Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 81 dokumen yang sesuai dengan query
cover
Gyeong-jin
Seoul: Munidang, 2007
KOR 895.73 SIN s
Buku Teks  Universitas Indonesia Library
cover
Bernlef, J.
Amsterdam: Querido, 2007
BLD 839.313 BER o
Buku Teks  Universitas Indonesia Library
cover
Slot, B.J.
Leiden: E.J. Brill, 1991
R 953.67 SLO o
Buku Referensi  Universitas Indonesia Library
cover
Slot, Gerard
Eindhoven: Centerx, 1965
621.38 SLO f
Buku Teks  Universitas Indonesia Library
cover
Sangster, Alan J.
"This book describes and provides design guidelines for antennas that achieve compactness by using the slot radiator as the fundamental building block within a periodic array, rather than a phased array. It provides the basic electromagnetic tools required to design and analyse these novel antennas, with sample calculations where relevant. The book presents a focused introduction and valuable insights into the relevant antenna technology, together with an overview of the main directions in the evolving technology of compact planar arrays.
While the book discusses the historical evolution of compact array antennas, its main focus is on summarising the extensive body of literature on compact antennas. With regard to the now ubiquitous slot radiator, it seeks to demonstrate how, despite significant antenna size reductions that at times even seem to defy the laws of physics, desirable radiation pattern properties can be preserved. This is supported by an examination of recent advances in frequency selective surfaces and in metamaterials, which can, if handled correctly, be used to facilitate physics-defying designs. "
Switzerland: Springer Nature, 2019
e20509677
eBooks  Universitas Indonesia Library
cover
Adhitya Satria Pratama
"Untuk melakukan diagnosa dan evaluasi penanganan kasus medis, paramedis perlu melakukan pemindaian tubuh manusia. Beberapa teknologi pemindaian tubuh manusia yang telah ada di antaranya adalah CT-Scan dan MRI. Walaupun resolusi dan akurasi citra yang dihasilkan sangat baik, namun biayanya yang relatif mahal bagi masyarakat Indonesia dan kompleksitas peralatan CT-Scan dan MRI cukup menjadi isu yang penting. Salah satu alternatif teknik pemindaian tubuh manusia yang non-intrusif, non-invasif, dan relatif lebih murah adalah teknologi pencitraan kepala menggunakan gelombang mikro (microwave imaging).
Teknik pencitraan gelombang mikro memanfaatkan sifat gelombang mikro yang dapat menembus atau terhambur jika dihadapkan pada suatu objek dan karakteristik dielektrik sel tumor yang jauh berbeda dibandingkan sel yang sehat. Pada tesis ini dirancang bangun suatu perangkat pencitraan gelombang mikro yang terdiri dari perangkat keras berupa sistem antena, mikrokontroler, dan motor stepper serta perangkat lunak berupa pemrograman algoritma rekonstruksi citra proyeksi balik. Sistem antena ini berfungsi sebagai pengirim dan penerima gelombang elektromagnetik untuk mendapatkan parameter S21. Sistem antena, yang terdiri dari antena beserta network analyzer, terintegrasi dengan motor stepper dan mikrokontroler dalam pemrograman berbasis LabVIEW. Objek pengujian yang berupa model phantom yang terdiri dari dua lapisan dan daging sapi diletakkan di antara antena pengirim dan penerima pada frekuensi 3 GHz. Hasil pengujian berupa magnitudo koefisien atenuasi dari parameter S21 yang direkonstruksi untuk memperoleh citra objek menggunakan perangkat lunak MATLAB ®.
Kedua antena yang digunakan diukur untuk mendapatkan kinerja pada frekuensi 3 GHz meliputi parameter S11 dan pola radiasi. Pola radiasi antena dipol adalah omnidireksional, sedangkan antena tapered slot memiliki pola radiasi direktif. Berdasarkan hasil pengujian, sistem antena telah terintegrasi dengan perangkat lunak berbasis LabVIEW dan telah mampu mengambil data secara otomatis. Hasil pencitraan yang diperoleh menunjukkan bahwa antena dengan pola radiasi yang direktif relatif lebih terlihat jelas dibandingkan antena omnidireksional. Fluktuasi magnitudo koefisien atenuasi terjadi di setiap titik tertentu pada objek karena adanya perbedaan permitivitas relatif objek. Sistem pencitraan gelombang mikro telah berhasil diuji validitasnya meskipun hasil citramasih terdapat derau dan artifact yang timbul akibat interpolasi pada algoritma proyeksi balik.

MRI, PET, and CT are widely used modalities for human body scanning, which they can provide accurate and high resolution image. However, their costs are still relatively high particularly in developing countries with high population like Indonesia. Hence, it is desirable to develop a new imaging system that is affordable, easy to operate (portable), non-ionization (safe radiation) and use a non-invasive technique. Microwave imaging is considered as a suitably matched modality to those requirements.
