Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 21979 dokumen yang sesuai dengan query
cover
Luthfan Fauzan
"Pada skripsi ini dilakukan rancang bangun awal perangkat pengukur pergerakan sendi lutut berbasis rugi-rugi serat optik yang dapat dipantau secara real time untuk skala laboratorium. Perangkat ini bekerja dengan memanfaatkan rugi-rugi lengkungan dari serat optik yang diintegrasikan pada knee support. Rugi-rugi lengkungan serat optik tersebut kemudian diproses dengan mikrokontroler Arduino Uno?ATmega328P dan rangkaian elektronik pendukung. Hasilnya berupa besar sudut pergerakan sendi lutut yang ditampilkan pada LCD.

In this final project, design of knee joints movement measurement device based on fiber optic bending loss which can be monitored in real time has been developed. It works by utilizing the bending losses of the optical fiber integrated in the knee support. Bending loss of the optical fiber were then processed using microcontroller Arduino Uno?ATmega328P and electronic circuits. The results of the knee joint movement angle were displayed on the LCD.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S63637
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Raditya Gumelar
"Pada skripsi ini dilakukan rancang bangun perangkat pengukur berat dengan memanfaatkan sensor serat optik. Sensor bekerja berdasarkan prinsip rugi-rugi macrobending pada serat optik jika mengalami gangguan. Sinyal keluaran serat optik yang diintegrasikan pada karet elastis selanjutnya diolah menggunakan Arduino Nano-ATmega328P beserta rangkaian pendukung.
Dari hasil pengujian untuk skala laboratorium, ditunjukkan bahwa perangkat bekerja dengan baik, yaitu menghasilkan keluaran yang berbanding lurus dengan masukan untuk rentang berat 0-2500 gram dengan resolusi 50 gram.

In this undergraduate thesis, a Body Weight Measuring Device Using Fiber Optic Sensor is designed. The fiber optic sensor works based on macrobending loses principle on optical fiber when experiencing interference. The output signal of the fiber integrated to elastic rubber band then processed using Arduino Nano-ATmega328P and supporting circuit.
From the test result in laboratory scale, it is shown that the designed device, can perform well in producing a proportionally linear output for 0 - 2500 gram weight range with 50 gram resolution.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S36315
UI - Skripsi Membership  Universitas Indonesia Library
cover
Awwah Halim
"Pada skripsi ini dilakukan rancang bangun perangkat pengukur laju alir gas oksigen menggunakan serat optik. Pengukur ini bekerja berdasarkan rugi macrobending pada serat optik ketika dilengkungkan. Serat optik yang dilengkungkan dikaitkan dengan penampang datar sehingga sensitif terhadap udara yang melewatinya. Sinyal keluaran kemudian diterima oleh fotodiode untuk diolah dengan rangkaian pendukung dan Arduino Uno-ATmega328P agar dapat ditampilkan pada display LCD. Berdasarkan hasil pengukuran skala laboratorium menggunakan gas oksigen, disimpulkan bahawa rancang bangun perangkat ini mampu mengukur laju alir oksigen dari 4 hingga 7 liter/menit dengan beda terhadap flowmeter 3,2%.

This research focus on developing of gases flowmeter. This instrument using macrobending loss fiber optic. The sensor consist of a bended fiber optic attached on a flat plate. The output signal then to be received by photodiode to be processed with an electronic circuit and an Arduino Uno-ATmega328P to be displayed on the LCD display. Based on this research in laboratory with oxygen gas, it can be concluded that this instrument can measure 4 until 7 litters per minute of oxygen flow and the different with flowmeter 3,2%.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S63632
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arika Dhia
"Naskah ini melapokan hasil rancang bangun perangkat pemantau respirasi untuk aplikasi inkubator bayi. Perangkat pemantau respirasi menggunakan sensor serat optik yang diintegrasikan pada kain lentur. Sensor bekerja dengan memanfaatkan perubahan rugi-rugi intensitas cahaya yang terjadi jika lengkungan serat optik berubah seiring dengan ekspansi rongga dada saat proses pernapasan. Daya keluaran serat optik dimasukkan ke rangkaian elektronika pendukung untuk selanjutnya diolah agar tingkat respirasi napas per menit dapat ditampilkan secara real-time pada LCD.Berdasarkan hasil pengujian yang dilakukan, ditunjukkan bahwa sistem mampu mengukur tingkat pernapasan dari rentang 10 hingga 130 napas per menit, dengan galat error 0.006 dan nilai hysteresis 0.2 .

