Lendy Prabowo
"Keandalan sistem pendinginan dan efisiensi energi merupakan hal yang sangat penting dalam keberhasilan dan keberlangsungan bisnis pada sebuah fasilitas pusat data data center . Faktanya, sumber utama kerusakan sebuah komponen/perangkat listrik disebabkan karena faktor temperatur 55 , kelembaban 19 , getaran 20 dan debu 6 pada kondisi lingkungan yang kurang memenuhi persyaratan. Tesis ini bertujuan untuk meningkatkan keandalan sistem pendinginan dan efisiensi energi dengan metode assesmen dan analisis software CFD Computational Fluid Dynamic dalam upaya meningkatkan margin profit perusahaan PT. X. Berdasarkan analisis kondisi eksisting didapatkan bahwa masih terdapat single point of failure pada sistem pendinginan pusat data dan konsumsi energi yang belum efisien. Perbaikan keandalan dilakukan dengan mengeliminasi sistem single point of failure penambahan manual switching system dan mengatur ulang konfigurasi CRAC Computer Air Conditioner unit operasi sesuai dengan kebutuhan total beban dan perbaikan efisiensi energi dilakukan dengan mengimplementasikan cold aisle containment. Implementasi cold aisle containment pada pusat data Switching lantai 2 dapat menghemat energi sebesar 987.523 kWh/tahun atau senilai Rp. 1.028.001.158 per tahun atau sama dengan persentase potensi penghematan energi sampai dengan 21 . Investasi yang dibutuhkan senilai Rp. 1.311.800.000, dengan asumsi biaya pemeliharaan 10 dari investasi dan depresiasi 5 tahun, maka akan didapatkan nilai kini netto NPV sebesar Rp. 1.648.876.628 dengan tingkat pengembalian internal IRR sebesar 44 . Adapun periode pengembalian investasi payback periode akan kembali dalam jangka waktu 3 tahun.

The reliability of cooling systems and energy efficiency is crucial to the success and sustainability of a business at a data center facility. In fact, the main source of damage to a component electrical device is due to temperature factors 55 , humidity 19 , vibration 20 and dust 6 under inadequate environmental conditions. This thesis aims to improve the reliability of cooling system and energy efficiency by method of assessment and analysis of CFD Computational Fluid Dynamic software in an effort to increase profit margin of PT. X. Based on the existing condition analysis it is found that there is still single point of failure in data center cooling system and energy consumption not yet efficient. Improved reliability is done by eliminating the single point of failure system adding manual switching system and rearranging the CRAC Computer Air Conditioner configuration of the operating unit according to the total load requirements and improving energy efficiency by implementing cold aisle containment. Implementation of cold aisle containment at data center Switching 2nd floor can save energy 987.513 kWh year or Rp. 1.028.001.158 per year or equal with potentialpercentage of saving energy until 21 .. The required investment is Rp. 1.311.800.000, assuming 10 maintenance cost of investment and depreciation of 5 years, it will get net present value NPV equal to Rp. 1.648.876.628 with an internal rate of return IRR of 44 . The return period of investment payback period will return within 3 years."
Depok: Fakultas Teknik Universitas Indonesia, 2017
T48028
UI - Tesis Membership  Universitas Indonesia Library
cover
Aditya Dhanist Pratama
"Keandalan sistem kelistrikan dan efisiensi energi pusat data merupakan dua hal terpenting dalam keberhasilan operasional pusat data. Analisis keandalan sistem kelistrikan dan efisiensi energi pusat data eksisting menjadi sangat penting untuk menghasilkan operasi yang handal dan efektif serta perencanaan pengembangan sistem yang tepat. Tesis ini bertujuan untuk meningkatkan keandalan sistem kelistrikan dan efisiensi energi dengan metode asesmen dalam upaya meningkatkan margin profit perusahaan PT. X. Berdasarkan analisis kondisi eksisting didapatkan bahwa masih terdapat titik kegagalan (single point of failure) pada sistem kelistrikan pusat data dan konsumsi energi yang belum efisien. Perbaikan keandalan dilakukan dengan mengeliminasi sistem titik kegagalan (penambahan trafo dan ATS) dan perbaikan efisiensi energi dilakukan dengan mengimplementasikan cold aisle containment. Implementasi cold aisle containment pada pusat data lantai 1 dapat menghemat energi 407.290 kWh/tahun atau senilai Rp. 427.397.839 per tahun. Investasi yang dibutuhkan senilai Rp. 518.442.247, dengan asumsi biaya pemeliharaan 10% dari investasi dan depresiasi 5 tahun, maka akan didapatkan nilai kini netto (NPV) sebesar Rp. 588.687.006 dengan tingkat pengembalian internal (IRR) sebesar 52%. Adapun periode pengembalian investasi (payback periode) akan kembali dalam jangka waktu 2 tahun.

