Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 148941 dokumen yang sesuai dengan query
cover
Reyhan Puji Putranto
"Isoeugenol merupakan hasil turunan produk minyak cengkeh yang banyak dimanfaatkan dalam industri parfum, aroma dan rasa makanan, minyak esensial, obat, antioksidan serta antibakteri. Pada penelitian ini, studi elektrokimia isoeugenol dipelajari sebagai dasar dalam pengembangan proses konversi isoeugenol menjadi produk bernilai manfaat tinggi. Penelitian ini menggunakan elektroda kerja emas, boron doped diamond, dan boron doped diamond termodifikasi emas. Preparasi elektroda BDD Au dilakukan dengan metode elektrodeposisi menghasilkan ukuran partikel Au sekitar 500 nm dan morfologi berupa poligonal sisi. Elektroda pendukung dan elektroda acuan masing-masing menggunakan platina spiral dan Ag/AgCl dalam 1 M KCl.
Parameter matriks larutan menggunakan variasi pH buffer Britton-Robinson dalam akuabides. Berdasarkan voltamogram siklik diperoleh pH optimum untuk elektrooksidasi isoeugenol menggunakan elektroda emas, boron doped diamond dan boron doped diamond termodifikasi emas terjadi pada masing-masing nilai pH 3, pH 6, dan pH 3. Nilai potensial oksidasi untuk elektroda emas, boron doped diamond dan boron doped diamond termodifikasi emas adalah 660 mV, 710 mV dan 662 mV. Nilai arus oksidasi untuk elektroda emas, boron doped diamond dan boron doped diamond termodifikasi emas adalah 108,28 A; 52,813 A dan 106,689 A.

Isoeugenol is a derivative product of clove oil which is widely used in perfume industry, aroma and taste of food, essential oil, medicine, antioxidant and antibacterial. In this study, electrochemical studies of isoeugenol were studied as a basis in the development of isoeugenol conversion process into high value products. This study used gold, boron doped diamond, and boron doped diamond modified gold as working electrodes. BDD Au electrode preparation was performed by electrodeposition method yielding Au particle size about 500 nm and morphology of polygonal side. Supporting electrode and reference electrode are using spiral platinum and Ag AgCl in 1 M KCl.
Matrix solution is use a variation of Britton Robinson buffer pH in aquabides. Based on the cyclic voltammogram obtained the optimum pH for isoeugenol electrooxidation using gold electrodes, boron doped diamond and boron doped diamond modified gold occur in each pH value 3, pH 6, and pH 3. Oxidation potential values for gold electrodes, boron doped diamond and boron doped diamond modified gold is 660 mV, 710 mV and 662 mV. The oxidation current values for gold electrodes, boron doped diamond and boron doped diamond modified gold are 108.28 A 52.813 A and 106,689 A.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Sadewo Panghudi Luhur
"Elektroda Boron-Doped Diamond termodifikasi core-shell nanopartikel AuPd telah berhasil dipreparasi dengan cara perendaman BDD terminasi N dalam koloid nanopartikel AuPd. Lapisan shell Pd NP terbentuk pada core nanpartikel Au dari hasil reduksi larutan HAuCl4 dengan variasi penambahan H2PdCl4 1,0 mM dan asam askorbat. Spektrum UV-Vis dari nanopartikel Au menunjukkan panjang gelombang maksimum pada ? = 523 nm yang diikuti dengan penurunan absorbansi AuPd NP seiring pembentukan nanopartikel palladium. Karakterisasi nanopartikel menggunakan Transmission Electron Microscopy TEM menunjukkan bahwa core-shell AuPd NP memiliki bentuk flower shape dengan diameter Au NP sebesar 14,26 nm dan ketebalan Pd NP masing-masing 6,91 nm dan 4,05 nm. AuPd NP yang dideposisi ke permukaan elektroda BDD-N dikarakterisasi menggunakan Scanning Electron Microscopy Energy Dispersive X-Ray SEM-EDX dan X-Ray Photoelectron Spectroscopy XPS. Penentuan kadar oksigen dilakukan menggunakan teknik siklik voltammetri dalam larutan buffer fosfat PBS dengan variasi lamanya waktu aerasi oksigen yang diukur menggunakan DO meter. Hasil pengukuran menujukkan bahwa kemampuan pemisahan sinyal arus terhadap background pada elektroda BDDN-AuPdNP 1 S/B = 2,82 lebih baik dibandingkan BDDN-AuNP S/B = 2,59 dan BDDN-AuPdNP 2 S/B = 1,12 . Pembentukan Pd NP pada permukaan Au NP mempengaruhi sensitifitas pada elektroda sehingga modifikasi elektroda BDD-N dengan nanopartikel AuPd diharapkan dapat menghasilkan elektroda yang lebih sensitif untuk pengukuran oksigen dan dapat dikembangkan selanjutnya untuk penentuan BOD dalam air.

