"Technology and principles using cone beam computed tomography / Matthew Jacobson -- The nature of ionizing radiation and the risks from maxillofacial cone beam computed tomography / Sanjay M. Mallya and Stuart C. White -- Diagnosis of jaw pathologies using cone beam computed tomography / Sharon Brooks -- Diagnosis of sinus pathologies using cone beam computed tomography / Aaron Miracle and Christian GuÌ?ldner -- Orthodontic and orthognathic planning using cone beam computed tomography / Lucia H.S. Cevidanes, Martin Styner, Beatriz Paniagua, JoaÌ?o Roberto Gonçalves -- Three-dimensional planning in maxillofacial reconstruction of large defects using cone beam computed tomography / Rutger Schepers, Gerry M. Raghoebar, Lars U. Lahoda, Harry Reintsema, Arjan Vissink, and Max J. Witjes -- Implant planning using cone beam computed tomography / David Sarment -- CAD/CAM surgical guidance using cone beam computed tomography / George A. Mandelaris and Alan L. Rosenfeld -- Assessment of the airway and supporting structures using cone beam computed tomography / David D. Hatcher -- Endodontics using cone beam computed tomography / Martin D. Levin -- Periodontal disease using cone beam computer tomography / Bart Vandenbergh"
Ames, Iowa: Wiley Blackwell, 2014
617.522 07 CON (1)
Buku Teks  Universitas Indonesia Library
cover
Maulianti
"Citra Cone Beam CT (CBCT) sangat berperan dalam menentukan keberhasilan verifikasi posisi pasien radioterapi, oleh karena itu jaminan kualitas sistem CBCT sangat diperlukan. Percobaan ini dilakukan dengan menggunakan pesawat Linear accelerator yang dilengkapi dengan CBCT dan CT Simulator GE Bright Speed Edge. Fantom Catphan® 600 dan CBCT Electron DensityTM digunakan untuk menilai kualitas dari citra CBCT dan linearitas CT Number. Sesuai dengan uji kualitas, citra pada CBCT hanya dapat membedakan kontras rendah dan kontras tinggi (udara, jaringan dan tulang).
Hasil uji ketebalan slice menunjukkan nilai yang didapat masih dalam batas toleransi ±0.5 mm. Pada uji kontras rendah bagian supra-slice untuk target kontras 1%, 0.5%, dan 0.3% nilai konstantanya sebesar 3, 2.5, dan 4.5, sedangkan pada bagian sub-slice untuk target kontras jarak 7, 5, dan 3 mm memiliki nilai konstanta 5 mm. Hasil pengujian resolusi tinggi pada CBCT dan CT Simulator adalah 3 lp/cm dan 7 lp/cm. Hasil pengujian uniformitas pada CBCT tidak memenuhi standar dari batas toleransi rata-rata CT Number tepi dan tengah kurang dari 5 HU, dan nilai setiap titik tepi dan tengah ±2 HU.

Cone Beam Computed Tomography (CBCT) image is very important in verification of patient positioning in the treatment couch radiotherapy machine so quality control of the system is required. The experiment was performed using the Linear accelerator with equipped with CBCT and CT simulator GE Bright Speed Edge. Catphan® 600 and CBCT Electron DensityTM phantom was used to evaluate the quality of CBCT and CT Number linearity. According to the image quality test, the CBCT image only be able to distinguish low contrast and high contras for air, tissue and bone.
