Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 142246 dokumen yang sesuai dengan query
cover
Lastadhi Aufar
"ABSTRACT
Helium is an abundant material with unique properties such as noble gas properties and very light compound. With many industrial and research purpose, Helium demand in the global market is rising. Natural gas is the richest source of Helium that can be extracted, with only 0.1 2 composition in the natural gas. This concentration of helium in the natural gas require an energy intensive process such as the use of low temperature distillation although some new emerging technologies such as membrane and adsorption technologies. Evaluation process using conventional two stage distillation column to recover helium and LNG is assessed and analysed on this paper to see if the project is feasible. The process design of distillation column simulated in Aspen HYSYS to assess the energy correlated in each equipment and their parameters studies affecting the production. With the assumption of production specification are out of the context, the helium extraction process requires significant amount of cooling energy with high economic capital. This comes to the fact with the process operation operates in 100 to almost 200oC for refrigeration process also equipped with expensive equipment such as distillation columns and heat exchangers.

ABSTRAK
Helium merupakan unsur yang berlimpah di alam semesta dengan berbagai sifat unik seperti gas mulia dan berat jenis yang sangat ringan. Dengan berbagai fungsi di industri maupun fungsi akademis, kebutuhan gas helium di pasar dunia menunjukan trend meningkat. Gas alam merupakan sumber utama dari Helium yang menunjukan sumber yang layak, dengan konsentrasi hanya 0.1 - 2 fraksi di gas alam sudah dapat dianggap menjadi gas alam yang kaya akan Helium. Oleh karena itu, extraksi helium dari gas alam membutuhkan operasi energi yang tinggi seperti penggunaan kolom distilasi pada suhu rendah, meskipun sudah terdapat teknologi terbaru seperti penggunaan membran dan teknologi absorbsi. Evaluasi menggunakan kolom distilasi dua tahap pada suhu rendah akan diperdalami guna memberikan model tersebut memberikan kelayakan dalam mengekstraksi Helium. Model ini disimulasikan dengan Aspen HYSYS dalam mengevaluasi konsumpsi energi dari sistem pada setiap peralatan dan juga mempelajari variabel yang mempengaruhi dalam operasi. Dengan asumsi pengkondisian pada produk diluar dari cakupan, ekstraksi helium menggunakan energi pendingin dengan jumlah yang signifikan dan juga harga capital yang tinggi. Ini disebabkan dengan fakta operasi dari simulasi dilakukan pada suhu rentang -100oC sampai dengan -200oC untuk merefrigerasi gas alam dan juga penggunaan peralatan yang menarik biaya besar seperti kolom distilasi dan beberapa alat penukar panas."
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dedeng Rahmat
"Dalam aplikasinya di bidang industri, sistem refrigerasi tunggal dan bertingkat tidak mampu untuk mengatasi perbedaan yang cukup besar antara kalor yang akan diserap dengan kalor yang akan dibuang, namun, tidak demikian dengan sistem cascade. Penelitian dengan alat yang sederhana yang telah dilakukan sebelumnya dengan menggunakan refrigeran alami telah menawarkan peluang yang baik.
Skripsi ini membahas tentang pengujian sistem cascade dengan menggunakan dua macam refrigeran sebagai variasi di sisi bagian HS, sedangkan pada bagian LS, digunakan campuran refrigeran alami R170/R744. Pengujian dilakukan dengan tiga cara, yaitu : memvariasikan komposisi massa campuran R170/R744, memvariasikan bukaan katup ekspansion LS, serta memvariasikan jenis refrigeran pada sisi bagian HS. Temperatur evaporasi terrendah yang bisa dicapai oleh sistem ini adalah -69,7°C dengan COP sebesar 1,88. Dengan kondisi 700g R22 pada sisi bagian HS dan 100g R170 pada sisi bagian LS

In many industrial applications, single stage and multi stage refrigeration systems fail to widen the gap between heat source and heat sink temperatures and now cascade system appear to be the best alternative. Modest reserch, in the past, has been done in cascade system based on natural refrigerants thereby offering good potential for research.
