Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 6404 dokumen yang sesuai dengan query
cover
Egg, Jay
"This is the first definitive yet practical book to explain the rapidly growing field of geothermal air conditioning and heating technology for both residential and commercial applications."
New york: McGraw-Hill, 2011
697.04 EGG g (1)
Buku Teks  Universitas Indonesia Library
cover
Egg, Jay
"With a focus on market needs and customer goals, this practical guide explains how to realize the full potential of geothermal HVAC by integrating hydronic systems and controls at maximum capacity. This book explains how to engineer and specify geothermal HVAC for building projects in varying geographic regions. Typical details on control parameters are provided. By using the proven methods in this innovative resource, you will be able to develop highly efficient, long-lasting, and aesthetically pleasing geothermal HVAC systems"
New York: McGraw-Hill, 2013
697 EGG m
Buku Teks  Universitas Indonesia Library
cover
cover
Lechner, Norbert
697 LEC h
Buku Teks  Universitas Indonesia Library
cover
Yasmine Karenita
"Peningkatan jumlah emisi karbon menyebabkan pemerintah Indonesia memasang target bebas gas rumah kaca pada tahun 2060 dan membuat kebijakan penggunaan kendaraan listrik untuk mendukung tercapainya target tersebut. Pada kendaraan listrik, terdapat motor listrik yang berfungsi untuk mengonversikan energi listrik menjadi energi mekanik agar dapat bergerak, namun dalam proses konversi ini terjadi kerugian-kerugian yang menyebabkan temperatur motor meningkat. Temperatur motor yang terus meningkat hingga lebih dari 60℃ dapat menyebabkan penurunan performa dan kerusakan pada motor listrik, sehingga perlu adanya sistem pendinginan yang dapat mempertahankan temperatur motor listrik. Penelitian ini akan meneliti dan menguji Rotating Heat Pipe (RHP) sebagai sistem pendinginan pasif untuk motor listrik. Tujuan dari penelitian ini adalah untuk mengembangkan metode pengukuran untuk pengujian RHP dan mengetahui kinerja dari RHP. Penelitian ini menggunakan RHP dengan termokopel yang sudah terpasang di permukaannya. Penelitian ini juga menggunakan slip ringyang akan diuji kemampuannya ketika digunakan sebagai perantara antara modul akuisisi data dan sensor termokopel. Dari penelitian, diketahui bahwa slip ring dapat digunakan untuk menguji RHP karena kemampuannya untuk mengukur temperatur dalam kondisi berputar. Selain itu, penggunaan RHP juga mampu menurunkan resistansi termal sebesar 30-66% dibandingkan pipa kalor diam. 

The increase in carbon emissions has prompted the Indonesian government to set a target of carbon neutrality by 2060 and implement policies promoting the use of electric vehicles to support the achievement of this target. Electric vehicles are equipped with electric motors that convert electrical energy into mechanical energy to propel the vehicle. During this energy conversion process, the motor experiences an increase in temperature due to various losses that cause the motor temperature rise. If the heat continues to increase and the motor temperature exceeds 60°C, it will reduce the performance or even lead to damage. Therefore, there is a need for a cooling system that can maintain the electric motor's temperature within its working range. This study aims to investigate and test the Rotating Heat Pipe (RHP) as a passive cooling system for electric motors. The objectives of this research are to develop measurement methods for RHP testing and evaluate the performance of the RHP. The study employs an RHP with installed thermocouples on its surface. Additionally, a slip ring is utilized to test its capability as a connector of the data acquisition module and the thermocouple sensor. The research confirms that the slip ring can be used to test the RHP due to its ability to measure temperature under rotating conditions. Furthermore, the use of RHP can reduces thermal resistance by 30-66% compared to stationary heat pipes."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Davies, E.J.
