Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 131622 dokumen yang sesuai dengan query
cover
Harahap, Sefty Aryani
"ABSTRAK
Background: Currently, there has been a lot of bulk fill resin, such as bulk fill giomer which has S-PRG filler particles and other bulk fill resin composites which have their own uniqueness. Polymerization with irradiance

ABSTRACT
Latar Belakang Saat ini telah banyak berkembang komposit resin bulk fill, seperti giomer bulk fill yang memiliki partikel filler S PRG serta komposit resin bulk fill lain yang memiliki keunikan tersendiri. Polimerisasi dengan LED irradiansi "
2017
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Rebecca Grace Agustina
"Penelitian ini bertujuan untuk mengevaluasi pengaruh durasi penyinaran terhadap kekuatan tarik diametral resin komposit bulk-fill. Enam puluh spesimen Tetric N-Ceram Bulk-Fill ketebalan 3 mm dan diameter 6 mm; warna IVA dan IVW dibagi ke dalam 3 kelompok berdasarkan durasi penyinaran 10 detik, 15 detik, dan 20 detik untuk setiap warna. Spesimen dipolimerisasi dengan LED curing unit Bluephase Style, 1.280 mW/cm2 dan diuji kekuatan tarik diametralnya menggunakan uji statistik Universal Testing Machine. Data yang diperoleh dianalisis menggunakan One-Way ANOVA dan Post-Hoc Tukey HSD. Hasil menunjukkan adanya perbedaan bermakna.

This study was conducted to evaluate the influence of different exposure time and bulk fill composite shade on its diametral tensile strength. Sixty disc shaped specimens of Tetric N Ceram Bulk Fill 3 mm of thickness x 6 mm of diameter shade IVA and IVW were divided into 3 subgroups for each shade according to exposure times 10 s, 15 s, and 20 s . All specimens were polymerized using LED curing unit Bluephase Style, 1.280 mW cm2 and tested using Universal Testing Machine to determine its diametral tensile strength. Data were statistically analyzed using One Way ANOVA dan Post Hoc Tukey test. The result showed a significant differences in all groups."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mesy
"Latar belakang: Resin komposit Bulk-fill merupakan material tumpatan gigi yang dapat digunakan pada kavitas gigi posterior sedalam 4-5mm dengan satu kali penyinaran. Durasi penyinaran dan metode penyinaran mempengaruhi derajat polimerisasi dari suatu material tumpatan gigi. Sehingga derajat polimerisasi akan mempengaruhi sifat mekanik salah satunya adalah kuat tarik diametral suatu material resin komposit Bulk-fill. Tujuan: Untuk mengetahui kuat tarik diametral resin komposit Bulk-fill yang disinar menggunakan Light Curing Unit eksperimental metode penyinaran pulsa dan Light Curing Unit komersial metode penyinaran kontinu selama 5 detik, 10 detik dan 20 detik. Metode: Enam puluh spesimen resin komposit Bulk-fill (diameter 6mm dan ketebalan 3mm) yang dibagi menjadi 2 kelompok metode penyinaran (pulsa dan kontinu) dan 3 kelompok durasi penyinaran (5 detik, 10 detik, 20 detik) dan direndam didalam 5ml akuades kemudian disimpan dalam inkubator 37oC selama 24 jam. Spesimen lalu dilakukan uji kuat tarik diametral menggunakan Universal Testing Machine dengan beban uji sebesar 250kgFdengan crosshead speed 0,5 mm/menit Hasil: Terdapat peningkatan nilai kuat tarik diametral selama 5 detik, 10 detik dan 20 detik pada metode penyinaran pulsa (53,90±8,53 MPa, 54,94±7,68 MPa, 56,18±6,99 MPa) dan metode penyinaran kontinu (53,26±5,78 MPa, 56,40±5,15 MPa, 57,17±5,70 MPa). Uji One-Way ANOVA menunjukkan tidak terdapat perbedaan yang bermakna (p>0,05) antara durasi penyinaran dan juga metode penyinaran. Kesimpulan: Kuat tarik diametral pada metode penyinaran pulsa memiliki nilai yang lebih rendah dibandingkan dengan metode penyinaran kontinu.

