cover
"Penelitian kenyamanan termal perlu banyak dilakukan di Indonesia, karena Indonesia berada di daerah tropis dan wilayah yang luas memiliki corak iklim yang berbeda antara daerah yang satu dengan yang lain. Penelitian ini bertujuan mendapatkan tingkat kenyamanan termal di Indonesia dengan metode penelitian laboratorium (ruang iklim) pada dua kota dengan iklim lokal yang berbeda, yaitu Kota Surabaya dan Malang. Penelitian ini diharapkan dapat melengkapi data penelitian kenyamanan termal sebelumnya di Indonesia. Dengan penelitian laboratorium, data respon termal diperoleh dengan menggunakan kuesioner tentang respon termal. Ruang iklim dirancang khusus dengan mengendalikan suhu udara dan kecepatan angin. Suhu udara di Malang diatur pada suhu udara 23,0-28,00[, sedangkan di Surabaya diatur pada suhu udara 28,0-31,00C. Sementara itu, kecepatan angin di kedua kota diatur pada ° m/s, 0,3 m/s, 0,4 m/s, 0,8 mis, dan khusus di Surabaya ditambah dengan kecepatan angin 1,0 m/s. Kuesioner meliputi tiga aspek, yaitu respon termal, keterterimaan termal, dan preferensi termal. Penelitian melibatkan total 41 responden dari Jurusan Arsitektur Universitas Brawijaya Malang dan Institut Teknologi Sepuluh November Surabaya. Analisis statistik yang meliputi analisis statistik deskripti], regresi tinier, serta regresi (binary logistic) digunakan untuk menganalisis data respon termal. Dari 454 respon termal, diperoleh suhu netral dan keterterimaan termal di kedua kota tersebut, sementara suhu preferensi memiliki korelasi yang tidak signifikan."
728 JUPKIM 9:1 (2014)
Artikel Jurnal  Universitas Indonesia Library
cover
Ahmad Burhani
"Pada suatu kabel tenaga, faktor panas merupakan suatu hal yang harus diperhatikan. Kapasitas arus suatu kabel tenaga dipengaruhi oleh karakteristik termal dari bahan-bahan yang menyusun kabel tersebut. Pada kabel tenaga panas yang timbul akibat rugi-rugi akan dilepaskan melalui bahan-bahan penyusun kabel yang memiliki resistansi termal yang cukup tinggi, sehingga proses disipasi panas pada suatu kabel lebih sulit dibandingkan saluran udara. Pemanasan yang terjadi pada kabel tenaga akan mempengaruhi bahan isolasi yang digunakan. Pemanasan yang melebihi ketahanan panas bahan isolasi akan mengakibatkan kegagalan bahan isolasi serta mempercepat penuaan.
Pengujian karakteristik termal pada kabel XLPE tegangan menengah 20 kV dilakukan dengan memberikan arus bolak-balik konstan pada suatu potongan kabel XLPE 20 kV tipe N2XEBY. Pengujian dilakukan sebanyak lima kali dengan level arus yang berbeda setiap pengujian. Pada pengujian diukur temperatur pada konduktor, bahan isolasi serta permukaan luar kabel setiap 15 menit sampai terjadi kesetimbangan temperatur (steady-state).
Dari pengujian yang dilakukan didapatkan bahwa pemberian arus listrik pada kabel mengakibatkan kenaikan temperatur pada bagian-bagian kabel, terutama konduktor, sampai mencapai keadaan setimbang (steady-state). Data hubungan antara kenaikan temperatur yang terjadi pada bagian-bagian kabel dengan waktu diregresikan dengan menggunakan fungsi step sehingga terlihat kenaikan temperatur maksimum, yaitu saat mencapai keadaan steady-state, serta time-constant-nya. Dari hasil pengujian juga diperoleh hubungan antara arus dengan kenaikan temperatur maksimum, arus dengan time-constant serta antara arus dengan selisih temperatur antara konduktor dan permukaan kabel."
Depok: Fakultas Teknik Universitas Indonesia, 2005
S40169
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ardi Muharini
"Sampel serpih (2), batubara (14) dan fosil resin (1) Formasi Telisa dan Cekungan Sumatera Selatan telah dianalisis dengan metode kromatografi gas - spektrometri massa (GC-MS). Sebagian sampel batubara (4) yang tersedia diantaranya dianalisis lebih lanjut menggunakan metode HPLC (kromatografi cairan penampilan tinggi). Seluruh sampel teranalisis telah diyakini mengandung resin tumbuhan tinggi dari famili Dipterocarpaceae seperti sekobikadinana diaromaik (dimer) dan trikadinana diaromatik (trimer) serta porfirin dari fraksi makromolekul.