In this paper, a cascaded system for simultenous heating and cooling with a R22 and R290 based high-stage (HS) cycle and mixed R170/R744 based low-stage (LS) cycle for simultenous refrigeration and heating application has been analyzed. To facilate prediction of optimum performance parameter, performance trends with variation in fraction mass of R170/R744, variation in flow rate of ekspansion valve of LS, and variation refrigerant of HS have been presented. The lowest temperature reached in -69,7°C with COP 1,81. 700g of R22 (HS) and 100g of R170 (LS)
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50736
UI - Skripsi Open  Universitas Indonesia Library
cover
Luthfianto Iedar Budiyono
Depok: Fakultas Teknik Universitas Indonesia, 2011
S50881
UI - Skripsi Open  Universitas Indonesia Library
cover
Rifky Tri Wahyu Rosadi
"Dalam dunia pengobatan dan penelitian biomedis kebutuhan akan ruang pendingin yang dapat mencapai temperatur sangat rendah yaitu -80°C sangat dimintai karena dengan tenperatur -80_C ini spesimen biomedis tidak mudah rusak, aplikasinya di bidang industri sistem refrigasi tunggal dan bertingkat tidak dapat mengatasi perbedaan yang cukup besar antara kalor yang akan diserap dan kalor yang akan dibuang akan tetapi berbeda dengan sistem refrigasi cascade. Penelitian yang dilakukan menggunakan alat yang sederhana dengan refrigeran alami ini memberikan peluang yang baik. Skripsi ini membahas mengenai pengujian sistem refrigerasi cascade dengan menggunakan refrigeran hidrokarbon pada bagian sirkuit temperatur tinggi dan refrigeran campuran R744 dengan R170 pada sirkuit temperatur rendah. Pengujian dilakukan dengan menggunakan propane sebagai refrigeran pada temperatur tinggi dan variasi komposisi masa pada sirkuit temperatur rendah untuk mencari komposisi optimum campuran R744 dengan R170. Temperatur evaporasi terendah yg dicapai pada sirkuit temperatur rendah ini adalah -94.8°C dengan refrigeran CO2 murni akan tetapi temperatur tersebut tidak stabil, sedangkan temperatur stabil -77.95°C dicapai oleh refrigeran ethane murni dengan COP 0.77. Untuk komposisi campuran COP yang didapat sebesar 0.58 dengan komposisi 60% R744 dan 40% R170.

In the world of biomedical the need of cold storage that can achieve temperature of -80°C is wanted because with that temperature biomedical specimen can not easily broken, in industrial application single stage and multi stage refrigeration system can not overcome the gap between the heat that will be absorb and the heat that will be release but it is different with the cascade system. The experiment that is conduct with simple cascade system and the use of natural refrigerants make the cascade system appear to be the best alternative. This paper will explain about the cascade system that will use a hidrocarbon on High Stage and blend refrigerant between R744 and R170 on Low Stage. The experimant is conduct with propane refrigerant in the high Stage and variation of blend refrigerant between R744 and R170, the use of pure CO2 and the use of pure etahne. The lowest temperature that can be reached is -94.8°C with pure CO2 but the temperature is unstable and the stable temperature is achieve by pure ethane -77.95°C with the COP 0.77. For the blend composistion the highest COP is 0.58 with 60%R744 an 40%R170."