Core shell nanoparticle Au Pd modified Boron Doped Diamond electrode has been succesfully prepared by immersion of BDD terminating N in Au Pd colloid nanoparticles. The Pd shell layer was formed on Au nanoparticle cores from the reduction of HAuCl4 solution with variations of 1.0 mM H2PdCl4 volume addition and ascorbic acid. UV Vis spectra of Au nanoparticles showed the maximum wavelength was obtained at 523 nm which followed by the decreasing of absorbance of AuPdNP as the formation of Pd shell. Characterization of nanoparticles using Transmission Electron Microscopy TEM shows that the AuPd Np core shell has a flower like shape with 14.26 nm of AuNP core diameter and PdNP shell thickness of 6.91 nm and 4.05 nm, respectively. The AuPd NPs were deposited on BDD N surface and were characterized using Scanning Electron Microscopy Energy Dispersive X Ray SEM EDX and X Ray Photoelectron Spectroscopy XPS. Determination of oxygen level was carried out using cyclic voltammetry in phosphate buffer solution PBS at various oxygen aeration time where its concentration was measured using DO meter. The results show that BDDN AuPdNP 1 had a better current to background signaling capability S B 2.82 than BDDN AuNP S B 2.59 and BDDN AuPdNP 2 S B 1.12 . It is belived that the formation of Pd shell on the surface of Au NP affects the sensitivity of the electrode. As the result, modification of BDD N electrodes with Au Pd nanoparticles are expected to produce more sensitive electrodes for oxygen measurements which can be further developed for Determination of BOD in the water."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S69087
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dian Tri Lestarini
"Elektroda boron doped-diamond BDD termodifikasi emas Au telah berhasil dipreparasi dengan cara seeding diikuti elektrodeposisi larutan HAuCl4 pada permukaan elektroda. Teknik seeding berfungsi untuk membuat bibit benih inti emas pada permukaan elektroda BDD melalui adsorpsi fisik. Sedangkan elektrodeposisi dilakukan untuk menghomogenkan ukuran dan sebaran partikel emas di permukaan elektroda BDD. Partikel Au yang terdeposisi dipermukaan elektroda BDD dikarakterisasi menggunakan Scanning Electron Microscopy-Energy Dispersive Spectroscopy SEM-EDS dan X-Ray Photoelectron Spectroscopy XPS. Deteksi As3, As5, dan campuran As3 dan As5 dilakukan dengan teknik anodic stripping voltammetry ASV. Mula-mula dilakukan pre-treatment menggunakan NaBH4 untuk mereduksi As5 menjadi As3 untuk menurunkan potensial deposisi As3 karena deposisi As5 memerlukan potensial deposisi yang sangat negatif dan dapat menimbulkan evolusi gas hidrogen yang dapat mengganggu pengukuraan. Respon arus terhadap masing-masing larutan standar As3 dan As5 menunjukkan linearitas yang baik pada rentang konsentrasi 0,1-1 ppmdengan R2= 0,97598 untuk As3 dan range konsentrasi 0,048-0,48 ppm dengan R2= 0,98767 untuk As5 . Limit deteksi yang dihasilkan pada pengukuran As3 sebesar 0,1675 ppm, sedangkan As5 0,0574 ppm. Pengukuran pada campuran As3 dan As5 menunjukkan linearitas yang tinggi, mengindikasikan bahwa dimungkinkan untuk mengukur konsentrasi masing-masing As3 dan As5 dalam matriks campuran.