in posterior tooth cavities as deep as 4-5mm with one curing. The duration and method of curing affect the degree of polymerization of a tooth filling material. Therefore, the degree of polymerization will affect the mechanical properties, one of which is the diametral tensile strength of a Bulk-fill composite resin material. Objective: To determine the diametral tensile strength of Bulk-fill composite resins cured using the experimental Light Curing Unit pulses curing method and commercial Light Curing Units with continuous curing method for 5 seconds, 10 seconds and 20 seconds. Method: Sixty Bulk-fill composite resin specimens (6mm diameter and 3mm thickness) were divided into 2 groups of curing methods (pulses and continuous) and 3 groups of curing duration (5 seconds, 10 seconds, 20 seconds) then immersed in 5 ml distilled water and stored in 37oC incubator for 24 hours. Specimens were then tested with diametral tensile strength using a Universal Testing Machine with a test load of 5 kN with a crosshead speed of 0.5 mm/minute. Result: There was an increase in diametral tensile strength values for 5 seconds, 10 seconds, and 20 seconds in the pulse curing method (53.90 ± 8.53 MPa, 54.94 ± 7.68 MPa, 56.18 ± 6.99 MPa) and also an increase in the continuous curing method (53.26 ± 5.78 MPa, 56.40 ± 5.15 MPa, 57.17 ± 5.70 MPa). One-Way ANOVA test showed no significant difference (p> 0.05) between each duration and method of curing. Conclusion: The diametral tensile strength of the pulse curing method has a lower value compared to the continuous irradiation method."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rivandy Holil
"Latar Belakang: Dalam dunia kedokteran gigi, terdapat banyak pilihan material restoratif yang dapat digunakan, salah satunya yaitu resin komposit. Seiring dengan perkembangan teknologi, para peneliti berhasil mengembangakan resin komposit baru yaitu Bulk-Fill. Sebagai contoh adalah resin komposit Giomer Bulk-Fill yang memiliki berbagai sifat seperti sifat mekanik, fisis dan biologis. Namun, belum ada penelitian pada resin komposit Giomer Bulk-Fill yang secara spesifik menguji nilai kekuatan tarik diametral yang merupakan salah satu sifat mekanik material restoratif.
Tujuan Penelitian: Penelitian ini bertujuan untuk mengetahui pengaruh lama perendaman 1, 24, dan 72 jam serta perbedaan nilai pH saliva buatan 7; 5,5; dan 4,5 terhadap kekuatan tarik diametral resin komposit Giomer Bulk-Fill.
Metode: Penelitian eksperimental laboratorik dengan menggunakan 90 spesimen berbentuk silindris pejal dengan diameter 6 mm dan tinggi 3 mm yang diuji menggunakan Universal Testing Machine (Shimadzu AGS-X 5kN, Japan) dan dibagi ke dalam 3 kelompok pH larutan saliva buatan yaitu 7; 5,5; dan 4,5; serta 3 kelompok lama perendaman yaitu 1, 24, dan 72 jam.
Hasil: Hasil pengujian menggunakan uji One-way ANOVA menunjukkan adanya perbedaan bermakna pada spesimen-spesimen yang digunakan (p<0,05). Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 7, hasil rerata kekuatan tarik diametral pada perendaman selama 1 jam adalah sebesar 36,7 ± 2,7 MPa. Kemudian mengalami penurunan setelah perendaman 24 jam dengan rerata nilai kekuatan tarik diametralnya sebesar 35,2 ± 2,2 MPa dan meningkat kembali setelah perendaman 72 jam dengan hasil rerata kekuatan tarik diametralnya sebesar 40,1 ± 3,6 MPa. Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 4,5, pada perendaman selama 1 jam hasil rerata kekuatan tarik diametralnya sebesar 33,6 ± 2,4 MPa. Kemudian setelah perendaman 24 jam dan 72 jam meningkat menjadi 42,6 ± 2 MPa dan 44,2 ± 2,8 MPa. Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 5,5, hasil rerata kekuatan tarik diametral setelah perendaman selama 1 jam adalah sebesar 34 ± 2,4 MPa. Namun, terjadi perbedaan jika dibandingkan dengan kelompok pH 4,5 yaitu pada kelompok dengan pH 5,5 pada lama perendaman 24 jam terjadi peningkatan yaitu sebesar 44,7 ± 2,8 MPa kemudian menurun setelah perendaman 72 jam dengan nilai rerata sebesar 39 ± 3,3 MPa.
