Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 113941 dokumen yang sesuai dengan query
cover
Rian Tri Laksono Suropati
"Meningkatnya peredaran makanan yang tidak sehat diberbagai tempat mengancam masyarakat mengkonsumsi gizi buruk. Diantaranya asupan gizi kolesterol, yang mana jika melebihi batas normal dapat memicu terjangkitnya berbagai penyakit seperti jantung koroner. Mengantisipasi terjangkitnya dari penyakit tersebut, mulai dikembangkan perangkat sensor non-enzimatik yang praktis, stabil, sederhana, dan relatif murah untuk memonitoring kadar kolesterol dalam darah dan beberapa sampel makanan seperti susu dan daging. Pada penelitian ini dikembangkan elektroda karbon pasta termodifikasi katalis nikel, NiO/CPE dengan metode hydrothermal dan Ni/CPE dengan metode elektrokimia. Diperoleh NiO bermorfologi seperti bunga sedangkan deposit nikel seperti batu karang. Hasil penelitian menunjukan bahwa Ni/CPE bekerja optimum pada pH 14 dengan sensitivitas sebesar 0,8148 μA μM-1 cm-2 dan batas deteksi sebesar 0,1645 μM, sedangkan untuk NiO/CPE pada pH 12 dengan sensitivitas sebesar 0,1449 μA μM-1 cm-2 dan batas deteksi sebesar 0,7725 μM. Hasil pengukuran kadar kolesterol dalam sampel susu kemasan menunjukan perbedaan hasil dengan informasi tabel gizi sebesar 20,42% dan 47,18% masing-masing untuk Ni/CPE dan NiO/CPE.

Increased circulation of unhealthy foods in various places threatens the community to consume malnutrition. One of which is the intake of cholesterol nutrition. When the normal limit is exceeded, it can trigger the spread of various diseases such as coronary heart disease. To anticipate the outbreak of the disease, a practical, stable, simple, and relatively inexpensive, non enzymatic sensor device for monitoring blood cholesterol levels and some food samples such as milk and meat was developed. In this research, nickel modified catalyst on carbon paste electrodes, NiO CPE by hydrothermal method and Ni CPE by electrochemical method were developed. A flower like morphology for NiO was obtained from hydrothermal method and rock like morphology was obtained from deposit nickel. Results shown that Ni CPE worked optimally at pH 14 with sensitivity of 0.8148 A M 1 cm 2 and limit of detection LoD of 0.1645 M, while NiO CPE worked optimally at pH 12 with a sensitivity of 0.1449 A M 1 cm 2 and LoD of 0.7725 M. Cholesterol level measurement from packaged milk sample showed differences of 20.42 and 47.18 from the nutrition table information for Ni CPE and NiO CPE respectively. "
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Atya Saniah
"Glutamat adalah salah satu neurotransmitter yang memainkan peran penting dalam pembentukan dan stabilisasi sinapsis, kesadaran, memori, dan proses belajar. Kadar glutamat yang tidak normal dalam tubuh dapat mengakibatkan berbagai risiko penyakit saraf. Alat untuk mendeteksi kadar glutamat yang sudah ada saat ini memiliki beberapa kekurangan yaitu memakan waktu yang lama dan mahal. Dalam penelitian ini, dibuat sensor elektrokimia glutamat berbasis elektroda glassy carbon modifikasi nikel oksida. Biosensor ini memanfaatkan reaksi elektrokimia yang terjadi pada elektroda dengan menggunakan tiga sistem elektroda dari NiO/GCE sebagai working electrode, platinum electrode sebagai counter electrode, dan Ag/AgCl sebagai reference electrode. Nikel oksida dibuat dengan menggunakan metode sol-gel. Pengujian terhadap material nikel oksida yang dibuat diuji dengan karakterisasi SEM, FTIR, dan XRD. Performa dari biosensor berbasis nikel oksida diuji dalam larutan NaOH 0,1 M. Performa dari biosensor ini akan diukur dengan metode cyclic voltammetry (CV) untuk mengukur sensitivitas biosensor yang dikembangkan. Pada hasil pengukuran dengan CV diketahui bahwa limit deteksi dan sensitivitas pada biosensor ini masing-masing sebesar 0,641 mM dan 1,498 μAmM-1cm-2. Dengan demikian, sensor elektrokimia dengan modifikasi nikel oksida ini bisa terus dikembangkan untuk biosensor glutamat tanpa enzim yang menjanjikan.