Boron doped diamond BDD electrode modified with gold particles Au has been successfully prepared by seeding followed by electrodeposition of HAuCl4 solutions at the electrode surface. The function of seeding method is to deposite gold seeds onto the electrode surface by physical adsorption. Whereas the electrodeposition was performed to homogenize the size and distribution of the particles at the BDD electrode surface. The deposited gold particles on BDD surface were characterized using Scanning Electron Microscopy Energy Dispersive Spectroscopy SEM EDS and X Ray Photoelectron Spectroscopy XPS . Detection of As3 , As5 , and mixture solutions of As3 and As5 using anodic stripping voltammetry. Initially, pretreatment used NaBH4 was performed to reduce As5 to As3 , therefore the deposition potential can be decreased. It is known that As5 required high negative deposition potential, which can cause hydrogen gas evolution which can affecting the measurements. Good linear responses for each solution were observed in range consentration of 0,1 1 ppm for As3 R2 0,97598 and range concentration of 0,048 0,48 ppm for As5 R2 0,98767. Limit of detections of 0,1675 ppm and 0,0574 ppm can be achieved for As3 and As5 , respectively. Measurements of mixture solutions of As3 and As5 showed high linearity, indicating that detection of each species of As3 and As5 can be performed in mixture As3 and As5."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Tiara Nur Annisa
"Akrilamida merupakan senyawa kimia yang terbentuk dalam proses pemanasan pada suhu tinggi di makanan yang memiliki kadar karbohidrat tinggi. Akrilamida bersifat karsinogenik untuk manusia. Dalam darah manusia yang terpapar akrilamida ditemukan terbentuknya ikatan antara ikatan rangkap pada akrilamida dengan ?-NH2 dari gugus N-terminal valin pada hemoglobin Hb . Ikatan tersebut menjadi dasar penggunaan Hb sebagai biosensor dalam pengembangan sensor akrilamida. Pada penelitian ini elektroda boron-doped diamond BDD dimodifikasi menggunakan nanopartikel emas AuNP dan Hb melalui terminasi gugus nitrogen pada permukaan BDD untuk memperoleh elektroda dengan selektifitas, sensitifitas, dan afinitas yang baik, serta kemampuan untuk digunakan kembali sebagai biosensor akrilamida. Sebelum dimodifikasi dengan Hb, BDD-N dimodifikasi terlebih dahulu dengan AuNP. Elektroda ini BDD-N/AuNP/Hb kemudian dibandingkan perilaku elektrokimianya dengan elektroda Au/Hb.
Pengukuran siklik voltametri pada elektroda Au/Hb mengasilkan konsentrasi optimum Hb pada elektroda Au Au/Hb adalah 0,6 mg/mL, dan 0,02 mg/mL pada elektroda BDD BDD-N/AuNP/Hb . Pengukuran menggunakan siklik voltametri menunjukkan bahwa penambahan konsentrasi akrilamida menyebabkan puncak arus turun secara linier dari konsentrasi 0 ndash; 30 M dengan estimasi LOD 38,15 M untuk elektroda Au/Hb dan 6,61 M untuk elektroda BDD-N/AuNP/Hb. Hasil mengindikasikan bahwa elektroda BDD-N/AuNP/Hb memiliki performa yang lebih baik daripada elektroda Au/Hb untuk digunakan sebagai biosensor akrilamida.

Acrylamide is a chemical compound, which formed at high temperature of heating process on foods with high carbohydrate content. Acrylamide is reported to be carcinogenic to human. Human blood exposed to acrylamide was found to form the bond between the double bond of acrylamide and NH2 group of N terminal valine of hemoglobin Hb . This behavior was served a useful purpose to be applied as the biosensor to develop an acrylamide sensor. In this work, boron doped diamond BDD was modified with gold nanoparticles AuNPs and Hb through nitrogen groups on the surface of BDD to obtain an electrode with the good selectivity, sensitivity, and affinity, also reusable for acrylamide biosensors. Prior to modify with Hb, the BDD was modified with AuNPs to increase the affinity of BDD with nitrogen termination N BDD against Hb. The electrochemical behavior of the hemoglobin modified through gold nanoparticles on the surface of N BDD electrode Hb AuNPs N BDD in the presence of acrylamide was studied in comparison to hemoglobin modified gold electrodes Hb Au.
