Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 1699 dokumen yang sesuai dengan query
cover
"Replacement of autoclave Me-24 temperature controller. Autoclave Me-24 which is used as a passivity equipment of metal in order it rate of corrosion has four haeting systems including their temperature controllers. Replacement of the temperature controllers are inevitable implemented because the controllers is impossible because of both expiry in component and module level of the controllers. Therefor replacement with similar type and performance has to be implemented. This paper describes technical consideration, step design and results of test measurement in the controller repalcement, so that the autoclave can work normally as before."
Artikel Jurnal  Universitas Indonesia Library
cover
URANIA 14 (1-4) 2008 (1)
Artikel Jurnal  Universitas Indonesia Library
cover
Muhammad Vadhel Akbariza
"Dalam penelitian ini dilakukan simulasi pengendalian temperatur dan level air (multivariable) pada proses pencampuran dalam suatu tangki berkapasitas 80 liter menggunakan MATLAB Simulink. Tujuan dari penelitian ini adalah menjaga temperatur dan level air di set point pada sebuah proses dengan mengendalikan debit air dingin dan panas yang masuk ke tangki pencampuran. Keterkaitan antara satu variabel dengan variabel lainnya dapat direduksi menggunakan decoupling. Sistem akan diuji dengan banyak perubahan set point dan diberikan input gangguan berupa ketidakakuratan temperature transmitter dalam membaca temperatur air campuran. Pengujian sistem dilakukan menggunakan pengendali PI dan ANFIS. Pengendali PI digunakan sebagai data training ANFIS. Pada penelitian ini diberikan batasan bahwa debit maksimal yang digunakan adalah 15 l/min, temperatur maksimum pada tangki campuran adalah 90℃, dan level air maksimum tangki adalah 75 cm. Performa dari kedua pengendali akan dibandingkan dengan melihat parameter-parameter seperti RMSE, rise time, settling time, dan %Overshoot sebagai data kualitatif. Penelitian ini menunjukkan bahwa pengendali ANFIS secara keseluruhan lebih baik daripada pengendali PI dalam pengujian perubahan set point yang dapat dilihat dari nilai RMSE ANFIS untuk kendali temperatur berada di angka rata-rata 0.174 dan level pada angka 0.196. RMSE pengendali PI untuk kendali temperatur adalah 0.21 dan level 0.2. Pemberian input gangguan menunjukkan pengendali ANFIS lebih baik daripada pengendali PI dalam menangani adanya kesalahan pembacaan sensor oleh temperature transmitter.

In this research, a simulation program for temperature and level control on a liquid (water) mixing process with assumed to have a tank volume 80 liter is proposed using MATLAB Simulink. The purpose of this study is to maintain the temperature and water level at the set point in a process by controlling the flowrate of cold and hot water that enters the mixing tank. The influence of one variable with others can be reduced using decoupling technique. The system will be tested with many set point changes and given input an inaccurate transmitter temperature in reading the temperature of the mixed water. System testing is performed using a PI and ANFIS Controller. PI Controller is used to generate the ANFIS training data. In this research, a limit is given that the maximum discharge used is 15 liters/min, the maximum temperature and level in the mixed tank is 90℃ and 75 cm. The performance of those two controllers will be compared by observing parameters such as RMSE, rise time, settling time, and %Overshoot as qualitative data. This research shows that ANFIS controllers are generally better than PI controllers when tested with set point changes which can be seen from the ANFIS RMSE values ​​for temperature control at an average rate of 0.174 and a level of 0.196. The RMSE of the PI controller for temperature control is 0.21 and level 0.2. Tests with disturbance input show that ANFIS controllers are better at handling inaccurate transmitter temperature in reading the temperature of the mixed water than PI Controller."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1998
S39545
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Growth response of five clonal cultues of alexandrium obtained from tropical and temperate waters were examined experiments were carried out in eighteen variable temperature-salinity conditions (temperatures of 15 oC,-20oC and 25oC;salinities between 5 to 30 psu) under constant illumination of 150 kurang lebih10.0 umol m2s1 at 15:9 light:dark photo-cycle...."
