Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 87628 dokumen yang sesuai dengan query
cover
Ariono Verdianto
"Dosimeter luminisensi LiF:Mg,Ti (TLD-100) merupakan detektor yang memiliki densitas material hampir ekivalen dengan jaringan tubuh manusia dan merupakan pilihan detektor yang terbaik untuk pengukuran dosis radiasi in vivo. Selain itu, TLD-100 memiliki kelemahan seperti ketidakseragaman respon, efek fading, dan ketergantungan respon energi. Keberadaan fading dan variasi sensitivitas sangat mempengaruhi respon TLD. Detektor TL memiliki respon yang bersifat tidak linier dari rentang dosis rendah sampai dosis tinggi. Keakurasian dalam estimasi dosis sangat penting dalam melakukan audit dosimetri.
Dalam penelitian ini dilakukan usaha peningkatan akurasi proses bacaan TLD melalui pengurangan variasi respon TLD dengan memperkecil rentang rata-rata respon pada nilai ±3%, penentuan faktor koreksi fading berdasarkan variasi respon TLD 0.05%, mencari respon TLD terhadap perubahan energi pada rentang RQR dan Cobalt 60. Selain itu dilakukan juga evaluasi penggunaan metode bacaan menggunakan kondisi TTP dosis rendah dan TTP dosis tinggi.
Berdasarkan pengelompokan TLD dengan variasi respon 0.05%, diperoleh koreksi fading y = 122.962 x-0.049, fungsi ini dapat digunakan untuk mengkoreksi bacaan TLD jika pembacaan dilakukan pada hari yang berbeda. Dengan menggunakan variasi respon TLD 3% diperoleh respon TLD yang menurun pada RQR4-RQR7, dan menaik pada RQR8-RQR15. Diketahui pengaruh pengaturan TTP memberikan perbedaan rasio bacaan dosis rendah terhadap dosis tinggi pada TLD yang berdampak nilai faktor kalibrasi TLD berubah sebesar 1.05, 1.03, dan 1.05 berturut dengan tegangan tabung 40, 70 dan 150 kV, sedangkan untuk cobalt 60 dengan variasi dosis 2, 1, dan 0.1 Gy perbandingannya sebesar 0.95, 0.96, dan 1.00. Estimasi ketidakpastian gabungan tipe A dan tipe B diperoleh rata-rata adalah sebesar 5.77% dengan batas tingkat kepercayaan 95%, dua standar deviasi.

Luminiscent dosemeters LiF: Mg, Ti (TLD-100) is detector that has an equivalent density material compare to human tissue and the best choice for in-vivo radiation dose measurement. On the other hand, TLD-100 has some weaknesses such as the ununiform responses, fading effects, and energy response dependent. The presence of fading and variations of sensitivity are greatly affect to the response of TLD. The response of detector TL is not linear from low dose up to high dose. Accuracy in dose estimation is essential in performing dosimetry audit.
This study aim to increase the accuracy of TLD reading process by reducing the variation response of TLD with minimizing the response range within ± 3%, measuring of the fading correction factor using TLD with response variation ±0.05%, determining TLD response dependency in energy RQR range and Cobalt 60. In addition, this work also evaluate the reading method using low and high dose TTP setting. Based on ±0.05% TLD response variation grouping, fading correction function is y = 122.962 x-0.049, this function can be used to correct the TLD readings when readings performed on different day.
By using a variation of TLD response ±3%, it is found there is a decreased response in TLD, over RQR4-RQR7, and an increased over RQR8-RQR15. It is found that different setting of TTP will affects readings result low dose ratio with the high dose will change on TLD of calibration factor value 1.05, 1.03, and 1.05 respectively with a tube voltage of 40, 70 and 150 kV, while for cobalt 60 with variation of doses around 2, 1, and 0.1 Gy the value of ratio around 1.05, 1.04, and 1.00. Estimation uncertainty both of type A and type B are obtained on the average of 5.77% with a limit of level confidence 95%, two standard deviations.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S1646
UI - Skripsi Open  Universitas Indonesia Library
cover
Bondan Kanigoro
"Telah dilakukan penelitian mengenai membangun suatu rancang bangun ratemeter menggunakan detektor NaI Tl berbasis mikrokontroler Dimana menghitung jumlah cacahan suatu radiasi sinar gamma dari suatu unsur radioaktif Cacahan tersebut terukur dari pulsa pulsa listrik yang dihasilkan dari detektor NaI Tl Detektor yang terdiri dari scintillator dan tabung photomultiplier dapat mendeteksi adanya suatu aktivitas radioaktif Menggunakan unsur Amerisium 241 Am 241 sebagai sumber radioaktif dan mengukur tingkat cacahan radioaktif terhadap tingkat perubahan tengan detektor yang digunakan Menentukan daerah Plateau dari detektor yang digunakan pada tegangan 1000V sampai dengan 1020V dengan daerah kerja optimal detektor pada tegangan 1010V Membandingkan ratemeter yang telah dibuat dengan surveymeter yang terkalibrasi dengan hasil cacahan terhadap perubahan jarak radioaktif yang digunakan.