Cyclic voltammetry indicated the optimum concentration of Hb was obtained at 0.6 mg mL in Hb Au electrode and 0.02 mg mL in Hb AuNPs N BDD electrode. Cyclic voltammetry measurements showed the linear decrease of the peak current with the increase of acrylamide concentration. The responses were linear against the acrylamide concentration range of 0 30 M with an estimated LOD of 38.15 M at Hb Au electrode and 6.61 M at Hb AuNPs N BDD electrode. The results indicated that Hb AuNPs N BDD electrode has a better performance than Hb Au electrode as the acrylamide sensors.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S68868
UI - Skripsi Membership  Universitas Indonesia Library
cover
Wulan Tri Wahyuni
"Neuraminidase (NA) merupakan enzim yang dapat dimiliki oleh virus, mikroba, dan mamalia, termasuk di antaranya mikroba dan virus patogen. Deteksi NA merupakan aspek penting dalam upaya mengawasi penyebaran penyakit infeksi yang disebabkan oleh mikroba dan virus patogen tersebut. Di samping itu, analisis kuantitatif NA penting dalam penentuan komposisi vaksin. Pada penelitian ini dikembangkan metode deteksi NA dengan teknik elektrokimia berdasarkan inhibisi NA oleh zanamivir. Deteksi NA dilakukan berdasarkan perubahan respon elektrokimia zanamivir dalam buffer fosfat pH 5,5 saat terdapat NA dan tidak. Elektroda Boron doped diamond termodifikasi emas, yaitu Au-BDD dan AuNPs-BDD digunakan sebagai elektroda kerja dan pengukuran dilakukan menggunakan teknik voltametri siklik. Deteksi NA dikembangkan juga pada sistem magnetic beads dan sistem strip test. Pengembangan sistem magnetic beads dimaksudkan sebagai upaya untuk meningkatkan sensitivitas deteksi, sementara sistem strip test merupakan pengembangan awal untuk membuat piranti praktis pengukuran NA. Pengaruh mucin terhadap performa deteksi NA diamati dengan menggunakan mucin submaxillary 0,33 mg/mL. Hasil yang diperoleh menunjukkan bahwa terjadi korelasi linear antara konsentrasi zanamivir dengan intensitas puncak arus oksidasi dan reduksi Au pada elektroda BDD termodifikasi emas. Linearitas pengukuran zanamivir berdasarkan puncak arus reduksi emas pada elektroda Au-BDD diperoleh pada kisaran 5 x 10-6 - 1 x 10-4 M (R2 = 0,990) dengan limit deteksi (LOD) 1,49 x 10-6 M, sementara pada elektroda AuNPs-BDD diperoleh pada kisaran konsentrasi 1 x 10-6 - 1 x 10-5 M (R2 = 0,998) dengan LOD 2,29 x 10-6 M. Keberadaan NA menyebabkan konsentrasi zanamivir bebas dalam larutan berkurang dan menurunkan zanamivir yang teradsorpsi pada permukaan selektroda. Akibatnya puncak arus oksidasi dan reduksi Au pada elektroda Au-BDD dan AuNPs-BDD meningkat. Kalibrasi linear konsentrasi NA dengan puncak arus reduksi Au pada elektroda Au-BDD diperoleh pada kisaran 0 ? 15 mU (R2 = 0,996) dengan LOD 0,25 mU dan %RSD 1,18 %, sementara kisaran linear 0 ? 12 mU (R2 = 0,997), LOD 0,12 mU, dan %RSD 2,49% diperoleh saat pengukuran dilakukan dengan elektroda AuNPs-BDD. Keberadaan mucin tidak memberikan pengaruh yang berarti terhadap deteksi NA dengan metode yang dikembangkan. Sistem magnetic beads belum berhasil meningkatkan sensitivitas deteksi NA. Nilai LOD pengukuran yang diperoleh ialah sebesar 0,64 mU pada kisaran linear 0 ? 8 mU. Deteksi NA pada sistem strip test yang dikombinasikan dengan pengukuran elektrokimia telah berhasil dikembangkan pada kisaran linear 0 - 15 mU dengan nilai LOD sebesar 0,26 mU. Deteksi NA dalam matriks mucin dapat dilakukan pada sistem strip test sekalipun keberadaan mucin dilaporkan dapat menurunkan presisi pengukuran.

