Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 9939 dokumen yang sesuai dengan query
cover
Robert, Christian P.
New York: Springer, 1999
519.5 ROB m
Buku Teks  Universitas Indonesia Library
cover
Kroese, Dirk P.
"The purpose of this handbook is to provide an accessible and comprehensive compendium of Monte Carlo techniques and related topics. It contains a mix of theory (summarized), algorithms (pseudo and actual), and applications. Since the audience is broad, the theory is kept to a minimum, this without sacrificing rigor. The book is intended to be used as an essential guide to Monte Carlo methods to quickly look up ideas, procedures, formulas, pictures, etc., rather than purely a monograph for researchers or a textbook for students. As the popularity of these methods continues to grow, and new methods are developed in rapid succession, the staggering number of related techniques, ideas, concepts and algorithms makes it difficult to maintain an overall picture of the Monte Carlo approach. This book attempts to encapsulate the emerging dynamics of this field of study."
New Jersey: Wiley , 2011
518.282 KRO h
Buku Teks  Universitas Indonesia Library
cover
M. Taufiq Ma`ruf
"Mempertimbangkan kompleksitas permasalahan proyek, metode simulasi merupakan suatu pendekatan analisa risiko yang memadahi. Metode simulasi adalah teknik analisa yang berupaya rnenirukan perilaku sistem yang dikaji. Metode simulasi memungkinan menganalisa proyek dari dua sudut padang utama proyek yaitu cost dan durasi secara rinci dan mendekali nyata. Oleh karena itu penulis mencoba menganalisa risiko-risiko yang akan muncul dalam Proyek VAC RS. Brawijaya sehingga dapat dicarikan jalan keluarnya. Dalam skripsi ini dibahas bagaimana mengidentifikasi risiko dengan Failure Mode Effect Anaysis dan melakukan pembobotan dengan RPN yang berisi Severity, Occurance dan Detection. Setelah melakukan identifikasi dan pembobotan proses analisa risiko selanjutnya mengunakan bantuan software @_Risk for Project untuk melakukan simulasi. Setelah model diverifikasi dan divalidasi, maka model dirurming untuk rnendapatkan data sebagai bahan untuk melakukan analisa risiko cost dan durasi, sehingga dapat diketahui baseline cos: dan base durasi untuk proyek tersebut. Dari hasil analisa tersebut diketahui bahwa dengan cost proyek RS. Brawijaya 1.8 milyar maka memiliki tingkat risiko sebesar 51.79% dan risiko proyek mengalami kemunduran sekitar 27%.

Considering complexity problems of project, simulation method is an approach of risk analysis. Simulation method is analysis technique coping to imitate behavior of studied system. Simulation method possible to analyze the project from two point of view ; namely cost and duration of the project. Therefore this research try to analyze risks that emerge in VAC Project at RS. Brawijaya so that can be looked for way out. In this research is studied how to identify risk with Failure Mode of Effect Analysis and conduct weighting used RPN which is containing Severity, occurrence and Detection. After steps identify and process weight analyze risk than use soiiware @Risk for Project to do simulation. After verification model and validation, hence model is rurming to get data upon which to analyze risk of cost and duration, so that can be known cost and duration baseline project. From the analysis result known that cost of project RS. Brawijaya 1.8 billion hence owning risk storey ;level equal to 51.79% and risk of project duration lagging down 27%."
Depok: Fakultas Teknik Universitas Indonesia, 2006
S50327
UI - Skripsi Membership  Universitas Indonesia Library
cover
Winkler, Gerhard
Berlin: Springer-Verlag, 1995
621.367 WIN i
Buku Teks  Universitas Indonesia Library
cover
Agostino Di Ciaccio, editor
"The book includes 45 papers from a selection of the 156 papers accepted for presentation and discussed at the conference on “Advanced statistical methods for the analysis of large data-sets.”"
Berlin: [, Springer-Verlag ], 2012
e20418930
eBooks  Universitas Indonesia Library
cover
Harjono
"ABSTRAK
Perlakuan radioterapi pada daerah paru memerlukan perhatian khusus karena
dalam daerah tersebut terdapat berbagai jaringan dengan densitas massa maupun
densitas elektron bervariasi, oleh karena itu setiap komponen mempunyai daya
serap yang berbeda. Hasil pengobatan radioterapi dipengaruhi oleh ketepatan
sistem perencanaan pengobatan (TPS) dalam menentukan distribusi dosis dalam
pasien. Tujuan dari tesis ini adalah untuk mengetahui distribusi dosis (kurva
isodosis dan PDD) dalam paru pada simulasi Monte Carlo perlakuan radioterapi
kanker paru menggunakan sinar-x Megavolt. Penelitian ini menggunakan simulasi
Monte Carlo program paket EGSnrc yang terdiri dari BEAMnrc, dan
DOSXYZnrc. Distribusi dosis yang dihasilkan dari simulasi Monte Carlo
kemudian dibandingkan dengan data TPS. Dalam simulasi ini, energi awal
elektron yang optimum adalah 6,2 MeV untuk mengsimulasikan sinar-x 6 MV.
Simulasi Monte Carlo pada citra CT pasien kanker paru sebelah kanan dengan
kedalaman target 7.5 cm menghasilkan nilai PDD 84,4 % untuk lapangan 5 x 5
cm2 dan 80,3 % untuk lapangan 10 x 10 cm2. Untuk pasien yang sama kalkulasi
TPS menghasilkan nilai PDD pada target 75,2 % untuk lapangan 5 x 5 cm2 dan
74,8 % untuk lapangan 10 x 10 cm2. Faktor koreksi untuk luas lapangan 5 x 5 cm2
adalah 1,0 ? 1,087. Sedangkan pada luas lapangan 10 x 10 cm2 diperoleh faktor
koreksi 1,0 -1,066.