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50789
UI - Skripsi Open  Universitas Indonesia Library
cover
Lasman Saputra
"Dalam pengobatan dan penelitian biomedis diperlukan cold storage yang dapat mencapai temperatur -8°C dan untuk mencapai temperatur rendah tersebut digunakan sistem refrigerasi cascade. Selama ini sirkuit temperatur rendah menggunakan sistem refrigerasi cascade dan menggunakan refrigeran yang mengandung zat perusak ozon atau penyebab pemanasan global Karena itu, diperlukan alternatif refrigeran alamiah, yang salah satunya adalah karbondioksida Namun, tingginya tekanan dan temperatur triple menghalangi penggunaan karbondioksida untuk temperatur rendah Salah satu solusinya adalah dengan mencampur karbondioksida dengan hidrokarbon(propane) untuk itu pengujian ini dilakukan dengan memvariasikan komposisi massa dari kedua campuran. Dari hasil pengujian didapati temperature evaporasi terendah terjadi pada temperature - 72 dengan komposisi massa R744/R290 sebesar 60 : 40 dengan daya pemakaian listrik terbesar pada komposisi 100 : 0 sebesar 1006 watt.

In medical and biomedical research that is needed cold storage temperature can reach 80°C, and to achieve such a low temperature cascade refrigeration system is used. This circuit during low-temperature cascade refrigeration system using refrigerant-containing substances damaging the ozone or global warming cause, therefore, necessary alternative natural refrigerant, one of which is carbon dioxide [However, the high pressure and temperature triple carbon dioxide to prevent the use of low temperature one the solution is to mix carbon dioxide with hydrocarbons (propane) for this test was done by varying the composition of the mass of the two mixtures. From the test results found the lowest temperature evaporation occurs at temperatures of -72 with R744/R290 mass composition of 60: 40 with the largest electric power consumption on the composition 100: 0 for 1011 watts."
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50780
UI - Skripsi Open  Universitas Indonesia Library
cover
Sianturi, David Fernando
"Pabrik es mini yang bisa di bawa kemana saja merupakan salah satu solusi untuk ketersediaan es bagi nelayan di daerah-daerah terpencil. Yang sangat diperlukan oleh nelayan sebagai salah satu cara untuk meningkatkan kualitas kesegaran ikan dengan pembekuan. Sehingga mempunyai nilai jual yang lebih tinggi. Mini Ice Plant yang akan digunakan memakai sistem refrigerasi direct expansion dengan refrigeran yang digunakan adalah R-22. Untuk sistem kompresor yang akan digunakan adalah sistem paralel 3 kompresor bekerja berdasarkan kapasitas. Kapasitas pendinginan untuk membekukan 1,5 ton air yaitu 10,33 kW. Perancangan dan pemilihan, baik kompresor ataupun kondensor dengan menggunakan software dan disesuaikan dengan kondisi pasar yang ada. Komponen aksesoris disesuaikan dengan kapasitas pendinginan, kompresor dan kondensor. Untuk kompresor didapatkan kompresor berkapasitas 2½ pk, 2 kompresor 1½ pk. Sedangkan untuk kondensor berkapasitas 16,12 kW.

Portable mini ice plant is one solution of ice availability for fisherman in remote area. Which needed by fisherman to increase the quality of fish freshness by freezing. So there's an added value. MINI ICE PLANT will use direct expansion refrigeration system. Refrigerant used is R-22. System used in compressor is paralel using 3 compressor based on capacity. Cooling capacity to freeze 1,5 ton water is 10,33 kW. Design and actual selection, both compresor and condenser done by software and compare to market availability. Selection accessories based on cooling capacity, compressor and condenser. Refrigeration system MINI ICE PLANT can be used and works based on calculation and selection. For compressor selection, using 2½ pk, 2 kompresor 1½ pk. Though, for condenser, using 16,12 kW condenser."
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50954
UI - Skripsi Open  Universitas Indonesia Library
cover
Christian
"Dalam aplikasinya di bidang industri, sistem refrigerasi tunggal dan bertingkat tidak mampu untuk mengatasi perbedaan yang cukup besar antara kalor yang akan diserap dengan kalor yang akan dibuang, namun, tidak demikian dengan system cascade. Penelitian dengan alat yang sederhana yang dilakukan sebelumnya dengan menggunakan refrigeran alami telah menawarkan peluang yang baik.