Glutamate is one of the neurotransmitters that play an essential role in forming and stabilizing synapses, awareness, memory, and learning processes. Abnormal levels of glutamate in the body can lead to various risks of neurological diseases. The existing tools for detecting glutamate levels have several drawbacks. They are time-consuming and expensive. In this research, an electrochemical glutamate sensor based on nickel oxide modified glassy carbon electrode was made. This biosensor utilizes the electrochemical reactions at the electrodes using the three-electrode system of NiO/GCE as working electrode, platinum electrode as counter electrode, and Ag/AgCl as reference electrode. Nickel oxide is made using the sol-gel method. Nickel oxide was tested with SEM, FTIR, and XRD characterization. The performance of the sensor was tested in 0.1 M NaOH solution. The performance of this biosensor will be measured by the cyclic voltammetry (CV) method to measure the sensitivity of the developed biosensor. Based on the CV measurement, it is known that the detection limit and sensitivity of this biosensor are 0.641 mM and 1.498 μAmM-1cm-2, respectively. Thus, this electrochemical glutamate sensor based on nickel oxide can continue to be developed for promising enzyme-free glutamate biosensors."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fenika Annisa
"Prototipe sistem portabel dan berbiaya rendah untuk mendeteksi glukosa berbasis potensiostat LMP91000EVM telah dibuat. Karakterisasi elektroda karbon cetak layar tanpa modifikasi (110) dan termodifikasi nikel oksida (110NI) dengan potensiostat komersial untuk melihat pengaruh nikel oksida dalam mendeteksi glukosa. Melalui metode spektroskopi impedansi elektrokimia, diperoleh nilai Rct sebesar 1276,79 Ω untuk sensor 110NI dan 429,06 Ω untuk sensor 110, sehingga sensor 110NI memiliki laju transfer elektron yang lebih lambat. Sementara itu, melalui metode voltametri siklik, diperoleh luas permukaan elektroda aktif sebesar 7,1×10-2 cm2 untuk sensor 110NI dan 6,9×10-2 cm2 untuk sensor 110, sehingga sensor 110NI lebih sensitif dalam mendeteksi glukosa. Saat konsentrasi glukosa divariasikan, nilai LOD dan LOQ sensor 110NI lebih kecil yaitu 1,807 mM dan 6,024 mM daripada sensor 110 yaitu 2,629 mM dan 8,762 mM, sehingga sensor 110NI lebih sensitif. Saat laju pemindaian divariasikan, nilai gradien sensor 110NI lebih kecil yaitu -8,14×10-4 mA s/mV daripada sensor 110 yaitu -9,62×10-4 mA s/mV, sehingga sensor 110NI tidak lebih sensitif. Selanjutnya, membandingkan prototipe sistem yang penguatan TIA divariasikan dan potensiostat komersial. Hasilnya, voltammogram siklik setiap siklus pada potensiostat komersial lebih stabil. Semakin kecil penguatan TIA pada prototipe sistem, semakin stabil, hal ini karena noise yang ikut dikuatkan semakin kecil.