Has conducted research on building a design ratemeter using NaI detector Tl based microcontroller Where counting the number of counts of a gamma ray radiation from a radioactive element The initial count of measurable electrical pulses generated from the detector NaI Tl Scintillator detector consists of a photomultiplier tube and can detect the presence of a radioactive activity Using Americium 241 Am 241 as a radioactive source and measuring the level of radioactive chopped the rate of change amid the detector used Determining the Plateau area of the detector used at voltages up to 1020V 1000V with optimal work area detector voltage 1010V Comparing ratemeter which has been made with SurveyMETER calibrated with the results of counts to changes in the use of radioactive distance."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S57116
UI - Skripsi Membership  Universitas Indonesia Library
cover
Panin, Giorgio
New jersey: John Wiley & Sons, 2011
006.3 PAN m
Buku Teks SO  Universitas Indonesia Library
cover
Febrianti M
"ABSTRAK
Penelitian ini bertujuan untuk memverifikasi distribusi dosis pada teknik 3D-CRT dan IMRT dengan menggunakan dosimeter TLD rod dan film gafchromic EBT3 pada kasus payudara yang telah dibuat di TPS berdasarkan data klinis di Siloam Hospital TB Simatupang. Penelitian ini dilakukan menggunakan Linac Trilogy dengan TPS menggunakan modul Eclipse versi 11 yang memproduksi berkas foton dengan radiasi 6 dan 10 MV. Film EBT3 dengan ukuran 4 4 cm2 diiradiasi menggunakan energi 6 MV dalam variasi dosis 0 - 260 cGy. Penelitian ini menggunakan lapangan radiasi 10 10 cm2. Film dipindai menggunakan flatbed scanner Epson V700 dalam evaluasi pixel value. Perhitungan dan plot antara netOD dan dosis untuk mendapatkan kurva kalibrasi yang digunakan untuk memperoleh dosis pengukuran pada pasien. TLD rod dengan ukuran 3 mm diiradiasi dengan energi 6 MV dalam dosis 200 cGy. TLD dibaca menggunakan TLD reader Harshaw dalam bentuk muatan coulomb. Perhitungan dan plot antara muatan dan dosis akan mendapatkan faktor kalibrasi yang digunakan untuk memperoleh dosis pengukuran pada pasien. TLD dan film EBT3 ditempelkan pada 5 titik di masker yang digunakan pasien dimana titik 1 daerah trakea, titik 2 daerah aksila, titik 3 daerah mammaria interna, titik 4 daerah nipple, dan titik 5 mammae inferior. Hasil perbedaan dosis menunjukkan penggunaan film gafchromic EBT3 pada verifikasi dosis titik kasus kanker payudara lebih baik daripada TLD rod pada teknik 3D-CRT dan teknik IMRT. Perbedaan dosis antara TPS dan film EBT3 dalam rentang 0,66 sampai dengan 5,67 teknik 3D-CRT dan -0,67 sampai dengan -7,57 teknik IMRT . Perbedaan dosis antara TPS dan TLD rod dalam rentang -2,63 sampai dengan 29,14 teknik 3D-CRT dan -16,41 sampai dengan -46,84 teknik IMRT . Uji statistika menunjukkan korelasi kuat 1,00 tetapi tidak signifikan sig < 0,05 serta terdapat perbedaan dosis titik rata-rata yang signifikan antara film EBT3 dan TLD rod pada kelompok pasien sebelum dan setelah dilakukan operasi. Tidak terdapat perbedaan dosis titik rata-rata antara kelompok sebelum dan setelah dilakukan operasi baik teknik 3D-CRT maupun IMRT dan tidak terdapat perbedaan dosis titik rata-rata antara teknik 3D-CRT dan IMRT.