London : Peter Peregrinus, 1990
621.402 DAV c
Buku Teks  Universitas Indonesia Library
cover
Kezia Dara Euodia
"Indonesia memiliki potensi geotermal yang sangat besar, meliputi entalpi-tinggi dan entalpi-rendah. Geotermal entalpi-rendah dapat dimanfaatkan sebagai sumber energi untuk CCHP, merupakan alternatif untuk memebuhi kebutuhan energi gedung komersial yaitupendingin, listrik, dan pemanas. CCHP dapat diaplikasikan di bangunan hotel dalam rangka konservasi energy menjadi green building. Pada penelitian ini diasumsikan bangunan hotel bintang lima akan didirikan di Kota Baru Meikarta membutuhkan energi sebesar 7941,81 kW yang terdiri dari pendingin, pemanas, dan listrik. Analisis kinerja teknis sistem CCHP menggunakan piranti lunak Cycle Tempo dilakukan dengan dua skenario utilisasi fluida panas bumi.
Hasil simulasi memperlihatkan bahwa dengan skenario fluida geotermal di bagi 15 menuju siklus pembangkit dan waste heat siklus tersebut digabungkan dengan 85 fluida geotermal menujusiklus pendingin dan sistem pemanas,. efisiensi sistem CCHP 36,34 dan penurunan emisi CO2 hingga 1,4459 tonCO2eq/tahun dapat dicapai. Simulasi borehole dengan kedalaman 400 m dan diameter 8 inci menggunakan piranti lunak COMSOL untuk mendapatkan profil temperatur dan kecepatan fluidageotermal. Analisis finansial dengan metode cash flow menggunakan Ms. Excel. Skema bisnis terbaik adalah Build, Own, Operate BOO dengan insentif fiskal, soft loan, dan grant sehingga biaya produksi energi adalah Rp1039/kWth, Rp1388/kWeh, dan Rp163.550/MMBtu secara berurutan untuk pendingin, listrik, dan pemanas.

As Indonesia located on the ring of fire, it has a massive geothermal reserve for both hig enthalpy and low enthalpy. Low enthalpy geothermal that is utilized as CCHP rsquo s source is the solution to fulfil energy demand in three outputs, which are cooling, heating, and power. CCHP based on low enthalpy geothermal application in hotel building is a form of energy conservation, which is green building. A five star hotel was assumed to be built in Meikarta City with total energy demand of 7941,81 kW that consist of cooling, heating, and electricity. Technical analysis for CCHP system uses Cycle Tempo program to simulate two scenarios.
The chosen scenario was scenario 2, which fresh geothermal was devided by 15 to power generation and the waste heat was merged with the other 85 of fresh geotermal to enter refrigeration and heating systems. The CCHP system efficiency was 36,34. The CO2 emission was decreased by 1,4459 tonCO2eq year from conventional source. Technical analysis for borehole uses COMSOL program, which depth of borehole is function of temperature and diameter is function of mass flow rate. The surface conditions of geothermal fluid were 149,5 oC and 1,2273 m s. Economics analysis uses Ms. Excel with cash flow method. The best business scheme is Build, Own, Operate with modifications of fiscal incentives, soft loan, dan grant. Therefore, the production prices are Rp1039 kWth, Rp1388 kWeh, and Rp163.550 MMBtu for cooling, electricity, and heating respectively.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
M. Hadi Kusuma
"Untuk meningkatkan keselamatan termal pada saat terjadi kecelakaan akibat station blackout, vertical straight wickless-heat pipe pipa kalor lurus tanpa sumbu kapiler yang diletakkan secara vertikal diusulkan sebagai sistem pendingin pasif baru untuk pembuangan panas sisa hasil peluruhan di kolam penyimpanan bahan bakar bekas nuklir. Pipa kalor akan membuang panas peluruhan dari kolam penyimpanan bahan bakar bekas nuklir dan dapat menjaga sistem tetap aman. Tujuan penelitian ini adalah untuk menginvestigasi karakteristik, fenomena perpindahan kalor, dan unjuk kerja termal pipa kalor yang digunakan mencari pengaruh kecepatan pendinginan dengan besarnya kalor yang harus dibuang, menganalisis keserupaan dimensi dari pipa kalor yang digunakan, dan mengetahui teknologi pipa kalor yang dapat digunakan sebagai sistem keselamatan pasif di instalasi nuklir pada kondisi kecelakaan akibat station