Quantitavely, the slice thickness was in tolerance limit ±0.5 mm, low contrast with constant value of 3, 2.5, dan 4.5 for supra-slice contrast targets 1%, 0.5%, dan 0.3% whereas sub-slice targets axis lenghts for 3, 5, and 7 mm with constant value of 5 mm, the high resolution appear in 3 lp/cm and 7 lp/cm for CBCT and CT simulator, respectively. On the one hand, CBCT uniformity was out of tolerance limit with average CT number edge and central less than 5 HU, and ±2 HU for the edge and center point.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S45532
UI - Skripsi Membership  Universitas Indonesia Library
cover
Efie Mariyam Nursari
"Latar Belakang: Osteoporosis merupakan penyakit tulang sistemik yang ditandai dengan penurunan massa tulang/densitas radiografik tulang dan kerusakan mikroarsi-tektur jaringan tulang. Berbagai indeks radiomorfometrik telah banyak digunakan untuk mengevaluasi tulang pada kasus osteoporosis radiograf panoramik dua dimensi. Analisis Fraktal Dimensi (FD) juga telah digunakan untuk mengidentifikasi struktur pada radio-graf dental dua dimensi. Penelitian ini dilakukan untuk mengevaluasi hubungan peruba-han densitas radiografik tulang rahang terkait BMD dengan menggunakan modalitas pen-citraan tiga dimensi CBCT, yang diwakili pemeriksaan indeks radiomorfometrik (CTCI, CTMI, CTI-S, CTI-I) dan FD value dengan memperhitungkan faktor-faktor risiko yang berpengaruh pada densitas radiografik tulang rahang di antaranya usia, jenis kelamin, jumlah gigi yang tersisa dan ketinggian tulang mandibula. Tujuan: Mengembangkan me-tode deteksi perubahan densitas radiografik tulang rahang pada kasus-kasus kedokteran gigi dengan pemeriksaan CBCT pada individu yang berisiko untuk mendeteksi osteopo-rosis. Metode: Penelitian ini menggunakan data sekunder berupa 87 data set file DICOM CBCT dari pasien lansia dengan rentang usia 50-79 tahun di Klinik Radiologi Kedokteran Gigi RSKGM FKG UI dan Rumah Sakit Pondok Indah Jakarta. Penilaian indeks radio-morfometrik CTCI, jumlah gigi yang tersisa, ketinggian tulang mandibula dilakukan me-lalui panoramik rekonstruksi CBCT dengan slice thickness 30 mm. Pengukuran indeks radiomorfometrik CTMI, CTI-S, CTI-I dan FD value dilakukan pada potongan koronal mandibula di regio foramen mentale terlihat paling jelas dan jarak mesiodistal terlebar. Penilaian FD dilakukan pada dua Region of Interest (ROI) berbentuk persegi berukuran 3x3 mm pada tulang trabekular dan kortikal. Hasil: Indeks radiomorfometrik CTCI, CTMI, CTI-S, CTI-I menunjukkan hubungan yang bermakna secara statistik (p=0.000) dengan FD value ROI tulang kortikal, sementara ROI tulang trabekular tidak menunjuk-kan hubungan yang bermakna. CTCI menunjukkan perbedaan bermakna dengan faktor risiko ketinggian tulang mandibula (p=0.004). CTMI menunjukkan perbedaan bermakna dengan jumlah gigi yang tersisa (p= 0.027) dan ketinggian tulang mandibula (p=0.010). Sementara FD value pada kedua ROI dan faktor risiko usia, jenis kelamin, jumlah gigi yang tersisa serta ketinggian tulang mandibula tidak menunjukkan hubungan yang ber-makna secara statistik. Kesimpulan: Penelitian ini merupakan penelitian pertama meng-gunakan modalitas CBCT yang membandingkan indeks radiomorfometrik melalui pano-ramik rekonstruksi dan analisis FD pada ROI trabekular dan kortikal. Hasil penelitian menunjukkan bahwa pengukuran FD value pada tulang kortikal lebih dapat diandalkan dibandingkan tulang trabekular untuk mendeteksi perubahan densitas radiografik tulang rahang terkait osteoporosis.