A portable and low-cost system prototype for glucose detector based on LMP91000EVM potentiostat has been created. Characterization of screen-printed carbon electrodes without modification (110) and modified nickel oxide (110NI) was carried out with a commercial potentiostat to see the effect of nickel oxide in detecting glucose. Through the electrochemical impedance spectroscopy method, the Rct value of 1276,79 Ω is obtained for the 110NI sensor and 429,06 Ω for the 110 sensor, so that the 110NI sensor has a slower electron transfer rate. Meanwhile, through the cyclic voltammetry method, the surface active electrode area is 7,1×10-2 cm2 for the 110NI sensor and 6,9×10-2 cm2 for the 110 sensor, so that the 110NI sensor is more sensitive in detecting glucose. When the glucose concentration is varied, the LOD and LOQ values of the 110NI sensor are smaller, specifically 1,807 mM and 6,024 mM than the 110 sensor, specifically 2,629 mM and 8,762 mM, so the 110NI sensor is more sensitive. When the scan rate is varied, the gradient value of the 110NI sensor is smaller, specifically -8,14×10-4 mA s/mV than the 110 sensor, specifically -9,62×10-4 mA s/mV, so the 110NI sensor is not more sensitive. Next, comparing a prototype system that TIA gain is varied and a commercial potentiostat. As a result, the cyclic voltammogram per cycle on commercial potentiostat is more stable. The smaller the TIA gain on the system prototype, the more stable it is, this is because the noise that is amplified is getting smaller."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alvina Dewi Irzalinda
"Pengukuran kadar urea pada urin merupakan faktor yang sangat penting dalam menentukan kondisi kesehatan ginjal. Untuk itu dikembangkan sensor urea non enzimatik yang berbasis logam Ni yang terdeposit pada elektroda Au. Pada penelitian ini, Ni akan terdeposit pada elektroda Au dengan variasi potensial dan waktu. Kemudian deposit Ni diaktivasi dalam KOH menjadi NiOOH yang dapat mengoksidasi urea menjadi CO2, N2 dan H2 sehingga dapat dideteksi secara elektrokimia. Hasil penelitian menunjukkan bahwa Ni/Au dapat digunakan untuk mendeteksi urea dengan nilai LOD 3,35 x10-2 mM, sensitivitas 52,20 mM A-1cm-2 dan linearitas r2= 0,997 pada potensial deposisi -0,45 V vs Ag/AgCl dengan waktu deposisi selama 180 detik. Ni/Au mempunyai kedapatulangan yang baik dengan RSD 0,12 n=12 dan menunjukkan stabilitas yang baik dengan RSD 1,60 dalam kurun waktu 9 hari. Ni/Au tidak terganggu oleh adanya interferen seperti asam askorbat, glukosa, NaCl, dan KCl. Ni/Au dapat digunakan untuk mengukur kadar urea dalam sampel urin dengan hasil 9,615 mM.

Measurement of urea concentration in urine is a very important factor for determining the condition of kidney health. For this reason, a non enzymatic urea based sensor of Ni metal which is deposited on an Au electrode has developed . In this study, Ni will be deposited on the Au electrode with variation of potential and time. Then the Ni deposit is activated in KOH become NiOOH which can oxidize urea to CO2, N2 and H2, so that it can be detected electrochemically. The results showed that Ni Au can be used to detect urea with LOD value 3.35 x 10 2 mM, sensitivity 52,20 mM A 1cm 2 and linearity r2 0,997 at deposition potential 0.45 V vs Ag AgCl with time deposition for 180 seconds. Ni Au has good repeatability with RSD is 0.12 n 12 and shows good stability with RSD is 1,60 within 9 days. Ni Au is not disturbed by the presence of interferences such as ascorbic acid, glucose, NaCl, and KCl. Ni Au can be used to measure urea levels in urine samples with concentration is 9,615 mM. "
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S68801
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rahma Dewi Imansari
"Penentuan Kadar Glukosa menggunakan sensor Non-Enzimatik pada saat ini banyak dikembangkan, sebagai alternatif sensor glukosa non-Enzimatik dengan perangkat yang lebih praktis dan sederhana, digunakan Screen Printed Electrode (SPE) sebagai solusinya. Pada penelitian ini, digunakan oksida tembaga sebagai sensor non- Enzimatik yang terdeposit pada permukaan SPE dengan metode elektrodeposisi menggunakan larutan CuSO4 0.01 M dalam 0.1 M H2SO4. Variasi potensial dan waktu deposisi dilakukan untuk mendapatkan deposit CuSPE yang optimum. Uji deteksi glukosa dilakukan pada potensial +0.7 V vs Ag/AgCl. Deposit CuSPE dengan variasi potensial dan waktu -0.4 V selama 300 detik merupakan yang paling optimum karena mempunyai sensitifitas tertinggi sebesar 1063.452 μA mM-1 cm-2, batas deteksi terendah sebesar 0.485 x 10-3 M, dan linearitas paling baik sebesar R20.987. CuSPE optimum digunakan pada sistem alir, didapatkan laju alir optimum 25 mL/menit, konsentrasi NaOH optimum 1 M dilihat dari %RSD sebesar 1.19%. Pada variasi konsentrasi glukosa dihasilkan linearitas sebesar R2 0.982 dengan LOD sebesar 4.273 x 10-3 M. Sensor memiliki repeatabilitas yang baik dengan %RSD = 1.39% (n=10). Deteksi glukosa pada sampel darah dengan batch dan sistem alirmemiliki perbedaan jika dibandingkan dengan hasil deteksi pada glukosameter.

