Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 39158 dokumen yang sesuai dengan query
cover
Maria Margaretha Suliyanti
"ABSTRACT
A series of experimental studies on the emission spectra of laser-induced plasma at reduced ambient gas pressure were carried out for the analyses of organic materials. The plasma was generated by means of a Q-switch Nd-YAG laser having a pulse width of 8 ns, wavelength of 1,064 nm and operated at an energy of 120 mJ. The emission was detected with time-integrated and time resolved spectroscopic techniques. These studies were intended to investigate the possible extension of the previously established technique of laser induced shock-wave plasma spectroscopy (LISPS) for its applications to organic samples of different natures as well as to examine the related excitation mechanism and the effects of different experimental conditions on the plasma generation.
The first experiment was conducted on soft solid organic samples or samples which have low melting point. It is well known that plasma emission from soft organic samples can not be directly produced by Nd-YAG laser irradiation even in low pressure surrounding gas. We have shown in this experiment that this problem can be overcome by placing a hard sub-target behind or underneath the soft samples or putting an obstacle in front of it. The sharp emission lines of light elements such as hydrogen, carbon and chlorine from organic samples were clearly observed from a black polyvinyl chloride plastic sheet when the shock wave plasma was generated in appropriately chosen low-pressure of the ambient air.
In the second experiment, the same technique has been successfully applied for hydrogen and carbon atomic emission analysis in various fossil samples at low gas pressure around 3 Torr. The quality of the spectrum allows a quantitative comparison of the carbon and hydrogen emission intensities with the associated molecular band spectra, yielding a rough estimation of the period of fossilization process. In the third experiment, another successful application of this technique was also achieved for spectrochemical analysis of bead samples, which offers the possibility of its applications for non destructive identifications of genuine beads as well as its potential application to other areas of forgery inspection.
In addition to the variety of applications demonstrated in those experiments, the related study has also verified the distinct role of laser induced shockwave in the generation of excitation process leading to the observed favorable plasma emission. We show in this connection the crucial condition of low pressure ambient gas for producing the sharp emission lines desirable for high resolution and quantitative analysis. It was further demonstrated that the mass difference between the host elements and the impurity elements has a sensitive effect on the pressure dependent characteristics of the emission lines to be analyzed.
On the basis of those results, we have reason to hold out hope for the extension of the technique developed in this study to more credible quantitative spectrochemical analysis of organic samples, including those of biomedical interest and those in the form of thin films.
"
2006
D676
UI - Disertasi Membership  Universitas Indonesia Library
cover
Maria Margaretha Suliyanti
"ABSTRACT
A series of experimental studies on the emission spectra of laser-induced plasma at reduced ambient gas pressure were carried out for the analyses of organic materials. The plasma was generated by means of a Q-switch Nd-YAG laser having a pulse width of 8 ns, wavelength of 1,064 nm and operated at an energy of 120 mJ. The emission was detected with time-integrated and time resolved spectroscopic techniques. These studies were intended to investigate the possible extension of the previously established technique of laser induced shock-wave plasma spectroscopy (LISPS) for its applications to organic samples of different natures as well as to examine the related excitation mechanism and the effects of different experimental conditions on the plasma generation.
The first experiment was conducted on soft solid organic samples or samples which have low melting point. It is well known that plasma emission from soft organic samples can not be directly produced by Nd-YAG laser irradiation even in low pressure surrounding gas. We have shown in this experiment that this problem can be overcome by placing a hard sub-target behind or underneath the soft samples or putting an obstacle in front of it. The sharp emission lines of light elements such as hydrogen, carbon and chlorine from organic samples were clearly observed from a black polyvinyl chloride plastic sheet when the shock wave plasma was generated in appropriately chosen low-pressure of the ambient air.
In the second experiment, the same technique has been successfully applied for hydrogen and carbon atomic emission analysis in various fossil samples at low gas pressure around 3 Torr. The quality of the spectrum allows a quantitative comparison of the carbon and hydrogen emission intensities with the associated molecular band spectra, yielding a rough estimation of the period of fossilization process. In the third experiment, another successful application of this technique was also achieved for spectrochemical analysis of bead samples, which offers the possibility of its applications for non destructive identifications of genuine beads as well as its potential application to other areas of forgery inspection.
