"In Indonesia presently there still exist some power plants with 1960s technology which are operated manyally. The aim of this paper is to design an automatic voltage goes back to the reference value when any disturbance occurs. The design result can be applied to newly built power plants as well as to modernize old power plants. The design uses model matching methods. With model matching method the regulator is designed so that the trnasfer function of the designed control system resembles that of the reference model. Its performance was validated through computer simulation using electrical power nonlinear model of 4th order. from simulation when the reference was changed the following tracking performance was obtained: rise time 1.7 sec, over shoot 7,3 % and settling time 5.7 . sec. On the oder hand, from the fault simulation the following regulation performance was obtained: over shoot 4 % settling time 4.7 sec. and steady state error 0%."
KEENTER
Artikel Jurnal  Universitas Indonesia Library
cover
Fariz Hazmi Ahdiyat
"[Skripsi ini membahas tentang Over Load shedding pada subsistem Kembangan jaringan PT. PLN APB Jakarta dan Banten. Pelepasan beban dilakukan dengan tujuan melindungi sistem dari keruntuhan total (blackout) akibat beban lebih dan menaikkan tegangan sistem yang mengalami susut tegangan sampai batas toleransi nilai yang diizinkan yaitu +10 % dan -10 %. Simulasi dilakukan dengan menggunakan perangkat lunak ETAB 12.6. Pelepasan beban dibuat dengan 3 skenario. Skenario 1 berdasarkan nilai besar beban. Skenario 2 berdasarkan nilai susut tegangan. Skenario 3 berdasarkan jumlah daya yang dapat dilepas. Total daya pada sistem sebesar 650,35 MW. Beban maksimal yang dapat diterima oleh masing-masing IBT adalah 458 MW. Sehingga perlu dilakukan pelepasan beban sebesar 29,6%. Dengan melihat besarnya daya yang dilepas dan nilai susut tegangan rata- rata pada setiap skenario, skenario yang paling optimal adalah skenario 2, dengan susut tegangan rata-rata 7,38% dan beban yang dilepas sebanyak 198,27 MW.

, This thesis discusses Overload shedding on Kembangan subsystem PT. PLN APB Jakarta and Banten grid. Load shedding is done in order to protect the system from total collapse (blackout) due to overload and stabilized voltage system to the value of the permitted tolerance +10% and -10%. Simulations done using software ETAB 12.6. Load shedding created with 3 scenarios. Scenarios 1 is based on the value of the loads. Scenario 2 is based on the value of undervoltage. Scenario 3 is based on the amount of power that can be removed. The total power in the system amounted to 650.35 MW. The maximum load that can be accepted by each IBT is 458 MW. So it is necessary to release the load by 29.6%. By looking at the amount of power that is removable and the average value of undervoltage on each scenario, the optimal scenario is scenario 2, the average of undervoltage is 7.38% and the load shedding as much as 198.27 MW
D]
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S61694
UI - Skripsi Membership  Universitas Indonesia Library
cover
Eko Wahyu Supriyadi
"ABSTRAK
Peningkatan keandalan sistem tenaga lisirik adalah suatu tuntutan dalam rangka usaha untuk meningkatkan pelayanan terhaLlap konsumen listrik Pelayanan yang baik adalah menjadi tujuan pada setiap pengusahaan sistem tenaga listrik.
Sistem distribusi sebagai bagian dari sistem tenaga listrik, merupakan bagian terbesar asal mula terjadinya pemutusan pelayanan. OIeh karena itu tingkat keandalan suatu sistem distribusi penlu diketahui untuk memperoleb mutu pelayanan yang diinginkan.
Tingkat keandalan sistem disiribusi ditentukan oleh unjuk kerja masing-masing komponen yang mendukung beroperasinya sistem distribusi tersebut Dengan diketahuinya tingkat keanda1an sistem distribusi akan dapat diambil kebijaksanaan untuk lebih meningkatkan pelayanan.

"
1995
S34291
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lintang Hapsari Wilujeng
"

Sumber tegangan listrik merupakan salah satu kebutuhan primer modern di masa sekarang.Sumber tegangan listrik mutlak dibutuhkan untuk menjamin tetap bekerjanya peralatan tersebut.

Namun masalah yang sering dihadapi seringkali adalah sumber-sumber tegangan memiliki nilai yang jauh dibawah level tegangan kerja yang umumnya digunakan pada sistem jaringan listrik perumahan. Untuk mengatasai permasalah sumber tegangan DC tersebut, salah satu cara yang dapat diambil adalah dengan mengimplementasikan sebuah rangkaian pengubah nilai tegangan DC atau DC-DC Converter.