Kedua kelompok dieter (C27 dan C30) dan trimer (C42 dan C45) telah diidentifikasi berdasarkan pada bukti spektra-massa dan waktu retensi kromatografi gas (GC). Perbedaan tiga atom karbon dengan massa 42 sma pada setiap kelompok diyakini berstruktur isopropil. Kelimpahan relatif dari dimer dan trimer bergantung pada kematangan termal sedimen dengan kematangan relatif moletas dimetilnaftil yang meningkat secara sistematik seiring dengan kenaikan kematangan termal sedimen.
Perubahan ini akibat proses deisopropilasi fraksi kadalenil (yang cenderung kurang stabil) menjadi dimetilnaftil (senyawa aromatik yang lebih stabil). Parameter baru berdasarkan pada kelimpahan relatif dari masing-masing analisis dimer dan trimer diusulkan dalam penelitian ini. Parameter baru ini merupakan rasio kuantitas isomer C27 terhadap kuantitas isomer sejenisnya (C27 dan C30), sekobikadinana diaromatik dan rasio kuantitas isomer C42 terhadap kuantitas isomer sejenisnya (C42 dan C45), trikadinana diaromatik, disebut RS dan RT masing-masing untuk dimer dan trimer.
Perubahan nilai RS dan RT terjadi di dalam zona jendela minyak-bumi. Batasan ` tak matang" dan "matang" ditentukan berdasarkan referensi, parameter kematangan baku Ro-vitrinite reflectance dan komputer pemodelan cekungan). Hasil penelitian ini, nilai RS = 52% dan RT = 2% merupakan rasio kematangan termal sampel dari Cekungan Sumatera Selatan. Parameter RT khususnya sangat berguna untuk penentuan kematangan termal pada zona "pascamatang" karena reaksi-deisopropilasi masih terus berlangsung pada zona tersebut.
Penelitian fraksi makromolekul telah dilakukan terhadap sebagian sampel batubara (4) yang tersedia. Hasil analisis dapat disimpulkan bahwa senyawa porfirin belum atau tidak ditemukan. Hal ini disebabkan prasarana yang digunakan tidak sesuai dengan literatur yang digunakan. Dengan perkataan lain, penelitian terhadap fraksi makromolekul tidak berhasil mengelusidasi porfirin."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1999
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Ginting, Aslina Br.
[Place of publication not identified]: Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir, 2009
URANIA 15 (1-4) 2009
Artikel Jurnal  Universitas Indonesia Library
cover
Dono Warsito
Depok: Fakultas Teknik Universitas Indonesia, 1994
S36335
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gunawan Muhamad Alif
"Pada beberapa peristiwa kebakaran, listrik sering kali dikaitkan sebagai salah satu penyebab utama dari kebakaran. Asap menjadi parameter awal yang mendasari terjadi sebuah peristiwa kebakaran. Keracunan asap adalah salah satu penyebab utama kematian korban kebakaran di dalam ruangan. Asap dapat membunuh manusia dengan melakukan kerusakan pada kombinasi termal, keracunan, dan iritasi paru-paru yang disebabkan oleh reaksi karbon monoksida, hidrogen sianida, dan produk pembakaran lainnya. Peristiwa kebakaran terjadi karena dalam beberapa kasus, banyak detektor asap yang gagal mencapai fungsinya sebagai pendeteksi awal asap karena waktu yang dibutuhkan asap untuk menjangkau sebuah detektor asap pada tempat tertentu ternyata membutuhkan waktu yang cukup lama.
Penelitian ini difokuskan pada kajian eksperimental untuk pendeteksian asap pada kebakaran kabel dengan parameter laju perkembangan luasan asap terhadap tingkat arus listrik dan perubahan waktu dengan pembebanan arus lebih dari titik kritisnya. Penelitian dilakukan dengan skala eksperimen. Frame hasil rekaman akan diukur luasan asapnya dengan menggunakan perangkat lunak ImageJ. Grafik laju perubahan waktu terhadap laju perkembangan luasan asap dengan perubahan tingkatan arus listrik dan kenaikan temperatur didapatkan guna mencari hubungan yang tepat terhadap tingkat bahaya kebakaran.