In addition to the variety of applications demonstrated in those experiments, the related study has also verified the distinct role of laser induced shockwave in the generation of excitation process leading to the observed favorable plasma emission. We show in this connection the crucial condition of low pressure ambient gas for producing the sharp emission lines desirable for high resolution and quantitative analysis. It was further demonstrated that the mass difference between the host elements and the impurity elements has a sensitive effect on the pressure dependent characteristics of the emission lines to be analyzed.
On the basis of those results, we have reason to hold out hope for the extension of the technique developed in this study to more credible quantitative spectrochemical analysis of organic samples, including those of biomedical interest and those in the form of thin films.
"
2006
D1358
UI - Disertasi Membership  Universitas Indonesia Library
cover
Boca Raton: CRC Press, Taylor & Francis Group, 2009
621.366 APP
Buku Teks SO  Universitas Indonesia Library
cover
Affi Nur Hidayah
"Au-Ag nanoalloys disintesis dengan menggunakan tehnik laser radiasi femtosecond dengan metode top-down maupun bottom-up. Metode top-down Au-Ag nanoalloys disintesis dari pelat Au dan Ag sedangkan metode bottom-up disintesis dari garam metal silver nitrate AgNO3 dan garam metal emas Potassium gold III chloride K AuCl4 . Pada metode top-down, pelat Au dan Ag ditembak dengan radiasi laser femtosecond, dihasilkan nanopartikel emas AuNPs dan nanopartikel perak AgNPs dengan waktu abalasi 25 menit dan 1 jam. Kemudian dicampur dengan perbandingan 50:50 dan ditembak laser kembali dengan waktu irradiasi yang berbeda sehingga dihasilkan Au-Ag Nanoalloys dengan ukuran 12-13 nm. Sedangkan pada metode bottom-up, Au-Ag Nanoalloys dibuat dari perbandingan larutan ion Au dan larutan Ag yaitu Au100Ag0 100:0 , Au10Ag90 10:90 , Au80Ag20 80:20 , Au70Ag30 70:30 , Au60Ag40 60:40 , Au50Ag50 50:50 , Au40Ag60 40:60 , Au70Ag30 70:30 , Au80Ag20 80:20 , Au10Ag90 10:90 dan Au100Ag0 100:0 pada medium air, medium air PVP 0,01 dan medium air PVP 0,1 dan setiap komposisi tersebut pada setiap medium ditembak dengan waktu iradiasi laser yang berbeda sehingga dihasilkan Au-Ag Nanoalloys dengan ukuran partikel 5-10 nm. Setelah Au-Ag nanoalloys terbentuk, sifat optiknya dipelajari yaitu pergeseran surface plasmon. Dimana surface plasmon dipengaruhi oleh oleh ukuran nanomaterial, bentuk, komposisi, pengaruh kimia dan lingkungan sekitar nanopartikel.

