Evdokimov, F.
Moscow: MIR Publisher, 1977
621.302 EVD f (1);621.302 EVD f (2)
Buku Teks SO  Universitas Indonesia Library
cover
Galih Ilham Mey Setiawan
"Pada saat pengoperasian transformator, permasalahan yang umum terjadi adalah timbulnya kegagalan, baik kegagalan termal maupun kegagalan elektris. Isolasi minyak memiliki peranan yang penting terhadap kinerja suatu transformator. Oleh karena itu, diperlukan suatu pengontrolan terhadap kondisi minyak transformator agar keandalannya tetap terjaga. Pengontrolan kondisi tersebut dapat dilakukan dengan melakukan pengujian minyak transformator berdasarkan uji parameter utama, yaitu pengujian Dissolved Gas Analysis (DGA), pengujian kandungan air (water content) dan pengujian tegangan tembus (breakdown voltage).
Dari keenam sampel minyak yang diujikan, indikasi awal yang terjadi adalah fenomena kegagalan dengan tingkat energi yang rendah, seperti korona, overheated cellulose dan permasalahan yang melibatkan logam panas. Selain itu, dengan menggunakan metode koefisien korelasi dapat disimpulkan bahwa parameter pengujian DGA merupakan parameter uji yang berdiri sendiri atau tidak berkaitan dengan parameter uji lain. Sementara pengujian tegangan tembus dan kandungan air memiliki korelasi yang tinggi yaitu berbanding terbalik, sehingga hasil dari pengujian salah satu parameter, dapat diprediksi apabila nilai dari hasil pengujian parameter lainnya telah diketahui.
Hal ini terlihat dari hasil pengujian bahwa sampel minyak ke-4 memiliki kandungan air tertinggi yaitu 14,525 ppm dan tegangan tembus terendah sebesar 43,2 kV. Sebaliknya, sampel minyak ke-6 memiliki kandungan air terendah, yaitu 6,332 ppm dan tegangan tembus tertinggi sebesar 71,9 k.

At the time operation of the transformer, a common problem that occur is the onset of failure, both thermal and electrical failure. Insulating oil has an important role on the performance of a transformer. Therefore, a control on the condition is needed in order to maintain its reliability. The control condition can be done by testing transformer oil based on the main parameters test, such as Dissolved Gas Analysis (DGA) test, water content test and breakdown voltage test.
From the six oil samples that tested, initial indications are failure phenomenon that occurs with low energy levels, such as corona, overheated cellulose and issues involving hot metal. Moreover, by using the correlation coefficient method can be concluded that DGA is a stand-alone test parameters or not related to the other test parameters. While the breakdown voltage and water content test have a high correlation, which is inversely proportional, so that the result of testing one of the parameters, can be predicted if the value of the other parameters of the test result are known.
This can be seen from the test results that the 4th oil samples has the highest water content with the value 14,525 ppm and also the lowest breakdown voltage of 43,2 kV. In contrast, the 6th oil sample has the lowest water content, i.e 6,332 ppm and the highest breakdown voltage of 71,9 kV.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S52581
UI - Skripsi Membership  Universitas Indonesia Library
cover
Auto Hartanto
"Electric Submersible Pump ESP sebagai salah satu metode pengangkatan buatan artificial lift minyak bumi yang dianggap paling efektif dan efisien, semakin banyak diterapkan oleh industri minyak dan gas. Begitupula dengan PT. Medco E P Indonesia yang sedang melakukan perubahan metode artificial lift gas lift menjadi ESP untuk Blok Rimau, Kaji, Sumatera. Dalam proses kerjanya ESP membutuhkan Variable Speed Drive VSD untuk mengendalikan putaran motor submersible sehingga dapat mengatur debit fluida yang dapat diangkat. Namun, saat populasi ESP semakin bertambah, tentunya jumlah dari VSD, sebagai sumber harmonisa beban non-linier , akan semakin bertambah pula. Sehingga kadar harmonisa pada sistem ketenagalistrikan akan semakin mengingkat.
Berdasarkan penelitian dalam skripsi ini, penerapan dari transformator penggeser fasa ini mampu menurunkan kadar harmonisa di Kaji, khususnya arus harmonisa orde ke-5 mencapai 61,97, orde ke-7 mencapai 75,67 , orde ke-17 mencapai 90,90, orde ke-19 mencapai 57,14, dan total harmonisa arus mencapai 58 pada titik hubung listrik PCC. Oleh karena itu, transformator penggeser fasa menjadi pilihan metode untuk mengendalikan harmonisa agar dampaknya tidak mengganggu sistem sehingga menurunkan hasil produksi minyak.