Hasil dari hubungan tersebut disesuaikan kedalam bahasa pemrograman Adaptive Gaussian Mixture Model dengan melakukan segmentasi obyek latar yang bergerak (foreground) dari latar belakang diam (background) untuk dijadikan parameter dalam penentuan tingkat bahaya asap dalam sistem deteksi asap berbasis pencitraan gambar. Terdapat pula pengujian hasil SEM (Scanning Electron Microscope) terhadap isolator PVC hasil percobaan.

At some events of fire, electricity is often attributed as one of the main causes of fires. Smoke becomes the early parameter that underlie a fire occurs. Smoke is also very dangerous to people. The smoke kills by a combination of thermal damage, poisoning and pulmonary irritation caused by carbon monoxide, hydrogen cyanide and other combustion products. In some cases, a lot of smoke detectors failed to achieve its function as an early detector of smoke because of the time needed to reach smoke detector in certain places took a long time.
This study focused on experimental studies for the detection of smoke in the fire cable with the rapid expansion parameters of smoke on the level of electrical current, temperature rise, and the time on the cable that deliberately be burned by flowing currents more than its critical point. Research is done by the experiment. In this study, the split frames that will each image area of the smoke were measured using ImageJ software. Graph of the rate changes of time to the extent of the smoke with the rapid changes in electrical current levels and an increase in temperature is obtained in order to find the correct relation to level the danger of fire.
Results from the relation are suited into Adaptive Gaussian Mixture Model to segment the moving object (as a foreground) from the background to be used as a parameter in determining the level danger of smoke in the smoke detection using imaging processing. This paper includes SEM (Scanning Electron Microscope) results for the PVC insulator.
"
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50863
UI - Skripsi Open  Universitas Indonesia Library
cover
cover
Heidi Laysandra
"ABSTRAK
Sifat struktur, termal, dan listrik pada temperatur tinggi dari senyawa double perovskite Sr2(Fe,Ti)O6telah dipelajari pada penelitian ini.Sr2(Fe,Ti)O6 disintesis dengan metode solid state reaction. Hasil karakterisasi x-ray diffraction pada temperatur kamar menunjukkan bahwa semua sampel memiliki fase tunggal dan memiliki struktur kristal kubik double perovskite dengan space grup pm3m. Variasi jumlah atom Fe dan Ti mengakibatkan kenaikan parameter kisi dan grainsize. Grainsize yang diperoleh berkisar antara 30 nm sampai dengan 80 nm. Sifat listrik sebagai fungsi temperatur dan frekuensi dikarakterisasi menggunakan RLC-meter dengan metode spektroskopi impedansi. Hasil karakterisasi disajikan dalam Nyquist plot dan Bode plot yang digunakan untuk mengidentifikasi rangkaian ekuivalen dan parameternya. Rangkaian ekuivalen yang diperoleh menunjukkan pengaruh grain dan grain boundary terhadap sifat material. Konduktivitas dc Sr2(Fe,Ti)O6 sebagai fungsi temperatur dijelaskan dengan menggunakan persamaan Arrhenius. Energi aktivasi yang diperoleh dari hubungan konduktivitas dc sebagai fungsi temperatur menunjukkan pengaruh grain dan grain boundary pada sampel. Hal tersebut menunjukkan kemungkinan adanya oxygen vacancy pada material Sr2(Fe,Ti)O6. Kemungkinan ini diperkuat dengan hasil karakterisasi field emission scanning electron microscopy (FESEM) untuk menggambarkan morfologi sampel

ABSTRACT
Structure, thermal, and electrical properties of double perovskite material Sr2(Fe,Ti)O6 at high temperature have been studied. Sr2(Fe,Ti)O6 was synthesized by solid state reaction method. X-ray diffraction characterization at room temperature for all samples show single phase and having cubic double perovskite structure with pm3m space group. The variation of Fe and Ti atoms result an increasing of lattice parameter and grainsize which is found between 30 nm and 80 nm. The electrical properties as a function of temperature and frequency are characterized by using RLC-meter with impedance spectroscopy method. The impedance data are presented in Nyquist and Bode plot resulting in the equivalent circuit and its parameters. The equivalent circuit shows the effect of grain and grain boundary in the electrical properties of materials. DC conductivity of Sr2(Fe,Ti)O6 as a function of temperature was explained by using Arrhenius equation. The value of the activation energy which is evaluated from dc conductivity as a function of temperature shows the effect of grain and grain boundary. The activation energy exhibits of oxygen vacancy in Sr2(Fe,Ti)O6 which is also supported by morphology of Sr2(Fe,Ti)O6 characterized by field emission scanning electron microscopy (FESEM)."