ABSTRACT
The aim of thisresearch is to verify dose distribution in 3D CRT and IMRT by using TLD rod dosimeter and Gafchromic EBT3 films on breast cases that have been made in TPS based on clinical data at Siloam Hospital TB Simatupang.This research was conducted using Linac Trilogy with TPS using Eclipse module version 11 which produces photon beam with radiation of 6 and 10 MV.EBT3 films of size 4 4 cm2 were irradiated using 6MV photon beams in dose variation of 0 260 cGy. Radiation field of size 10 10 cm2 was used in this research. The irradiated EBT3 film was scanned using Epson V700 flatbed scanner to evaluate the pixel value. The calculation and plot between netOD and dose was used to get the calibration curve which will be used to obtain dose measurement for patients. TLD rod of size 3 mm was irradiated using 6 MV in dose variation of 200 cGy. TLD was read by using HarshawTLD reader in coulomb. The calculation and plot between netOD and dose will generate calibration factor used to get dose measurement for patients. TLD and EBT3 film were taped to 5 points in the mask used by patients where 1 point is the OAR trachea and 4 points is the PTV50. The results of dose difference at PTV50 with point orientation.TLD and EBT3 film were taped to 5 points in the mask used by patients wherethe first point is in the OAR trachea , the second point is in the axilla, the third point is in the mammaria interna, the fourth point is in the nipple, and the fifth point is in the mammae inferior. The result of differences in dose shows the use of gafchromic EBT3 film in dose verification on breast cancer is better than TLD rod in 3D CRT technique and IMRT technique. The dose difference between TPS and EBT3 film ranged from 0.66 to 5.67 3D CRT technique and 0.67 to 7.57 IMRT technique . The dose difference between TPS and TLD rod is in the range 2.63 to 29.14 3D CRT technique and 16.41 up to 46.84 IMRT technique . The statistical test showed a strong correlation 1.00 but insignificant sig "
2017
T47602
UI - Tesis Membership  Universitas Indonesia Library
cover
Aukerman, Robert C.
New York: John Wiley & Sons, 1981
372.4 AUK b
Buku Teks  Universitas Indonesia Library
cover
Elkin, Judith
London: Facet Publishing , 2004
418.4 Elk r
Buku Teks SO  Universitas Indonesia Library
cover
Roviani Amelia
"Curah hujan menjadi faktor cuaca yang sangat berpengaruh terhadap aktivitas penerbangan, mulai dari saat pesawat akan lepas landas, ketika berada di udara, dan saat akan melakukan pendaratan. Oleh karena itu, penelitian ini bertujuan untuk mengembangkan sebuah model prediksi curah hujan di Bandara Silangit, Tapanuli Utara yang memiliki variasi curah hujan yang tinggi, karena dipengaruhi oleh posisi geografisnya di dekat garis khatulistiwa. Model prediksi curah hujan tersebut dibangun dengan memanfaatkan data dari AWOS dan menerapkan algoritma XGBoost dan selanjutnya dioptimasi dengan menggunakan dua metode, yaitu random search dan bayesian optimization untuk mencari kombinasi hyperparameter optimal dan meningkatkan akurasi model prediksi tersebut. Hasil penelitian menunjukkan bahwa model XGBoost sebelum dioptimasi berhasil mencapai akurasi prediksi 74.8%. Sementara itu, dengan hyperparameter tuning melalui metode bayesian optimization, akurasi model meningkat hingga 76.6%, dengan kombinasi nilai hyperparameter optimal yang didapatkan, diantaranya max_depth: 17, min_child_weight: 3, learning_rate: 0.1, n_estimators: 100, subsample: 0.91, dan colsample_bytree: 0.88. Temuan ini menegaskan potensi yang besar dalam penggunaan teknologi canggih untuk prediksi curah hujan dalam rangka mendukung keselamatan penerbangan di wilayah dengan kondisi cuaca yang kompleks dan dinamis.