Abstract
Radiotherapy treatment in lung regions require special concern because in the area
there are different tissues of the mass density and electron density varies, so each
component has a different absorption. The results of radiotherapy are influenced
by the accuracy treatment planning system (TPS) in determining treatment dose
distribution in patient. The purpose of this thesis is to know dose distribution
(isodos curve and PDD) of the lung at the simulation Monte Carlo treatment the
lung cancer radiotherapy using x-ray Megavolt. This research using simulation
Monte Carlo, packet program EGSnrc that consist of BEAMnrc and DOSXYZnrc.
Dose distribution which is resulted from simulation Monte Carlo then compare
with TPS data. In this simulation, first energy of electron optimum is 6.2 MeV to
simulate x-ray 6 MV. Result PDD value on simulation Monte carlo with CT
images patients right lung cancer with a target depth of 7.5 cm is 84.4% for a field
of 5 x 5 cm2 and 80.3% for the 10 x 10 cm2. For the same patient TPS calculation
result PDD at the target value 75.2 % for field 5 x 5 cm2 and 74.8 % for the 10 x
10 cm2. Correction factor for field wide 5 x 5cm2 is 1.0 ? 1.087. Mean while at the
field wide 10 x 10cm2 is resulted correction factor 1.0 - 1.066."
2012
T31777
UI - Tesis Open  Universitas Indonesia Library
cover
Abdi Wadud Syafi`i
"Telah dilakukan studi simulasi Monte Carlo untuk perhitungan besaran dosimetri dari berkas sinar X 6 MeV tanpa filter perata yang dihasilkan Linac Elekta SL-15. Pemodelan kepala Linac menggunakan program BEAMnrc, analisis phase space file menggunakan program BEAMDP dan perhitungan dosis radiasi dalam medium air menggunakan program DOSXYZnrc. Parameter awal elektron dalam simulasi ini menggunakan hasil yang sudah diperoleh oleh saudara Anam C. Perhitungan PDD dalam medium air dilakukan dengan variasi ukuran lapangan 5x5, 10x10, 20x20 dan 40x40 cm2 dengan SSD 100 cm. Dosis profil dihitung dengan variasi ukuran lapangan yang sama dengan kedalaman 10 cm.
Hasil perhitungan PDD tanpa filter relatif lebih rendah dibanding dengan PDD dengan filter dan tidak dipengaruhi ukuran lapangan radiasi. Spektrum berkas sinar-X tanpa filter perata mempunyai fraksi komponen energi rendah relatif lebih tinggi dibanding dengan sinar-X dengan filter perata sehingga kurva PDD-nya relatif lebih rendah. Hasil perhitungan dosis profil menunjukan dengan melepaskan filter perata akan meningkatkan fluence dan energi fluence serta laju dosis untuk setiap lapangan radiasi.
Hasil penting lainnya adalah dosis permukaan yang jauh lebih tinggi dibanding dengan sinar X yang ber-filter mencapai 59.42 % untuk lapangan 5x5 cm2 dan 70.13 % untuk lapangan 40x40 cm2 dan dosis yg tinggi pada daerah build-up diakibatkan kontaminasi elektron. Berdasarkan hasil yang didapat penggunaan sinar X tanpa perata akan menurunkan skin sparring effect, sehingga tidak cocok untuk dipakai pada Linac. Namun, masih mungkin digunakan untuk teknik IMRT yang membutuhkan intensitas output yang tinggi.

Study on dosimetric properties for an unflattened 6-MV photon beams of an Elekta SL15 linac was calculated using Monte Carlo simulation has been done. The linear accelerator head was simulated by BEAMnrc code and the phase-space file then was analyzed by BEAMDP, while the absorbed dose in water phantom was calculated using DOSXYZnrc code. Initial parameters of electrons in this simulation using the results already obtained by Anam C. PDD calculations performed in water medium by variation of field size 5x5, 10x10, 20x20 and 40x40 cm2 with SSD 100 cm. Dose profiles calculated with the same field size variation with depth of 10 cm.
PDD calculation results without the filter is relatively lower compared with the PDD with the filter and not influenced by the size of the radiation field. The spectrum of unflattened X-ray beam has a fraction of the low energy component is higher than with flattened X-rays so that the PDD curve is relatively lower. The results of dose calculation shows the release flattening filter will increase the fluence and energy fluence and dose rate for each radiation field.
Another important outcome is that the surface dose is much higher than with flattened X-ray to the field reaches 59.42% and 70.13% of 5x5 cm2 to 40x40 cm2 field and on high doses in the build-up due to contamination of electrons. Based on the results obtained using unflattened X-rays the skin sparring effect will decrease, making it unsuitable for use in the linac. However, it still may be used for IMRT techniques that require high output intensity.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2011
T29797
UI - Tesis Open  Universitas Indonesia Library
cover
Bajpai, A.C.
Chichester: John Wiley & Sons, 1982
519.5 BAJ s
Buku Teks  Universitas Indonesia Library
cover
Snedecor, George W.
Ames, Iowa: Iowa State University Press, 1989
519.5 SNE s
Buku Teks  Universitas Indonesia Library
cover
Snedecor, George W.
Ames, Iowa: The Iowa State University Press, 1980
519.5 SNE s
Buku Teks  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>