ackground: Osteoporosis is a systemic bone disease characterized by decreased bone mass/radiographic bone density and changes in bone microarchitecture. Various radio-morphometric indices have been widely used to evaluate bone in osteoporosis cases on two-dimensional panoramic radiographs. Fractal Dimension (FD) analysis has also been used to identify structures on two-dimensional dental radiographs. This study was con-ducted to evaluate the relationship of radiographic density changes of the jawbones re-lated to BMD by using a three-dimensional imaging modality CBCT, represented by ra-diomorphometric indices (CTCI, CTMI, CTI-S, CTI-I) and FD value taking into account the risk factors that affect the radiographic density of the jawbone including age, gender, number of remaining teeth and mandibular bone height. Objective: To develop a method for detecting radiographic density changes of the jawbone in dental cases by CBCT ex-amination in individuals at risk for detecting osteoporosis. Methods: This study used sec-ondary data in the form of 87 DICOM CBCT file data sets from elderly patients with an age range of 50-79 years at the RSKGM FKG UI and Pondok Indah Hospital Jakarta. Assessment of the CTCI, number of remaining teeth, and mandibular bone height were performed through CBCT panoramic reconstruction with a slice thickness of 30 mm. The CTMI, CTI-S, CTI-I, and FD values were measured on the coronal section of the mandi-ble in the mental foramen region which was most clearly visible and the widest mesi-odistal distance. FD assessment was carried out in two Regions of Interest (ROI) with a rectangular shape measuring 3x3 mm in trabecular and cortical bone. Results: The radi-omorphometric indices CTCI, CTMI, CTI-S, and CTI-I showed a statistically significant correlation (p=0.000) with the FD value ROI of cortical bone, while the ROI of trabecular bone did not show a significant correlation. CTCI showed a significant difference with risk factors for mandibular bone height (p=0.004). CTMI showed a significant difference in the number of remaining teeth (p=0.027) and mandibular bone height (p=0.010). Mean-while, the FD value for both ROI and risk factors for age, sex, number of remaining teeth, and mandibular bone height did not show a statistically significant correlation. Conclu-sion: This study is the first study using the CBCT modality comparing radiomorphomet-ric indices through panoramic reconstruction and FD analysis on ROI of trabecular and cortical bone. The results showed that measuring the FD value of cortical bone is more reliable than trabecular bone for detecting radiographic density changes of the jawbone associated with osteoporosis"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Rina Fajarwati
"Latar Belakang: Identifikasi jenis kelamin membutuhkan sarana yang terjangkau dengan realibilitas yang baik, terutama pada kondisi jenazah yang terbakar hebat, rusak, atau terdekomposisi. Sinus maksilaris dan kanalis mandibularis merupakan salah satu struktur yang dapat digunakan untuk prakiraan jenis kelamin. Cone Beam Computed Tomography (CBCT) adalah metode non infasif yang dapat memberikan gambaran struktur anatomis maksilofasial termasuk sinus maksilaris dan kanalis mandibularis dengan resolusi yang tinggi, sehingga untuk kepentingan identifikasi forensik dapat memberikan pengukuran dengan akurasi tinggi. Tujuan: Hasil analisis perbedaan ukuran sinus maksilaris dan posisi kanalis mandibularis diharapkan dapat digunakan untuk prakiraan jenis kelamin. Metode: Membandingkan ukuran sinus maksilaris dan posisi kanalis mandibularis antara jenis kelamin menggunakan CBCT.
Hasil: Perbedaan yang bermakna pada ukuran sinus maksilaris, serta jarak dari kanalis mandibularis ke batas inferior mandibula antara laki-laki dan perempuan.
Kesimpulan: Terdapat perbedaan bermakna pada tinggi, panjang, dan lebar sinus maksilaris antara laki-laki dan perempuan, dengan nilai rerata masing-masing laki-laki dan perempuan sebesar 39.4 ± 4.6 dan 33.9 ± 4.8 pada tinggi, 39.9 ± 3.2 dan 37.4 ± 2.4 pada panjang, serta 31.1 ± 4.6 dan 28.6 ± 3.8 pada lebar sinus maksilaris. Terdapat perbedaan bermakna pada jarak dari kanalis mandibularis ke batas inferior mandibula antara laki-laki dan perempuan, dengan nilai rerata pada laki-laki dan perempuan yaitu sebesar 7.7 ± 1.7 dan 6.8 ± 1.5. Berdasarkan ukuran tinggi dan panjang sinus maksilaris, serta jarak dari kanalis mandibularis ke batas inferior mandibula maka didapatkan rumus P = 1/1+e- [-16.613 + (<0.183 x TSM) + (0.204 x PSM) + (0.260 x JIKM)] untuk prakiraan jenis kelamin, dengan nilai ≥ 0.5 pada laki-laki dan < 0.5 pada perempuan.