This text reports the result of respiratory monitor design for infant incubator application. Respiratory monitor uses fiber optic sensor which is intergrated into supple fabric. Sensor utilizes light intensity losses difference that changes as thorax expansion during respiration. The fiber optic rsquo s output then goes to the supporting electronic circuits to be processed in Arduino Uno R3 so real time respiration rate the number of breath per minute can be presented on LCD.The result shows that the system is capable to measure respiratory rate in the range of 10 to 130 breath per minute with 0.00595 error and 0.2 hysteresis error."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S68691
UI - Skripsi Membership  Universitas Indonesia Library
cover
Astari Widyakinanti
"Pada penelitian ini dilakukan rancang bangun sensor microbending serat optik untuk memantau respirasi yang dapat menampilkan pola respirasi secara real time dalam bentuk grafik. Sensor respirasi bekerja berdasarkan prinsip rugi daya akibat microbending pada serat optik yang diintegrasikan pada karet elastis. Alat pemantau respirasi dilengkapi dengan mikrokontroler PIC18F14K50.
Dari hasil pengujian ditunjukkan bahwa alat pemantau respirasi dapat menampilkan berbagai macam pola pernafasan pada manusia dalam berbagai posisi dan jenis kegiatan secara real time, seperti menahan nafas, pernafasan normal, pernafasan dalam, dan pernafasan cepat.

In this research, the fiber optic microbending sensor for respiratory monitoring able to display respiratory pattern's graph in real time has been developed. This sensor works based on power loss due to fiber optic microbending that integrated with elastic textiles. This respiratory monitoring system equipped with PIC18F14K50 microcontroller.
The results showed that this respiratory monitoring system able to display human's breathing patterns for different positions and types of activities in real time, such as breath-holding, normal, deep, and rapid breathing.
"
Depok: Fakultas Teknik Universitas Indonesia, 2015
S60433
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aldo Kalula Angky
"ABSTRAK
Pada penelitian ini dilakukan rancang bangun sensor serat optik yang digunakan untuk memantau jumlah pernapasan dengan berdasarkan prinsip rugi daya akibat microbending pada serat oprik yang diintegrasikan pada kain lentur. Data dari hasil pembacaan mikrokontroller dikirim secara wireless, menggunakan sebuah wireless module Xbee Wireless Antenna Series dan dapat menampilkan data hasil pemantauan jumlah pernapasan secara real time.Dari hasil pengujian ditunjukkan bahwa alat pemantau pernapasan wireless ini menunjukkan hasil pada data yang dibaca telah dikirim tanpa menggunakan wireless module dan juga data yang dibaca dengan menggunakan wireless module.

ABSTRACT
In this research, has been built a fiber optic sensor for breathing monitoring using the microbending loss on the fiber optic which is built on elastic cloth. The data is sent wirelessly with the use of wireless module Xbee Wireless Antenna Series and capable of showing the data on graph in real time.The result showed that this respiratory sensor capable of showing the data with wireless module and without wireless module."
2017
S66514
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hariyanti
"Belum sempurnanya kerja organ pada bayi prematur membuat pemantauan kinerja organ vital sangat penting dilakukan, salah satu organ tersebut yang harus dipantau adalah pernapasan. Pada penelitian ini dikembangkan perangkat pemantau respirasi bayi prematur dalam inkubator Neonatal Intensive Care Unit NICU dengan memanfaatkan serat optik. Sensor bekerja berdasarkan prinsip rugi daya akibat macro bending pada serat optik. Rugi daya tersebut dapat diperoleh dengan cara melengkungkan serat optik dalam jumlah tertentu. Serat optik diintegrasikan pada bahan lentur yang ditempelkan pada permukaan atas popok sekali pakai di bagian abdomen bayi. Selanjutnya bahan lentur tersebut akan meregang dan mengendur seiring dengan pergerakan napas bayi. Perubahan regangan tersebut berdampak pada perubahan intesitas cahaya yang merambat di dalam serat optik. Selanjutnya cahaya keluaran dari sensor akan diterima fotodioda. Keluaran fotodioda berupa sinyal listrik selanjutnya diolah oleh rangkaian pengkondisi sinyal.
Arduino UNO digunakan untuk mengubah sinyal analog yang dihasilkan rangkaian pengkondisi sinyal menjadi sinyal digital dan dengan bantuan visual basic, data digital tersebut akan ditampilkan pada layar monitor. Perangkat juga dilengkapi dengan modul GSM sebagai penyedia fitur layanan pesan singkat SMS untuk pengiriman data tingkat pernapasan secara periodik, serta jika terjadi apnea pada bayi ke telepon selular.Dari pengujian perangkat, untuk skala laboratorium menggunakan ventilator sebagai simulator pernapasan ditunjukkan bahwa perangkat dapat menghitung tingkat pernapasan dari 10-100 napas per menit breath per minute/BPM secara real time dan kontinu, dengan tingkat keakurasian 99,75.