Skripsi ini membahas tentang pengujian sistem cascade dengan menggunakan R22 pada high-stage (HS) dan R404A pada low-stage (LS). Untuk mendapatkan nilai performa optimum serta trend dari parameter yang mempengaruhinya dengan memvariasikan nilai tekanan discharge pada sistem HS. Proses variasi dilakukan dengan mengurangi sedikit demi sedikit massa refrigeran yang mengalir didalam sistem.
Dengan memvariasikan tekanan discharge pada sistem HS dari 13-16 bar didapatkan nilai temperatur evaporasi terendah sebesar -33°C serta COP cascade maksimum sebesar 1,79. Suhu terendah tercapai pada tekanan discharge 13,8 bar sedangkan COP cascade maksimum tercapai pada tekanan discharge 16 bar.

In many industrial applications, single stage and multi stage refrigeration systems fail to widen the gap between heat source and heat sink temperatures and now cacscade system appear to be the best alternative. Modest research,in the past, has been done in cascaded sytem based on natural refrigerants thereby offering good potential for research.
In this paper, a cascaded system for simultenous heating and cooling with a R22 based high-stage (HS) cycle and R404A based low-stage (LS) cycle for simultenous refrigeration and heating application has been analyzed. To Facilate prediction of optimum performance parameter, performance trends with variation in the pressure of HS cycle have been presented. Variation processes done with releasing some refrigeran in the system trough a ventile.
The experimental results obtained by pressure variation from 13,8 to 16 bar is - 33°C for the lowest evaporating temperature and 1,79 for maksimum cascade COP. The lowest temperature reached in 13,8 bar and maksimum cascade COP in 16 bar.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37337
UI - Skripsi Open  Universitas Indonesia Library
cover
Clementino Pereira
"Tesis ini berkaitan dengan evaluasi teknis sistem pendinginan di Industri proses LNG. Proses LNG C3-MR dan refrigeran murni disimulasikan berdasarkan data suhu, tekanan dan komposisi gas alam. Selama process simulasi pengaruhnya dianalisis dengan memeriksa specific horse power, produksi LNG dan pendapatan LNG pada kedua proses tersebut. Untuk memenuhi permintaan efisiensi dan kapasitas yang besar pada proses pencairan, analisis termodinamika pada proses pencairan C3-MR dan refrigeran murni untuk LNG proses juga dievaluasi. Specific horse power pada proses pencairan untuk C3-MR dan refrigeran murni menunjukkan bahwa dengan menggunakan refrigeran murni memiliki specific horse power lebih rendah dari pada C3-MR sebesar 69%. Namun, produksi LNG dan pendapatan LNG untuk kedua proses tersebut menunjukkan bahwa proses C3-MR memiliki kapasitas produksi lebih tinggi dari pada zat pendingin murni sebesar 92% dan pendapatan LNG yang tinggi.

This thesis deals with the technical evaluation of refrigeration system in LNG process plant. The C3-MR and pure refrigerant LNG process plant was simulated based on data of natural gas temperature, pressure and composition. During the simulations the effects were analyzed by examining specific horse power, LNG production and revenue of LNG for the both processes. To meet the demand of greater efficiency and large capacity for liquefaction processes, thermodynamic analysis on the liquefaction processes for C3-MR and pure refrigerant LNG process plant also has been evaluated. The analysis of specific horse power on the liquefaction processes for C3-MR and pure refrigerant shows that using pure refrigerant has lower specific horse power than C3-MR by 69%. However, LNG production and revenue of LNG for both processes shows that C3-MR process has higher production capacity per train than that of pure refrigerant by 92% and high revenue of LNG.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
T34889
UI - Tesis Membership  Universitas Indonesia Library
cover
Donni Redford
"Penggunaan sistem refrigerasi cascade memungkinkan untuk mencapai temperatur yang sangat rendah. Pada dasarnya temperatur akan semakin rendah jika tekanan pada sistem lebih rendah. Namun pada temperatur yang lebih rendah tersebut, kinerja yang dihasilkan belum tentu yang terbaik.