Artikel Jurnal  Universitas Indonesia Library
cover
Ratu Mahdiyah Nabilah
"Latar belakang: Hidroksiapatit merupakan salah satu bahan alloplast yang banyak digunakan di bidang kedokteran gigi. Komposisi hidroksiapatit sama dengan komposisi anorganik tulang dan gigi manusia sehingga bersifat biokompatibel dan bioaktif. Selain itu, hidroksiapatit juga bersifat osteokonduktif. Salah satu metode pembuatan hidroksiapatit yaitu metode disolusi-presipitasi dalam kondisi hidrotermal. Pembuatan blok hidroksiapatit dengan metode disolusi-presipitasi pada suhu 100°C selama 48 jam masih menghasilkan fasa lain selain hidroksiapatit, yaitu dicalcium phosphate anhydrous (DCPA). Fasa DCPA dan/atau fasa DCPD (dicalcium phosphate dehydrate) dapat terbentuk dalam pH asam. Sedangkan, hidroksiapatit dapat terbentuk pada pH basa. Oleh karena itu, pH dapat dijadikan indikator secara tidak langsung mengenai hasil fasa yang terbentuk. Gipsum dipilih sebagai prekursor karena mengandung ion kalsium (Ca2+). Sedangkan, larutan Na3PO4 digunakan karena mengandung ion fosfat (PO43-), bersifat tidak toksik, dan memiliki pH basa.
Tujuan: Penelitian ini bertujuan untuk mengetahui pengaruh perbedaan suhu terhadap perubahan pH larutan Na3PO4 dalam pembuatan blok hidroksiapatit dari blok gipsum.
Metode Penelitian: Penelitian ini menggunakan blok gipsum dan larutan Na3PO4 sebagai prekursor untuk membuat blok hidroksiapatit. Spesimen yang digunakan berupa 30 mL larutan 1 mol/L Na3PO4 sebanyak dua beaker glass larutan. Sebelum dilakukan perendaman, pH larutan diukur terlebih dahulu untuk mengetahui pH awal larutan 1 mol/L Na3PO4. Lima belas blok gipsum direndam dalam 30 mL larutan 1 mol/L Na3PO4 dengan suhu yang berbeda yaitu 100°C, 140°C, dan 180°C pada kondisi hidrotermal selama 48 jam. Setelah perendaman, blok dan larutan 1 mol/L Na3PO4 dipisahkan. Kemudian, pH larutan 1 mol/L Na3PO4 diukur kembali menggunakan pH meter Eutech Instruments pH 700 untuk mendapatkan pH larutan 1 mol/L Na3PO4 setelah digunakan untuk perendaman selama 48 jam.
Hasil: Nilai pH larutan 1 mol/L Na3PO4 sebelum digunakan untuk perendaman yaitu 13,04. Sedangkan, nilai pH larutan 1 mol/L Na3PO4 setelah digunakan untuk perendaman pada suhu 100°C, 140°C, dan 180°C berturut-turut yaitu 12,72; 12,67; dan 12,30.
Kesimpulan: Peningkatan suhu yang digunakan menyebabkan penurunan pH larutan 1 mol/L Na3PO4. Namun, pH akhir larutan masih cukup basa untuk hidroksiapatit terbentuk. Namun, penelitian lebih lanjut masih perlu dilakukan mengenai pengukuran pH larutan Na3PO4 dengan sampel yang lebih banyak.

Background: Hydroxyapatite is one of the alloplastic materials that is widely used in dentistry. The composition of hydroxyapatite is similar with the inorganic composition of human bone so that it is biocompatible and bioactive. Besides, hydroxyapatite is also osteoconductive. One of the fabrication methods of hydroxyapatite is the dissolution-precipitation method under hydrothermal conditions. The fabrication of hydroxyapatite block with the dissolution-precipitation method at 100°C for 48 hours still produced other phase except hydroxyapatite, specifically dicalcium phosphate anhydrous (DCPA). DCPA and/or dicalcium phosphate dehydrate (DCPD) phase can be obtained if the pH is acidic. Meanwhile, hydroxyapatite can be fabricated on the alkaline pH condition. Therefore, the pH value can be the indirect indicator to predict the phase product. Gypsum was chosen as a precursor because it has calcium ions (Ca2+). Na3PO4 solution was used because it contained phosphate ions (PO43+), non-toxic, and has an alkaline pH value.
Objective: This study aimed to determine the effect of temperature differences on changes of the pH value of Na3PO4 solution in the fabrication of hydroxyapatite block from gypsum block.
