Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 177428 dokumen yang sesuai dengan query
cover
cover
Djoko Irwanto
Universitas Indonesia, 1996
S31988
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mulhaquddin Sastrayuninrat
"ABSTRAK
Telah dipelajari degradasi fotokatalisis etanol, benzena dan kloroform dalam fasa air menggunakan lapisan tipis TiO2. Percobaan dilakukan menggunakan reaktor alir kontinyu dengan TiO2 yang diimobilisasikan pada dinding dalam kolom gelas dan lampu UV black light digunakan sebagai sumber radiasi. Uji aktifitas reaktor terhadap larutan model pada reaktor dengan sistem tanpa pendingin dan memakai pendingin dilakukan untuk mengetahui pengaruh evaporasi pada pengolahan larutan model. Untuk evaluasi proses yang diuji dilakukan pengukuran pH larutan, daya hantar listrik dan ion klorida dan analisis senyawa intermediat dengan GC dan GC-MS.
Hasil percobaan degradasi fotokatalisis etanol, benzena dan kloroform dalam fasa air menunjukkan terjadinya penurunan pH, naiknya daya hantar listrik dan naiknya konsentrasi ion klorida untuk model kloroform selama proses berlangsung. Senyawa intermediet hasil degradasi secara fotokatalisis dari etanol yang dapat diamati adalah asetaldehida. Penerapan sistem pengolahan yang dikembangkan ini, pada contoh sisa bilasan pelarut organik, menunjukkan kemampuannya menurunkan nilai COD sebesar 83.95 %.

ABSTRACT
Photocatalytic degradation of aquoeus etanol, benzene and chloroform was studied by using TiO2 film catalyst. The experiment was performed in a continous flow reactor, in which TiO2 was immobilized on the inner wall of glass tubes and UV black light lamps were used as radiation source. Test of reactor activity without condensor and with condensor was conducted to know influence of evaporation model. For evaluation process was done by measurement pH, conductivity and chloride ion, and analyses intermediat compound with GC and of GC-MS.
Result of Photocatalytic degradation aquoeus etanol, benzene and chloroform is shown decreasing of pH, increasing conductivity and increasing of chloride ion concentration for chloroform model during process. Result of intermediet compound for photocatalytic degradation of aquoeus etanol is asetaldehide. The experiment on laboratory waste water is indicated to ability decreasing of COD(chemical oxygen demand) about 83.95 %.
"
2007
T40102
UI - Tesis Membership  Universitas Indonesia Library
cover
Armon Fernando
"Penelitian ini melakukan optimasi metode analisis penetapan kadar sisplatin secara kromatografi cair kinerja tinggi melalui derivatisasi menggunakan pereaksi dietilditiokarbamat untuk meningkatkan selektivitas dan sensitifitasnya terhadap detektor Uv-Vis, karena senyawa sisplatin tidak mempunyai gugus kromofor yang dapat terdeteksi oleh detektor ultraviolet. Menentukan kadar ondansetron hidroklorida dalam sampel dicobakan mengoptimasi penggunaan kolom fase terbalik C18 yang belum umum untuk penetapan kadar ondansetron. Sisplatin mempunyai efek samping emetogenik kuat yang dapat di hambat oleh ondansetron melalui inhibitor reseptor 5-HT3 yang sangat efektif untuk pencegahan mual dan muntah selama kemoterapi sisplatin yang diberikan secara terpisah melalui intravena. Pemberian antiemetik bersamaan dengan kemoterapi dalam satu rute pemberian diharapkan lebih efektif dan efisien untuk penanganan kemoterapi kanker. Pemberian dalam satu rute secara bersamaan harus dilakukan evaluasi stabilitas kimia campuran sisplatin dan ondansetron hidroklorida dalam satu larutan infus NaCl 0,9 % selama 24 jam kemoterapi kanker.