The imaging system using microwave utilizes the microwave properties that can penetrate and be scattered when it is exposed to an object and the tumor cell?s dielectric characteristics, which usually has much different dielectric constant compared with the healthy cell. The microwave imaging system that is proposed in this thesis, consists of a set of hardware (an antenna system, microcontroller and network analyzer) and own-developed back projection-based image reconstruction algorithm. The antenna system uses either a pair of dipole antennas or pair of tapered slot microstrip antenna as a transmitter and a receiver of microwave in order to measure the S21 parameter. The antenna system, consisting of antennas and network analyzer, is integrated with the stepper motors and microcontroller by using LabVIEW program. Either a dual layer phantom or a slice of beef meat as the object is located between the transmitter and the receiver that are operated at 3 GHz. The magnitudes of attenuation coefficients obtained from the measured S21 are then reconstructed into an image using MATLAB® program.
Both tapered-slot and dipole antennas are measured to evaluate the S11 parameters and radiation pattern at frequency of 3 GHz. The dipole antenna has an omnidirectional radiation pattern while the tapered slot has a directive radiation pattern. The antenna systems has been evaluated and successfully integrated with LabVIEW program to automatically obtain the data. The reconstructed images show that the tapered-slot antenna provides clearer image rather than the dipole due to its directive pattern characteristics. Moreover, the magnitude of attenuation coefficients from both antennas are discussed, where the fluctuation occurs due to the relative permittivity differences of the object. The proposed microwave imaging system has been successfully evaluated for the validity on performing image reconstruction, although some of the reconstructed images still contain noise and artifacts due to interpolation algorithm process.
"
2015
T42926
UI - Tesis Membership  Universitas Indonesia Library
cover
"This paper proposes microstrip slot antenna fed by matching network of microstrip line to increase widebandwidth. The microstrip line composed of multi tuning stubs is used to control slots antenna's real impedance to match with the impedance characteristic of feeding line so that it could enhance the bandwidth...."
Artikel Jurnal  Universitas Indonesia Library
cover
Universitas Indonesia, 1998
S25706
UI - Skripsi Membership  Universitas Indonesia Library
cover
Henry Juandy
"Jaringan DQDB memiliki dua bush bus dimana setiap stasiun pads jaringan DQDB dihubungkan dengan kedua bus ini. Pada jaringan DQDB, waktu pengiriman data dibagi-bagi menjadi interval %vaktu tertentu yang disebut dengan slot. Satu slot hanya dapat membawa 53 byte informasi. Palo jaringan DQDB orisinil, suatu slot yang telah selesal menyampaikan paket data ke stasiun tujuan akan tetap membawa paket data tersebut hingga slot data mencapai ujung bus. Oieh karena itu sebuah slot data hanya dapat digunakan sekali saja selama transmisi dari kepala bus sampai ke ujung bus. Efisiensi penggunaan slot dapat ditingkatkan, jika jaringan DQDB menerapkan mekanisme slot reuse. Dengan mekanisme ini, slot data yang telah selesai menyampaikan paket data ke stasiun tujuan akan dibebaskan sehingga dapat digumakan kembali oieh stasiun-stasiun yang lain. Pada tulisan ini akan dicari lokasi optimal dari stasiun pembebas slot dengan mengasumsikan lalu iintas data pada jaringan adalah uniform. Kemudian akan dibuat simulasi jaringan DQDB yang menerapkan mekanisme slot reuse. Sebagai perbandingan unjuk kerja, tulisan ini juga akan mensimulasikan jaringan DQDB yang orisinil. Hasil uji cobs simulasi menunjukkan bahwa, dengan hanya menggunakan tiga stasiun pembebas slot dapat diperoleh throughput gain sebesar ,62."
Depok: Universitas Indonesia, 1997
S38803
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ruri Kharisma
"Probabilitas bloking merupakan satu faktor penting untuk standar tingkat pelayanan dalam sistem radio mobil seluler. Dengan demikian perlu dipikirkan suatu cara untuk memperkecil kemungkinan terjadinya bloking panggilan handover dengan maksud memperbaiki nilai GOS (Grade Of Service) system. Pelaksanaannya dilakukan dengan cara menyediakan sejumlah kanal cadangan yang khusus menangani panggilan handover.
Skripsi ini akan menganalisa jumlah kanal yang sudah disebutkan di atas dengan cara menghitung traffik perpindahan satu sel ke satu sel yang dikalikan dengan kecepatan.
Hasil akhir yang diperoleh memperlihatkan bahwa untuk parameter masukan sistem dengan tingkat mobilitas yang tinggi maka penerapan prioritas handover akan memberikan nilai GOS yang jauh lebih baik.

Blocking probability is an important factor for standard level of service in mobile cellular. There is a need to find a way to reduce the probability of handover blocking for improving Grade of Service value from a system. Reducing the probability of handover blocking can be implemented with providing backup channels for handling handover calls.
This script will analyze how many channels need to be provided. Amount of channels can be calculated from moving traffic times by velocity of the traffic.
Final result shows that there is an improvement in GOS value if we put a handover priority for high mobility system at certain input.
"
Depok: Fakultas Teknik Universitas Indonesia, 2009
S51120
UI - Skripsi Open  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9   >>