Determination of glucose concentration using Non-Enzymatic sensor has been developed, as an alternative to Non-Enzymatic glucose sensors with a device that is more practical and simple to use, Screen Printed Electrode (SPE) as a solution. In this study, use of copper oxide as a non-Enzymatic sensors are deposited on the surface of the SPE by electrodeposition method using a solution of 0.01 M CuSO4 in 0.1 M H2SO4. Variations potential and deposition time taken to obtain optimum CuSPE deposit. Glucose detection test conducted on the potential +0.7 V vs Ag/AgCl. Deposit CuSPE which was deposited in -0.4 V for 300 seconds was the optimum because it has the highest sensitivity 1063.452 μ𝐴𝑚𝑀-1𝑐𝑚-2, the lowest limit of detection0.458 x 10-3M, and most excellent linearity R2= 0.987. CuSPE optimum use of the system flow, obtained the optimum flow rate of 25 mL/ min, the concentration of 1 M NaOH optimum views of% RSD for 1.19%. In the glucose concentration variations resulting linearity of R2 0.982 with LOD of 4.273 x 10-3M. The sensor has a good repeatability with% RSD = 1.39% (n=10). Detection of glucose in the blood sample using batch and flow systemhave differences when compared with the results of the detection in glukosameter."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
S62146
UI - Skripsi Membership  Universitas Indonesia Library
cover
Haris Nurhidayat
"ABSTRAK
Kolesterol memiliki fungsi fisiologis yang luas dalam tubuh manusia, namun jika konsentrasinya melebihi batas normal maka dapat memicu penyakit seperti arteriosklerosis. Oleh karena itu metode penentuan kolesterol yang cepat dan akurat dikembangkan. Dari semua metode, sensor enzimatik banyak mendapat perhatian, namun sensor ini memilik kekurangan seperti mudah terdenaturasi. Oleh sebab itu penentuan kadar kolesterol menggunakan sensor non-enzimatik saat ini banyak dikembangkan. Perangkat sensor kolesterol non-enzimatik yang dibuat dalam penelitian ini yaitu screen printed electrode SPE yang dideposisi Cu, Ni, dan CuNi yang terhubung dengan potensiostat. Elektrodeposisi Cu, Ni, dan CuNi masing ndash; masing dilakukan pada potensial -0,512 V, -0,326 V, dan -0,804 V dengan variasi waktu deposisi 60 s, 30 s, dan 5 s. Waktu deposisi optimum yang didapatkan yaitu 60 s berdasarkan nilai linearitas, LOD, dan sensitivitas yang didapat dari deteksi kolesterol sistem batch. Cu/SPE, Ni/SPE, CuNi/SPE kemudian diterapkan dalam sistem Flow Injection Analysis FIA . Kinerja sensor optimum diperoleh pada sistem FIA dengan laju alir 0,5 mL/menit dan konsentrasi KOH 1 M. Sensor Cu/SPE, Ni/SPE, dan CuNi/SPE dalam sistem FIA masing ndash; masing memiliki LOD sebesar 1,08, 13,59, 1,24 M dan sensitivitas sebesar 3.584,97, 465,98, 3.258,54 A mM-1 cm-2. Sensor Cu/SPE, Ni/SPE, CuNi/SPE memiliki repeatabilitas yang baik dengan nilai RSD masing ndash; masing 0,68 1,58, dan 1,16. Sensor Cu/SPE, Ni/SPE, CuNi/SPE memiliki reprodusibilitas yang baik dengan nilai RSD masing ndash; masing 0,72, 1,76, dan 0,91. Sensor memiliki stabilitas yang baik yang diukur selama lima hari berturut ndash; turut dengan nilai RSD masing ndash; masing 0,66, 1,54, dan 0,93. Sensor juga selektif terhadap kolesterol dari zat penginterferensi umum yaitu glukosa, sukrosa, fruktosa, asam askorbat, dan NaCl. Cu/SPE, Ni/SPE, dan CuNi/SPE berhasil menentukan kadar kolesterol dalam sampel susu kemasan dan menunjukkan perbedaan hasil 1,88 , 3,59 , dan 3,05 serta recovery 99,79 , 98,61 dan 99,02 berturut ndash; turut.