Pada penelitian ini penulis menawarkan rangkaian DC-DC Converter dari tipe terisolasi, yaitu Push-Pull Converter. Pemilihan Push-Pull Converter dilakukan atas beberapa alasan antara lain keandalan, kualitas daya yang dihasilkan, kemudahan untuk diaplikasikan serta yang paling penting adalah ketahanan dari gangguan yang mungkin terjadi.

Sistem dikendalikan dengan menggunakan Pengendali PI dan IP serta diuji kualitasnya dengan menggunakan Diagram Bode.Hasil dari simulasi serta analisa kestabilan menunjukkan bahwa Rangkaian Push-Pull adalah rangkaian yang tahan terhadap gangguan.


Power supply is one of the modern primary needs in the present. Power supply is absolutely necessary to ensure the continuity cooperation of the equipment. However, a problem that often encountered is voltage sources values are far below the working voltage levels that are generally used in residential electrical grid system. To handling the problems of the DC voltage source, one way that can be taken is to implement a DC voltage converter circuit or DC-DC Converter.

In this research, a series of isolated type DC-DC Converters, namely Push-Pull Converter, is being promoted. The Selection of Push-Pull Converter based on reliability and quality of generated power among others, ease of applicability and the most important is the robustness of the interference that may occur.

The system is controlled using a PI controller and the IP also stability tested using Bode plots. The results of simulation and analysis shows that the stability of the Push-Pull circuit is a circuit that is resistant to interference.

"
Fakultas Teknik Universitas Indonesia, 2014
S56862
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adhistira Madhyasta Naradhipa
"Untuk melakukan pengujian terhadap sistem proteksi petir pada skala laboratorium diperlukan pembangkit tegangan tinggi impuls dimana membutuhkan masukan tegangan yang cukup tinggi untuk menghasilkan pelepasan muatan dalam jarak tertentu. Kapasitor pengisi harus dibuat cukup besar agar dapat menahan tegangan masukan yang tinggi sehingga akan memakan biaya dan tempat yang besar. Erwin Otto Marx pada tahun 1923 menemukan rangkaian pembangkit tegangan tinggi impuls banyak tahap atau yang sering disebut sebagai marx generator dimana rangkaian tersebut dapat menghasilkan tegangan yang tinggi dengan masukan tegangan yang rendah. Marx generator yang dibangun terdiri dari 10 tahap dan dibuktikan bahwa dengan masukan tegangan 5kV-7.5kV dapat menghasilkan tegangan pulsa 29.14kV-43.6kV dimana persamaan estimasi tegangan keluaran adalah . Dibuktikan juga bahwa dengan keluaran tegangan tersebut dapat terjadi tegangan tembus di udara sampai dengan 1.5 cm untuk jenis sela udara jarum-pelat.

To conduct a test for lightning protection system on a laboratory scale we need high impulse voltage generator. A high impulse voltage generator need high input voltage, therefore the components of the generator have to be build strong enough to hold the stress from the high input voltage. Erwin Otto Marx found multistage high impulse voltage generator or often called marx generator, the marx generator only need low input voltage to generate high pulse voltage so the components of marx generator didn?t have to be strong enough to hold overall output voltage. The marx generator that i have build is consist of 10 stages and proven that with input voltage 5kV-7.5kV can produce 29.14kV- 43.6kV pulse voltage with the formula of voltage output estimation is . Also it proven with that pulse voltage it produce a voltage breakdown in the air up to 1.5 cm for rod-plate spark gap."
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59544
UI - Skripsi Membership  Universitas Indonesia Library
cover
Simamora, Jonathan Fritz
"Tegangan tembus merupakan suatu indikator penting dalam menentukan baik buruknya kualitas isolasi dari suatu isolator, termasuk dalam isolasi cair. Tegangan tembus dari isolasi cair berbeda-beda untuk setiap jenis minyak yang berbeda pula. Ada beberapa hal yang berpengaruh terhadap penurunan nilai tegangan tembus dan kualitas isolasi dari isolator cair ini, dan beberapa diantaranya merupakan kenaikan temperatur dan umur minyak transformator tersebut. Kenaikan temperatur minyak terjadi akibat transformator tersebut dipakai dalam kondisi beban yang tinggi secara terus menerus.
Umur minyak transformator sendiri dihitung berdasarkan lamanya minyak tersebut dipakai di dalam transformator tersebut. Pengujian pengaruh kenaikan temperatur dan umur minyak terhadap tegangan tembus perlu dilakukan untuk mengetahui degradasi dari tegangan tembus minyak transformator tersebut sebagai salah satu indikator baik buruknya isolasi cair suatu transformator daya.