Kesimpulan: Nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill tidak dipengaruhi oleh pH saliva buatan 4,5; 5,5; dan 7 yang digunakan di dalam penelitian ini. Nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill yang direndam selama 1, 24, dan 72 jam di dalam saliva buatan dengan pH 4,5; 5,5; dan 7 secara umum mengalami peningkatan sehingga lama perendaman dalam penelitian ini mempengaruhi nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill.

Background: In the world of dentistry, there are many choices of restorative materials that can be used, one of them is composite resin. Along with the development of technology, the researchers succeeded in developing a new composite resin called Bulk-Fill. One example is Giomer Bulk-Fill composite resin which has various properties such as mechanical, physical and biological properties. However, there is no research on Giomer Bulk-Fill composite resin which specifically tests the value of diametral tensile strength which is one of the mechanical properties of restorative material.
Objective: This study aims to determine the effect of immersion time and the difference in pH value 7; 5,5; and 4,5 of the artificial saliva solution on the value of diametral tensile strength of Giomer Bulk-Fill composite resin.
Method: Laboratory experimental research using 90 solid cylindrical specimens with a diameter of 6 mm and a height of 3 mm which were tested using Universal Testing Machine (Shimadzu AGS-X 5kN, Japan) and were divided into 3 groups pH of artificial saliva solution (7; 5.5; and 4.5) and 3 groups of immersion periods (1, 24 and 72 hours).
Results: The test results using the One-way ANOVA test showed significant differences in the specimens used (p <0.05). In the group of specimens which were immersed in artificial saliva solution with pH 7, the results of the average diametral tensile strength at immersion for 1 hour were 36.7 ± 2.7 MPa. Then it decreased for 24 hours immersed time with a mean value of diametral tensile strength of 35.2 ± 2.2 and increased again at 72 hours immersed time with an average value of diametral tensile strength 40.1 ± 3.6 MPa. In the group of specimens which were immersed in artificial saliva solution with pH 4.5, at immersion for 1 hour the average value of diametral tensile strength was 33.6 ± 2.4 MPa. Then in 24-hour and 72-hour immersion, it increased to 42.6 ± 2 MPa and 44.2 ± 2.8 MPa. In the group of specimens immersed in artificial saliva solution with a pH of 5.5, the average value of diametral tensile strength for 1 hour was 34 ± 2.4 MPa. However, there was a difference when compared to the pH 4.5 group, which was in the group with a pH of 5.5 in the 24-hour immersion period, the value increase for 44.7 ± 2.8 MPa and then decreased for 72 hours of immersion with an average value of 39 ± 3.3 MPa.
Conclusion: The value of diametral tensile strength of Giomer Bulk-Fill composite resin is not affected by pH of artificial saliva 4.5; 5.5; and 7 that used in this study. The value of diametral tensile strength of Giomer Bulk-Fill composite resin, which is immersed for 1, 24, and 72 hours in artificial saliva with pH 4.5; 5.5 and 7 generally increased so that the immersion time in this study affected the diametral tensile strength of Giomer Bulk-Fill composite resin.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Konita Nur Khasanah
"Tujuan penelitian ini untuk mengetahui pengaruh penggunaan sumber sinar berbeda terhadap kekuatan tarik diametral resin komposit bulk-fill. Resin komposit bulk-fill Tetric N-Ceram Bulk Fill dibuat sebanyak 20 spesimen berbentuk lempeng dengan diameter 6 mm dan tebal 3 mm. Spesimen dibagi menjadi dua kelompok yaitu kelompok yang disinari dengan sumber sinar QTH dan sumber sinar LED. Uji kekuatan tarik diametral dilakukan dengan menggunakan Universal Testing Machine. Hasil penelitian menunjukkan nilai rerata kekuatan tarik diametral resin komposit bulk-fill yang disinari sumber sinar QTH dan LED sebesar 38.62 2.34 dan 42.02 3.21. Hasil uji independent sample T menunjukkan nilai rerata pada kedua kelompok berbeda bermakna.