Universitas Indonesia, 2015
S60146
UI - Skripsi Membership  Universitas Indonesia Library
cover
Budi Rudianto
"Studi ini menampilkan pengaruh iklim dalam pembentukan panas bangunan pada rumah panggung di kawasan iklim tropis lembab. Rumah panggung di Kota Palembang merupakan salah satu tipe hunian masyarakat yang hingga kini masih didiami dan keberadaannya telah membentuk wajah kota. Tujuan penelitian adalah untuk mengetahui kinerja termal pada rumah panggung di Kota Palembang . Obyek penelitian menggunakan dua buah rumah panggung yang berada pada kawasan pemukiman tengah kota. Metode penelitian merupakan gabungan observasi dan simulasi. Program Archipak digunakan dalam melakukan simulasi. Kinerja termal kedua bangunan rumah panggung dibandingkan untuk mendapatkan hasil. Kinerja termal pada rumah panggung RP-11 lebih baik daripada rumah panggung RP-1 berdasarkan pada nilai total beban panas yang lebih rendah. Orientasi, bentuk bangunan, dan material merupakan faktor desain yang paling berpengaruh dalam pembentukan panas bangunan pada rumah panggung. Lantai panggung berkontribusi dalam mengurangi beban panas bangunana sepanjang hari. Ventilasi sangat efektif dalam mengurangi beban panas bangunan. Hasil penelitian akan digunakan untuk melakukan penelitian selanjutnya tentang rumah panggung modern."
Palembang: Fakultas teknik Universitas tridinanti palembang, 2016
600 JDTEK 4:1 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Pamuntjak, Ilya Adzani
"Kenyamanan okupan dalam sebuah ruangan dikaitkan dengan kenyamanan termal, kesehatan, dan kontrol. Maka, kenyamanan termal adalah salah satu hal yang harus dicapaikan oleh sistem pendingin yang tersedia untuk sebuah ruangan indoor. Analisis kenyaman dilakukan dalam auditorium Makara UI Art Center yang menggunakan Chiller berbasis Refrigeran Alami R290. Pemasangan sistem pendingin ini adalah pertama di Indonesia untuk lembaga akademis sebagai kontribusi Universitas Indonesia pada Green Campus Movement. Maka, relevan untuk mengetahui kondisi kenyamanan termal dalam auditorium dalam kondisi pembebanan parsial dan beban kosong. Analisis dilakukan menggunakan temperature logger real-time. Sistem HVAC tidak dapat bereaksi jika diberikan lonjakan beban panas dan kelembaban yang bersifat tiba-tiba, dan sistem memerlukan waktu sekitar 60 menit untuk mengembalikan kelembaban auditorium kembali dalam zona nyaman. Untuk kondisi auditorium penuh, suhu rata-rata adalah 21.750C, dengan kelembaban rata-rata 57.84%, untuk auditorium kosong suhu rata-rata adalah 21.80 C, dan kelembaban rata-rata sebesar 53.14%, yang berarti kategori kenyamanan untuk auditorium adalah Cool Comfort. Perbedaan suhu simulasi dan data lapangan sebesar 12.7% atau +2.630C. Kecepatan udara di atas kepala menurut simulasi adalah 0.2 hingga 0.4 m/s, dimana titik-titik yang mencapai lebih dari 0.25 m/s dapat dikatakan tidak nyaman.

The purpose of this research is to analyze the dry-bulb temperature and humidity about thermal comfort according to SNI 03-6572-2001 standards for the Makara Art Center auditorium at the University of Indonesia using a chiller with the natural refrigerant R290. Thermal comfort is important for the well-being of occupants in the auditorium; therefore, the space must be cooled efficiently to ensure comfort. Data loggers are used to log dry-bulb temperature and humidity data in the auditorium and the results are compared to the SNI-03-6572-2001 indoor thermal comfort standards to create a conclusion of the thermal comfort inside the space. The HVAC system is not capable to detect and mitigate high humidity levels, and requires atleast 60 minutes to return the air humidity to comfortable levels. For full auditorium conditions, the average temperature is 21,750C, with an average humidity of 57.84%, for the auditorium the average temperature is 21.80C, and the average humidity is 53.14%, which means the auditorium can be put in the category of Cool Comfort. The difference in simulation temperature and field data is +12.7% or + 2.630C. The overhead air speed according to the simulation is 0.2 to 0.4 m / s, which means locations reaching more than 0.25 m/s can be considered uncomfortable."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library