Au Ag Nanoalloys are synthesized with femtosecond laser technique with top down and bottom up methods. In top down Au Ag Nanoalloys are synthesized from 99 plate Au and Ag, while bottom up method Au Ag Nanoalloys are synthesized from silver nitrate metal salt AgNO3 dan Potassium gold III chloride K AuCl4 . In top down 99 plate Au and Ag were shot laser, respectively until result nanogold AuNPs and nanosilver AgNPs at 25 minutes and 1 hour ablation time and then mix with ratio 50 50, after that was shot laser with different irradiation time until Au Ag Nanoalloys formed with particle size of 12 13 nm. And in bottom up Au Ag Nanoalloys are made from the different ratio ion liquid Au and Ag that is Au100Ag0 100 0 , Au10Ag90 10 90 , Au80Ag20 80 20 , Au70Ag30 70 30 , Au60Ag40 60 40 , Au50Ag50 50 50 , Au40Ag60 40 60 , Au70Ag30 70 30 , Au80Ag20 80 20 , Au10Ag90 10 90 dan Au100Ag0 100 0 in water medium, water medium PVP 0,01 and water medium PVP 0,1 . Each different molar ratio in the different medium was shot with different irradiation time resulting Au Ag Nanoalloys with particle size of 5 10 nm. After Au Ag formed, the optical properties are studied i.e. the shift of surface plasmon. Where surface plasmon is affected by nanoparticle size, shape, composition, chemical and environment around nanoparticle.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
T51577
UI - Tesis Membership  Universitas Indonesia Library
cover
Lin Prasetyani
"ABSTRAK
Pada proses engraving penggunaan laser berdaya tinggi marak digunakan saat ini. Laser daya tinggi yang sering digunakan adalah laser gas seperti CO2, Nd:YaG dan laser diode. Laser diode memiliki beberapa kekurangan diantaranya sudut divergensi lebar, astigmatisme dan beam profile yang tidak ideal yang berbentuk elips. Kekurangan tersebut menyebabkan kualitas beam profile yang buruk. Oleh karena itu perlu dilakukan koreksi beam pada output diode untuk mengurangi rasio elips yang dimilikinya. Metode koreksi yang umum dilakukan adalah dengan menggunakan dua lensa silinder untuk melakukan koreksi pada sumbu horisontal dan vertikal.Pada tesis ini telah dikembangkan metode koreksi output beam berbasis pada ray tracing analysis untuk menghitung struktur susunan lensa yang meliputi pengaturan fokus dan jarak antara lensa ndash; lensa silinder yang digunakan untuk mengurangi rasio elips serta lensa pemfokus untuk mendapatkan ukuran beam yang diinginkan. Hasil experiment terhadap metode koreksi beam diamati melalui dua cara yaitu; 1 pengamatan burning spot dengan mikroskop digital dan 2 menghitung hasil foto menggunakan MATLAB. Hasil kedua metode ini menunjukan pengurangan rasio elips. Pengurangan rasio elips dari 1.43 menjadi 1.14 pada pengamatan burning spot. Selain itu, dilakukan pula karakterisasi kebutuhan intensitas terhadap waktu pembakaran beberapa objek material.

ABSTRACT
In the process of engraving the use of high power lasers are rife in use today. The most commonly used high power lasers are gas lasers such as CO2, Nd YaG and also semiconductor, laser diodes. Laser diodes have some disadvantages such as wide divergence angles, astigmatism and elliptical beam profile. These deficiencies cause poor beam profile quality. Therefore it is necessary to do beam correction at the output diode to reduce the ratio of the ellipse it has. A common method of correction is to use two cylindrical lenses to correct the horizontal and vertical axes.In this paper use this ray tracing method for focus setting, the distance on the cylinder lenses and the focusing lens are used to reduce the ellipse ratio and obtain the desired beam size. The experimental results of the beam correction method were observed in two ways 1 observation of spot burning with digital microscope and 2 calculate the result of photo using MATLAB. The results of both methods show a reduction in the elliptical ratio. The reduction of the ellipse ratio is from 1.43 to 1.14 on the observation of burning. In addition, there is also characterization of the need for intensity to burning time of some material objects."
2017
T47744
UI - Tesis Membership  Universitas Indonesia Library
cover
Andeka Tris Susanto
"Saat ini komputasi tomografi (CT) sinar-X sudah banyak diterapkan di industri manufaktur untuk keperluan kontrol kualitas seperti penentuan cacat, porositas, koreksi geometri manufaktur dan reverse engineering. Kemampuan untuk memeriksa struktur internal material yang kompleks tanpa merusak konstruksi material tersebut merupakan salah satu keuntungan CT industri. Namun biaya perangkat CT industri komersial sangat mahal, karena hampir semuanya diimpor. Penelitian ini bertujuan untuk mengembangkan perangkat CT sinar-X berbasis fluoroskopi untuk industri manufaktur. Perangkat ini terdiri dari komponen utama yaitu detektor fluoroskopi, meja putar, pesawat sinar-X dan komputer beserta perangkat lunak akuisisi dan rekonstruksi citra. Telah dilakukan akuisisi citra dengan menggunakan berbagai benda uji dengan bentuk, material dan ketebalan yang berbeda beda. Kualitas citra tomografi berbagai benda uji sangat memuaskan. Data penelitian ini diharapkan dapat dijadikan referensi untuk pengembangan perangkat CT industri yang produksi dalam negeri dengan biaya lebih murah.