This study aimed to evaluate the effect of using different light sources on the diametral tensile strength of bulk fill resin composite. Bulk fill resin composite Tetric N Ceram Bulk Fill was used to make of 20 disc shape specimens with 6 mm in diameter and 3 mm in thickness. Specimens were divided into two groups, the two groups were polymerized with using QTH and LED light source curing unit. Diametral tensile strength test was conducted by using a Universal Testing Machine Shimadzu, Japan. The results showed that diametral tensile strength mean value of bulk fill resin composite that were cured with QTH and LED light source were 38.62 2.34 and 42.02 3.21 MPa respectively. Independent sample t test results showed that the mean value of the two groups was significantly different."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dela Medina
"Penelitian ini bertujuan mengevaluasi pengaruh warna terhadap kekuatan tarik diametral resin komposit bulk-fill. Tiga kelompok spesimen resin komposit bulkfill dari Tetric N-Ceram Bulk-fill (Ivoclar Vivadent, Lichenstein) warna IVA, IVB, dan IVW dipolimerisasi menggunakan LED light curing unit. Uji kekuatan tarik diametral dilakukan menggunakan Universal Testing Machine. Hasil menunjukkan bahwa kekuatan tarik diametral resin komposit bulk-fill warna IVA, IVB, dan IVW, secara berurutan adalah sebesar 41,730±3,729 MPa; 42,573±3,472 MPa dan 45,402±2,038 MPa. Analisa statistik Post-hoc Test menunjukkan adanya perbedaan bermakna (p<0,05) antara kekuatan tarik diametral kelompok warna IVA dengan IVW. Dapat disimpulkan, warna resin komposit bulk-fill dapat mempengaruhi kekuatan tarik diametralnya.

This study aimed to evaluate the influence of color shades on diametral tensile strength of bulk-fill composites. Tetric N-Ceram Bulk-fill in color shade IVA, IVB, and IVW were polymerized using LED light curing unit. Universal Testing Machine was used to determined the diametral tensile strength (DTS). The value of specimen color shade IVA, IVB, and IVW are 41.730±3.729 MPa; 42.573±3.472 MPa and 45.402±2.038 MPa, respectively. Post-hoc test revealed that DTS between bulk-fill composites in color shade IVA and IVW is significantly different (p<0,05). It can be concluded that diametral tensile strength of bulk-fill composite could be affected by its color shades"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2015
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Napitupulu, Elizhabet
"Tujuan penelitian ini adalah untuk mengetahui pengaruh jarak sumber sinar Light Emitting Diode (LED) terhadap kekuatan tarik diametral resin komposit bulk-fill. Resin komposit bulk-fill Tetric® N-Ceram Bulk-Fill, shade IVA (setara dengan warna VITA A2-A3) dibuat menjadi 30 spesimen berbentuk silinder dengan ukuran tebal 3 mm dan diameter 6 mm. Spesimen dibagi menjadi 3 kelompok variasi jarak penyinaran, yaitu 0 mm, 3 mm dan 5 mm. Penyinaran menggunakan LED Light Curing Unit Bluephase® Style (Ivoclar-Vivadent, Liechtenstein) dengan durasi penyinaran selama 10 detik sesuai instruksi pabrik. Data dianalisis secara statistik menggunakan metode ANOVA satu arah. Hasil analisis tidak menunjukkan perbedaan bermakna (p>0,05) pada semua kelompok. Jarak sumber sinar LED ≤ 5 mm tidak memberikan pengaruh yang signifikan terhadap kekuatan tarik diametral resin komposit bulk-fill.