Background: Gender identification requires a tool which has high reliability, especially in the conditions of the bodies that are severely burned, damaged, or decomposed. The maxillary sinus and mandibular canal are one of the maxillofacial structure that can be used to identify the gender. Cone Beam Computed Tomography (CBCT) is a non-invasive method which can visualize the anatomical of the maxillofacial structure including the maxillary sinus and mandibular canal with high-resolution so that CBCT can provide better measurements for forensic identification.
Aim: The results of the study can show the differences in maxillary sinus size and mandibular canal position which are expected to be used for gender identification.
Methods: Comparing the maxillary sinus size and mandibular canal position between genders using CBCT.
Result: The maxillary sinus sizes and the distance from the mandibular canal to the inferior border of the mandible between men and women were significantly different.
Summary: There were significant differences in the height, length, and width of the maxillary sinus between men and women, with the mean value of men and women, respectively were 39.4 ± 4.6 mm and 33.9 ± 4.8 mm for height, 39.9 ± 3.2 mm and 37.4 ± 2.4 mm for length, and 31.1 ± 4.6 mm and 28.6 ± 3.8 mm for width of the maxillary sinus. There was a significant difference in the distance from the mandibular canal to the inferior border of the mandible between men and women, with a mean value were 7.7 ± 1.7 mm and 6.8 ± 1.5 mm. Based on the height and length of the maxillary sinus, which exclude the width of the maxillary sinus, and the distance from the mandibular canal to the inferior border of the mandible, the formula for gender estimation was P = 1/1+e- [-16.613 + (0.183 x Height of maxillary sinus) + (0.204 x Length of maxillary sinus) + (0.260 x JIKM). The distance from the mandibular canal to the inferior border of the mandible with male values ≥ 0.5 whereas for women when < 0.5.
"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2019
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Novrizki Daryl Rachman
"Teknik Cone Beam Computed Tomography (CBCT) dalam pemindaian 3DRA menggunakan sinar-X berbentuk kerucut bulat atau persegi panjang dengan rotasi pemindaian yang tidak mencapai 360 derajat. Sementara itu, metode perhitungan dosimetri 3DRA saat ini masih mengacu pada konsep CTDI, hal ini mungkin tidak sesuai untuk dosimetri CBCT karena sudut pancaran cone yang lebih besar dibandingkan dengan sudut pancaran fan beam dan rotasi pemindaian 3DRA yang tidak mencapai 360 derajat. Penelitian ini bertujuan untuk menganalisis distribusi dosis pada simulasi dan pengukuran dalam pemindaian Angiografi Rotasi Tiga Dimensi (3DRA). Metode yang digunakan melibatkan perbandingan hasil simulasi distribusi dosis menggunakan perangkat lunak EGSnrc dengan hasil pengukuran pada pesawat Angiografi Phillips Allura FD20 (tiga mode pemindaian) menggunakan bilik ionisasi. Proses simulasi menggunakan perangkat lunak EGSnrc terdiri dari tiga tahap. Pertama, lima fantom CTDI virtual dibuat untuk merepresentasikan lubang sesuai dengan penempatan dosimeter pada posisi yang berbeda (pusat, arah jam 3, 6, 9, dan 12). Ukuran voxel fantom disesuaikan menjadi 1 × 1 × 1 mm². Tahap kedua melibatkan pemodelan dan simulasi tabung sinar-X pada sistem 3DRA menggunakan perangkat lunak BEAMnrc. Terakhir, dilakukan simulasi penyinaran pada fantom virtual menggunakan perangkat lunak DOSXYZnrc. Jumlah histories untuk simulasi ditetapkan menjadi 2.5×108, nilai energi cutoff diatur pada 0,521 MeV untuk transportasi elektron, dan 0,001 MeV untuk transportasi foton. Hasil penelitian menunjukkan bahwa area yang paling banyak terpapar radiasi pada ketiga mode 3DRA terletak pada arah jam 3, 6, dan 9 dari fantom. Nilai akurasi tertinggi didapatkan pada mode Xper CT Cerebral HD pada posisi pengukuran pusat dengan nilai presentase perbandingan sebesar 0,9%, sementara nilai akurasi terendah didapatkan pada mode Xper CT Cerebral LD pada posisi pengukuran arah jam 6 dengan nilai prensentase perbandingan sebesar 647,3%.