ABSTRACT
Cholesterol has a wide physiological function in the human body, but if the concentration exceeds the normal limit it can trigger diseases such as arteriosklerosis. So rapid and accurate method of determining cholesterol is developed. Of all the methods, enzymatic sensors have received much attention, but these sensors have such deficiencies as easily denatured. Therefore, the determination of cholesterol levels using non enzymatic sensors is now widely developed. The non enzymatic cholesterol sensor device made in this study is a screen printed electrode SPE deposited with Cu, Ni, and CuNi connected to a potentiostat. The electrodeposition of Cu, Ni, and CuNi were each performed at a potential of 0.512 V, 0.326 V, and 0.804 V with variations of deposition time of 60 s, 30 s, and 5 s. The optimum deposition time obtained was 60 s based on linearity, LOD, and sensitivity obtained from batch system cholesterol detection. Cu SPE, Ni SPE, CuNi SPE are then applied in the Flow Injection Analysis FIA system. The optimum sensor performance was obtained in FIA system with 0.5 mL min flow rate and KOH concentration of 1 M. Cu SPE, Ni SPE, and CuNi SPE sensors in FIA system each have LOD of 1.08, 13.59, 1.24 M and sensitivity of 3,584.97, 465.98, 3,258.54 A mM 1 cm 2. Cu SPE, Ni SPE, CuNi SPE sensors have good repeatability with RSD values of 0.68 1.58 and 1.16, respectively. Cu SPE, Ni SPE, CuNi SPE sensors have good reproducibility with RSD values of 0.72, 1.76, and 0.91, respectively. The sensors have good stability measured for five consecutive days with RSD values of 0.66, 1.54, and 0.93, respectively. Sensors are also selective against cholesterol from common interfering substances such as glucose, sucrose, fructose, ascorbic acid, and NaCl. Cu SPE, Ni SPE, and CuNi SPE succeeded in determining cholesterol levels in packaging milk samples and showing a difference of 1.88 , 3.59 , and 3.05 and 99.79 , 98.61 And 99.02 respectively."
2017
S68000
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kevin Haposan Aripratama
"Hipoklorit adalah zat pengoksidasi yang digunakan sebagai disinfektan dan zat pemutih, serta digunakan dalam industri makanan, perawatan kesehatan dan untuk pengolahan air minum. Menurut Organisasi Kesehatan Dunia, konsentrasi klorin bebas di air minum harus antara 0,1–4 ppm karena kelebihan hipoklorit dalam tubuh akan menyebabkan penyakit yang serius seperti radang sendi, penyakit kardiovaskular, aterosklerosis, dan kanker. Karena itu diperlukan metode pendeteksi hipoklorit untuk menjaga kesehatan manusia. Pada penelitian ini akan dikembangkan metode electrocemiluminescence (ECL) untuk mendeteksi hipoklorit menggunakan elektroda screen-printed carbon (SPCE) termodifikasi nanopartikel emas (AuNP). Modifikasi SPCE dengan AuNP dilakukan dengan teknik square-wave voltammetry dengan kehadiran nicotinamide adenine dinucleotide (NAD+) sebagai capping agent. Konfirmasi dengan Field-Emmision Scanning Electron Microscopy (FE-SEM) memperlihatkan nanopartikel emas berbentuk bulat (nanosphere) yang tersebar merata dengan %wt 27,6% dan ukuran rata-rata 38 nm. Pengukuran larutan hipoklorit dengan ECL yang dilakukan dengan menggunakan elektroda kerja SPCE termodifikasi AuNP dengan elektrolit larutan bufer fosfat (PBS) 0,1 M dan koreaktan H2O2 1 mM pada pH 10 menghasilkan puncak oksidasi dan ECL luminol dengan pada potensial sekitar +0,2 V. Intensitas ECL menunjukkan linearitas pada rentang konsentrasi hipoklorit dari 0 μM sampai 50 μM menunjukkan sensitivitas sebesar 12,57 a.u. μM−1cm−2 dengan limit deteksi dan limit kuantifikasi masing-masing sebesar 1,85 μM dan 6,17 μM.

