Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 46469 dokumen yang sesuai dengan query
cover
Siregar, Leonardus
"The electric power is something that is very important and widely used in supporting human life, but the power is also very dangerous to human safety itself. Low voltage 220 V is part of the electric power distribution system. On this channel it is possible short circuit due to installation errors. Disturbances in this system becomes a possibility of being harmful to humans, because the electric current can make men swoon even death. So that people can avoid the danger that occurs, then the system installation households should be connected to the ground through a prisoner whose price is relatively low. Of the prisoners is to be investigated in the installation of existing homes in the city of Medan.
"
Universitas HKBP Nonmensen, 2017
050 VISI 25:2 (2017)
Artikel Jurnal  Universitas Indonesia Library
cover
A. Endang Sriningsih
"ABSTRAK
Suatu sensor pengukur medan magnit apabila dibuat dalam teknologi CMOS dalam array, akan mempunyai keluaran current mode yang sesuai dengan tegangan referensi dari chip tersebut. Array yang dibentuk akan merupakan suatu unit yang sangat peka yang akan menaikkan sensitifitas dan signal to noise to ratio-nya. Sensor ini disebut Sensor Medan Magnit Array CMOS dan mempunyai karakteristik yang linier. Sensor Medan Magnit yang ada sebelumnya, yaitu Sensor Medan Magnit Magfet mempunyai karakteristik yang tidak linier. Pada penelitian ini akan diamati tentang karakteristik Magfet sebagai komponen utama untuk pengintegrasi antara Magfet dengan load resistor dan Sensor Medan Magnit Array CMOS. Sensor Medan Magnit Array CMOS merupakan pengembangan dari Sensor Medan Magnit magfet Keluaran sensor medan magnit Array CMOS ini keluarannya akan dibuat digital dengan banluan suatu integrator dan Analog Digital Converter. Hal ini dapat dilakukan karena sensor inii mempunyai karakteristik yang linier."
Fakultas Teknik Universitas Indonesia, 1996
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Nji Raden Poespawati
Fakultas Teknik Universitas Indonesia, 1998
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Rudy Setiabudy
1996
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Amien Rahardjo
[date of publication not identified]
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Teguh Darmono
"Virtual Private Network (VPN) adalah jaringan lokal yang menggunakan media internet untuk dapat berkomunikasi antar jaringan lokal, sehingga memungkinkan jaringan lokal melalui internet berhubungan dengan jaringan lokal lainnya dengan beberapa pengamanan di beberapa sisi seperti adanya proses authentifikasi dan lainnya. Intinya dapat memenuhi kebutuhan internal terhadap layanan komunikasi data yang reliabel, efektif, dan senantiasa terhubung.
Teknologi VPN merupakan teknologi baru yang diterapkan di lingkungan kampus LAN Depkeu RI, yang peluncurannya pada awal maret 2006. Sekarang ini Depkeu Rl menggunakan 3 (tiga) jenis koneksi VPN antara lain :VPN lnternet, VPN IP, VPN Dial Up. Pada penerapannya VPN ini sudah digunakan oleh DJPLN (Direktorat Jenderal Lelang Negara), untuk mendukung salah satu aplikasinya yaitu SIMPLE, yang cara kerjanya mengarah kepada apa yang dinamakan dengan e-Auction, dengan VPN melalui 3 koneksinya di atas diharapkan proses administrasi pelelangan barang yang dilakukan DJPLN berjalan dengan terpusat dan bebas unsur kecurangan.
Tersebarnya kantor cabang di daerah merupakan kendala tersendiri untuk dapat menggunakan fasilitas SIMPLE ini, sehingga pada penulisan tesis ini, penulis membuat sebuah rancang bangun untuk kinerja trafik yang melalui ketiga koneksi VPN diatas, dan bertujuan mendapatkan sebuah pilihan Qas (Quality Of Service) jenis koneksi VPN dalam ruang Iingkup kampus LAN depkeu RI dibawah PUSINTEK (Pusat Sistem Informasi Teknologi Keuangan RI). Melalui penulisan ini diharapkn adanya sebuah referensi pilihan koneksi VPN di lingkungan Depkeu RI yang nantinya direkomendasikan ke semua Direktorat Jenderal lainnya, seperti PAJAK, BEA CUKAI, ANGGARAN dan lainnya."
Depok: Fakultas Teknik Universitas Indonesia, 2006
T16960
UI - Tesis Membership  Universitas Indonesia Library
cover
Rian Suryadiningrat
"Skripsi ini membahas mengenai sistem cerdas PV grid connected satu fasa pada distribusi energi listrik rumah tangga. Sistem ini terdiri dari dua sumber listrik, yaitu sumber listrik utama PLN (Perusahaan Listrik Negara) dan sumber listrik alternatif photovoltaic. Kondisi cerdas diperoleh berdasarkan pengaturan aliran daya ke beban melalui hasil deteksi dan identifikasi kondisi amplitudo, sudut fasa, dan frekuensi sumber listrik yang dibandingkan dengan kondisi referensi sistem. Mekanisme sistem berdasarkan deteksi sumber listrik menggunakan metode sistem static transfer switch (STS) melalui algoritma deteksi tegangan phase locked loop (PLL), kemudian menentukan algoritma decision making logic untuk mengatur kondisi switching. Hasil yang didapat menunjukkan kondisi aliran daya yang cerdas dapat diperoleh berdasarkan pemilihan sumber listrik hasil decision making logic saat terjadi gangguan.