Methods: This study used gypsum block and Na3PO4 solution as precursors to fabricate hydroxyapatite block. The specimens of this study were two beaker glasses of 30 mL of 1 mol/L Na3PO4 solution. Before the immersion, the pH value of the solution was measured first to determine the initial pH value of 1 mol/L Na3PO4 solution. Fifteen specimens of gypsum blocks were immersed in 30 mL of 1 mol/L Na3PO4 solution with different temperatures specifically 100°C, 140°C, and 180°C under the hydrothermal condition for 48 hours. After the immersion, the blocks and the 1 mol/L Na3PO4 solution were separated. Then, the pH value of 1 mol/L Na3PO4 solution was measured using Eutech Instruments pH 700 pH meter to obtain the pH of 1 mol/L Na3PO4 solution after being used for immersion for 48 hours.
Results: The pH value of 1 mol/L Na3PO4 solution before being used for the immersion was 13,04. Meanwhile, the pH value of 1 mol/L Na3PO4 solution after being used for the immersion at 100°C, 140°C, and 180°C respectively were 12.72, 12.67, and 12.30.
Conclusions: The increase in the temperature caused the derivation of the pH value of 1 mol/L Na3PO4 solution. Nevertheless, the final pH value was still alkaline enough for hydroxyapatite to be formed. However, further research still needs to be done to measure the pH value of the Na3PO4 solution with more samples.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Herman
"ABSTRAK
Dalam skripsi ini akan dirancang suatu pengendali jaringan syaraf yang dapat bekerja secara on-line yang hanya membutuhkan waktu relatif singkat untuk belajar dari data sebelumnya dan Iangsung menerapkan keluarannya pada kapal laut. Karena sifatnya yang on-line, pengendali jaringan syaraf ini membutuhkan pengetahuan yang mendekati fungsi alih plant yang sebenarnya beserta pengetahuan kualitatif dari sistem yang dikendalikan.
Pengendali jaringan syaraf ini menggunakan arsitektur specialized learningt41 untuk pembelajarannya, sedangkan algoritma yang digunakan untuk proses pembelajarannya adalah back propagation algorithm dengan metoda gradient descent dan penambahan momentum term.t41
Pengendali jaringan syaraf yang dirancang akan diuji dan disimulasikan pada empat jenis lintasan kapal laut yakni lintasan lurus, lintasan zig-zag, lintasan sinusoida dan lintasan berthing yang biasanya digunakan untuk berlabuh. Untuk menambah realitas simulasi dan sekaligus menguji unjuk kerja dari pengendali jaringan syaraf, pada simulasi ditambahkan gangguan-gangguan yang berupa non-linieritas daun kemudi kapal, derau (noise) dan angin.

"
2000
S39720
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yusuf Abdurrakhman Saleh
"Kombinasi antara sensor temperatur DS18B20 Waterproof dengan Arduino telah sering dimanfaatkan sebagai sistem data acquisition DAQ pada pengukuran temperatur karena penggunaannya yang mudah dan harga perangkat yang relatif murah. Arduino dapat menjadi perangkat data acquisition yang valid jika sensor yang digunakan terkalibrasi dengan baik.
Pada penelitian ini, diusulkan metode kalibrasi sensor suhu DS18H20 Waterproof berbasiskan Arduino Uno menggunakan kalibrator Termometer ASTM 117C yang dapat ditelusur nilai kalibrasinya menggunakan media kalibrasi Oli di bejana terbuka. Pemilihan media oli bertujuan untuk mengurangi ketidakstabilan kondisi media sehingga kalibrasi dapat dilakukan.
Sensor DS18B20 Waterproof yang akan dikalibrasi berjumlah 12 sensor disusun sedemikian rupa bersama kalibrator ASTM 117C agar titik-titik pengukuran memiliki kondisi yang sama. Rekayasa yang dilakukan adalah dengan mencari karakteristik penyimpangan temperatur media kalibrasi oli yang terukur pada sensor DS18B20 Waterproof terhadap termometer air raksa ASTM 117C. Karakteristik penyimpangan berupa persamaan garis yang didapatkan dengan metode regresi linier.
