Ditemukan 35139 dokumen yang sesuai dengan query
New York: Springer-Verlag, 1994
515.785 REP
Buku Teks Universitas Indonesia Library
Chirikjian, Gregory S.
"The emphasis in both of these volumes is on the use of stochastic, geometric, and group-theoretic concepts in the modeling of physical phenomena. Volume 2 builds on the fundamentals presented in Volume 1, delving deeper into relationships among stochastic geometry, geometric aspects of the theory of communications and coding, multivariate statistical analysis, and error propagation on Lie groups. Extensive exercises, motivating examples, and real-world applications make the work suitable as a textbook for use in courses that emphasize applied stochastic processes or differential geometry."
New York: [Springer Science, ], 2012
e20419587
eBooks Universitas Indonesia Library
Folland, Gerald B.
Boca Raton: CRC Press, 1995
515.243 3 FOL c
Buku Teks SO Universitas Indonesia Library
Hewitt, Edwin
Berlin: Springer-Verlag, 1970
R 515.2433 HEW a II
Buku Referensi Universitas Indonesia Library
Martin, Stuart
New York: University of Cambridge, 1993
512.55 MAR s
Buku Teks SO Universitas Indonesia Library
Szekelyhidi, Laszlo
"This book provides a modern introduction to harmonic analysis and synthesis on topological groups. It serves as a guide to the abstract theory of Fourier transformation. For the first time, it presents a detailed account of the theory of classical harmonic analysis together with the recent developments in spectral analysis and synthesis."
New Jersey: World Scientific, 2014
515.243 3 SZE h
Buku Teks SO Universitas Indonesia Library
Berlin: Springer-Verlag, 1993
R 512.55 LIE
Buku Referensi Universitas Indonesia Library
Belinfante, Johan G.F.
"Introduces the concepts and methods of the Lie theory in a form accessible to the non-specialist by keeping mathematical prerequisites to a minimum. Although the authors have concentrated on presenting results while omitting most of the proofs, they have compensated for these omissions by including many references to the original literature. Their treatment is directed toward the reader seeking a broad view of the subject rather than elaborate information about technical details. Illustrations of various points of the Lie theory itself are found throughout the book in material on applications.
In this reprint edition, the authors have resisted the temptation of including additional topics. Except for correcting a few minor misprints, the character of the book, especially its focus on classical representation theory and its computational aspects, has not been changed."
Philadelphia : Society for Industrial and Applied Mathematics, 1989
e20442704
eBooks Universitas Indonesia Library
"This book presents group representation theory at a level accessible to advanced undergraduate students and beginning graduate students. It can also be used as a reference for academics working in all areas of mathematics and statistics"
New York: [Springer, ], 2012
e20419158
eBooks Universitas Indonesia Library
"[Kereta Rel Listrik (KRL) disuplai tegangan 1500 V DC oleh gardu traksi yang didalamnya terdapat komponen penyearah. Penyearah ini memproduksi harmonisa yang menyuntikkan arus menuju sumber tegangan menengah 20kV PLN dan dapat menyebabkan rusaknya peralatan listrik. Hasil pengukuran distorsi harmonisa pada kubikel 20kV/1.2kV gardu traksi menunjukkan THD maksimum tegangan sebesar 1.87 % dan THD arus maksimum sebesar 63.38 %. THD maksimum tegangan masih dibawah standar IEEE (<5%) sedangkan THD maksimum arus berada diatas standar IEEE (<20%). Untuk mengurangi efek distorsi harmonisa arus, dirancang filter pasif untuk memfilter harmonisa orde ke-5,ke-7, dan ke-11. Hasil simulasi dengan ETAP 7.0.0 didapatkan hasil rancangan filter pasif optimum dapat mengurangi THD arus hingga rata-rata 6.24%., Electric train is supplied with 1500 V DC by traction substation which have components of the rectifier . This rectifier produces harmonics that inject harmonics current toward source 20kV PLN and cause the damage of electric utility. Measurement results of harmonic distortion at 20kV/1.2kV cubicles in traction substation shows that the maximum value of THD-v is 1.87% and the maximum value of THD-i is 63.38 %. THD-v is below IEEE standard (< 5 %) and THD-i is above the IEEE standard (<20 %). In order to reduce the effects of harmonics currents, passive filter is designed to filter harmonics for 5th , 7th , and 11th order. ETAP 7.0.0 simulation result obtains the optimum design of passive filter that can reduce THD-i to 6.24% average.]"
Fakultas Teknik Universitas Indonesia, 2014
S57222
UI - Skripsi Membership Universitas Indonesia Library