Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 185119 dokumen yang sesuai dengan query
cover
Grace Oktavina
"Kualitas udara luar ruangan, khususnya kualitas udara mikrobiologis, belum menjadi perhatian khusus di Indonesia. Kualitas udara mikrobiologis seharusnya mendapat perhatian khusus karena pencemaran oleh mikroorganisme ke udara dapat memicu persebaran infeksi dan penyakit-penyakit lain. Penelitian ini dilakukan terhadap kualitas udara di TPA Cipayung, Depok, Jawa Barat, dan udara di permukiman sekitar TPA untuk mengetahui konsentrasi mikroorganisme dan jangkauan persebarannya di udara. Tujuan penelitian ini adalah: (1) menganalisis besarnya konsentrasi jamur Aspergillus fumigatus di area TPA Cipayung Depok; (2) menganalisis tingkat penyebaran jamur A. fumigatus pada kawasan permukiman di sekitar TPA Cipayung Depok; (3) menganalisis faktor-faktor yang mempengaruhi persebaran jamur A. fumigatus di udara di sekitar TPA Cipayung Depok. Pengambilan sampel udara dilakukan di 5 titik di TPA dan 5 titik lainnya di permukiman pada jarak 50, 100, 250, 500, dan 1.000 meter. Sampel udara diambil menggunakan alat EMS Bioaerosol Single Stage Sampler dengan debit aliran udara sebesar 28,3 L/menit. Pengambilan sampel udara untuk parameter jamur dilakukan selama satu menit pada media Malt Extract Agar dan diinkubasi pada temperatur 29-30C selama ± 48-72 jam. Parameter utama yang diteliti merupakan jamur A. fumigatus. Koloni yang tumbuh dihitung sebagai Colony-forming Units (CFU/m3). Hasil penelitian menunjukkan hasil angka kuman (konsentrasi A. fumigatus), temperature, kelembaban udara, dan kecepatan angin di TPA Cipayung pada rentang 43+13,5-1151.6+484,2 CFU/m3, 27-42oC, 40-83,8%, dan 0,4-3 m/s. Hasil pengukuran konsentrasi jamur A. fumigatus diuji secara statistik menggunakan uji non-parametrik untuk menunjukkan korelasinya dengan jumlah truk yang beraktivitas dan hasil menunjukkan korelasi (A>¼ >0,05) pada konsentrasi jamur A. fumigatus dengan jumlah truk yang beroperasi. Berdasarkan pengukuran dan perhitungan, nilai kecepatan jatuh dari spora A. fumigatus sesuai dengan Hukum Stokes, yaitu sebesar 0,000576-2,556 x10-3 m/jam dan termasuk ke dalam jenis submicroscale transport. Besarnya konsentrasi jamur yang ditemukan dapat dipengaruhi oleh suhu, kelembaban udara, dan kecepatan angin. Sementara itu, jumlah truk yang lewat serta melakukan kegiatan unloading sampah dapat mempengaruhi penambahan jumlah konsentrasi jamur karena dapat dikategorikan menjadi sumber garis (launching).

Indonesia has yet to pay a serious attention to study about outdoor air quality, especially microbial air quality. It is a subject that must be seriously studied because microorganism-sponsored air pollution could cause the spread of infection and other diseases. This study aims to assess air quality at Cipayung Landfill in Depok, West Java, and the air in the vicinity of the facility so that the concentration and the dispersion in the air of microorganism could be detected. This study aims to: (1) analyze the concentration of Aspergillus fumigatus inside the Cipayung Landfill area; (2) analyze the movement rate of A. fumigatus in air inside the Cipayung Landfill area; (3) analyze the factors influencing the movement of A. fumigatus in air inside the Cipayung Landfill area. The air sampling for the study was conducted in five points at the Cipayung Landfill area and in five points at the neighborhood around the landfill. The author obtained the air sample through using the EMS Bioaerosol Single Stage Sampler with air flow rate at 28.3 liter/minute. The air sampling, used for fungi parameter, was conducted for one minute using the Malt Extract Agar medium, which was then incubated at temperatures between 29 and 30 degree Celcius for 48 to 72 hours. The primary parameter of the study is the A. fumigatus. The grown colony is counted as colony-forming units (CFU/m3). The results show that the concetration of