Neuraminidase (NA) is a hydrolase enzyme which is commonly found in viruses, microbes, and mammals, including pathogenic microbes and viruses. Detection of NA is very important for monitoring the spread of such pathogen microbes and viruses. Meanwhile, the quantification of NA is also crucial for vaccine composition investigation. Development of an electrochemical method for NA detection using gold modified boron doped diamond (Au-BDD and AuNPs-BDD) electrodes were conducted in this study. The detection method was developed based on the difference of electrochemical responses of zanamivir in the presence and the absence of NA in phosphate buffer solution pH 5,5. Measurements were performed using cyclic voltammetry technique. Detection of NA also developed on magnetic beads in order to improve the sensitivity of measurement. On the other hand, to build up a practical devices for NA detection, preliminary development of strip test was conducted by using Au-BDD as working electrode. The performance of detection method was evaluated in the presence of 0,33 mg/mL bovine submaxillary gland mucin. A linear calibration curve of zanamivir was observed in the concentration range of 5 x 10-6 - 1 x 10-4 M (R2 = 0,990) with limit of detection (LOD) of 1,49 x 10-6 M for Au-BDD electrode. Linear calibration curve in the concentration range of 1 x 10-6 - 1 x 10-5 M (R2 = 0,998) with LOD 2,29 x 10-6 M was observed on AuNPs-BDD. The presence of NA caused the concentration of free zanamivir in the solution decreases and less zanamivir can be adsorbed at the electrode. As the result, the oxidation and the reduction peak currents of gold were increase. Linear calibration curve of NA was obtained in the concentration range of 0 ? 15 mU (R2 = 0,996), a LOD of 0,25 mU and %RSD of 1,18 % was achieved on Au-BDD electrode. Furthermore, linear calibration curve of NA on AuNPs-BDD electrode was in the concentration range of 0 ? 12 mU (R2 = 0,997) with LOD of 0,12 mU and %RSD of 2,49%. A comparable performance of NA detection was observed in the presence of mucin. Sensitivity of NA detection was decrease in magnetic beads system, the LOD of 0,64 mU was achieved in linear range of 0 ? 8 mU. Detection of NA on strip test system was successfully developed in linear range of 0 - 15 mU with LOD of 0,26 mU. NA detection in the presence of mucin was demonstrated on strip test system, the result suggested that the precision was decreased. Nevertheless the method is still promising for pharmaceutical or medical application."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
D2075
UI - Disertasi Membership  Universitas Indonesia Library
cover
Asman Kumik
"ABSTRAK
Peningkatan konsentrasi CO2 diatmosfer mengakibatkan permasalahan lingkungan sehingga konversi CO2 menjadi bahan kimia dan bahan bakar menarik untuk dikaji. Salah satu alternatif dalam daur ulang siklus karbon terbarukan yaitu dengan reduksi elektrokatalitik CO2 dapat dilakukan dalam kondisi ruang dan mudah dikontrol proses reaksinya dengan pengubahan potensial. Pada penelitian ini, boron-doped diamond dimodifikasi terlebih dahulu dengan AuNP, PdNP dan AuPdNP kemudian diaplikasikan untuk reduksi CO2 secara elektrokimia. Sebelum dilakukan perendaman dengan larutan nanopartikel, BDD dimodifikasi dengan larutan allilamina dibawah sinar UV selama 6 jam. Kemudian direndam dalam larutan koloid nanopartikel. Karakterisasi larutan nanopartikel dilakukan dengan UV-Vis dan TEM, sedangkan BDD termodifikasi dikarakterisasi dengan SEM EDS, XPS dan secara elektrokimia. Elektroreduksi CO2 dilakukan dalam sel dengan dua kompartemen dengan larutan elektrolit NaCl 0,1 M di dalam ruang katoda dan larutan Na2SO4 0,1 M di dalam ruang anoda. Potensial yang digunakan ialah -0,8 V, -0.9V, dan -1,1V vs Ag/AgCl dengan waktu reduksi selama 60 menit. Produk yang dihasilkan dikarakterisasi dengan GC, HPLC dan GC-MS. Efisiensi Faraday tertinggi dihasilkan oleh elektroda BDDN-AuPdNP sebesar 84,564 dan asam asetat sebagai salah satu produk.Kata kunci: Elektroreduksi CO2, nanopartikel emas palladium, boron-doped diamond, modifikasi permukaan.