ESP is a one of artificial lift as a considered to be a most effective and efficient methods. The same with PT. Medco E P Indonesia which is doing transformation artificial methods from gas lift to ESP in Rimau Block, Kaji, Sumatera. In the operation system, ESP needs VSD to adjust the speed of induction motors so that can be used to control the flowrate of fluid lifted by the ESP. However, when the population of ESP is increasing, certainly quantity of VSD, as a nonlinear load, is increasing too. Futhermore level of harmonics in electric power system more increasing.
Based on a research in this thesis, implementation of phase shifting transformers can be decreased level of harmonics in Kaji, especially for harmonic current level order 5 up to 61,97, order 7 up to 75,67, order 17 up to 90,90, order 19 up to 57,14, and total harmonic distortion current up to 58 in the point of common coupling PCC. Therefore, phase shifting transformers as a choice methods for handling harmonics so that doesn't make descrease production of oil.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S66222
UI - Skripsi Membership  Universitas Indonesia Library
cover
Femy Sanana Sanvia
"Perubahan bentuk jaringan distribusi radial menjadi bentuk jaringan spindle pada GI Ciawi Bogor bertujuan untuk meningkatkan keandalan sistem tenaga listrik dengan adanya penyulang express yang dapat berfungsi sebagai suplai cadangan. Untuk menunjang sistem yang handal maka diperlukan adanya sistem proteksi yang baik. Pada sistem proteksi jaringan distribusi spindle digunakan rele arus lebih sebagai pengaman dari gangguan hubung singkat. Tahapan awal dalam menentukan setting rele arus lebih adalah dengan melakukan studi aliran daya untuk menentukan arus beban maksimum (nominal) yang melalui rele. Selanjutnya dilakukan perhitungan arus gangguan hubung singkat untuk menentukan setting arus pada rele.
Skripsi ini akan membahas mengenai koordinasi proteksi rele arus lebih pada perencanaan jaringan distribusi spindle GI Ciawi Trafo 1 Bogor. Berdasarkan hasil simulasi didapatkan bahwa koordinasi antar rele telah bekerja sesuai urutan dengan waktu kerja antar rele berkisar 0,1-0,2 detik.

Changes in the radial distribution network form into the spindle network form at GI Ciawi Bogor aims to increase the reliability of power system with the express feeder which could serve as backup supply. To support the reliability of power system then it is necessary to have a good protection system. The protection system of spindle distribution network uses the overcurrent relay to protect from nuisance overcurrent. The first step of determining overcurrent relay setting is perform power flow studies to determine the maximum load current (nominal) passing through the relay. Further step is perform the short circuit fault current calculations to determine the current setting of the relay.
This thesis will discuss about coordination of overcurrent relay in the planning of spindle distribution network in GI Ciawi Transformers 1 Bogor. The result of simulations is the coordination between the relay has been working sequentially with the work time of relay range is 0,1-0,2 seconds.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S52579
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Yanuar Hidayat
"Skripsi ini membahas tentang pengaruh suhu terhadap degradasi isolasi dan perkiraan nilai harapan hidupisolasi padat dan cair transformator. Hasil pengujian menunjukkan bahwa temperatur berbanding terbalik dengan tegangan tembus dan temperatur akan memperkecil nilai harapan hidup isolasi.Tegangan tembus isolasi paling rendah secara berurutan dari variasi jarak 0 cm hingga 1,5 cm terdapat pada temperatur 1400C yakni sebesar 13,87kV, 21,07kV, 32,52kV, dan 39,78kV. Sementara paling tinggi saat temperatur minyak 950C sebesar 15,47 kV, 23,38 kV, 35,42 kV, dan 41,12 kV. Nilai harapan hidup transformator pada suhu 950C, 1080C, 1230C, dan 1400C masing-masing adalah 99,9973%, 99,9892%, 99,9518%, dan 99,7707%.