The reliability of the electrical system and data center energy efficiency are the two most important things in the successful operation of the data center. Analysis of the reliability of the electrical system and the existing data center energy efficiency to be very important for generating reliable operation and effective and proper planning of system development. This thesis aims to improve the reliability of electrical systems and energy efficiency assessment methods in an effort to increase the profit margins of companies PT. X. Based on an analysis of existing conditions shows that there is still a single point of failure in the electrical system and the data center energy consumption has not been efficient. Repairs carried reliability by eliminating single point of failure system (additional transformer and ATS) and energy efficiency improvements made by implementing cold aisle containment. Implementation of cold aisle containment on data center floor one can save energy 407.290 kWh / year or Rp. 427.397.839 per year. The investment needed Rp. 518.442.247, assuming a 10% maintenance cost of investment and depreciation of 5 years, it will get the net present value (NPV) of Rp. 588.687.006 with an internal rate of return (IRR) of 52%. As for the period of return on investment (payback period) will be back within a period of 2 year."
Depok: Fakultas Teknik Universitas Indonesia, 2016
T45772
UI - Tesis Membership  Universitas Indonesia Library
cover
Yosep Sasada
"Penghematan energi pada gedung merupakan satu potensi yang besar mengingat konsumsi energi pada gedung dapat mencapai 37 dari total konsumsi energi di dunia. Cooling load sendiri atau space conditioning berperan penting di dalam konsumsi energi secara keseluruhan di dalam gedung, yaitu antara 40 - 70. Penelitian kali ini adalah membandingkan besar cooling load pada suatu gedung lembaga pendidikan antara tipe Baseline dan tipe Design dengan menggunakan perhitungan EEC GBCI serta dengan menggunakan software EnergyPlus dan OpenStudio. Pada tipe Design terdapat pengurangan nilai lighting power density, pengubahan material kaca dari yang awalnya memilik nilai SC sebesar 0,73 menjadi 0,4, serta penambahan shading aluminium extrusion sepanjang satu meter. Hasil yang didapatkan adalah terjadinya pengurangan cooling load sebesar 187,2 kW EEC GBCI dan 225,2 kW simulasi.

Energy savings on a building is a huge potential since it could be 37 of the world total energy consumption. Cooling load or space conditioning is major part of energy consumption in a building, roughly 40 ndash 70 of the total building consumption. This research aims to compare cooling load of the school, between Baseline type and Design type using EEC GBCI worksheet and using EnergyPlus and OpenStudio softwares. For the Design type there are reductions of lighting power density, glazing window material change from the initial that has 0.73 SC to 0.4 SC, and an addition of 1 meter aluminum extrusion shading. The result shows there are 187,2 kW EEC GBCI and 225,2 kW simulation reductions of the cooling load."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S68027
UI - Skripsi Membership  Universitas Indonesia Library
cover
Putu Indra Maha Trisna
"ABSTRAK
Proyek pengembangan lapangan LNG di tanah air kedepan akan didominasi oleh pembeli utama dari dalam negeri, sehingga tambahan kapal-kapal tanker LNG baru yang efisien dibutuhkan untuk rute domestik di masa mendatang. Secara teoritis sistem propulsi DFSM atau steam memiliki efisiensi termal yang rendah, namun lebih andal dibandingkan dengan sistem propulsi DFDE. Disisi lain sistem propulsi DFDE memiliki kekurangan pada teknologinya yaitu dengan adanya slip metana yang berpotensi sebagai penyebab pemanasan global dengan global warming potential GWP 20-25 kali lebih besar dari pada CO2 dalam periode 100 tahun atau 20 kali pada interval 20 tahun Kirk, 2008 , sehingga secara aktual mengurangi raihan efisiensi energi sistem propulsi tersebut.Dalam tesis ini, dua sistem propulsi kapal tanker LNG yaitu Dual Fuel Steam Mechanical DFSM dan Dual Fuel Diesel Electric DFDE yang saat ini paling banyak digunakan oleh operator di dalam negeri akan dibandingkan secara teknis dan ekonomis. Secara teknis, garis pedoman IMO tentang Energy Efficency Design Index EEDI dan Energy Efficiency Operational Index EEOI akan digunakan sebagai alat pembanding, sedangkan dari sisi ekonomis akan dilakukan analisa biaya daur hidup LCC berbasis biaya CAPEX dan OPEX kapal.Berdasarkan evaluasi teknis menggunakan garis pedoman EEDI dan EEOI tanker LNG dengan mempertimbangkan adanya slip metana pada sistem propulsi DFDE, didapatkan hasil bahwa nilai pencapaian EEDI dan EEOI pada sistem propulsi DFSM lebih rendah efisien dibandingkan dengan nilai pencapaian sistem propulsi DFDE dan evaluasi keekonomian berdasarkan biaya daur hidup LCC tanker LNG selama 20 tahun dengan mempertimbangkan risiko-risiko rugi dan penalti pengangkutan LNG yang mungkin terjadi akibat adanya kegagalan sistem propulsi dan sistem BOG, menunjukkan hasil sistem propulsi DFSM lebih efisien dibandingkan dengan sistem DFDE.