ABSTRACT
The increase of CO2 concentrations in atmosphere can cause an environmental problem so CO2 conversion to chemicals and fuels become interesting to be investigated. One of the alternative in recycling renewable carbon cycles is electrocatlytic conversion of CO2 using the electrochemical method due to mild condition and easily controllable in term of reaction process by changing the potential value. In this study, boron doped diamond was previously modified with AuNP, PdNP and AuPdNP then applied for electrochemical reduction. Before modification with nanoparticle solutions, BDD was modified with allylamine under UV light for 6 hours. The nanoparticle solutions were characterized by UV Vis and TEM, while modified BDD was characterized by SEM EDS, XPS and electrochemical characterization. The electroreduction of CO2 was performed on two cell compartments using NaCl 0,1M in cathode and Na2SO4 in anode. The potentials used were 0.8 V, 0.9V, and 1.1V vs. Ag AgCl with a reduction time of 60 min. The resulting products were characterized by GC, HPLC and GC MS. The highest Faradic efficiency is mostly generated by BDDN AuPdNP electrode, approximately 84.564 and the only electrode form these experiments which had produced acetic acid.Keywords the electroreduction of CO2, gold palladium nanoparticle, boron doped diamond, surface modification."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
T50393
UI - Tesis Membership  Universitas Indonesia Library
cover
Evan Fairuz Hadi
"SARS-CoV-2 merupakan virus RNA penyebab COVID-19 yang telah menjadi pandemi dunia selama dua tahun terakhir. Hingga saat ini, metode deteksi RT-PCR menjadi metode terbaik dalam deteksi COVID-19. Namun mahalnya biaya reagen dan instrumentasi menyebabkan diperlukannya metode lain yang lebih murah dan praktis. Sementara itu Umifenovir (arbidol) merupakan senyawa elektroaktif yang dapat berinteraksi dengan spike glikoprotein SARS-CoV-2. Pada penelitian ini interaksi umifenovir dan glikoprotein S2 dipelajari dengan studi elektrokimia di permukaan elektroda boron-doped diamond (BDD). Sebelum dilakukan studi elektrokimia, dilakukan studi penambatan molekul dengan Homology Modelling dan Molecular Docking menggunakan umifenovir. Studi interaksi umivenofir terhadap glikoprotein S2 SARS CoV-2 menghasilkan affinity binding sebesar -6,1 kcal/mol. Sedangkan studi elektrokimia umifenovir menggunakan elektroda BDD pada rentang potensial dari (-0,8 V) hingga (+0,8 V) dan scan rate 50 mV/s menunjukkan korelasi linear pada rentang konsentrasi 10- 100 μM. Selanjutnya deteksi spike glikoprotein S2 SARS CoV-2 menggunakan kondisi optimum dengan 100 μM umifenovir dan 0,0025 μg/mL spike glikoprotein melalui perbandingan 20:1 menunjukkan nilai limit deteksi (LoD) dan limit kuantifikasi (LoQ) berturut-turut sebesar 0,001497 μg/mL dan 0,004991 μg/mL. Hasil studi menunjukkan bahwa ode deteksi yang dikembangkan dengan elektroda BDD dapat digunakan untuk sampel klinis SARS-CoV-2.

SARS-CoV-2 is RNA virus causing Covid-19 which has become the global pandemic in the last two years. To date, RT-PCR is the best method for Covid-19 detection. However, the costly chemical reagents and instruments for this method suggesting another cheaper and practical method is necessary. Meanwhile, umifenovir (arbidol) is an electroactive compound which can interact with the SARS-CoV-2 glicoprotein spike. In this research, umifenovir interaction with glicoprotein S2 is investigated through the electrochemical study on the electrode surface of boron-doped diamond (BDD). Prior to the electrochemical study, computational study using Homology Modelling dan Molecular Docking was performed for umifenovir. Affinity binding of -6.1 kcal/mol was obtained from the umivenofir against glicoprotein S2 SARS CoV-2. On the other hand, the electrochemical study on umifenovir using BDD electrode in the potential range of -0.8 V to +0.8 Vand scan rate of 50 mV/s shows a linear correltaion in the concentration range of 10-100 μM. Moreover, the detection of S2 SARS CoV-2 glicoprotein spike using the optimum condition of 100 μM umifenovir and 0.0025 μg/mL glicoprotein spike with 20:1 ratio shows the limit of detection (LoD) and limit of quantification (LoQ) are 0.001497 μg/mL and 0.004991 μg/mL, respectively. The results of this study reveal that the detection method developed with BDD electorde can be applied for the real samples of SARS-CoV-2."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hanif Mubarok