This study aimed to evaluate the effect of LED light source distance on diametral tensile strength of bulk-fill composite restorative material. Bulk-fill composite Tetric® N-Ceram Bulk-Fill, shade IVA (equal to VITA shade A2-A3) was formed into 30 cylindrical specimens with 3 mm in thickness and 6 mm in diameter. Specimens were divided into 3 groups with various curing distance: 0 mm, 3 mm and 5 mm. All groups were polymerized by LED Light Curing Unit Bluephase® Style (Ivoclar-Vivadent, Liechtenstein) for 10 seconds based on manufacturer’s instruction. Data were statistically analyzed by one-way ANOVA The result showed insignificant differences in all groups (p>0,05). LED light source distance ≤ 5 mm was not significantly affected the diametral tensile strength of bulk-fill composite."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2015
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Putri Risky Auliana
"Latar Belakang : Pada penelitian sebelumnya, iradiasi menggunakan iradiasi pulsa LCU cenderung diikuti dengan suhu cahaya yang relatif rendah sehingga aman untuk pulpa gigi dan telah diaplikasikan untuk polimerisasi resin komposit nanofil dalam waktu 20 detik. berdenyut melawan kekuatan kompresi selama 5, 10, 20 detik. Metode : 60 spesimen resin komposit isi curah silinder diameter 3 mm dan tebal 6 mm, diiradiasi dengan LCU eksperimental iradiasi pulsa dan LCU komersial iradiasi kontinyu sebagai kontrol selama 5, 10, 20 detik. Kemudian direndam dengan air suling selama 24 jam. Spesimen kemudian diuji kuat tekannya menggunakan mesin uji universal (Shimadzu AGS-X 5kN, Jepang) dengan kecepatan crosshead 0,5m/s. Hasil: terjadi peningkatan kuat tekan resin komposit isian curah iradiasi
dengan LCU eksperimental selama 5, 10, 20 detik, memiliki hasil berturut-turut sekitar 209,43 hingga 241,80 MPa. Kemudian dengan iradiasi kontinyu LCU komersial memiliki hasil berturut-turut sekitar 210,69 hingga 261,72 MPa. Analisis one-way ANOVA dan post hoc bonferroni menunjukkan hasil yang tidak berbeda nyata (p>0,05) nilai kuat tekan antara kedua metode penyinaran pada lama waktu yang sama. Tidak terdapat perbedaan yang signifikan pada masing-masing metode iradiasi pada durasi yang berbeda. Sementara itu, mendeteksi perbedaan yang signifikan (p<0,05) pada kekuatan tekan resin komposit pengisian curah dengan penyinaran antara 5 dan 10 detik dan 5 dan 20 detik dengan metode penyinaran kontinu. Kesimpulan: kuat tekan resin komposit bulk fill baik dengan iradiasi pulsa maupun kontinyu selama 5, 10, 20 detik meningkat dengan bertambahnya lama iradiasi, dan iradiasi menggunakan metode pulsa dan
kuat tekan kontinyu menghasilkan resin komposit bulk fill yang tidak berbeda nyata.
Background : In previous studies, irradiation using LCU pulse irradiation tends to be followed by a relatively low light temperature so that it is safe for dental pulp and has been applied to polymerize nanofil composite resins within 20 seconds. pulse against the force of compression for 5, 10, 20 seconds. Methods : 60 specimens of cylindrical bulk-filled composite resin with a diameter of 3 mm and a thickness of 6 mm, were irradiated with pulse irradiation experimental LCU and continuous irradiated commercial LCU as control for 5, 10, 20 seconds. Then soaked with distilled water for 24 hours. The specimens were then tested for compressive strength using a universal testing machine (Shimadzu AGS-X 5kN, Japan) with a crosshead speed of 0.5m/s. Result: there was an increase in the compressive strength of the irradiated bulk filled composite resin with the experimental LCU for 5, 10, 20 s, had successive yields of about 209.43 to 241.80 MPa. Then with continuous irradiation commercial LCU has successive yields of about 210.69 to 261.72 MPa. One-way ANOVA and post hoc bonferroni analysis showed that the results were not significantly different (p>0.05) in the compressive strength between the two irradiation methods at the same time. There was no significant difference in each irradiation method at different durations. Meanwhile, detecting a significant difference (p<0.05) in the compressive strength of composite resin bulk filling with irradiation between 5 and 10 seconds and 5 and 20 seconds with the continuous irradiation method. Conclusion: the compressive strength of bulk fill composite resins both with pulse and continuous irradiation for 5, 10, 20 seconds increased with increasing irradiation time, and irradiation using pulse and pulse irradiation methods continuous compressive strength resulted in bulk fill composite resin which was not significantly different."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mutiara Medikasari