Currently, X-ray computed tomography (CT) has been widely applied in the manufacturing industry for quality control purposes such as defect determination, porosity, manufacturing geometry correction, and reverse engineering. The ability to inspect the internal structure of complex materials without destructive the construction of the material is one of the advantages of industrial CTs. However, the cost of commercial industrial CT devices is very expensive, because almost all of them are imported. This study aims to develop a development of fluoroscopy-based X-ray CT system for the manufacturing industry. The device consists of the main components, that is a fluoroscopy detector, a rotary table, an X-ray device, and a computer along with image acquisition and reconstruction software. Image acquisition has been carried out using various test objects with different shapes, materials, and thicknesses. The tomographic image quality of various test objects is very satisfying. Hopefully this research data can be used as references for the development of producing a low-cost industrial X-ray CT equipment made within the country."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
"The book is mainly focused on micromachining of transparent materials which, due to the nonlinear absorption mechanism of ultrashort pulses, allows unique three-dimensional capabilities and can be exploited for the fabrication of complex microsystems with unprecedented functionalities."
Berlin : Springer, 2012
e20425242
eBooks  Universitas Indonesia Library
cover
Madou, Marc J.
""Providing a clear theoretical understanding of MEMS and NEMS, Solid-State Physics, Fluidics, and Analytical Techniques in Micro- and Nanotechnology covers all aspects of solid state physics behind nanotechnology and science. After exploring the rise of Si, MEMS, and NEMS in a historical context, the text discusses crystallography, quantum mechanics, the band theory of solids, and the silicon single crystal. It concludes with coverage of photonics, the quantum hall effect, and superconductivity. The text offers end-of-chapter problems, worked examples throughout, extensive references, and PowerPoint slides for download, along with a solutions manual for qualifying instructors"--
"In Solid State Physics, Fluidics and Analytical Techniques in Micro- and Nanotechnology we lay the foundations for a qualitative and quantitative theoretical understanding of micro-and nano-electromechanical systems, i.e., MEMS and NEMS. In integrated circuits (ICs), MEMS and NEMS, silicon (Si) is still the substrate and construction material of choice"--"
Boca Raton, FL: CRC Press, 2012
621.381 52 MAD f
Buku Teks  Universitas Indonesia Library
cover
Paraginta Basaria
"The performance of anaerobic digestion (AD) to process organic fraction of municipal solid waste (OFMSW) can be improved with various pre-treatments. Mechanical pre-treatments, mainly chopping, have shown to be the most economical and relatively effective method to increase contact between the substrate and microorganisms. The purpose of this research was to analyze the effect of OFMSW particle size on CH4 gas formation in a laboratory-scale Biochemical Methane Potential (BMP) assay. The research was conducted for 35 days at a temperature of 35°C with three sizes of OFMSW co-digested with cow manure. OFMSW with particle sizes of 10-13 mm, 4.76-10 mm, and 2-4.76 mm produce CH4 gas with an average of 114.7+14.7 ml, 101.7+0.5 ml, and 110.9+10.8 ml, respectively, while methane yield was 0.277 L CH4/g VS, 0.208 L CH4/g VS, and 0.229 L CH4/g VS, respectively. Particle size is more likely to have an influence on the hydrolysis and acidogenesis processes, as demonstrated by the significant difference of VFA value, but not on the biogas potential. Particle sizes of 13-15 mm produce 19.25 mg VFA/L, while the size range of 2-4.76 mm produces 118.1 mg VFA/L."
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:8 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Raden Ajeng Wuriandita Wahyumurti Candra Kirana Dewi
"Teknologi mobile merupakan metode yang efektif bagi perusahaan travel e-Commerce dalam meningkatkan hubungan dengan pelanggannya sehingga timbul ketertarikan dan minat penggunaan. Selain itu, terdapat beberapa penelitian yang menunjukan bahwa usability memiliki hubungan yang positif terhadap minat penggunaan berkelanjutan dan loyalitas aplikasi mobile pada teknologi mobile. Maka dari itu, untuk memahami kebutuhan pengguna serta mematangkan strategi mobile, diperlukan analisis lebih lanjut untuk mengetahui faktor usability mana yang mendukung munculnya intensi penggunaan dan loyalitas aplikasi mobile pada aplikasi travel e-Commerce.