Sisplatin dianalisis menggunakan kromatografi cair kinerja tinggi melalui derivatisasi dengan pereaksi natrium dietilditiokarbamat 10% dalam NaOH 0,2N. Derivat sisplatin-dietilditiokarbamat dielusi menggunakan fase gerak asetonitrilair (70:30 %v/v) dengan kecepatan alir 0,8 ml/menit pada kolom Knauer® C18-RP (250 x 4,6 mm, 5µm). Ondansetron hidroklorida dianalisis dan dipisahkan menggunakan kolom Sunfire Waters® C18-RP (25 cm x 4,6 mm, 5 µm) dengan fase gerak KH2PO4 50 mM (pH 7) dan asetonitril (75:25 %v/v) dengan kecepatan alir 2 ml/menit dan dideteksi pada panjang gelombang 249 nm. Stabilitas kimia kedua obat selama 24 jam dievaluasi dengan membuat campuran larutan injeksi sisplatin 92,42 ppm dan ondansetron HCl 59,15 ppm dalam larutan infus NaCl 0,9 % yang disimpan pada suhu 27°C dibawah cahaya ruangan normal.
Hasil derivatisasi sisplatin dengan 20µl dietilditiokarbamat 10% pada suhu 90°C selama 20 menit diekstraksi dengan 2ml kloroform dan dideteksi pada panjang gelombang 344 nm. Metode linier pada kisaran 20 sampai 140 ppm dengan batas deteksi (LOD) 3,606 ppm dan koefisien variasi intra-hari dan interhari rata-rata < 2 % pada semua tingkat konsentrasi. Optimasi metode analisis ondansetron hidroklorida diperoleh kurva kalibrasi yang linier pada kisaran 5 sampai 100 ppm dengan batas deteksi (LOD) 3,404 ppm serta presisi intra-hari dan inter-hari dengan koefisien variasi rata-rata ≤ 2 % pada semua tingkatan konsentrasi pengujian. Hasil stabilitas kimia campuran kombinasi sisplatin dan ondansetron HCl dalam larutan infus NaCl 0,9%, diketahui sisplatin dan ondansetron HCl stabil selama 4 jam meskipun berkurangnya potensi <10% dari kedua komponen obat. Metode yang dikembangkan selektif dan spesifik untuk pemisahan dan kuantitasi penetapan sisplatin dan ondansetron HCl dari hasil uraiannya dalam satu campuran sediaan farmasi.

This research to the optimization analysis methods of the determination of the cisplatin consentrations utilizing high performance liquid chromatography to establishment concentration of cisplatin utilizing reagents diethyldithiocarbamate to increasing it selectifity and sensitifity for ultraviolet detection, because the cisplatin compounds does not have any chromophore fungtions that can be detected by ultraviolet detector. Determine the consentration ondansetron hydrochloride in the sample we purpose optimize the use of C18 reversed phase column is not common for the determination of ondansetron consentrations. Cisplatin have any side effects strong emetogenic that it can be blocked by ondansetron via inhibitor 5-HT3 receptors which is very effective for the prevention of nausea and vomiting during cisplatin chemotherapy provided separately through intravenously. Giving antiemetic along with chemotherapy in an expected route of more effective and efficient handling of chemotherapy for cancer. Giving in a route at the same time stability evaluation should be conducted chemical mixture cisplatin and ondansetron hydrochloride in one solution infuse NaCl 0.9% during the 24 hours of cancer chemotherapy.
Cisplatin was analyzed using high performance liquid chromatography through derivatisation with sodium diethyldithiocarbamate reagents in 10% NaOH 0.2 N. Derivate cisplatin-diethyldithiocarbamate was eluted using phase mobile acetonitrile-water (70:30% v/v) with the flow rate 0.8 ml / min on the Knauer ® C18-RP (250 x 4.6 mm, 5μm) column. Ondansetron hydrochloride was analyzed and separated using a Sunfire Waters ® C18-RP (25 cm x 4.6 mm, 5 μm) column with a mobile phase 50 mM KH2PO4 (pH 7) and acetonitrile (75:25% v/v) with the flow rate 2 ml / min and detected at 249 nm. Chemical stability of both drugs for 24 hours was evaluated by creating a mixture solvent injection cisplatin 92.42 ppm and 59.15 ppm ondansetron HCl solution in 0.9% NaCl infuse was stored at a temperature of 27°C under normal room light.