Breakdown voltage is an important indicator in determining whether the quality of the isolation of an insulator is good or bad, including liquid insulation. Breakdown voltage of liquid insulation is different for each different type of oil. There are several things that influences the decline in value of breakdown voltage and insulation qualities of this liquid insulator and some of which are the temperature rise and age of the transformer oil. The rising temperatures of the transformer oil is happened because the transformer was used in high load conditions continuously.
The age of transformer oil is calculated based on the length of the oil itself is used in the transformer. Testing the effect of temperature rise and the transformer oil?s age to breakdown voltage is necessary to know the degradation of transformer oil breakdown voltage as one indicator of the merits of a power transformer liquid insulation.
"
Depok: Fakultas Teknik Universitas Indonesia, 2011
S1049
UI - Skripsi Open  Universitas Indonesia Library
cover
Angga Hardiyantomo
"Analisis sistem tegangan fasa dalam keadaan tak seimbang dapat dengan mudah dihitung tanpa menggunakan perhitungan matematis rumit yang sangat kompleks. Skripsi ini menunjukan cara pengaplikasian dan perhitungan sederhana dengan menggunakan metode analisis trigonometri dan metode dekomposisi grafis. Dengan hanya diketahui nilai data numerik awal hasil pengukuran yang berupa tegangan salurannya maka dapat dihitung nilai tegangan urutan fasa, sudut fasa dan letak pergeseran titik netralnya dengan mudah. Cara dan metode ini dapat digunakan untuk mencari nilai dari ketidakseimbangan sistem yang terjadi di lapangan.

This paper show that analysis of phase voltage on unbalance voltage systems can be calculate exactly without the applications of the complex mathemathics. This paper can show two methods to calculate, the trigonometric analysis methods and graphical decomposition methods. Based on numerical data magnitude of line voltage measurements, can be calculate of voltage phase sequence, phase angle, and shift the location of neutral point. This result in a convenient procedure to assess voltage unbalance in the field. The phase relationships between the sequence and line components can also be calculated.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S57427
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Pradana Damara Armanda
"Penurunan intensitas lux pada ruangan dapat terjadi karena Voltage Drop atau penurunan tegangan. Penurunan tegangan ini mempengaruhi standarisasi lux yang ada pada ruangan sehingga tingkat pencahayaan pada suatu ruangan tidak optimal. Pada penelitian ini, lux yang dibutuhkan untuk ruang laboratorium lembaga pendidikan sebesar 500 lux untuk satu ruangan. Dalam skripsi ini akan dilakukan pengujian berupa variasi tegangan, daya, dan jumlah lampu untuk mendapatkan hasil yang optimum dalam penerangan. Pengujian ini menggunakan lampu Philips tipe CFL (Compact Flouresecent Light) pada variasi 23 Watt, 32 Watt, dan 42 Watt yang dipusatkan pada satu titik lampu. Tegangan yang diberikan memiliki rentang antara 220 Volt sampai 150 Volt dengan interval tegangan sebesar 5 Volt untuk tiap-tiap sampel. Untuk mencapai lux yang diinginkan (500 lux), maka diperlukan penambahan titik lampu sehingga intensitas lux yang diberikan akan semakin besar dan dapat memenuhi standar. Selain itu, dapat diketahui seberapa besar konsumsi Watt yang akan digunakan untuk memenuhi standar 500 lux sehingga tidak memerlukan biaya yang besar untuk konsumsi daya listrik.

Decreasing of lux intensity in the room can happen because Voltage Drop. This Voltage Drop had given an effect to lux standardization in room so that light intensity in the room can?t be optimal. In this research, lux which obtained for education laboratory equals to 500 for one room. In this script, the research will be tested with voltage, power, and lamps to get the optimal result for lighting. This test used CFL (Compact Flouresecent Light) Philips Lamps with 23 Watt, 32 Watt, and 42 Watt variations which centralized on one focus in the middle of room. The voltage is given between 200 Volt to 150 Volt with 5 Volt interval for its sample. To get the required lux (500 lux), needed spot light added so that lux intensity that given will be increased and the lux can reach the standard. Moreover, the consumption of electrical power can be known to reach 500 lux so that no need the high cost to consume much electrical power."
Depok: Fakultas Teknik Universitas Indonesia, 2015
S60445
UI - Skripsi Membership  Universitas Indonesia Library