Untuk mengetahui kinerja dari sistem refrigerasi dapat dilakukan dengan dua cara, yaitu dengan simulasi dan melalui eksperimen. Simulasi digunakan untuk memperkiraan kinerja sistem dengan membandingkan kinerja sistem yang menggunakan refrigeran yang berbeda. Sedangkan hasil aktual dari performa sistem diketahui melalui eksperimen yang akan dilakukan, namun dibatasi oleh jenis refrigeran yang digunakan. Pengujian ini dilakukan dengan menggunakan refrigeran R22 pada high-stage dan R404A pada low-stage.
Untuk mengetahui apakah suatu sistem sudah bekerja optimal atau tidak, perlu dilakukan variasi terhadap salah satu atau lebih variabel yang berhubungan. Salah satunya adalah dengan melakukan variasi terhadap tekanan. Variasi tersebut cukup dilakukan pada sistem low-stage dengan acuan pada tekanan discharge line. Pengujian dilakukan dengan 7 variasi dimulai dari 10,4 bar hingga 16,4 bar dengan selisih tiap 1 bar. Variasi ini dapat dilakukan dengan cara mengubah jumlah massa refrigeran, dengan tekanan yang berubah, maka parameter lain seperti temperatur, laju aliran massa, selisih entalpi kompresi, kapasitas refrigerasi mengalami perubahan. Temperatur low-stage evaporator akan menjadi lebih rendah pada tekanan yang lebih rendah, dan mencapai -35°C ketika tekanan lowstage discharge line mencapai 10,4 bar. Sementara nilai COP cenderung naikturun perlahan, dan nilai COP paling tinggi adalah 1,697, terjadi pada saat tekanan pada low-stage discharge line 13,4 bar.

The use of cascade refrigeration system make very low temperature is possible to reach. Basically, the temperature would be lower if the pressure in the system is lower. But at the lower temperature, the performance result is unsure to be the best.
To know the performance of refrigeration system can be done by two ways, that is with simulation and with experiment. Simulation used to predict the performance system by compare the system performance using different refrigerant. Whereas actual result of system performance known by doing experiment, but limited by the type of refrigerants which would be used. This test done by used refrigerant R22 in the high-stage and R404A in the low-stage.
To know if the system already optimal or not, variation is needed to one or more relative variable. One of them is to do variation toward pressure. That variation only need to be apply on low-stage system using discharge line pressure as a reference. The test done with using 7 variation start from 10,4 bar until 16,4 bar with a gap 1 bar each other. This variation can be done by change the amount of refrigerant mass, with different pressure, the other parameters like temperature, difference of compression entalphy, refrigeration capacity would be changed too. That changes make the system performance at different pressure would become different. The low-stage evaporator temperature would become lower at lower pressure, and reach -35°C when low-stage discharge line pressure reach 10,4 bar. Whereas COP value disposed to increase-decrease slowly, and the highest COP value is 1,697, it happened when the pressure of low-stage discharge line 13,4 bar.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37325
UI - Skripsi Open  Universitas Indonesia Library
cover
Napitupulu, Erwin
"The contents of fuel-oil are now running low and its prices are becoming more expensive that causes the supply of fuel-oil to the power station in PLN disturbed. Dimmed in district consecutively by the PLN is cause by this event.
Green Medical Box Portable is a storage for the vaccine and other medicine which doesn?t need to depend on electricity from PLN. Alternative source of electricity can be used from the sunlight (solar cell) and battery, so if there is any electricity failure then the temperature can still be obtained and the vaksin and other medicine always in good conditioning.
This Green Medical Box Portable have two storages. The volume of the first storage (freezer) is about 20,4 litre which temperature of storage is about - 15°C. Whereas the volume of second storage (cooler) is about 45,15 litre which temperature of storage is about 5°C.
The refrigeration system of Green Medical Box portable uses DC (Direct Curent) compressor from Danfoss with BD35K type. The refrigerant that used is R 600a."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50753
UI - Skripsi Open  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>