ABSTRACT
Future LNG field development projects in the country will be dominated by major domestic buyers, so additional new efficient LNG tankers are needed for domestic routes in the future. Theoretically DFSM or steam propulsion systems have low thermal efficiency, but are more reliable than DFDE propulsion systems. On the other hand the DFDE propulsion system has its technological deficiencies with the presence of a methane slip that has the potential to cause global warming potential with global warming potential GWP 20 25 times greater than CO2 in 100 years or 20 times at 20 years interval Kirk, 2008 , thereby actually reducing the energy efficiency of the propulsion system.In this thesis, two LNG tank propulsion systems that are Dual Fuel Steam Mechanical DFSM and Dual Fuel Diesel Electric DFDE which is currently the most widely used by operators in the country will be compared technically and economically. Technically, the IMO guidelines on the Energy Efficiency Design Index EEDI and the Energy Efficiency Operational Index EEOI will be used as a benchmark, while from the economic side life cycle cost analysis LCC performed based on CAPEX and OPEX ship costs.Based on a technical evaluation using EEDI and EEOI LNG tanker guidelines considering the presence of methane slip on the DFDE propulsion system, it was found that the EEDI and EEOI attainment values on the DFSM propulsion system were lower efficient than the achievement of the DFDE propulsion system and cost based economic evaluation LCC LNG tanker for 20 years taking into consideration LNG loss and LNG carrier penalties that may occur due to the failure of propulsion system and BOG system, shows the result of DFSM propulsion system is more efficient than DFDE system."
2017
T48123
UI - Tesis Membership  Universitas Indonesia Library
cover
Lemington
"ABSTRAK
Sistem pendingin mengkonsumsi bagian yang besar dari keseluruhan konsumsi energi pada sebuah gedung, terutama di daerah tropis seperti di Indonesia yang mempunyai permintaan sistem pendingin yang besar sepanjang tahun. Naskah ini mempresentasikan simulasi chiller sistem adsorpsi dengan 2 buah adsorber yang memanfaatkan tenaga matahari sesuai iklim di Indonesia. Chiller adsorpsi dimodelkan dan dikalkulasi secara matematika menggunakan perangkat lunak MATLAB®. Simulasi dilakukan secara transien selama jam kerja sehingga mendapatkan nilai temperatur pada titik-titik tertentu pada chiller. Selain itu, sistem mass recovery dan heat recovery juga diaplikasikan dalam sistem untuk memaksimalkan efisiensi. Chiller yang dimanfaatkan berdasarkan pada chiller terbaru yang dikembangkan oleh SJTU. Simulasi dijalankan pada beberapa variasi, yaitu pada input air panas temperatur 60oC dan 90oC untuk mendapatkan range performa chiller, kemudian dilakukan simulasi pada input sesuai radiasi. Selain itu, variasi juga dilakukan dengan penambahan PCM pada tangki air panas untuk meningkatkan efisiensi. Hasil simulasi menunjukkan range performa chiller berada pada COP 0,043-0,342. Secara umum, performa chiller apabila memanfaatkan energi matahari mencapai COP 0,282 dengan kapasitas pendinginan 17 kW, serta dengan adanya PCM mampu meningkatkan performa chiller.