Hypochlorite is an oxidizing agent that is used as a disinfectant and bleaching agent, and is used in the food industry, healthcare and for drinking water treatment. According to the World Health Organization, the concentration of free chlorine in drinking water should be between 0.1–4 ppm because excess hypochlorite in the body will cause serious diseases such as arthritis, cardiovascular disease, atherosclerosis and cancer. Because of that, a hypochlorite detection method is needed to protect human health. In this research, the electrocemiluminescence (ECL) method will be developed to detect hypochlorite using screen-printed carbon (SPCE) electrodes modified by gold nanoparticles (AuNP). SPCE modification with AuNP was carried out by square-wave voltammetry technique in the presence of nicotinamide adenine dinucleotide (NAD+) as a capping agent. Confirmation by Field-Emission Scanning Electron Microscopy (FE-SEM) showed gold nanoparticles with a spherical shape (nanosphere) which were evenly distributed with %wt 27.6% and an average size of 38 nm. Measurement of hypochlorite solution with ECL using SPCE working electrode modified AuNP with 0.1 M phosphate buffer solution (PBS) electrolyte and 1 mM H2O2 corectant at pH 10 produced oxidation peaks and luminol ECL with a potential of about +0.2 V. ECL intensity showed linearity in the range of hypochlorite concentrations from 0 μM to 50 μM showing a sensitivity of 12.57 a.u. μM−1cm−2 with detection and quantification limits of 1.85 μM and 6.17 μM respectively."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Shella Jeniferiani Willyam
"Kolesterol merupakan parameter penting dalam analisis kesehatan rutin karena risiko yang ditimbulkan oleh kadar kolesterol tidak normal dalam darah, seperti penyakit jantung koroner dan stroke. Metode analisis kolesterol yang umum digunakan dalam bidang medis masih berbasis biosensor enzimatik yang membutuhkan instrumen rumit, prosedur mahal, dan penanganan khusus. Dalam penelitian ini, sensor kolesterol non-enzimatik yang sensitif dan selektif telah dibuat berdasarkan ikatan pembentukan kompleks antara β-siklodekstrin (BCD) dengan kolesterol dan metilen biru (MB) sebagai spesi elektroaktif. BCD difungsionalisasikan pada nanopartikel magnetik Fe3O4 (MNPs) melalui metode ko-pengendapan untuk memudahkan pengairan BCD dari bantuan menggunakan bantuan magnet eksternal. Elektroda yang digunakan dalam penelitian ini adalah karbon-elektroda (SPCE) layar-dicetak yang mudah digunakan, dan mudah digunakan untuk sampel mudah sedikit (mikroliter). Nanokomposit dikarakterisasi menggunakan FTIR, TEM, dan XRD. Sifat elektrokimia MB pada SPCE dipelajari terlebih dahulu sebelum aplikasinya dalam sensor. Aplikasi optimal yang diperoleh menggunakan nanokomposit BCD (3%) / MNPs 2% b / b, pH 7,4 dan waktu kontak 10 menit. Pengukuran kolesterol dilakukan dengan voltametri siklik (CV) pada potensial -0,6 V - 0,6 V dan scan rate 50 mV / s, serta deteksi amperometrik pada potensial konstan -0,43 V selama 90 s. Pengukuran standar kolesterol dengan metode kedua ini menunjukkan linearitas yang baik (r2> 0,99) pada rentang pengukuran 0 μM - 150 μM dengan batas deteksi 15,15 μM (arus anodik) dan 8,21 μM (arus katodik) untuk teknik CV; serta 6,28 μM untuk teknik amperometri. Sensor menunjukkan keberulangan dan verifikasi baik yang ditandai dengan nilai RSD dan persen pemulihan pada kisaran 1,91% - 3,87% dan 97,24% - 100,96%. Sensor ini juga menunjukkan selektivitas yang dengan kombinasi ganda kali lipat konsentrasi kombinasi (NaCl, CaCl2, glisin, transformasi, dan L-asam askorbat). Hasil pengukuran konsentrasi dalam sampel susu menggunakan sensor yang telah dikembangkan menunjukkan kesesuaian dengan metode HPLC (97,87% - 100,10%) dan nilai yang ditetapkan pada kemasan (94,83% - 96,99%).