Rudimentary work of organs in premature infants make monitoring the performance of vital organs is very important. One of the most important organ that must be monitored is respiratory. In this research we developed a premature infant respiratory monitoring device in Neonatal Intensive Care Unit NICU incubator by utilizing optical fiber. Sensor work based on the principle of power losses due to macro bending on optical fibers. The power losses can be obtained by bending the fiber optic. Sensor of the optical fiber bending with certain curve diameter that integrated into flexible materials affixed to the top surface of disposable diapers in the infant's abdomen. Furthermore, the bending material will stretch and loosen with the movement of the infant's respiratory. The strain changes affect the light intensity received by the photodiode propagating inside the optical fiber which is then received by the photodiode to be converted into an electrical signal and processed by the signal conditioning circuit.
The Arduino UNO is used to convert the analog signals generated by the signal conditioning circuit to a digital signal using the visual basic program, then the digital data is displayed on the monitor screen. The device also equipped with a GSM module as a feature provider of short messege service SMS for periodic transmission of respiratory rate data as well as in case of apnea in infants to the mobile phone.From the experiment results for laboratory scale using ventilator as breathing simulator, showed that the device can calculate respiration rate from 10 100 breath per minute BPM in real time, with 99.75 of accuracy level.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
T51237
UI - Tesis Membership  Universitas Indonesia Library
cover
Joko Triwardono
"Sebagian besar implan sendi lutut komersial yang tersedia saat ini tidak dirancang untuk mencapai rentang gerak lebih dari 120°. Maka penelitian ini bertujuan untuk pengembangan implan sendi lutut dengan rentang gerak tinggi (High Flexion Prosthesis). Pengembangan produk implan sendi lutut diawali dengan melakukan reverse engineering. Analisa elemen hingga digunakan untuk menganalisa tegangan kontak dan luas kontak area yang dihasilkan khususnya analisa pada rentang gerak tinggi. Simulator gerak lutut dirancang untuk memvalidasi hasil simulasi agar memperoleh data yang valid. Simulator gerak lutut dirancang mengikuti standar, dibuat dengan spesifikasi enam derajat kebebasan. Dari hasil modifikasi desain didapatkan maksimal rentang gerak sebesar 159°. Dari hasil simulasi ASTM F3161, tegangan di permukaan femur kondyle rata-rata sebesar 0.034 MPa, lebih baik dari hasil simulasi produk benchmark yang nilai rata-ratanya sebesar 0.0413 MPa. Dari hasil simulasi ISO 14243 pada rentang gerak diatas 120°, luas kontak area antara komponen sisipan tibia dan komponen femur masih terukur khususnya di bagian post sisipan tibia. Ini mengindikasikan bahwa modifikasi desain yang telah dilakukan telah berhasil meningkatkan luas kontak area. Dengan hasil ini didapat kesimpulan bahwa untuk modifikasi desain sendi lutut dapat mengakomodir rentang gerak tinggi, mengurangi potensi keausan komponen dan dari hasil ekperimen tidak ditemukan potensi terjadinya subluxstation dan dislocation