Cone Beam Computed Tomography (CBCT) in 3D rotational angiography (3DRA) uses cone-shaped X-ray beams with non-360 degrees rotation. However, current dosimetry calculation methods for 3DRA, which are based on CTDI formalism, may not be suitable due to the larger cone beam angles compared to fan beam angles and the rotation of 3DRA being not a full 360-degree rotation. This study aims to analyze the dose distributions in simulations and direct measurements in 3DRA scans. The method involves comparing the simulation results of dose distributions using EGSnrc software with direct measurements Philips Allura FD20 angiography (in three preset modes) using a head CTDI phantom and an ionization chamber. To analyze the dose distributions in 3DRA, five virtual CTDI phantoms are generated to represent holes corresponding to the placement of dosimeters at different positions (at center, 3, 6, 9, and 12 o'clock). The voxel size of the phantoms is adjusted to 1×1×1 mm². The modeling and simulation of the X-ray tube in the 3DRA system using the BEAMnrc software. The DOSXYZnrc software is used to simulate the irradiation on the virtual phantom. The simulation is performed with 2.5×108 histories, and the energy cutoff value is set at 0.512 MeV for electron transport and 0.001 MeV for photon transport. The results show that the areas most exposed to radiation in all three preset modes of 3DRA are located on the sides and bottom (at 3, 6, and 9 o'clock) of the phantom. The highest accuracy value was obtained in the Xper CT Cerebral HD mode at the center position with a percentage comparison value of 0.9%, while the lowest accuracy value was obtained in the Xper CT Cerebral LD mode at the 6 o'clock position with a percentage comparison value of 647.3%."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Franciska Veyta Ayu
"Latar Belakang: Estimasi usia merupakan salah satu profil penting pada proses identifikasi individu. Selain gigi, skeletal juga merupakan parameter yang dimanfaatkan untuk estimasi usia, termasuk tahap penutupan sutura palatina yang dimulai dan menutup pada usia tertentu. Pemeriksaan penutupan sutura palatina dengan gambar CBCT belum banyak diteliti. Tujuan: Menganalisis apakah morfologi tahap penutupan sutura palatina melalui observasi gambaran CBCT berpotensi digunakan sebagai penanda untuk estimasi usia terutama pada populasi di Indonesia dengan ras Malayan-Mongoloid. Metode: Desain cross sectional pada 150 hasil rekonstruksi radiograf CBCT yang memperlihatkan sutura palatina. Dilakukan penilaian tahap penutupan sutura palatina oleh dua observer untuk kesesuaian inter dan intra observer. Hasil dan Kesimpulan: Analisis CBCT tahap penutupan sutura palatina dapat digunakan sebagai salah satu metode estimasi usia pada populasi Indonesia dengan tidak ada perbedaan bermakna tahap penutupan sutura palatina antara pria dan wanita.