A. fumigatus, temperature, humidity level and wind speed at Cipayung Landfill are, 43+13,5-1151.6+484,2 CFU/m3, 27-42oC, 40-83,8%, dan 0,4-3 m/s. The measurement results of A. fumigatus concentration is assessed by a non-parametric assessment to show its correlation with the number of trucks conducting activities at the facility. The results show the correlation (A>¼>0,05) between the two. Based on measurement and calculation, the downward velocity of the spores of A. fumigatus is inline with the Stokes Law at 0,000576-2,556 x10-3 m/hour and is part of submicroscale transport. The amount of fungi concentration found at the facility is influenced by temperature, humidity and wind speed. Meanwhile, the number of trucks passing at the facility and unloading waste there could influence the rise of concentration of fungi because it can be categorized as a linear source (launching)."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Cindy Ruth Maharini
"Rumah Pemotongan Hewan (RPH) di Indonesia seringkali belum memenuhi standar operasional, higienis dan sanitasi yang berlaku. Dengan demikian, hal tersebut dapat menimbulkan risiko pencemaran udara mikrobiologis oleh bakteri dan jamur. Penelitian ini bertujuan untuk mengetahui kualitas udara mikrobiologis pada RPH, serta pengaruh parameter fisik lingkungan dan jumlah hewan ternak terhadap konsentrasi mikroba di udara dengan parameter bakteri, jamur, dan bakteri E. coli. Pengambilan sampel udara mikrobiologis dilakukan sebanyak 5 kali. Sampel diambil diambil menggunakan alat EMS Bioaerosol Sampler, dengan menggunakan media TSA untuk bakteri, media MEA untuk jamur, dan media EA untuk E. coli, serta dilakukan secara triplo. Kemudian, hubungan antara jumlah hewan ternak dalam kandang hewan dan konsentrasi mikroba di udara akan dianalisis menggunakan uji statistik parametris dengan uji korelasi. Hasil pengukuran sampel menunjukkan konsentrasi bakteri dan jamur yang sebagian besar belum memenuhi baku mutu indoor Keputusan Menteri Kesehatan Republik Indonesia No. 1405/Menkes/SK/XI/2002, sementara baku mutu outdoor Polish Standard PN-Z-04111-02:1989 telah terpenuhi pada dua lokasi outdoor. Konsentrasi mikroba indoor rata-rata 2.565 CFU/m3 dan seluruh lokasi tidak memenuhi baku mutu, dan konsentrasi mikroba outdoor rata-rata 2.983 CFU/m3 . Hasil korelasi statistik menunjukkan korelasi yang kuat antara peningkatan jumlah hewan ternak dengan konsentrasi mikroba di udara dengan nilai korelasi rata-rata diatas 0,5.

Abattoirs (RPH) in Indonesia often do not meet operational standards, hygienic and sanitary regulations. Thus, it can pose a risk of microbiological air contamination by bacteria and fungi. This study aims to determine the microbiological air quality at the abattoir, also the influences of the physical parameters of the environment and the number of cattle on the concentration of airborne microbes with the parameters of bacteria, fungi, and E. coli. Microbiological air sampling was performed 5 times. Samples were taken using EMS Bioaerosol Sampler, using medium TSA for bacteria, MEA medium for fungi, and EA medium for E. coli, the samples were taken in triplo. Then, the correlations between the number of cattles and microbial air concentration were analyzed with statistic parametric test using the correlation test. The samples measurement showed that most of the concentrations of bacteria and fungi haven?t meet the indoor microbial air quality standard (Kemenkes No. 1405/Menkes/SK/XI/2002) and outdoor microbial air quality standard (Polish Standard PN-Z-04111-02: 1989) that has been fulfilled by two outdoor locations, with the average concentration of indoor microbial air concentration at 2.565 CFU/m3, and the average of outdoor microbial air concentration at 2.983 CFU/m3. Statistical correlation analysis showed a strong correlation between the increase of the number of cattles along with microbial air concentration by the average correlation values of above 0.5."