Abstract
The focus of this thesis is a smart system of single phase PV grid connected in smart household energy system application. The system consists of two voltage sources are PLN (Perusahaan Listrik Negara) as preferred source and photovoltaic as alternative source. The condition of smart system can be described in power flow regulation to the load with detection and identification of amplitud, phase angle and frequency on voltage source compared to the system reference. The system mechanism based on detection of voltage source using static transfer switch (STS) to the voltage detection algorithm PLL and then determines decision making logic algorithm for switching conditions. The results show conditions of smart power flow can be obtained based on voltage source selection in decision making logic when fault conditions occur."
2011
S96
UI - Skripsi Open  Universitas Indonesia Library
cover
Dyan Puspita Apsari
"ABSTRAK
Pertumbuhan kebutuhan energi listrik memicu aliran daya yang semakin meningkat, begitu pula dengan perkembangan teknologi yang menyebabkan kebutuhan akan internet semakin meningkat. Dengan kemajuan teknologi saat ini, sudah terdapat suatu alat yang dapat memberikan jaringan ethernet dalam jarak yang lebih jauh. Alat tersebut merupakan alat komunikasi data menggunakan prinsip power line carrier (PLC), yaitu alat yang bekerja menggunakan dua adapter dengan mengubah sinyal ethernet menjadi sinyal powerline, dan menggunakan jaringan listrik 220-380V untuk komunikasi data tanpa membutuhkan kabel tambahan sebagai perantaranya. Namun, ketika jaringan listrik AC digunakan untuk mentransmisikan sinyal, kemungkinan gangguan dari disturbansi yang dihasilkan oleh sistem lain pada jaringan daya yang sama menjadi sangat tinggi. Pada penggunaan teknologi power line carrier sinyal pada rentang frekuensi tertentu akan dibangkitkan untuk tujuan komunikasi. Akan tetapi sinyal yang dibangkitkan ini menjadi disturbansi bagi alat lain yang tidak terlibat dalam proses komunikasi dan dapat mempengaruhi kinerja peralatan lain. Disisi lain, peralatan yang digunakan oleh rumah tangga akan memancarkan disturbansi pada rentang frekuensi 9-150 kHz yang dapat mempengaruhi sistem transmisi sinyal dan akan menghasilkan karakteristik yang berbeda-beda. Disturbansi akan mempengaruhi operasi kerja peralatan lain dan proses transmisi komunikasi data yang menyebakan frekuensi sinyal meningkat atau menurun. Penelitian ini memiliki fokus pada pengaruh disturbansi rentang frekuensi 9-150 kHz, dimana akan diukur pengaruh disturbansi terhadap komunikasi data yang menggunakan media power line carrier. Untuk variansi disturbansi digunakan beban rumah tangga, yaitu microwave inverter dan kompor induksi sebagai peralatan sumber disturbansi. Dengan menggunakan picoscope untuk melihat dan merekam disturbansi, data tersebut kemudian diolah dengan metode FFT dalam MATLAB untuk didapatkan karakteristik disturbansi pada setiap peralatan. Selanjutnya, dilihat pengaruh disturbansi tersebut terhadap komunikasi data yang mengalir pada jaringan listrik yang digunakan. Berdasarkan hasil penelitian, dapat disimpulkan bahwa nilai disturbansi yang dihasilkan oleh peralatan rumah tangga pada frekuensi 19 kHz akan mempengaruhi kualitas transfer atau komunikasi data pada power line carrier. Dimana pada kelima pengujian, semakin meningkatnya nilai disturbansi dengan nilai rata-rata sebesar 725.2 mV, 940.9 mV, 1060.4 mV, 1447.4 mV, dan 1673.9 mV akan mengakibatkan peningkatan packet loss sebesar 0.0037%, 0.201%, 0.25%, 0.5%, dan 0.5252%.

ABSTRACT
The growth of electrical energy needs triggers an increasing power flow, as well as the technological developments that cause the Internet needs to increase. With the advancement of current technology, there is already a tool that can provide Ethernet network in a much longer distance. The tool is a data communication tool using the principle of power line carrier (PLC), which is a tool that works using two adapters by converting the Ethernet signal into a powerline signal, and using a 220-380V power grid for data communication without needing additional cables as its medium. However, when the AC power grid is used to transmit the signal, the likelihood of interference from disturbance generated by other systems on the same power network becomes very high. On the use of power line carrier signal technology on certain frequency ranges will be raised for communication purposes. However, this raised signal becomes a disturbance for other tools that are not involved in the communication process and may affect the performance of other equipment. On the other hand, equipment used by households will emit disturbance at a frequency range of 9-150 kHz that can affect the signal transmission system and will produce different characteristics. The disturbance will affect the work operation of other equipment and the transmission process of data communication that degrade signal frequencies increasing or decreasing. This research has a focus on the influence of disturbance frequency range of 9-150 kHz, which will be measured disturbance influence on data communication using the power line carrier media. For variances disturbance used household load, namely microwave inverter and stove induction as a source equipment disturbance. By using a picoscope to view and record disturbance, the data is then processed by FFT method in MATLAB to be obtained disturbance characteristics of each equipment. Furthermore, the Disturbance influence the data communication that flows in the electricity network used. Based on the results of the study, it can be concluded that the disturbance value produced by household appliances at 19 kHz frequency will affect the quality of transfer or data communication in the power line carrier. Where in the fifth Test, the increasing value of disturbance with an average value of 725.2 mV, 940.9 mV, 1060.4 mV, 1447.4 mV, and 1673.9 mV will result in increased packet loss of 0.0037%, 0201%, 0.25%, 0.5%, and 0.5252%."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arifin Djauhari
Depok: Fakultas Teknik Universitas Indonesia, 1993
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Cogdell, J.R.
Englewood Cliffs, NJ: Prentice-Hall, 1990
621.3 COG f
Buku Teks  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>