Rainfall is a weather factor that significantly affects aviation activities, from takeoff and in-flight operations to landing. Therefore, this study aims to develop a rainfall prediction model for Silangit Airport in North Tapanuli, an area with high rainfall variability due to its geographic location near the equator. The rainfall prediction model is constructed using data from the Automated Weather Observing System (AWOS) and employs the XGBoost algorithm, which is further optimized using two methods: random search and Bayesian optimization. These methods are used to find the optimal hyperparameter combinations and improve the model's prediction accuracy.The results of the study show that the XGBoost model achieved a prediction accuracy of 74.8% before optimization. However, with hyperparameter tuning using Bayesian optimization, the model's accuracy increased to 76.6%. The optimal hyperparameter values obtained were max_depth: 17, min_child_weight: 3, learning_rate: 0.1, n_estimators: 100, subsample: 0.91, and colsample_bytree: 0.88. These findings highlight the significant potential of advanced technology in predicting rainfall, thereby supporting aviation safety in regions with complex and dynamic weather conditions.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adi Teguh Purnomo
"Evaluasi dosis radiasi yang diterima pasien dapat dilakukan menggunakan metode dosimetri in-vivo dengan melakukan pengukuran dosis masukan yang didefinisikan sebagai dosis serap pada kedalaman maksimum. Dosimeter in-vivo yang digunakan adalah TLD-100 rod, Film Gafchromic EBT2, dan dioda EDP-153G yang dikalibrasi berdasarkan protokol IAEA dan ESTRO. Hasil faktor kalibrasidetektor dioda sebesar 0.0988 cGy/ADU dan 0.0966 cGy/ADU untuk protokol IAEA dan ESTRO sedangkan Faktor kalibrasidetektor TLD memiliki rata-rata perbedaan sebesar 3.69 ± 0.04 %. Selain itu, faktor koreksi dioda EDP-153G terhadap variasi SSD, luas lapangan, dan linieritas dosis berada dalam rentang nilai 0.99-1.01 untuk protokol IAEA dan ESTRO sedangkan faktor koreksi terhadap sudut sinar datang berada dalam rentang nilai 1.028 - 1.037 dan 1.027-1.057 untuk protokol IAEA dan ESTRO. Pengukuran dosimetri in-vivo dititikberatkan pada kasus kanker paru dan prostat dengan meletakkan dosimeter in-vivo diatas permukaan kulit untuk beberapa titik pengukuran. Dosis masukan yang diperoleh bervariasi untuk setiap titik pengukuran akibat adanya perbedaan fluence. Evaluasi dosis pada organ target juga ditentukan dengan meletakkan film Gafchromic EBT2 pada slab fantom Rando Alderson. Persentase error yang diperoleh terhadap dosis yang direncanakan yakni sebesar 0.03% pada film 1 dan 2.5% pada film 2 untuk kanker paru sedangkan untuk kanker prostat sebesar 5.88% untuk film 1 dan 5.50% untuk film 2.

Evaluation of the radiation dose received by the patient could be performed with the in-vivo dosimetry by mean of the entrance dose measurement which defined as the absorbed dose to the maximum depth. TLD-100 rod, Gafchromic EBT2 film, and diode EDP-153G were used as in-vivo dosimeters and calibrated by the IAEA and ESTRO protocol. The results of calibration factor for diode EDP-153G was 0.0988 cGy/ADU and 0.0966 cGy/ADU for the IAEA and ESTRO, respectively while the differences of mean percentage was 3.69 ± 0.04 % relative to IAEA protocol for TLD. In addition, a correction factor for diode EDP-15­3Gto the variation of SSD, field size, and dose linearity were within the range of0.99-1.01 for the IAEA and ESTRO while the angular correction factor was at 1.028-1.037 and 1.027-1.057 for the IAEA and ESTRO protocol, respectively. The in-vivo dosimetry measurement was concerned in lung and prostate carcinoma by putting the in-vivo dosimeters on skin surface at some points of interest. The entrance dose measurement was varied for each point of measurement due to difference of fluence. The target dose evaluation was also determined by placing the Gafchromic EBT2 Film into slab of Rando Alderson phantom. The percentage error to the planned dose was 0.03% at the film 1 and 2.5%at the film 2 for lung carcinoma while for prostate carcinoma was 5.88% for the film 1 and 5.50% for film 2.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S54915
UI - Skripsi Membership  Universitas Indonesia Library
cover
Steven, Laurence
Scarborough: Prentice-Hall, 1999
808.042 7 STE f
Buku Teks SO  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1999
S36892
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>