Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 152781 dokumen yang sesuai dengan query
cover
cover
Fakultas Teknik Universitas Indonesia, 1998
TA2280
UI - Tugas Akhir  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1995
S34550
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1998
TA2245
UI - Tugas Akhir  Universitas Indonesia Library
cover
cover
Joice Katharina S.
"ABSTRAK
Suatu pembangkit energi listrik dituntut memiliki efisiensi yang baik karena terkait erat dengan baik-buruknya pemanfaatan energi panas dari bahan bakar utama.
Pembangkitan energi listrik di sebuah PLTU merupakan rangkaian proses konversi energi dan berlangsung di beberapa peralatan utama pembangkit. Konversi energi kimia batubara menjadi energi panas yang diserap oleh uap berlangsung di dalam boiler, konversi energi uap menjadi energi mekanik berlangsung di turbin dan konversi energi mekanik menjadi energi listrik berlangsung di generator.
Pembangkitan energi listrik di PLTU Suralaya Unit 3 terdiri dari beberapa proses konversi energi dan berlangsung di beberapa peralatan utama pembangkit. Perhitungan efisiensi dilakukan dengan memperhatikan besarnya pemanfaatan energi panas untuk membangkitkan uap di boiler dan pemanfaatan energi uap yang bertemperatur dan bertekanan tinggi untuk memutar turbin dan rotor generator untuk menghasilkan energi listrik. Sehingga dalam perhitungan efisiensi dilakukan perhitungan efisiensi boiler dan efisiensi turbin. Selain itu, jumlah panas yang dilepaskan uap bekas (exhaust steam) di dalam kondensor juga dihitung untuk mengetahui persentase pemanfaatan panas pada pembangkitan.
Perhitungan efisiensi dilakukan menggunakan rumus-rumus serta kurva-kurva yang biasa digunakan untuk menghitung efisiensi di PLTU Suralaya Unit 3.
Dari hasil perhitungan diperoleh efisiensi PLTU Suralaya Unit 3 sebesar 37,13 % dan rugi-rugi sebesar 62,87 % dengan perincian di boiler 14 %, di turbin 0,72 %, listrik pemakaian sendiri 2,13 % dan panas buang (heat reject) di kondensor 46,02 %. Berdasarkan basil perhitungan tersebut, disimpulkan PLTU Suralaya Unit 3 merupakan unit pembangkit yang memiliki efisiensi yang baik.

"
2000
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Victor Firman
"ABSTRAK
Energi Iistrik dewasa ini sudah merupakan kebutuhan primer bagi kehidupan manusia. Baik untuk kehidupan sehari-hari maupun indusin membutuhkan listrik sebagai sumber energi. Untuk mendapatkan energi listrik ini dibuatlah suatu sistem penggerak mula yang dapat mengubah energi potensial yang terdapat pada air menjadi energi Iistnk yang langsung dapat digunakan. Pada sistem tersebut air merupakan fiuida kerianya yang wujudnya diubah-ubah.
Sistem penggerak mula tersebut terdiri dari unit-unit pembangkit uap (boiler), pemanas Ianjut uap (super heater), turbin uap (steam turbine), generator and kondensor. Air pertama kali masuk dari bak penampung dipompakan ke dalam boiler untuk dipanaskan and berubah menjadi bentuk uap. Uap ini kemudian dialirkan ke dalam super heater and keluar sebagai uap super panas. Uap super panes ini kemudian masuk ke dalam turbin uap melalui nosel and menumbuk sudu-sudu turbin sehingga berputaran pada keoepatan tertentu. Sudu-sudu turbin yang berpegangan pada poros yang dikopel dengan generator menyebabkan generator bekerja mengubah energi putaran menjadi energi Iisirik. Kemudian uap bekas tadi dialirkan masuk ke dalam kondensor and dikondensasikan sehingga wujudnya kembaii menjadi cair and siap dioperasikan lagi.