Cholesterol is an important parameter in routine health check due to the risks caused by abnormal cholesterol levels in the blood, such as coronary heart disease and stroke. In this study, a sensitive and specific non-enzymatic cholesterol sensor was made based on the formation of the inclusion complex between β-cyclodextrin (BCD) with cholesterol and methylene blue (MB) as the electroactive species. The electrode used in this study was screen-printed carbon electrode (SPCE). Nanocomposites were characterized by FTIR, TEM, and XRD. The cholesterol measurement was carried out using cyclic voltammetry (CV) at potentials of -0.6 - 0.6 V and scan rate of 50 mV / s, also using amperometric detection at constant potential of -0.43 V for 90 s. The standard cholesterol solution measurement with both methods has shown good linearity, repeatability, and accuracy in the concentration range of 0 μM - 150 μM with the LOD of 15.15 μM (Ipa) and 8.21 μM (Ipc) for CV, and 6.28 μM for amperometric detection. The sensor also shows good selectivity with the existence of ten folds concentration of interference agents. The result of cholesterol concentration measurement in milk samples using the developed sensor was in agreement with the HPLC method and the stated value."
Depok: Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nadira Hanum
"Penentuan kadar kolesterol menggunakan sensor non-enzimatik pada saat ini banyak dikembangkan sebagai alternatif, sensor kolesterol non-enzimatik berupa perangkat yang praktis dan sederhana, digunakan Screen Printed Electrode SPE sebagai sensor, kemudian dimodifikasi dengan carbon nanotube CNT dan nafion Nf . Pada penelitian ini, digunakan oksida tembaga sebagai sensor non-enzimatik yang terdeposit dipermukaan SPE yang telah diteteskan CNT terfungsionalisasi-Nf, dengan metode elektrodeposisi menggunakan larutan CuSO4 0.01M dalam 0,1M H2SO4. Variasi, potensial dan waktu deposisi dilakukan untuk mendapatkan deposit Cu/CNT-Nf-SPE yang optimum, karakterisasi dengan SEM-EDX. Uji deteksi kolesterol dilakukan pada potensial 0.482V vs Ag/AgCl. Deposit Cu/CNT-Nf-SPE dengan tetesan CNT terfungsionalisasi-Nf pada potensial - 0.386V selama 300 detik merupakan yang paling optimum, karena mempunyai sensitifitas paling tertinggi sebesar 6220,6 ?A mM-1 cm-2, batas deteksi terendah sebesar 9,559 x 10-3 M dan linieritas paling baik sebesar R2 = 0.8856. Sensor deposit Cu/CNT-Nf-SPE optimum digunakan pada sistem FIA, didapatkan laju alir optimum 1,0 mL/menit, konsentrasi KOH 1 M sebagai carier dilihat dari RSD sebesar 1.0371 rata-rata respon arus 0.05046 mA. Pada variasi konsentrasi kolesterol dihasilkan linieritas sebesar R2 = 0.9916 dengan sensitifitas sebesar 3051,470 ?A mM-1 cm-2, batas deteksi terndah sebesar 9.5116 x 10-4 M sensor memiliki repeatabilitas yang baik dengan RSD sebesar 1.2944 n=10 . Uji stabilitas selama 4 hari pengamatan dengan RSD rata-rata sebesar 0.904574 . Deteksi kolesterol pada darah dengan KR 43.72. Uji selektivitas pada kolesterol terhadap sukrosa, fruktosa, dan asam askorbat.