Derivatisation results of cisplatin with 20μl diethyldithiocarbamate 10% at a temperature of 90°C for 20 minutes with 2ml chloroform extracted and detected at 344 nm. Methods was linier over the range 20 to 140 ppm with a limit of detection (LOD) 3.606 ppm and the coefficient of variation intra-day and interday average of <2% for all concentration. The ondansetron hydrochloride methods was optimized and validated with the calibration curve was linier over the range of 5 to 100 ppm with a limit of detection (LOD) 3.404 ppm. Precision intra-day and inter-day coefficients of variation average ≤ 2% for all concentration. Chemical stability results of mixture combination of cisplatin and ondansetron HCl in 0.9% NaCl infuse solution, known the cisplatin and ondansetron HCl was stable for 4 hours although loss of their potencies <10%. Methods was developed for specific and selective separation and quantitation determination of cisplatin and ondansetron HCl from its decomposition in the mixture of pharmaceutical dosage form.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2009
T29848
UI - Tesis Open  Universitas Indonesia Library
cover
cover
cover
cover
Iwan Setiawan
"Kebutuhan asam dari suatu pelarutan bijih tembaga teroksidasi merupakan salah satu faktor penting secara ekonomi dan kuantitasnya harus dapat ditentukan secara optimal untuk mendapatkan proses pelarutan yang efisien. Suatu studi kinetik oleh asam sulfat dari bijih tembaga teroksidasi khususnya Malachite telah diteliti. Pengaruh dari waktu leaching, kecepatan pengadukan, konsentrasi asam dan perbandingan solid liquid, temperature dan ukuran dari bijih telah diteliti. Menggunakan kondisi terbaik diperoleh recovery 90% pada 250C dan 98% pada 800C setelah 150 menit waktu leaching dan pada konsentarsi asam 1 mol/L dengan perbandingan liquid/solid 6:1. Pelarutan dari Malachite selama leaching dapat digambarkan sebagai fungsi logaritma, y=a ln(x) + B. Berdasarkan data dari pelarutan awal menggunakan asam sulfat diketahui bahwa kinetika pelarutan batuan tembaga jenis malachite dikontrol oleh suatu reaksi diffusi.

The relationship of percent copper extraction to acid consumption must be refined to optimized the economic value and the consumption quantity must be known to get the efficiency of extraction. A study kinetics of the sulfuric acid leaching of oxidized copper ore malachite from North Sumatera was carried out. The effect of leaching time, stirring, sulfuric acid concentration, ratio solid liquid, temperature, particle size were analyzed. The optimum condition, copper recovery about 90% at 250C and 98% at 800C after 30 minute leaching time in 1.0 M sulfuric acid concentration with liquid/solid ratio 6:1 at 150 rpm. Malachite dissolution during leaching can be described by logaritmic function. Basic on data obtained for the leaching kinetics indicated that the initial dissolution of malachite is a diffusion controlled reaction."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
T21341
UI - Tesis Membership  Universitas Indonesia Library
cover
Sigit Yulianto
Depok: Fakultas Teknik Universitas Indonesia, 1993
S39586
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rini Riastuti
"ABSTRAK
Pada proses elektrorefining Cu, anoda yang tidak murni dilarutkan secara elektrokimia dan diendapkan kembali sebagai produk yang lebih murni di katoda. Salahsatu cara yang dapat dilakukan untuk meningkatkan kemurnian produk khususnya dari pengotor Ag adalah dengan menambahkan MCL pada elektrolit yang digunakan. Dari penelitian diperoleh hasil bahwa penambahan MCL tidak dapat dilakukan secara bebas penambahan HCL dalam jumlah 3 dan 6 gpl menyebabkan potensial sel naik tajam dan anoda menjadi tertutup oleh endapan putih tembaga khlorida sehingga elektorefining secara umum menurun."
Depok: Fakultas Teknik Universitas Indonesia, 1994
LP-Pdf
UI - Laporan Penelitian  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>