ABSTRACT
Cooling system consumes a large part of energy consumption in a building, especially tropical area like Indonesia which has a high demand of cooling system along the year. This paper presented a simulation of two bed silica gel-water adsorption chiller utilizing solar energy based on Indonesia climate. The adsorption chiller is being mathematically modelled and calculated numerically using MATLAB®. The simulation is run transiently at working hours to achieve temperature in some points in the system. Furthermore, mass recovery and heat recovery is also applied in the adsorption cycle in order to increase the efficiency. The adsorption chiller is based on the most recent development by SJTU. Simulation is being run in some variations, for the stable hot water temperature in 60oC and 90oC in order to get the range of chiller performance. Then simulation is run using the radiation data as input energy. Another variation using PCM is also added to the hot water tank in order to increase the efficiency. The simulation results demonstrated the running characteristic of the chiller with the range of COP 0.043-0.342. In general, the chiller performance can reach COP 0.282 with 19 kW cooling capacity when utilize the solar radiation as input energy. Moreover, Adding PCM in hot water tank also can improve the chiller’s performance.
"
2015
S60120
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kemal Rahadian
"ABSTRAK
Solar Thermal Cooling System with its absorption cycle is expected to
replace the conventional air conditioning system with vapor compression cycle
because it is more efficient in terms of cost and energy. However, due to the heat
of the sun is not always stable, the system needs to be equipped with a backup
energy source, one of which is CNG. In the Manufacturing Research Center
building, the lack of facilities that support availability of CNG causes large
operating costs. Therefore, Optimization efforts with the aim to reduce operating
costs are needed. Simulation and optimization performed with EnergyPlus and
GenOpt. The conclusion is that the installation of 100 kW electric heater tankless
hot water storage tank is able to reduce total operating costs by 34.95% compared
to the use of a combination of solar thermal and CNG and 49.92% compared with
the full use of CNG.

ABSTRACT
Solar Thermal Cooling System with its absorption cycle is expected to
replace the conventional air conditioning system with vapor compression cycle
because it is more efficient in terms of cost and energy. However, due to the heat
of the sun is not always stable, the system needs to be equipped with a backup
energy source, one of which is CNG. In the Manufacturing Research Center
building, the lack of facilities that support availability of CNG causes large
operating costs. Therefore, Optimization efforts with the aim to reduce operating
costs are needed. Simulation and optimization performed with EnergyPlus and
GenOpt. The conclusion is that the installation of 100 kW electric heater tankless
hot water storage tank is able to reduce total operating costs by 34.95% compared
to the use of a combination of solar thermal and CNG and 49.92% compared with
the full use of CNG."
Fakultas Teknik Universitas Indonesia, 2014
S54286
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adiva Dewangga
"Baja S45C termasuk baja karbon sedang dengan persentase karbon 0,3% - 0,45%. Pada proses perlakuan panas, terdapat proses quenching dimana baja dicelupkan ke dalam suatu media quench secara cepat untuk menghasilkan sifat mekanis yang diinginkan. Pada penelitian ini digunakan micro thermal fluids sebagai media quench dimana micro thermal fluids adalah campuran antara nanopartikel yang terlarut dalam suatu fluida dimana nanopartikel tersebut berukuran dari 1-100 nm. Nanopartikel yang digunakan pada penelitian ini berbasis dari Printed circuit Board (PCB) dengan menggunakan fluida dasar air dan ditambahkan dengan surfaktan Sodium Dodecylbenzene Sulfonate (SDBS). Proses crushing, leaching, pirolisis, dan milling dalam upaya mengolah PCB menjadi nanopartikel. Setelah dilakukan PSA partikel yang melalui proses milling selama 20 jam sehingga 572.6 d.nm sehingga partikel tidak mencapai ukuran nano dan media pendinginnya disebut micro thermal fluid. Nilai kekerasan menunjukkan tren meningkat seiring dengan penambahan partikel, namun cenderung menurun saat dilakukan penambahan surfaktan. Nilai kekerasan tertinggi yang didapat pada sampel yaitu 55 HRC yang merupakan hasil quench dengan variabel 0,3% partikel 0% SDBS pada media pendingin. Kekerasan terendah yang dihasilkan adalah 44 HRC dengan variabel 0,5% partikel 7% SDBS. Mikrostruktur yang dihasilkan dari setiap penambahan partikel dan surfaktan adalah martensite,bainite, & pearlite.