"ABSTRAK
Meningkatnya permintaan vanillin oleh industri yang mencapai 15000 ton/tahun mendorong peneliti untuk mengembangkan metode alternatif untuk sintesis vanillin. Selain ekstraksi dari vanilla alami, vanillin dapat disintesis dari bahan berbasis minyak dan produksi secara mikroba, yang membutuhkan biaya tinggi, metode berkelanjutan, dan langkah yang rumit. Pada penelitian ini vanillin disintesis dari isoeugenol dengan metode elektrokimia menggunakan elektroda Boron Doped Diamond (BDD) dan Platina dalam sel satu kompartemen. Kondisi optimum diperoleh dengan memvariasikan potensial oksidasi, pelarut, waktu elektrolisis, dan jumlah air. Sintesis vanillin dilakukan menggunakan teknik kronoamperometri dan diperoleh kondisi optimum pada sistem potensial 0.3 V (vs Ag/AgCl) dalam metanol selama 30 menit pada untuk elektroda BDD, dan 0.41 V (vs Ag/AgCl) dalam metanol selama 30 menit untuk elektroda Platina, keduanya dengan penambahan 1 mL air. Analisis dilakukan menggunakan HPLC dan GC dengan konversi 9.48% dan 4.11% untuk masing-masing kondisi optimum. Pada mekanisme yang diajukan, isoeugenol mengalami oksidasi gugus alil menjadi diol yang diikuti pemutusan oksidatif menjadi aldehid.
ABSTRAK
The increased demand on vanillin by industries up to 15000 tons/year encourage researcher to develop an alternative method in vanillin synthesize. Beside extraction from natural vanilla, vanillin can be synthesized from petroleum based material and microbial production which require high cost, consecutive method, and complicated steps. In this study, vanillin was synthesized from isoeugenol through electrochemical method using Boron Doped Diamond (BDD) and Platinum (Pt) electrode in one compartment cell. Optimum condition was obtained with varying the oxidation potential, solvents, time of electrolysis, and amount of water. The synthesis of vanillin was conducted using chronoamperometry technique, and optimum contidion was obtained at potential 0.3 V (vs Ag/AgCl) in methanol for 30 minutes at BDD electrode, and 0.41 V (vs Ag/AgCl) in methanol for 30 minutes at Pt electrode, both in 1 mL water addition respectively. Analysis was done using HPLC and GC/MS with conversion 9.48% and 4.11% for both optimum conditions. In the proposed mechanism, isoeugenol undergoes oxidation of allyl group into diol and followed by oxidative cleavage into aldehyde."
2016
S64944
UI - Skripsi Membership  Universitas Indonesia Library
cover
Habibah Wardah
"Pengembangan sensor BOD (Biochemical Oksigen Demand) dilakukan menggunakan biosensing khamir Rhodotorula mucilaginosa UICC Y-181 yang terimobilisasi dalam matriks gelatin dan alginat. BOD diukur sebagai jumlah oksigen yang digunakan oleh biosensing dalam selang waktu tertentu untuk mengoksidasi senyawa organik dalam larutan. Pada penelitian ini glukosa digunakan sebagai model senyawa organik. Kadar oksigen dalam larutan diukur menggunakan elektroda emas dan elektoda Boron-Doped Diamond termodifikasi nanopartikel emas sebagai elektroda kerja dengan teknik Multi Pulse Amperometry melalui reaksi reduksi oksigen pada -554 mV (vs Ag/AgCl).
Kurva kalibrasi linear diperoleh dari perubahan arus reduksi oksigen setelah selang waktu tunggu optimum 20 menit (ΔI = I0 ?I20) pada larutan glukosa dalam berbagai variasi konsentrasi (0,1 ? 0,9 mM) setelah larutan dijenuhkan dengan oksigen. Selain mikroorganisme terimobilisasi, mikroorganisme dalam keadaan bebas (free cell) juga digunakan sebagai pembanding. Regresi linier (R2 = 0,95 - 0,99) dapat diperoleh pada semua sensor BOD baik dengan mikroorganisme bebas maupun terimobilisasi. Tetapi sensitivitas sensor dengan mikroorganisme bebas umumnya lebih tinggi daripada keadaan terimobilisasi, walaupun kedapatulangan yang lebih baik umumnya diperoleh pada sensor dengan mikroorganisme terimobilisasi, terutama yang terimobilisasi dalam matriks gelatin.