Background: Age estimation is one of major profile in forensic identification process. In addition to teeth, skeletal ossification process is also as age estimation parameter, including palatine suture which its closure in particular age. There are slightly Cone-beam computed tomography studies that assess palatine suture obliteration. Aim: to analyse potential of morphology of palatine suture obliteration process through CBCT image analysis as age estimation parameter particularly in Indonesian population with Malayan-Mongoloid race. Methods: cross-sectional study of 150 CBCT images that showed palatine suture. Obliteration of palatine suture were evaluated for intraexaminer and interexaminer agreements by weighted kappa tests. Result and Conclusion: CBCT analysis of palatine suture obliteration process could be utilized as one of age estimation method in Indonesian population, and no sexual dimorphism in palatine suture obliteration."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Nainggolan, Dessy Lina
"Udara di tulang temporal mempunyai fungsi yang bervariasi, terutama sebagai cadangan udara telinga tengah. Gangguan fungsi tuba Eusthacius akan menyebabkan udara di tulang temporal berfungsi sehingga tidak terbentuk tekanan negatif yang disebabkan penyerapan udara oleh mukosa telinga tengah. Hal ini mencegah terjadinya perubahan mukosa telinga tengah dan mencegah terjadinya otitis media.
Tujuan penelitian ini adalah untuk menilai kesesuaian klasifikasi pneumatisasi mastoid berdasarkan struktur sinus sigmoid terhadap volume akurat sel-sel udara mastoid menggunakan MSCT Scan Spiral di Rumah Sakit Cipto Mangunkusumo berupa 158 mastoid dari 78 pasien (40 laki-laki dan 38 perempuan) dengan rentang umur 18 sampai 60 tahun tanpa kelainan atau malformasi pada gambaran CT Scan. Data sekunder diambil dari raw data yang telah direkonstruksi menggunakan pesawat CT scan Somatom spiral scanner (Siemens Medical Systems) dengan tebal irisan 2,0 mm, Filter Kernel H 70 very sharp, mastoid window (window width 4.000 HU, window level 600 HU), densitas antara – 1.000HU sampai dengan +70HU di dalam Compact Disc.
Klasifikasi pneumatisasi mastoid ditentukan berdasarkan tiga garis paralel dengan kemiringan 45◦ yang diletakkan pada posisi garis melewati bagian paling anterior dari sinus sigmoid pada persimpangannya dengan tulang petrosus, bagian paling lateral di sepanjang bidang transversal sigmoid groove dan paling posterior dari sinus sigmoid.
Statistik deskriptif (SPSS 17.0) disajikan berupa analisis volume sel-sel udara mastoid berdasarkan kelompok pneumatisasi menggunakan uji Kruskal Wallis dilanjutkan analisis Post Hoc dengan hasil rerata volume sel-sel udara masingmasing kelompok pneumatisasi berbeda bermakna dengan kelompok lainnya, dengan batas kemaknaan (α) 0,05, dan ROC (Receiver operator curve) menunjukkan bahwa masing-masing kelompok pneumatisasi mempunyai sensitivitas dan spesifisitas tinggi.

The air in the temporal bone has various functions. In particular, it serves as the air reservoir of the middle ear. When the function of the Eustachian tube deteriorates, the air in the temporal bone acts to prevent negative pressure from developing due to absorption of air by the middle ear mucosa, and thus prevents changes of the middle ear mucosa, as well as progression of otitis media.
The aim of this paper is to evaluate The Conformity Classification of Mastoid Pneumatization in Normal Adult based on Sigmoid Sinus with the Mastoid Air Cells Volume using Spiral MSCT Scan in Cipto Mangunkusumo Hospital of One hundred and fifty six mastoids of 78 subjects (40 males and 38 males) ranged in age from 18 years to 60 years without impairment or malformation of temporal bone CT scan were eligible for enrolment in this study.
Secondary data drawn from raw data in Compact Disc that has been reconstructed using Somatom spiral scanner (Siemens Medical Systems) with 0,2 cm slice thickness, filter Kernel very sharp and mastoid window (window width 4.000HU and window level 600HU). We used -1.000 to + 70 HU.
Classification of mastoid pneumatization is determined based on three parallel lines angled at 45◦ in the anterolateral direction which each line crossed the most anterior point of the sigmoid sinus at the junction with the petrous bone, the most lateral aspect along the transverse plane of the sigmoid groove, and the most posterior point of the sigmoid sinus, respectively.