Kalibrasi dilakukan dengan memanfaatkan temperatur lingkungan sebagai energi untuk mengalibrasi sensor. Sebelum proses kalibrasi didapatkan rata-rata error Sedangkan setelah dilakukan kalibrasi dengan metode kalibrasi yang diusulkan, sensor DS18B20 memiliki rata-rata error yang lebih kecil yaitu sehingga didapatkan sensor yang lebih akurat untuk selanjutnya dimanfaatkan untuk pengujian inkubator grashoff yang dikembangkan oleh Universitas Indonesia.

The combination between DS18B20 Waterproof temperature sensor and Arduino has been recently used as a data acquisition DAQ system on a temperature measurement for its easily used property and relatively affordable price. Arduino can be a valid data acquisition device if only the sensor is perfectly calibrated.
This research proposed a calibration method for a temperature sensor DS18H20 Waterproof based on Arduino Uno using a thermometer calibrator ASTM 117C which value could be traced by a calibration medium of oil in an open surface bath. The election of oil as the medium is aimed to reduce its conditional instability so that the calibration could be done.
There are 12 arranged DS18B20 waterproof sensors that will be calibrated alongside the ASTM 117C calibrator so that all the measurement points have the exact identical conditions. The engineering proses done to the system is to look for the small deviation characteristics of the oil temperature measured on the DS18B20 Waterproof sensor to the ASTM 117C mercury thermometer. The small deviation characteristics that presented as a linear equation is obtained by using a linear regression method.
Calibration is done by using the ambient temperature as the energy to calibrate the sensors. The movement of ambient temperature will cause as temperature changing response on the medium oil and resulted a measurement points. DS18B20 waterproof sensors resulted a mean error of before any calibration begun. Meanwhile after the calibration using the proposed method, the DS18B20 sensor has a smaller mean error of , so that obtained a more accurate sensor to be used in testing of Grashof Portable Incubator made by University of Indonesia.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dwi Hartati Izaldi
"Sistem pemantauan rumah kaca yang telah ada sebelumnya mempunyai kemampuan hanya untuk membaca nilai suhu dan kelembaban di dalam rumah kaca. Sistem pemantauan yang dibuat dalam penelitian ini adalah sistem utuh yang dibuat dan dirancang untuk mengawasi suhu dan kelembaban di dalam rumah kaca. Tidak hanya itu, sistem ini juga dibuat untuk pengguna yang memiliki tanaman hidroponik, karena sistem ini juga memantau nilai pH pada cairan yang digunakan sebagai media tanamnya. Suhu, kelembaban, dan nilai pH tersebut dapat dilihat oleh pengguna, dimana mereka cukup mengakses halaman web yang telah disediakan sebagai media penampil hasil sistem.
Sistem ini juga dilengkapi dengan otomatisasi, dimana jika nilai pH pada larutan nutrien hidroponik tidak sesuai dengan kondisi normal yang diinginkan, sistem otomatisasi penyeimbang pH larutan akan aktif. Pada penelitian ini dititikberatkan pada perancangan sistem keseluruhan dari segi perangkat keras. Hasil keakuratan sistem dalam membaca temperatur sebesar 98.38%. Waktu kerja sistem pada satu cycle ke cycle lainnya tidak terdapat standar deviasi, sehingga menyebabkan tidak adanya penambahan waktu delay. Keakuratan sistem otomatisasi penyeimbang keasaman pH larutan tanaman hidroponik sebesar 90.1%.

The existing green house monitoring system has the ability to read and know the temperature and humidity inside of green house. Hydroponic and Green House Monitoring System in this research is a complete sistem which is designed to monitor the temperature and humidity inside of green house. Moreover, this system is also designed for user whose hydroponic plants, because it can monitor the pH value of solution as the hydroponic?s growth media. User can see those values via either their PC or their smartphone that is connected to the Internet. They have to access the webpage which is built as the front-end of the system.
This system is also completed with automation, if the pH value of hydroponic?s nutrient solution in an abnormal condition, there will be pH adjuster. This research will be focused on designing the hardware system. The results of system in monitoring the temperature is 98.38%. Response time system in one cycle to another cycle there has no deviation standard, so there is no delay time adding. The accuracy of automation acidity pH adjuster for nutrient solution hydroponic plants is 90.1%.
"
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59151
UI - Skripsi Membership  Universitas Indonesia Library
cover
New York: John Wiley & Sons, 2000
536.502 87 TEM
Buku Teks SO  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>