blackout. Investigasi secara eksperimen dilakukan dengan mempertimbangkan pengaruh tekanan awal pipa kalor, evaporator filling ratio, beban kalor evaporator, dan laju aliran pendingin di water jacket. Air pendingin disirkulasikan dalam water jacket sebagai penyerap kalor di bagian condenser. Simulasi dengan program perhitungan termohidraulika RELAP5/MOD3.2 dilakukan untuk mendukung dan membandingkan dengan hasil eksperimen yang didapatkan. Hasil eksperimen menunjukkan bahwa unjuk kerja termal terbaik pipa kalor didapatkan pada tahanan termal 0,016 C/W. Unjuk kerja termal terbaik didapatkan pada saat pipa kalor diberikan filling ratio 80 , tekanan awal terendah, laju aliran pendingin tertinggi, dan beban kalor evaporator tertinggi. Dari nilai tahanan termal tersebut didapatkan bahwa pipa kalor ini memiliki kemampuan memindahkan kalor 199 kali lebih besar jika dibandingkan dengan batang pejal tembaga dengan geometri yang sama. Model pipa kalor dalam simulasi dengan RELAP5/MOD3.2 dapat digunakan untuk mendukung investigasi secara eksperimen dalam memprediksi fenomena yang berlangung di bagian dalam pipa kalor. Analisis dimensi dan keserupaan pipa kalor yang didapatkan bisa digunakan untuk merancang pipa kalor lain dengan geometri yang berbeda namun tetap menghasilkan unjuk kerja termal yang sama. Kesimpulan investigasi yang dilakukan menunjukkan bahwa pipa kalor ini memiliki unjuk kerja termal yang tinggi dan dapat digunakan sebagai sistem pendingin pasif di kolam penyimpanan bahan bakar bekas nuklir pada saat terjadinya kecelakaan akibat station blackout.

To enhance the thermal safety when station blackout accident occurs, a vertical straight wickless heat pipe is proposed as a new passive residual heat removal system in nuclear spent fuel storage pool. The heat pipe will remove the decay heat from nuclear spent fuel pool and keep the system safe. The objective of this research is to investigate the characteristics, heat transfer phenomena, and thermal performance of heat pipe, to analyse the effect of coolant flowrate against heat to be removed, analysing the dimensional similarity of heat pipe, and to know the heat pipe technology that could be used as passive safety system in nuclear installation during to station blackout accident. The experimental investigation was conducted to investigate the heat transfer phenomena and heat pipe thermal performance with considering the influence of heat pipe initial pressure, evaporator filling ratio, evaporator heat load, and coolant volumetric flow rate of water jacket. Cooling water was circulated in water jacket as condenser cooling system. A numerical simulation with nuclear reactor thermal hydraulic code RELAP5 MOD3.2 was performed to support and to compare with the experimental results. The experimental results showed that the best thermal performance was obtained at thermal resistance of 0.016 C W, with filling ratio of 80 , the lower initial pressure, higher coolant volumetric flow rate, and higher heat load of evaporator. From thermal resistance analysis, it is found that the heat pipe has the ability to remove heat 199 times greater than copper rod with the same geometry. The RELAP5 MOD3.2 simulation model can be used to support experimental investigation and to predict the phenomena inside the heat pipe. The dimensional analysis and similitude of the heat pipe can be applied to design the other heat pipe with different geometries with produces the same thermal performance. The conclusion of investigation showed that vertical straight wickless heat pipe has higher thermal performance and can be used as passive residual heat removal system of nuclear spent fuel pool when station blackout occurs."
Depok: Universitas Indonesia, 2017
D2297
UI - Disertasi Membership  Universitas Indonesia Library
cover
Lechner, Norbert
Jakarta: RajaGrafindo Persada, 2007
720 LEC h
Buku Teks  Universitas Indonesia Library
cover
Lechner, Norbert
Canada: John Wiley & Sons, 1991
697 LEC h
Buku Teks  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>