Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 4910 dokumen yang sesuai dengan query
cover
Looms, J.S.T.
Exeter: Short Run Press, 1988
621.319 37 LOO i
Buku Teks SO  Universitas Indonesia Library
cover
"This paper deals with the electrical insulation of a gap bridged by a solid dielectric between a pair of electrodes in a vacuum, where the dielectric is a model of an insulating spacer holding electrodes in various vacuum devices. Such gap configuration is typical as a model for studying physical mechanisms of an electrical breakdown or a flashover in a vacuum, in which the insulation ability is
considerably lower than a gap without any insulating spacers. Many researchers have long investigated the mechanisms of flashover, and it is believed that the charging of the insulator surface is the primary drive of such weakness. One of the effective approaches for studying mechanisms is to analyze the characteristic of charge accumulated on the insulator surface both by experiments and by
numerical analyses. This paper reviews previous works conducted by the author’s research group and demonstrates the difficulties we have encountered upon conducting the numerical analyses."
AEJ 5:1 (2015)
Artikel Jurnal  Universitas Indonesia Library
cover
James, R.E.
"The book introduces the reader to the major components of a high voltage system and the different insulating materials applied in particular equipments.
During a review of these materials, measurable properties suitable for condition assessment are identified. Analyses are included of some of the insulation fault scenarios that may occur in power equipment.
The basic facilities for carrying out tests on the internal and external insulation structures at high and low voltages are described. Tests and measurements according to specifications, on-site requirements and research investigations are considered.
Advances in the application of digital techniques for detection and analyses of partial discharges are discussed and methods in use, or under development, for service condition monitoring are described. These include the utilization of new sensors, the solution of online problems associated with noise rejection and the adaptation of artificial intelligence techniques for incipient fault diagnosis.
The subject matter of the book is suitable for final year courses in electrical power engineering, short courses in insulation condition assessment and postgraduate programmes. Power system engineers associated with high voltage equipment should find the book of value in relation to fault investigations, maintenance requirements, insulation testing and condition monitoring."
London: Institution of Engineering and Technology, 2008
e20451576
eBooks  Universitas Indonesia Library
cover
Siregar, Muhammad Sutan Gerry
"Skripsi ini dibuat dengan pengkajian dari dua prosedur pengukuran untuk diagnosis sistem isolasi pada generator tegangan tinggi. Pengukuran dapat dibagi menjadi dua bagian, yaitu pengukuran secara online dan offline. pengukuran secara offline terdiri atas resistansi isolator, faktor disipasi, dan peluahan parsial, sedangkan pengukuran secara online hanya terdiri atas peluahan parsial.
IEEE and IEC telah membuat standar yang disebut praktik yang direkomendasikan atau spesifikasi teknis untuk mengukur resistansi isolator, faktor disipasi, dan peluahan parsial dengan menggunakan peralatan diagnostik elektris. Pengukuran secara offline akan dibandingkan dengan pengujian sebelumnya untuk melihat sejauh mana degradasi isolator yang terjadi.
Pengukuran secara online didasarkan pada perubahan beban dan waktu kerja dari mesin tersebut. Parameter ketika mesin bekerja seperti beban, tekanan gas pendingin akan dianalisis untuk melihat bagaimana parameter tersebut mempengaruhi degradasi dari sistem isolasi.
Pengujian secara offline menunjukkan bahwa fasa R memiliki kondisi isolator terburuk, fasa S memiliki penurunan kualitas isolator yang paling signifikan dan, fasa T memiliki kualitas dan stabilitas nilai isolator bila dibandingkan dengan fasa lainnya.
Selain itu, pengujian peluahan parsial menunjukkan telah terjadi delaminasi tape layer pada ketiga fasa yang diakibatkan adanya perubahan nilai vibrasi yang signifikan selama pengoperasian mesin. Pengujian secara online menunjukkan bahwa fasa S memiliki perubahan arus dan daya disipasi yang paling besar dibandingkan fasa lainnya seiring bertambahnya waktu pengoperasian dan meningkatnya pembebanan.

This work is based on the study of two different measurements procedures for the diagnosis of insulation systems of high voltage generators. The measurement can be conducted into two ways, offline or online measurement. The offline measurements consist of Insulation Resistance, Partial Discharge, and Dissipation Factor measurement, meanwhile online measurements consist only partial discharge measurement. The measurements were done in stator windings not only to check the quality but also for the investigation of changes in operating processes.
IEEE and IEC have created standards called recommended practices or technical specifications to address polarization index, dissipation factor, and offline online PD measurement using electrical diagnostic equipment. The offline measurement will be comparated with previous measurement to see how degradation takes place.
The online measurement will be based on on load variable and machine rsquo s working hour. Also, the online parameter such as load, vibration, coolers pressure, and temperature will be analysed to see how it can affect the degradation of the insulation system.
The result of offline measurements show that phase R has the worst condition, phase S has the most significant deterioration, and phase T has the best condition and stability in deterioration.
In addition, partial discharge measurement indicates that the insulation has been undergoing delamination of the tape layer due to significant changes in vibration values during the operation of the machine. The result of online measurements show phase S has the most significant changes in current and power dissipation compared to other phases due to increment of operation time and load.
"
Depok: Fakultas Teknik Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
I Made Yulistya Negara
Yogyakarta: Graha Ilmu, 2013
621.3 IMA t
Buku Teks SO  Universitas Indonesia Library
cover
Artono Arismunandar
Jakarta: Pradnya Paramita, 1978
621 ART t
Buku Teks SO  Universitas Indonesia Library
cover
Artono Arismunandar
Jakarta: Pradnya Paramita, 1984
621 ART t
Buku Teks SO  Universitas Indonesia Library
cover
Tavner, Peter
"Condition monitoring of engineering plants has increased in importance as engineering processes are automated and manpower is reduced. However, electrical machinery receives attention only at infrequent intervals when plant is shut down and the application of protective relays to machines has also reduced operator surveillance.
A first edition of Condition Monitoring of Electrical Machines, written by Tavner and Penman, was published in 1987. The economics of industry have now changed, as a result of the privatisation and deregulation of the energy industry, placing emphasis on the importance of reliable operation of plant, throughout the whole life cycle, regardless of first cost.
The availability of advanced electronics and software in powerful instrumentation, computers, and digital signal processors (DSP) has simplified our ability to instrument and analyse machinery. As a result condition monitoring is now being applied to a wider range of systems from fault-tolerant drives of a few hundred watts in the aerospace industry, to machinery of a few hundred megawatts in major capital plant.
In this new book the original authors have been joined by Ran, an expert in power electronics and control, and Sedding, an expert in the monitoring of electrical insulation systems. Together the authors have revised and expanded the earlier book, merging their own experience with that of machine analysts to bring it up to date."
London: Institution of Engineering and Technology, 2008
e20451581
eBooks  Universitas Indonesia Library
cover
Naidu, Motukuru S.
New Delhi: Tata McGraw-Hill, 2000
621.31 NAI h
Buku Teks SO  Universitas Indonesia Library
cover
London: Peter Peregrinus, 1996
621.319 1 HIG
Buku Teks SO  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>