The following thesis is discussing the effect of temperature to insulation degradation and life expectancy of transformer’s liquid and solid insulation. The test result shows that the temperature will be inversely equivalent to breakdown voltage and will reduce the life expectancy of transformer’s insulation. The lowest breakdown voltage occurs at temperature of 1400C which values from 0 cm to 1,5 cm respectively are 13,87kV, 21,07kV, 32,52kV, dan 39,78kV. Whilethe highest occurs at 950C which values from 0 cm to 1,5 cm respectively are 15,47kV, 23,38kV, 35,42kV, and 41,12kV. Life expectancy values of transformer’s insulation at temperature of 950C, 1080C, 1230C, and 1400C respectively are99,9973%, 99,9892%, 99,9518%, dan 99,7707%.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S52585
UI - Skripsi Membership  Universitas Indonesia Library
cover
M Andre Arsyandy
"Isolasi antar kumparan pada transformator daya tersusun dari material kertas dan minyak. Dimana usia dari sebuah transformator biasanya dibatasi oleh usia dari isolasi kertasnya. Dengan pengukuran respon dielektrik pada isolasi antar kumparan di transformator daya, tingkat kandungan air pada isolasi padat serta tingkat konduktivitas pada isolasi minyaknya dapat diketahui. Pengukuran respon dielektrik pada rentang frekuensi yang luas, yakni antara 1 mHz hingga 1 KHz, mampu memberikan Gambaran mengenai karakteristik dari masing-masing material isolasi. Metode yang sedang dikembangkan untuk mendetekasi kondisi isolasi kertas-minyak pada transformator daya dikenal dengan Dielectric Frequency Response (DFR).
Skripsi ini membahas mengenai analisis kondisi isolasi antar kumparan pada transformator berdasarkan standar IEC 60422, analisis dan perbandingan hasil pengukuran DFR pada beberapa transformator yang berbeda, dan pengaruh usia transformator terhadap hasil pengukuran. Pengukuran respon dielektrik antar kumparan pada transformator daya digunakan untuk memperkirakan tingkat kandungan air pada isolasi padat seperti kertas. Pengukuran dilakukan pada lima buah transformator dengan kapasitas yang berbeda-beda, yakni 190, 145, 70, 4 MVA dua kumparan dan 412,2 MVA tiga kumparan. Secara berurutan, hasil yang didapat menunjukkan tingkat kelembaban trafo sebesar 0.2, 0.9, 1.6, 1.2, dan 1 %. Dan dari hasil pengukuran juga diketahui bahwa semakin tua usia transformator maka tingkat kelembabannya semakin tinggi.

The insulation between windings in power transformer is consist of cellulose material and oil mineral. The life of a transformer is usually limited by the life of the cellulose insulation. By measuring the frequency response from the main insulation between windings in power transformer, moisture content on the solid insulation and level conductivity on the oil mineral can be estimated. Dielectric response measurement over a wide frequency range, i.e between 1 mHz ? 1 kHz, can determine different properties of the insulation materials. Methods are being developed to detect the condition of oil-paper insulation, known as Dielectric Frequency Response (DFR).
This thesis discusses about analysis of insulation condition between windings in power transformer based on IEC 60422 standard, analysis and comparison of DFR measurement result from some different transformers, and influence from the age of transformers to measurement result. Dielectric response measurement between windings of power transformers is used to estimate the water content of the solid insulation. The measurement is applied to five transformers with different rate, i.e 190, 145, 70, and 4 MVA Power rated transformers. The result shows moisture level with 0.2, 0.9, 1.6, and 1.2 % water content. And from the result, also known that the ageing of transformer will increase moisture level in the solid insulations."
Depok: Fakultas Teknik Universitas Indonesia, 2014
S53238
UI - Skripsi Membership  Universitas Indonesia Library
cover
Reza Insan Meidiansyah
"Arus inrush merupakan salah satu fenomena yang terjadi pada sistem tenaga listrik khusunya pada transformator. Arus ini dapat menyebabkan kesalahan kerja proteksi pada sistem sehingga akan mengganggu keandalan sistem tenaga listrik. Arus inrush berbeda dari arus gangguan, dimana arus inrush hanya terjadi oleh beberapa kasus saja, dan yang paling banyak terjadi yaitu saat inti transformator pertama kali di beri energi. Besarnya arus inrush dapat dipengaruhi oleh beberapa hal, salah satu hal yang dapat memberikan pengaruh tersebut adalah variasi beban yang dihubungkan pada transformator sekunder. Selain pada transformator arus inrush juga dapat terjadi pada beban rumah tangga, arus ini dapat mengganggu kerja dari sirkuit breaker pada instalasi listrik rumah tangga. Besar arus inrush yang terjadi pada beban rumah tangga juga dipengaruhi oleh sifat beban itu sendiri.