Descriptive statistics (SPSS 17.0) are presented in the form of air cells mastoid volume based on Classification of mastoid pneumatization using Kruskal Wallis test and followed by Post Hoc analysis with the volume of the mastoid air cells of each group differ significantly with other groups, significance limit of 0.05, and ROC (Receiver operator curve) showed that each group has a high sensitivity and specificity."
2012
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Oxford: Oxford University Press, 2014
R 617.522 ORA
Buku Referensi  Universitas Indonesia Library
cover
Tarigan, Sonak Tioria
"Penelitian ini bertujuan untuk mengevaluasi akurasi perhitungan dosis berdasarkan citra Cone Beam Computed Tomography (CBCT) sebagai adaptive planning. Perencanaan terapi radiasi dilakukan terhadap 3 pasien kanker laring, 7 pasien kanker paru dan 5 pasien kanker prostat dengan menggunakan teknik Intensity Modulated Radiotherapy (IMRT) dan Volumetric Modulated Arc Therapy (VMAT). Perhitungan dosis dilakukan pada TPS Eclipse v13.6 dengan variasi algoritma Analytical Anisotropic Algorithm (AAA) dan Acuros External Beam (AXB).
Penelitian ini diawali dengan tahapan (1) kalibrasi HU citra CBCT menggunakan fantom CIRS 002LFC (2) analisa dose volume histogram (DVH), (3) analisa gamma index dengan kriteria DD 2% / DTA 2mm serta DD 3% / DTA 3mm menggunakan perangkat EPID. Penyimpangan D98%, D50% dan D2% dari DVH dievaluasi dengan menjadikan citra CT algoritma AAA sebagai referensi. Diperoleh nilai penyimpangan D98%, D50% dan D2% tertinggi pada kasus kanker laring yaitu sebesar 9,08% ± 2,21 (CBCT AXBm - CT AAA), 0,74% ± 0,37 (CBCT AXBw - CT AAA) dan 3,79% ± 0,55 (CBCT AXBw - CT AAA).
Penyimpangan D98%, D50% dan D2% pada kasus kanker paru dan kanker prostat diperoleh lebih kecil dari 2%. Conformity index (CI) diperoleh pada rentang 0,98 ± 0,011 dan homogeneity index (HI) diperoleh pada rentang 0,08 ± 0,015. Analisa gamma index dengan kriteria 2%/2mm diperoleh pada range 87% - 94% dan kriteria 3%/3mm diperoleh 93% - 99%. Dari hasil penelitian ini didapati bahwa hasil kalkulasi dosis berdasarkan citra CBCT hampir sama dibandingkan dengan citra FBCT sehingga citra CBCT dilihat layak digunakan sebagai adaptive planning radiotherapy.  

The purpose of this study was to evaluate the accuracy of dose calculation based on Cone Beam Computed Tomography (CBCT) as adaptive planning. Treatment planning was generated for 3 patients larynx, 7 patients lung and 5 patients prostate using Intensity Modulated Radiotherapy (IMRT) and Volumetric Arc Therapy (VMAT). Eclipse v13.6 treatment planning system (TPS) with Analytical Anisotropic Algorithm (AAA) and Acuros External Beam (AXB) algorithm has been used to calculate the dose.
This study was divided into three major parts : (1) HU calibration for CBCT images by using CIRS phantom 002LFC (2) dose volume histogram (DVH) analysis, (3) analysis of Gamma Passing Rate with criteria DD 2% / DTA 2mm and DD 3% / DTA 3mm using EPID. The DVH analysis for D98%, D50% dan D2% deviation was evaluated and CT images with AAA algorithm used as reference. The highest deviation of D98%, D50% dan D2% was found for larynx cancer with value  9,08% ± 2,21 (CBCT AXBm - CT AAA), 0,74% ± 0,37 (CBCT AXBw - CT AAA) and 3,79% ± 0,55 (CBCT AXBw - CT AAA).