The development of BOD sensor was conducted by using Rhodotorula mucilaginosa UICC Y-181 yeast imobilized in gelatine and alginate matrix as the biosensing agent. BOD was measured as oxygen amount used by the biosensing agent to oxidize organic compounds in solution. In this work, glucose was used as an organic compound model. Oxygen concentration in water was measured by using gold and gold nanoparticles-modified Boron-Doped Diamond electrodes with Multy Pulse Amperometry technique via oxygen reduction reaction at -554 mV (vs Ag/AgCl).
Linear calibration curves was performed at change of oxygen reduction current after an optimum waiting time of 20 min ΔI (I0 ?I20) to solutions with a various glucose concentrations (0.1 - 0.9 mM) after saturated by oxygen. Beside the use of immobilized microorganism, free cell of the microorganism was also used as a comparison. The linear regression (R2 = 0.95 ? 0.99) could be observed at all BOD sensors with the free and the immobilized cells. However, the sensitivity of the sensors with free cell were generally higher than that of the immobilized ones, although better reproducibility was shown at the sensors with immobilized microorganisms, especially which were immobilized in gelatine matrix.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
T31484
UI - Tesis Open  Universitas Indonesia Library
cover
Widhi Susanti
"ABSTRAK
Sel bahan bakar fuel cell adalah salah satu alternatif untuk menggantikan bahan bakar dari fosil. Fuel cell mengkonversi energi kimia bahan bakar fuel menjadi listrik, panas, dan air. Urea di dalam urin adalah komponen terbesar kedua setelah air. Ikatan nitrogen-hidrogen urea lebih mudah diputuskan bila dibandingkan dengan ikatan oksigen-hidrogen dalam air, kemudian dilepaskan gas hidrogen dan listrik dapat dihasilkan. Pada penelitian ini preparasi elektroda boron-doped diamond termodifikasi nikel Ni-BDD dilakukan dengan teknik elektrodeposisi dari larutan 1 mM Ni NO 3 dalam larutan buffer asetat diikuti pengulangan cyclic voltammetry CV dalam 1 M KOH. Elektroda ini kemudian dimanfaatkan untuk elektrokatalis oksidasi urea dalam urin untuk produksi energi listrik dalam fuel cell. Penggunaan Ni-BDD diharapkan meningkatkan aktivitas fuel cell. Performa elektrokatalis tersebut diamati dengan fuel cell urea/hidrogen peroksida H2O2 . Hasil menunjukan densitas daya rata-rata yang dapat dihasilkan selama satu jam pengukuran dalam suhu ruang adalah 72,2 mW cm-2 jika 0,33 mol L-1 urea dalam 0,01 mol L-1 KOH digunakan sebagai larutan anoda dan 2 mol L-1 H2O2 dalam 2 mol L-1 H2SO4 digunakan sebagai larutan katoda. Sedangkan penggunaan urin untuk menggantikan 0,33 mol L-1 urea menghasilkan densitas daya 22 mW cm-2.

ABSTRACT
Fuel cell is an alternative to replace the fossil fuels. Fuel Cell converts chemical energy of fuel into current, heat, and water. Urea in urine is the second largest component after water. The hydrogen nitrogen bonds in urea are more easily break than hydrogen oxygen bonds in water, then hydrogen gas is released and the electricity can be generated. In this work, nickel modified boron doped diamond Ni BDD electrode was prepared by electrodeposition was performed from 1 mM Ni NO 3 solution in acetate buffer solution followed by repetitive of cyclic voltammetry CV in 1 M KOH. The electrode used for electrocatalytic urea oxidation in urine for electrical energy production in the fuel cell. The use of Ni BDD is expected to increase fuel cell activity. The electrocatalyst perfomance was observed by urea hydrogen peroxide H2O2 fuel cell. The result show the average power density that can be produced during one hour of mesurement in room temperature was 72,2 mW cm 2 when a solution of 0,33 mol L 1 urea in 0,01 mol L 1 KOH was used as anolyte and 2 mol L 1 H2O2 in 2 mol L 1 H2SO4 used as catholyte. Whereas, replacing 0,33 mol L 1 urea by urine produced power density was 22 mW cm 2."
2017
S69235
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>