"Penelitian ini bertujuan untuk mengetahui pengaruh ketebalan komposit resin dan jarak penyinaran terhadap kekuatan tarik diametral komposit resin serat pendek KRSP . Empat puluh spesimen KRSP EverX PosteriorTM berbentuk lempengan dengan ketebalan 3 dan 4 mm, diameter 6 mm n=20 dibagi menjadi dua kelompok dengan jarak penyinaran 2 dan 4 mm n=10 . Spesimen dipolimerisasi menggunakan LED curing unit, iradiansi 800 mW/cm2 selama 20 detik. Spesimen diuji menggunakan Universal Testing Machine 250 kgf, 0,5 mm/menit untuk mendapatkan nilai kekuatan tarik diametral. Hasil uji statistik One-Way ANOVA dan post-hoc LSD, kekuatan tarik diametral menurun signifikan pada kelompok dengan ketebalan KRSP 4 mm dan jarak penyinaran 4 mm. Disimpulkan bahwa ketebalan KRSP dan jarak penyinaran dapat mempengaruhi nilai kekuatan tarik diametral.

The aim of this study is to analyze the effect of short fiber reinforced resin composite SFRC thickness and light curing distance on diametral tensile strength. Forty disc shaped specimens of SFRC EverX PosteriorTM with 3 and 4 mm of resin composite thickness, 6 mm of diameter n 20 were divided into two different light curing distance groups 2 and 4 mm n 10 . All Specimens were polymerized using LED curing unit, irradiance 800 mW cm2 for 20 s. Specimens were tested using Universal Testing Machine 250 kgf, 0,5 mm menit to determine its diametral tensile strength. The result from One Way ANOVA and post hoc LSD statistical test, diametral tensile strength of 4 mm SFRC thickness with 4 mm light curing distance group has significantly decrease. It was concluded that both SFRC thickness and light curing distance has significant effect on the diametral tensile strength."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kiemas Muhammad Naufal Elsinaz
"ABSTRAK
Penelitian ini bertujuan untuk mengetahui pengaruh jarak penyinaran terhadap kekuatan tarik diametral dari material restorasi resin komposit alkasit. Tigapuluh dua spesimen material restorasi resin komposit alkasit Cention-N, Ivoclar-Vivadent, Liechtenstein berbentuk lempengan dengan ketebalan 3 mm dan diameter 6 mm n=32 dibagi menjadi dua kelompok dengan jarak penyinaran 0 dan 2 mm n=16 . Spesimen dipolimerisasi menggunakan LED curing unit, iradiansi 800 mW/cm2 selama 30 detik. Spesimen diuji menggunakan Universa Mechanicall Testing Machine 250 kgf, 0,5 mm/menit, Shimadzu, Japan untuk mendapatkan nilai kekuatan tarik diametral. Hasil uji statistik Independent Sample T-Test menunjukkan bahwa kekuatan tarik diametral menurun namun tidak signifikan terutama pada kelompok dengan jarak penyinaran 2 mm. Disimpulkan bahwa jarak penyinaran dapat mempengaruhi nilai kekuatan tarik diametral.

ABSTRACT
The aim of this study is to analyze the effect of light curing distance on diametral tensile strength of alkasite composite resin restoration material. Thirty two disc shaped specimens of alkasite composite restoration material Cention N, Ivoclar Vivadent, Liechtenstein with 3 mm thickness and 6 mm of diameter n 32 were divided into two different light curing distance groups 0 and 2 mm n 16 . All Specimens were polymerized using LED curing unit, irradiance 800 mW cm2 for 30 s. Specimens were tested using Universal Mechanical Testing Machine 250 kgf, 0,5 mm menit to determine its diametral tensile strength. The statistical results from Independent Sample T Test, showed that diametral tensile strength of 2 mm light curing distance group were decreased, but not significantly .It was concluded that light curing distance has effect on the diametral tensile strength of composite resin alkasite material."
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>