Inrush current is one of the phenomena that occur on the power system especially on the transformer. This current can cause errors in the protection system so that it will disturb the reliability of power system. Inrush current is different from fault current, where inrush current occur in a few cases only, and it happen mostly when the transformer energized. Magnetizing inrush current magnitude can be affected by several things, one of the things is the variation of the load that connected to the secondary transformer. Inrush current can also occur in household electrical load, these current can disturb the circuit breaker in the electrical installation of the household. Magnitude of these inrush current is also influenced by the nature of the load itself."
Depok: Fakultas Teknik Universitas Indonesia, 2014
S54747
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Triaji
"ABSTRAK
Teknologi Body-Centric Wireless Communication dalam beberapa tahun terakhir ini telah menarik perhatian dunia. Tidak hanya dari bidang kesehatan yang memanfaatkan teknologi ini, di bidang olahragapun sudah ada perusahaan besar yang menggunakan teknologi ini. Body-Centric Wireless Communication ini terbagi menjadi 3 bagian yaitu in-body, on-body dan off-body communication. Pada sistem komunikasi ini, kinerja sistem dipengaruhi oleh interaksi gelombang elektromagnetik dengan tubuh. Oleh karena itu, sangatlah penting untuk mengetahui pengaruh tubuh terhadap kinerja antena, karena pada setiap bagian tubuh memiliki karakteristik listrik yang berbeda. Pemodelan karakteristik tubuh biasanya diperlukan untuk mendapatkan hasil kinerja antena yang akurat. Pada penelitian ini, dirancang antena tag dengan bentuk P-IFA yang dicatu dengan teknik coplanar waveguide (CPW) untuk komunikasi off/on-body pada frekuensi 2,45 GHz. Antena kemudian ditempel pada tubuh manusia atau diletakkan di dekat tubuh pada sekitar jarak 3mm. Antena yang dirancang memiliki ukuran yang kecil agar dapat diinstalasi di dekat tubuh manusia dengan mudah. Hasil simulasi antena di kondisi udara bebas, antena memiliki frekuensi resonansi pada 2,63 GHz dengan nilai S11 -20,75 dB, bandwidth 169 MHz dan gain 1,22 dB. Ketika antena diletakkan dekat tubuh manusia atau pada phantom 3 lapis frekuensi bergeser ke 2,45 GHz dengan nilai S11 -17,05 dB dengan bandwidth 245,8 MHz. Selanjutnya kondisi antena saat diletakkan dengan phantom ekivalen otot memiliki nilai S11 pada frekuensi 2,45 GHz yaitu sebesar -17,60 dB dengan bandwidth 217 MHz dan gain sebesar -7,41 dB. Pada pengukuran, nilai S11 saat kondisi antena di udara bebas sebesar -34,87 dB pada frekuensi 2,63 GHz dengan bandwidth 137 MHz dan gain 1,74 dB. Saat antena diletakkan dekat dengan tubuh, frekuensi bergeser ke 2,45 GHz dengan nilai S11 -16,78 dB dan bandwidth sebesar 174 MHz. Setelah itu pengukuran dilakukan pada kondisi antena diletakkan pada phantom ekivalen otot. Hasil pengukuran S11 pada frekuensi 2,45 GHz ialah sebesar -18,29 dB dengan bandwidth 169 MHz dan gain -9,06 dB. Dengan demikian, antena yang dirancang dapat bekerja dengan baik pada frekuensi 2,45 GHz.

ABSTRACT
The body centric wireless communication technology has in these few years attracted the world's attention. Not only in the medical field it's uses can be , it extends it's reach even towards giant sport companies. Body centric wireless communication is comprised from 3 categories, of which are the in body, on body and off body communication. In this kind of communication system, the performance of the system will be affected by the interactions between the body and electromagnetic wave. Hence, its necessary to understand the effect of body proximity towards antennas performance, as every body parts have different electrical characteristics. As a result, making a simple model of human's body might be necessary to achieve excellent performance from the antenna.
In this research, a tag antenna is being design with a printed inverted f shape, which powered by the coplanar waveguide (CPW) for on/off body communications on the ISM band 2.45 GHz. The tag antenna will then be attached to a human body, as close as 3mm from the skin. The smaller shape is more desired, as it will be easier to attach on human body.