Sistem penggerak mura yang diujikan merupakan miniatur dari sistem penggerak mula yang biasanya digunakan. Pengujian yang dilakukan merupakan pengukuran unjuk kerja unit-unit yang terdapat dalam sistem tersebut juga pengukuran keseluruhan sistem. Analisanya merupakan hasil perhitungan unjuk kerja and perbandingan unjuk kerja yang ditunjukkan pada putaran 3000 rpm and 3600 rpm, dimana putaran 3600 rpm mempakan putaran makslmum dari turbin.

"
2000
S37207
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rika Raniya
"ABSTRAK
Polutan utama dari sistem pembakaran batubara salah satunya SO2. Sulfur dioksidia menyebabkan iritasi, batuk refleks, menyebabkan penyakit pernafasan dan gangguan daya tahan paru-paru. Penelitian ini bertujuan menganalisis pajanan SO2 di lingkungan sekitar pembangkit listrik tenaga uap (PLTU) Suralaya yaitu pada desa Lebak Gede, Cipala Dua, Brigil, Gunung Gede, Salira Indah, dan Sumuranja dan gangguan pernafasannya pada masyarakat sekitar. Penelitian ini bersifat deskriptif, dengan pendekatan cross sectional. Sampel responden diambil secara purposive sampling berdasarkan titik pengukuran udara pada setiap desa yaitu 35 orang di setiap desa. Penelitian ini dilakukan dengan metode Analisis Risiko Kesehatan Lingkungan (ARKL) yang menggunakan nilai Rfc SO2 (0,026 mg / kg / hari), dan selanjutnya dilakukan secara cross sectional untuk menghubungkan tingkat risiko dengan kejadian gangguan pernafasan di sekitar PLTU. Hasil ARKL menunjukkan bahwa tingkat risiko di lingkungan sekitar PLTU Suralaya yaitu pada desa Lebak Gede, Cipala Dua, Brigil, Gunung Gede, Salira Indah, dan Sumuranja masih tergolong aman karena nilai RQ dibawah 1 dalam kurun waktu lebih dari 30 tahun. Hasil analisis cross sectional menunjukkan bahwa tidak ada hubungan antara tingkat risiko kesehatan akibat pajanan SO2 dengan kejadian gangguan saluran pernafasan pada masyarakat di sekitar PLTU karena memiliki nilai-p yang lebih besar dari alfa.
ABSTRACT
One of the main pollutants from the coal combustion system is SO2. Sulfur dioxidia causes irritation, reflex coughing, causes respiratory disease and lung resistance. This study aims to analyze SO2 exposure in the environment around the Suralaya steam power plant (PLTU), namely in the villages of Lebak Gede, Cipala Dua, Brigil, Gunung Gede, Salira Indah, and Sumuranja and respiratory problems in the surrounding community. This research is descriptive, with a cross sectional approach. The sample of respondents was taken by purposive sampling based on air measurement points in each village, namely 35 people in each village. This research was conducted using the Environmental Health Risk Analysis (ARKL) method using the Rfc SO2 value (0.026 mg / kg / day), and then carried out cross-sectional to link the risk level with the incidence of respiratory problems around the PLTU. The ARKL results show that the level of risk in the environment around PLTU Suralaya, namely in the villages of Lebak Gede, Cipala Dua, Brigil, Gunung Gede, Salira Indah, and Sumuranja is still relatively safe because the RQ value is below 1 in a period of more than 30 years. The results of the cross sectional analysis show that there is no relationship between the level of health risk due to SO2 exposure and the incidence of respiratory problems in the community around the PLTU because it has a p-value greater than alpha."
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Niko Lastarda
"Dalam melayani sebuah sistem kelistrikan dibutuhkan pembangkit yang handal dan efisien. Pembangkit Listrik Tenaga Gas Uap PLTGU merupakan salah satu pilihan pembangkit thermal yang mempunyai kriteria tersebut. Terdapat beberapa jenis konfigurasi PLTGU. Khusus untuk PLTGU dengan dua turbin gas memliki dua jenis konfigurasi, yaitu konfigurasi 2G-2H-3S dua turbin gas, dua HRSG, tiga turbin uap dan konfigurasi 2G-2H-1S dua turbin gas, dua HRSG, satu turbine uap . Mode operasi dari setiap jenis konfigurasi menghasilkan keandalan dan efisiensi yang berbeda.