Determination of Cholesterol sensor using non enzymatic sensor has been developed as an alternative to non enzymatic cholesterol sensor with practical and simple device, using Screen Printed Electrode SPE as sensor, which then modified with carbon nanotube CNT dan Nafion membrane Nf . In this study, copper oxide are used as non enzymatic sensor deposited on the surface of SPE dripped with functionalized CNT Nf, using electodeposition method with solution of 0.01 M CuSO4 in 0.1 M H2SO4. Droplets of functionalized CNT Nf, deposition potential and time are varied to find the optimal Cu CNT Nf SPE deposit, characterize with SEM EDX. Cholesterol detection were tested at the potential of 0.482V vs Ag AgCl. The test found that the optimal deposit was Cu CNT Nf SPE functionalized CNT Nf at potential 0.386V for 300 seconds, with highest sensitivity of 6220.6 A mM 1 cm 2, lowest detection limit of 9.569 x 10 3 M, and best linearity of R2 0.8856. The optimal sensor depositition Cu CNT Nf SPE electrode were used on flow system FIA, with result of optimal flow rate of 1.0 mL min, concentration of 1 M KOH as a carrier seen from RSD of 1.0371 with average current response 0.05046 mA. The result of variation of cholesterol concentration was linearity of R2 0.9916 with sensitivity 3051.470 A mM 1 cm 2, lowest detection limit of 9.5116 x 10 4 M, sensor have good repeatability at RSD of 1.2944 n 10 . Stability test for 4 days resulted in RSD average of 0.904574 . cholesterol detection in a blood yield KR of 43.72 , and interference test on Cholesterol to glucose, sucrose, fructose, ascorbic acid."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S69209
UI - Skripsi Membership  Universitas Indonesia Library
cover
Darine Denala
"Elektroreduksi CO2 merupakan teknik yang menjanjikan karena dapat mengkonversi CO2 secara langsung menjadi hidrokarbon. Penggunaan elektroda Cu dan boron-doped diamond (BDD) dalam proses elektroreduksi CO2 dilaporkan mampu menghasilkan konversi CO2 menjadi turunan hidrokarbon secara efisien. Pada penelitian ini, deposisi Cu2O ke permukaan BDD dan Cu dilakukan guna meningkatkan sifat katalitik BDD, sekaligus mempelajari jenis spesi Cu yang paling berperan dalam reaksi elektroreduksi CO2. Deposisi elektroda dilakukan dengan menggunakan teknik amperometri. Pada setiap elektroda dilakukan karakterisasi dengan menggunakan instrumentasi Scanning Electron Microscope (SEM), Energy Dispersive Spectroscopy (EDS), X-Ray Photoelectron Spectroscopy, dan Cyclic Voltammetry (CV). Elektroreduksi dilakukan dalam sistem dua  kompartemen berbentuk H dengan menggunakan larutan NaCl 0.1 M yang ditempatkan di katoda serta Na2SO40.1 M ditempatkan di anoda. Elektroreduksi dilakukan dengan menggunakan sistem kerja tiga elektroda yang terdiri dari elektroda kerja, elektroda pendukung berupa kawat Pt, serta elektroda pembanding Ag/AgCl pada variasi potensial -1.0 V dan -1.5 V selama 60 menit. Produk hasil reduksi dianalisa dengan menggunakan High Performance Liquid Chromatograph (HPLC) dan Gas Chromatography (GC) untuk produk liquid serta untuk untuk produk gas menggunakan Gas Chromatography (GC) dengan detektor TCD. Elektroda Cu2O-BDD menghasilkan produk yang paling bervariasi dibandingkan dengan elektroda lainnya dengan produk hasil berupa asam format, etanol, dan asam asetat. Produk dengan jumlah  paling banyak dihasilkan adalah asam asetat dengan jumlah 29,8 mg/L dengan persen (%) efisiensi faraday sebesar 68,2  % oleh elektroda Cu2O-BDD pada potensial -1.5 V.

CO2 Electroreduction is a promising technique in CO2 reduction because it can converts CO2 directly into hydrocarbon. The uses of Cu and Boron-Doped Diamond as working electrode in CO2 electroreduction is reported to be able converting CO2 into hydrocarbon derivative efficiently. In this research, Cu2O deposited into BDD and Cu surfaces to increase the BDD catalytic activity and study which Cu has the biggest role in electroreduction CO2 process. Deposition of the material into electrode surface is done using amperometry technique. Each electrode characterized using Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), and X-Ray Photoelectron Spectroscopy, and Cyclic Voltammetry (CV) instrumentation. Electroreduction process is done using  two compartment system with H-shaped using NaCl solution 0.1 M in cathode and Na2SO4 in anode. Electroreduction performed using three electrode system, which are working electrode, Pt mesh as counter electrode, and Ag/AgCl as reference electrode with -1,0 V and -1,5 V potential in 60 minutes. The resulting product is analyzed using High Performance Liquid Chromatograph (HPLC) and Gas Chromatography (GC) for liquid product and GC with TCD detector for the gas product. The reduction process using Cu2O-BDD as working electrode produced more variative products other than the other electrodes, which are formic acid, ethanol, and acetic acid. The most produced product from the process is acetic acid with in concentration 29,8 mg/L and %faradaic efficiency 68,2% using Cu2O-BDD electrode in -1,5 V potential."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>