Most commercial knee joint implants available today are not designed to achieve a range of motion greater than 120°. So this study aims to develop a knee joint implant with a high range of motion (High Flexion Prosthesis). Knee joint implant product development begins with reverse engineering. Finite element analysis is used to analyze the contact stress and the resulting contact area, especially analysis at high ranges of motion. The knee motion simulator is designed to validate the simulation results in order to obtain valid data. The knee motion simulator is designed according to standards, manufactured to a specification of six degrees of freedom. From the results of design modifications, the maximum range of motion is 159°. From the simulation results of ASTM F3161, the average surface tension of the femur condyle is 0.034 MPa, which is better than the simulation results of the benchmark product, which has an average value of 0.0413 MPa. From the ISO 14243 simulation results at a range of motion above 120°, the contact area between the tibial insertion component and the femur component is still measurable, especially in the post tibia insertion section. This indicates that the design modifications that have been made have succeeded in increasing the contact area. With these results, it can be concluded that modifications to the design of the knee joint can accommodate a high range of motion, reduce the potential for wear and tear of components and experimental results do not find the potential for subluxstation and dislocation."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Shepta Dh
"Sistem pengukur efisiensi sel Peltier berbasis mikrokontroler telah selesai dibuat. Sistem ini menggunakan prinsip kerja dari efek Seebeck dan efek Peltier. Dalam hal ini diterapkan teknologi termoelektrik dengan menggunakan bahan semikonduktor yaitu Sel Peltier. Sel Peltier akan bekerja ketika terjadi perbedaan temperatur di antara ujung sel dan menghasilkan arus listrik. Sistem ini menggunakan Heater 120 watt yang berfungsi sebagai sistem pemanas pada sistem, daya pada heater diatur dengan menggunakan PWM. Sistem ini juga menggunakan sistem pendingin yang dijaga konstan. Adanya perbedaan suhu pada sistem akan dibaca oleh sensor temperatur DS1820. Seluruh sistem dihubungkan pada komputer oleh mikrokontroler memalui kabel serial RS232. Semua hasil pengukuran ditampilkan pada LCD text dan monitoring komputer dengan menggunakan software LabVIEW. Berdasarkan hasil penelitian bahwa nilai efisiensi yang terukur merupakan hasil perbandingan antara daya output sel Peltier dan daya input heater.

The Efficiency Measurement System of Peltier Cell Based on Microcontroller has been designed. The system uses Seebeck effect and Peltier effect principles that is implemented by semiconductor-based thermoelectric technology. Peltier cell will work, that is generating electrical current, when the end plates of Peltier cell have a temperature difference. This sistem uses controllable 120W electrical heater that can be set by PWM method. Moreover, this sistem has also uses a cooling system to keep in a fixed temperature. The temperature difference will be read the DS1820 temperature sensor. The entire system is connected to a computer using RS232 communication cable. All measurement results acquaired by the system will be displayed on LCD text and monitoring computer using LabVIEW program. According to the conducted experiment,the measured efficiency which is the ratio of Peltier cell output power and heater input power, depends on the Peltier cell temperature difference."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S45675
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adnan Fatahillah Afiff
"Aplikasi dari serat optik yang banyak digunakan dan dikembangkan sekarang ini adalah untuk aplikasi biosensor. Biosensor digunakan untuk mendeteksi keberadaan suatu zat kimia bahkan suatu kumpulan bakteri pada daerah tertentu. Perkembangan biosensor optik saat ini umumnya menggunakan prinsip difraktif optik, surface plasmons, evanescent waves coupling, dan electrochemiluminescene. Dalam penelitian ini dirancang dan dibangun sebuah prototipe biosensor menggunakan serat optik multimode berbasis metode end-butt coupling yang digunakan untuk mendeteksi keberadaan zat atau larutan tertentu. Konfigurasi sensor serat optik ini menggunakan dua buah serat optik, dengan menghadapkan ujung serat optik pertama yang mentransmisikan cahaya sumber, dengan ujung serat optik kedua sedemikian rupa sehingga proses end-butt coupling dapat terjadi. Daerah antara kedua serat optik ini merupakan daerah deteksi yang digunakan. Perubahan indeks refraksi dan absobsi yang terjadi pada daerah deteksi tersebut digunakan sebagai parameter pendeteksian.

Application of optical fiber that is widely used and developed today is for biosensor applications. Biosensors used to detect the presence of a chemical substance and even a collection of bacteria in a certain area. The development of optical biosensors today generally uses the principle of diffractive optics, surface plasmons, waves evanescent coupling, and electrochemiluminescene. In this study, a prototype of a biosensor is designed and built using multimode optical fiber based on end-butt coupling method that used to detect the presence of certain substances or solvents. The optical fiber sensor configuration using two optical fiber, by aligning the end of the first optical fiber that transmits light source, with the end of the second optical fiber face to face that the end-butt coupling can occur. The area between the two fiber optic is the detection area that is used. Changes in refractive index and absorbtioin that occurs in the detection area is used as a detection parameter."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S46103
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>