S45C steel is classified as a medium carbon steel with a carbon percentage ranging from 0.3% to 0.45%.. Quenching is step where the steel is rapidly immersed in a quenching media to achieve desired mechanical properties. Nanofluids were used as quench media where nanofluids are a mixture of nanoparticles dissolved in a fluid where the nanoparticles are sized from 1-100 nm. The nanoparticles used in this study were based on a printed circuit board (PCB) using a water-based fluid and added with surfactant Sodium Dodecylbenzene Sulfonate (SDBS. After 20 hours of milling, the particle size was measured using Particle Size Analyzer (PSA) and found to be 572.6 d.nm, indicating that the particles didn’t reach the nano size range. Therefore, the cooling media was referred to as micro thermal fluid. The hardness value showed an increasing trend with the addition of nanoparticles, but tended to decrease with the addition of surfactant. The highest hardness value obtained was 55 HRC with the variable of 0.3% particles and 0% SDBS in the cooling media. The lowest hardness achieved was 44 HRC with the variable of 0.5% nanoparticles and 7% SDBS. The microstructure resulting from each nanoparticle and surfactant addition was martensite,bainite, & pearlite."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Idrus Alhamid
"Sektor bangunan di Indonesia membutuhkan sistem pendingin udara untuk menciptakan zona kenyamanan termal. Secara umum, energi listrik berasal dari pembakaran bahan bakar fosil, adalah bentuk energi tidak terbarukan dan memiliki masalah lingkungan. Di Indonesia, energi matahari dapat dimanfaatkan sepanjang tahun. Pemanfaatan energi matahari untuk sistem pendingin oleh panas memiliki keuntungan yang signifikan; yaitu sumber energi bersih, tersedia tanpa biaya langsung dan dapat diakses secara proporsional ketika beban pendinginan meningkat. Energi matahari untuk sistem absorption chiller di Indonesia adalah salah satu teknologi yang menjanjikan yang dapat memecahkan masalah energi dan lingkungan. Bekerja bersama Kawasaki Thermal Engineering dan Waseda University, Universitas Indonesia telah merancang dan membangun Solar Thermal Cooling System (STCS) pertama di Indonesia. Sistem ini menggunakan mesin chiller penyerapan efek-tunggal-ganda; terletak di gedung Manufactur Research Center (MRC), Fakultas Teknik Universitas Indonesia. Dari tipikal data uji lapangan, STCS dapat mengurangi konsumsi energi primer antara 11 dan 48% dibandingkan dengan kompresi uap dengan COP 3,1. Selain itu, disain dan penelitian ini juga memprediksi kinerja sistem ini di enam kota besar di Indonesia berdasarkan data uji lapangan: Jakarta, Surabaya, Medan, Yogyakarta, Makassar, dan Bali. Rata-rata dalam satu bulan untuk enam kota adalah 25,8 MWh pengurangan konsumsi gas setara dengan pengurangan 13,8 ton emisi CO2.

Building sector in Indonesia requires air conditioning systems to create comfort zones. Generally powered by fossil fuel combustion, electricity poses environmental issues as a non-renewable form of energy. In Indonesia, solar energy remains accessible throughout the year. Utilizing solar energy for heat-driven cooling systems offers significant advantages: a clean energy source, available at no direct cost, and proportionally accessible with increased cooling demand. Solar energy for absorption chiller systems in Indonesia presents a promising technology to address energy and environmental concerns. In collaboration with Kawasaki Thermal Engineering and Waseda University, the University of Indonesia has designed and constructed Indonesia's first Solar Thermal Cooling System (STCS). This system uses a double-effect absorption chiller, located at the Manufactur Research Center (MRC) building, Faculty of Engineering, Universitas Indonesia. Field test data indicates that the STCS can reduce primary energy consumption between 11 and 48% compared to vapor compression systems with a COP of 3.1. This design and research predict the system's performance in six major cities in Indonesia—Jakarta, Surabaya, Medan, Yogyakarta, Makassar, and Bali. On average, for these six cities in a month, there's a reduction of 25.8 MWh in gas consumption, equivalent to a decrease of 13.8 tons of CO2 emissions."
Depok: Fakultas Teknik Universitas Indonesia, 2023
PR-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Muhammad Arendio Walesa
"Solar panel adalah komponen photovoltaic yang mengubah energi matahari menjadi energi listrik. Energi matahari merupakan salah satu sumber energi terbarukan yang umum dijadikan sebagai alternatif sumber energi pengganti sumber konvensional. Dalam skripsi ini, dilakukan analisis matematis untuk desain dan biaya perencanaan sistem solar panel dengan kapasitas 196,37 kW dengan studi kasus di PT. Amarox Pharma Global. Berdasarkan hasil perencanaan desain yang dilakukan, meskipun dengan nilai penghematan energi yang sama. Penggantian sumber konvensional dengan solar panel keseluruhan akan menghasilkan BEP selama 8 tahun. Penggantian sumber listrik khusus pencahayaan (lighting) akan menghasilkan BEP selama 7 tahun 7 bulan. Instalasi sistem solar panel baik untuk penggantian sumber energi keseluruhan maupun penggantian sumber energi khusus pencahayaan juga diilustrasikan secara detail dalam skripsi ini.