Penelitian ini bertujuan untuk menghitung efisiensi dan keandalan dari dua jenis konfigurasi PLTGU yang menggunakan dua turbin gas, sehingga dapat menentukan pengaruh jenis konfigurasi terhadap efisiensi dan keandalan PLTGU. Dengan menggunakan metode energi input ouput untuk menentukan besar efisiensi dan dengan menghitung Equivalent Availability Factor EAF untuk mendapatkan faktor kesiapan atau keandalan pembangkit.
Dari hasil perhitungan didapatkan konfigurasi 2G-2H-1S memliki nilai efisiensi yang lebih tinggi dari konfigurasi 2G-2H-3S, terhitung Untuk mode operasi Full Blok Cycle konfigurasi 2G-2H-1S memliki efisiensi maksimum 55.5 sedangkan konfigurasi 2G-2H-3S efisiensi maksimum 53.5 . Sedangkan untuk nilai keandalan konfigurasi 2G-2H-3S lebih handal dibandingkan dengan konfigurasi 2G-2H-1S. Untuk mode operasi Full Blok Cycle memliki 93.39 EAF, sedangkan konfigurasi 2G-2H-3S 92.62 EAF. Dari segi keekonomian kedua jenis konfigurasi memiliki nilai kelayakan, dimana untuk konfigurasi 2G-2H-1S lebih ekonomis dilihat dari NPV 371,286,536 USD dan IRR 12 serta waktu pengembalian modal yang relative lebih cepat 9 tahun. Dengan mengetahui konfigurasi PLTGU yang handal, efisien dan ekonomis dapat dijadikan dasar pengambilan keputusan untuk pemilihan konfigurasi PLTGU yang sesuai dengan kebutuhan beban dasar, beban menengah, atau beban puncak di sebuah sistem kelistrikan.Kata Kunci : EAF, Efisiensi, Keandalan, Konfigurasi PLTGU, PLTGU.

In serving the electrical systems required a reliable and efficient plants. Combined Cycle Power Plant CCPP is one of the thermal power plants that have a selection criteria. There are several types of CCPP configurations. Especially for CCPP with two gas turbines have two types of configurations, the configuration of 2G 2H 3S two gas turbines, two HRSG, three steam turbines and the configuration of 2G 2H 1S two gas turbines, two HRSG, one steam turbine , The mode of operation of each type of configuration produces a different reliability and efficiency.
This study aimed to quantify the efficiency and reliability of two types of power plant configuration that uses two gas turbines, so as to determine the effect of this type of configuration on the efficiency and reliability of the CCPP. By using the input energy ouput to determine the efficiency and to calculate Equivalent Availability Factor EAF to obtain readiness factors or reliability of the power plant. From the results of the calculation.
Calculation resulting from the configuration of 2G 2H 1S has a higher efficiency values of configuration 2G 2H 3S, accounting for full block cycle operating modes configuration 2G 2H 1S discount maximum efficiency of 55.5 , while the configuration of 2G 2H 3S efficiency a maximum of 53.5 . As for the value of reliability configuration 2G 2H 3S is more reliable than the configuration of 2G 2H 1S. For full block cycle operating modes discount EAF 93.39 , while the configuration 2G 2H 3S 92.62 EAF. In terms of economics both types of configurations have a feasibility value, which for configuration 2G 2H 1S more economical views of NPV 371,286,536 USD and IRR 12 and the payback time is 9 years faster. By knowing the configuration of a reliable, efficient and economical power plant can be used as a basis for a decision on the selection of CCPP configurations in accordance with based load, medium load, or peak load requirements in an electrical system.
"
Depok: Fakultas Teknik Universitas Indonesia, 2017
T48049
UI - Tesis Membership  Universitas Indonesia Library