The simulation result in freespace shows that this antenna's resonant frequency is 2.63 GHz with the S11 value as low as -20.75 dB, while the bandwidth is 169 MHz and gain is 1.22 dB. When the antenna is within the proximity of human body or a 3 layered phantom in this case, the frequency will shifts to 2.45 GHz along with the S11 of -17.05 dB. Due to the proximity of the phantom, the bandwidth will be 245.8 MHz wide. Also following, a condition where the antena is attached in a muscle equivalent phantom which resulting in -17.60 dB of S11 value at the frequency of 2.45 GHz with the bandwidth of 217 MHz and -7.41 dB gain.
In measurement, the S11 in freespace is -34.87 dB at the frequency of 2.63 GHz while the bandwidth and gain shows 137 MHz, and 1.74 dB respectively. Then it is brought to the proximity of a human body which resulting in the shifts of resonant frequency to 2.45 GHz, S11 to -16.78 dB and bandwidth tp 174 MHz. As part of the progress, the antena is attached on a muscle equivalent phantom. The measurements shows that S11 is -18.29 dB at the frequency of 2.45 GHz, while bandwidth and gain are in the value of 169 MHz and -9.06 dB respectively.
In conclusion, the antenna designed can work excellently at the frequency of 2.45 GHz."
Fakultas Teknik Universitas Indonesia, 2014
S62166
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Shaugi
"Database merupakan bagian terpenting dari suatu aplikasi dan perlu untuk diamankan.Pada tesis ini diajukanlah suatu konsep dasar penerapan algoritma negative database (NDB) yang bersamaan dengan algoritma enkripsi.Kemudian dilakukanlah pengujian performansi dari algoritma AES-128 dan Blowfish-448 yang masing-masing dikombinasikan dengan algoritma NDB, untuk kemudian dipilih kombinasi yang terbaik untuk diterapkan pada aplikasi Simple-O.Hasil pengujian algoritma NDB yang dirancang menunjukkan kesesuaian dengan konsep dasar yang diajukan. Setelah dikombinasikan dengan masing-masing algoritma AES-128 dan Blowfish-448, maka didapatkan hasil rata-rata CPU time AES-128 + NDB dan Blowfish-448 + NDB masing-masing sebesar 0.0030 detik dan 0.0037 detik pada proses enkripsi, dan 0.0054 detik dan 0.006 detik padaproses dekripsi. Rata-rata memory usage AES-128 + NDB dan Blowfish-448 + NDB masing-masing sebesar 9.03 kB dan 9 kB pada proses enkripsi, dan 11.67 kB dan 11.61 kB pada proses dekripsi. Rata-rata processing time AES-128 + NDB dan Blowfish-448 + NDB masing-masing sebesar 1.94 ms dan 2.77 ms pada proses enkripsi, dan 4.34 ms dan 5.03 ms pada proses dekripsi. Sedangkan rata-rata throughput AES-128 + NDB dan Blowfish-448 + NDB masing-masing sebesar 385.89 B/ms dan 275.74 B/ms pada proses enkripsi, dan 156.18 B/ms dan 136.55 B/ms pada proses dekripsi.

Database is an important part of an application and need to be secured. In this thesis it was proposed a basic concept of the implementation negative database algorithm (NDB) alongside encryption algorithm. Then perform the performance testing of AES-128 and the Blowfish-448 algorithm, which each combined with NDB algorithm, and then selected the best combination to be applied to Simple-O applications. Testing results of NDB algorithms designed show compliance with the basic concepts proposed. After combined with each algorithm AES-128 and Blowfish-448, then obtained an average yield CPU time AES-128 + NDB and Blowfish-448 + NDB respectively 0.0030 seconds and 0.0037 seconds in the encryption process, and 0.0054 seconds and 0.006 seconds in the decryption process. The average memory usage of AES-128 + NDB and Blowfish-448 + NDB respectively 9.03 kB and 9 kB on the encryption process, and 11.67 kB and 11.61 kB in the decryption process. The average processing time of AES-128 + NDB and Blowfish-448 + NDB respectively 1.94 ms and 2.77 ms on the encryption process, and 4.34 ms and 5.03 ms in the decryption process. While the average throughput of AES-128 + NDB and Blowfish-448 + NDB respectively 385.89 B/ms and 275.74 B/ms in the encryption process and 156.18 B/ms and 136.55 B/ms in the decryption process."
Depok: Fakultas Teknik Universitas Indonesia, 2013
T35059
UI - Tesis Membership  Universitas Indonesia Library