Solar panel is a photovoltaic component which transforms sun radiation energy into electricity. Solar energy is one of the renewable energy source that are commonly used as an alternative for conventional energy. In this thesis, mathematical analysis was done for designing and planning the cost of solar panel system with 196.37 kW capacity from a study case done on PT. Amarox Pharma Global. According to the results of planning design, even with the same energy saving percentage value. The replacement of overall conventional energy source with solar panel circuit will cause BEP value reaches 8 years. Replacement for conventional energy source only in lighting circuit will result in BEP value reaches 7 years and 7 months. Solar panel installation system for both overall energy source replacement and lighting only energy source replacement is illustrated on this thesis."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rizqi
"Tingkat efisiensi penggunaan energi di Indonesia masih rendah, hal ini tentu saja menjadi masalah yang serius. Oleh karena itu harus ada upaya konservasi energi. Teknologi sistem CCHP Combined Cooling, Heating and Power pada bangunan hotel merupakan salah satu jawaban dari tantangan tersebut yang dibahas dalam penelitian ini.
Dalam penelitian ini dilakukan perbandingan antara pemakaian energi pada sistem eksisting listrik dari jaringan PLN/konvensional dengan sistem CCHP berdasarkan analisis teknis dan ekonomi pada hotel referensi. Selain itu juga akan dianalisis mengenai skema pengaplikasian sistem CCHP, yaitu sistem CCHP dibangun sendiri oleh pihak hotel atau melakukan kerjasama dengan ESCO melalui model bisnis BOT selama 10 tahun. Sistem CCHP disimulasikan dengan perangkat lunak berbasis analisis termodinamika dan konservasi energi dengan dasar desain FEL Following the Electric Load.
Hasilnya sistem CCHP mampu menghemat konsumsi energi primer sebesar 45,98 dibandingkan sistem eksisting. Sehingga akan terjadi penghematan biaya pengeluaran energi oleh pihak hotel. Pengaplikasian sistem CCHP pada hotel referensi dengan pembangunan sendiri akan memberikan keuntungan secara keekonomian dengan nilai NPV Rp 8.333.856.481, IRR 25,93 dan payback period 9 tahun. Sementara jika pembangunan dilakukan melalui skema kerjasama BOT dengan ESCO selama 10 tahun, dengan tarif energi flat sebesar Rp 1.402,75/kWh, maka akan mendapatkan keuntungan secara keekonomian dengan nilai NPV Rp 15.993.166.682, IRR 34,89 dan payback period 7 tahun. Emisi karbon dioksida CO2 dan nitrogen oksida NOx yang dihasilkan oleh sistem CCHP lebih sedikit 39 untuk emisi CO2 dan 75 untuk emisi NOx jika dibandingkan dengan sistem eksisting.

Level of efficiency of energy use in Indonesia is still low, it is of course become a serious problem. Therefore, there must be energy conservation efforts. CCHP Combined Cooling, Heating and Power system technology is one of the answers to these challenges that is discussed here.
In this study a comparison between the energy consumption in existing system from PLN electricity network conventional and CCHP system based on technical and economic analysis at the reference hotel. In addition, the scheme will also be analyzed regarding the application of CCHP system, by developing its own system of CCHP by the hotel or cooperating with the ESCO through BOT business model for 10 years. CCHP system is simulated with software based analysis of thermodynamics and energy conservation with the basic design of FEL Following the Electric Load.
As a result primary energy consumption saving from CCHP system is 45,98 compared to the existing system. So that there will be cost savings in energy expenditure by the hotel. CCHP system application in a reference hotel with its own development will provide the economic benefits with a value of Rp 8.333.856.481 NPV, IRR 25,93, and a payback period of 9 years. Meanwhile, if the construction was done through BOT scheme with ESCO cooperation for 10 years, with flat energy rate of Rp 1.402,75 kWh, then it will get the economic benefits with a value of Rp 15.993.166.682 NPV, IRR 34,89 and a payback period of 7 years. Emissions of carbon dioxide CO2 and nitrogen oxides NOx generated by CCHP system less 39 of CO2 emissions and 75 for NOx emissions when compared with existing systems."
Depok: Fakultas Teknik Universitas Indonesia, 2016
T47533
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>