Deviation of D98%, D50% dan D2% for lung and prostate cancer is less than 2%. Range of conformity index based on CBCT images is 0,98 ± 0,011 and homogeneity index is in the range of 0,08 ± 0,015. The gamma criteria of dose difference and dose to agreement for 2%/2mm are 87% - 94% and for 3%/3mm are 96% - 98%. From the result, we found that the difference of dose calculation based on CBCT images is almost similar to CT images, so CBCT images are proper to be used for adaptive planning.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
T54121
UI - Tesis Membership  Universitas Indonesia Library
cover
Yudwitiawati
"Uji fungsi CBCT perlu dilakukan untuk memastikan performa terbaik pada CBCT. Uji fungsi yang dilakukan pada penelitian in adalah akurasi isocenter,kualitas citra 3D dan 2D dengan menggunakan fantom Ball bearing, Catphan, dan LEEDS. Uji fungsi dilakukan dengan 2 mode yang berbeda yaitu mode service dan clinical yang memiliki resolusi 540 x 540 dan 270 x 270. Pengukuran dengan menggunakan ball bearing dapat melihat pergeseran isocenter pada sumbu x, y, z. Pergeseran terbesar terjadi pada rotasi 0º sebesar 0.23 cm sumbu x 0.02 cm sumbu z. Hasil perbandingan evaluasi citra 3D pada mode service dan clinical menunjukan bahwa CT number keduanya tidak terlalu banyak perbedaan. Resolusi tinggi pada mode service mencapai 8lp/cm sedangkan pada mode clinical resolusi tidak mampu membedakan sama sekali. Uji citra 2D menggunakan tiga jenis fantom LEEDS. Kontras rendah dapat dilihat dan dievaluasi pada LEEDS TOR 18 FG,TOR CDR,dan TO10. Kontras tinggi hanya dapat dilihat pada LEEDS TOR 18 FG dan TOR CDR. Tidak terdapat perbedaan yang signifikan dari hasil evaluasi kontras rendah dan perbedaan signifikan terjadi pada kontras tinggi.dan uji resolusi antara kedua mode. Fantom NORMI 4 juga digunakan pada penelitian ini, dan tidak ada perbedaan hasil dari uji kontras tinggi dan kontras rendah antara NORMI 4 dan LEEDS. Hasil kontras tinggi dari fantom NORMI 4 adalah 4 lp/mm. Oleh karena itu fantom NORMI 4 dapat dijadikan alternatif lain untuk menilai resolusi dan kontras pada citra 2D. Perhitungan CBDIw dengan fantom CTDI berdiameter 16 cm adalah 8.3 mGy. Uji fungsi sebaiknya menggunakan resolusi tertinggi.

Performence test of Cone Beam Computed Tomography (CBCT) must be done to ensure CBCT is on its best performance. The performance test done in this study are isocenter accuracy, 3D and 2D image quality using ball bearing phantom, CATPHAN, LEEDS test object, and Normi. The test was done using 2 different mode wich are service and clinical mode that has resolution of resolution 540 x 540 and 270 x 270. Ball bearing measurements showed that this technique can detect isocenter shift on the axis of x, y, and z. The largest isocenter displcement occurred at 0 º rotation at 0.23 cm x-axis 0.02 cm z-axis. 3D image comparison using service and clinical mode, show that CT Number value are not much different. High contras resolution at service mode is 8 lp/cm but on clinical mode is not able to distinguish at all. 2D image comparison were done using three types LEEDS test object, low contrast can be observed and evaluated on LEEDS TOR 18 FG, TOR CDR, and TO10, high contrast can be bserved on LEEDS 18 FG and TOR CDR. From LEEDS test object there were no significant difference were shown on low contrast comparison and significant difference were shown on high contrast and resolution test. Normi 4 phantom also used on this study, and there were no difference in trend result on high and low contrast between NORMI 4 phantom and LEEDS test object. Result of NORMI 4 measurement high contrast resolution is 4 lp/mm. Therefore Normi 4 can be used as an alternative to asses the image resolution and contrast in 2D images on CBCT. CBDIw calculations with 16 cm diameter CTDI phantom was 8.3 mGy. Performance tests should use the highest resolution.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S46815
UI - Skripsi Membership  Universitas Indonesia Library