried out to improve the accuracy of the GRU model. The model results showed relatively high relative root mean square error (rRMSE) values for Puslitbang PLN (50.21%) and BMKG Sumedang (46.19%). Based on the distribution patterns of solar radiation against land cover, high radiation values were found in built-up areas and low values in vegetated areas. Furthermore, data integration from the WRF model was performed to enhance the accuracy of solar radiation estimation. However, this accuracy improvement was only observed at the BMKG Sumedang location, with an rRMSE value of 45.05%, while no significant improvement was noted at Puslitbang PLN due to poor temporal data quality. Therefore, the development of methods and the availability of high-quality temporal data are crucial to achieve high model accuracy."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>