Penelitian ini dilakukan dengan menggunakan pendekatan sequential mixedmethods QUAN-QUAL. Data kuantitatif dikumpulkan melalui survei daring dengan memanfaatkan instrumen Mobile Application Usability (MAU) terhadap aplikasi Traveloka. Sebelum digunakan, MAU diterjemahkan ke dalam bahasa Indonesia menggunakan metode cross-cultural adaptation. Data kualitatif dikumpulkan melalui wawancara kontekstual dengan tujuan complementary dan completeness. Hasil data kuantitatif diolah dan dianalisis menggunakan metode Partial Least Square Structural Equation Modeling (PLS-SEM), sedangkan hasil data kualitatif diolah dan dianalisis menggunakan metode koding kualitatif.
Berdasarkan hasil survei, variabel yang signifikan dalam memengaruhi intensi penggunaan berkelanjutan dan loyalitas aplikasi mobile pada aplikasi Traveloka adalah susunan antarmuka dan utilitas aplikasi. Selain itu, berdasarkan hasil wawancara kontekstual, ditemukan faktor-faktor usability lain yang memengaruhi intensi penggunaan berkelanjutan dan loyalitas aplikasi mobile, yaitu langkah- langkah yang logis, hierarki yang logis, hierarki yang efisien, langkah-langkah yang efisien, pencarian, banyaknya pilihan preferensi, dan navigasi yang intuitif. Hasil ini sejalan dengan hasil data kuantitatif yang menunjukkan bahwa faktor yang lebih dominan tergabung dalam variabel yang signifikan. Walaupun demikian, navigasi yang intuitif merupakan satu-satunya faktor yang dominan selain dari variabel utilitas aplikasi dan struktur antarmuka sehingga bagian ini bertentangan dengan hasil data kuantitatif. Hasil penelitian ini diharapkan dapat menjadi acuan bagi perusahaan agen travel e-Commerce dalam mematangkan strategi perancangan aplikasi mobile yang efektif dari segi usability guna meningkatkan intensi penggunaan berkelanjutan dan loyalitas aplikasi mobile pada aplikasi travel e-Commerce mobile di masa yang akan datang.

Mobile technology is an effective approach for travel e-Commerce companies in enhancing relationships with their customers to drive interest and intention to use. There are plenty of research evidences to show that usability has a positive association with continued intention to use and mobile application loyalty on mobile technology. Therefore, to consider users’ needs and to overcome mobile strategies, further analysis is needed to discover which factors are important for driving intention to use and mobile application loyalty on travel e-Commerce applications.
This research was conducted using sequential mixed-methods QUAN-QUAL approach. Quantitative data was collected through an online survey using the Mobile Application Usability (MAU) towards Traveloka application. Before being utilized, the MAU was firstly translated into Indonesian using cross-cultural adaptation procedures. In the other hand, qualitative data was collected through contextual interview based on complementary and completeness objectives. The results of the quantitative data were processed and analyzed using partial least square structural equation modeling (PLS-SEM) method, while the qualitative data were processed and analyzed using qualitative coding method.
Based on the survey results, it was found that application utility and user interface structure are significantly important drivers of users’ continued intention to use and mobile application loyalty on Traveloka application. Besides, based on the results of the contextual interview, it was found that there were some other usability factors driving continued intention to use and mobile application loyalty dominantly, i.e. logical/intuitive path, logical/intuitive hierarchy, efficient hierarchy, efficient path, search, variety of preferences, as well as intuitive navigation. These results were in line with the quantitative data’s, that the dominant factors are belong to significant variables. However, intuitive navigation was the only dominant factor apart from the application utility and user interface structure variables, hence this part was contrary to the results of quantitative data. The results of this study are expected to be a reference for travel e-Commerce companies in maturing their mobile strategies effectively, especially in terms of usability, in order to engage mobile application loyalty and continued intention to use on mobile travel e-Commerce applications in the future.
"
Depok: Fakultas Ilmu Komputer Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>