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64366
UI - Skripsi Membership  Universitas Indonesia Library
cover
Narsya Prisila
"Sebagian besar timbulan sampah yang dihasilkan oleh masyarakat di Kota Depok adalah sampah organik. Dengan jumlah tempat pemrosesan akhir sampah yang sedikit, maka fasilitas pengomposan menjadi solusi. Namun, fasilitas pengomposan dapat menjadi sumber pencemar mikroorganise yang dapat mempengaruhi pekerja maupun peduduk yang tinggal dekat lokasi pengomposan Salah satu mikroorganisme yang dimaksud adalah jamur Aspergillus fumigatus, dimana jamur tersebut merupakan mikroba indikator yang dapat bersifat patogen yang dapat menyebabkan penyakit Aspergillosis. Fasilitas pengomposan sebagai studi kasus penelitian kali ini adalah UPS TPA Hanggar 4 Cipayung, Depok, Jawa Barat. Penelitian dilakukan terhadap konsentrasi jamur A. fumigatus di udara dan gundukan kompos, kualitas kompos hasil prosuksi, dan serta faktor-faktor yang mempengaruhi jalur persebaran jamur A. fumigatus. Konsentrasi jamur A. fumigatus di udara diambil dengan menggunakan EMS Bioaerosol Sampler Single Stage Sampler dengan menggunakan media Malt Extract Agar pada area loading sampah, area pencacahan, area gundukan kompos, dan area pengayakan. Pengambilan sampel pada gundukan kompos dilakukan pada kedalaman 20 cm, 90 cm, dan 160 cm dari permukaan kompos. Pengambilan sampel di udara dan gundukan kompos tersebut dilakukan setiap 7 hari sekali selama 70 hari. Parameter kualitas kompos utama yang diteliti adalah suhu kompos, pH, kadar air, rasio C/N, serta kemampuan ikat air WHC, dengan parameter tambahan pada kompos umur 7 hari dan kompos matang yaitu lignin, total Phosphor, dan kadar volatil. Konsentrasi jamur A. fumigatus di udara pada keempat area pengambilan sampel tertinggi adalah 15,6 x 10 CFU/m pada area loading sampah pada minggu ke-28 dan gundukan kompos pada umur kompos 14 hari yaitu sebesar 116 CFU/gram. Berdasarka kualitas kompos yang didapatkan juga memenuhi rentang baku mutu SNI 19-7030-2004. Konsentrasi jamur A. fumigatus pada fasilitas pengomposan utamanya dipengaruhi oleh kegiatan seperti pembalikan, pencacahan, loading sampah, maupun pengayakan kompos, namun turut dipengaruhi oleh faktor lain seperti suhu udara, kelembapan udara, serta kecepatan dan arah angin. A. fumigatus dapat menyebabkan penyakit seperti, Aspergillosis, pada pernapasan dan kulit manusia.

Most of the waste produced by people in Depok City is organic waste. With a big amount of final waste bin, the composting facility becomes the solution. However, the composting facility can be a source of micro pollutants that can affect the workers and people near the location of the composting site. One of the microorganisms is called Aspergillus fumigatus fungus, an indicator that can affect Aspergillosis disease. Composting facility as case study of this case is UPS TPA Hanggar 4 Cipayung, Depok, West Java. The research was focus on fungi A. fumigatus content in air and mound of compost, quality of compost result, and also factors that is influencing fungus A. fumigatus distribution path. The concentration of fungus A. fumigatus was solved by using EMS Bioaerosol Sampler Single Stage Sampler with Malt Extract Agar media in feedstock loading area, shredding area, compost mound area, and sieving area. Sampling at the mound is carried out at a depth of 20 cm, 90 cm, and 160 cm from the compost surface. Sampling in air and mound of compost is done every 7 days for 70 days. The main compost quality parameters studied were compost temperature, pH, moisture content, C N ratio, and water holding capability WHC, with additional parameters on 7 days old sompost and mature compost ie lignin, total phosphor, and volatile solid. The concentration of air fungi A. fumigatus in the highest sampling peak area was 15.6 10 CFU m at waste loading area at week 28 and compost mound at 14 days compost time was 116 CFU gram. Based on the quality of the compost obtained also meets the quality standard of SNI 19 7030 2004. Concentration of fungus A. fumigatus in composting facility not only influenced by activities such as turning, shredding, feedstock loading, and sieving, but also influenced by factors such as air temperature, humidity, and wind speed and direction. A. fumigatus can cause diseases such as, Aspergillosis, on the breathing and human skin."
Depok: Fakultas Teknik Universitas Indonesia, 2018
Spdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Amirah Tri Ayudia
"Instalasi Pengolahan Lumpur Tinja (IPLT) merupakan pengolahan air limbah yang dirancang hanya menerima dan mengolah lumpur tinja yang berasal dari sistem setempat yang diangkut melalui sarana pengangkutan lumpur tinja. Lumpur tinja yang dihasil tersebut tentu harus diolah terlebih dahulu agar sesuai dengan baku mutu yaitu, Peraturan Menteri Lingkungan Hidup Nomor 68 Tahun 2016 Tentang Baku Mutu Air Limbah Domestik. Namun demikian, dalam proses pengolahan air limbah ini, tidak dapat dihindari kemungkinan terlepasnya pencemar udara mikrobiologis (bioaerosol) ke udara sekitar. Tujuan penelitian ini untuk mengetahui sumber pencemar, mengetahui total bakteri dan jamur di udara serta perbedaan konsentrasi bakteri dan jamur pada musim kemarau dan musim hujan, dan meninjau faktor lingkungan (suhu, kelembaban, dan Kecepatan angin) yang mempengaruhi konsentrasi. Penelitian ini dilakukan pada musim kemarau dan hujan dengan masing-masing lima hari pengambilan dan dilakukan di empat titik pada IPLT Kalimulya Depok (unit bak pengisian, digester anaerob, pemekat lumpur, dan biofilter aerob-anaerob). Dari hasil penelitian, rata-rata konsentrasi bakteri pada musim kemarau yaitu unit bak pengisian sebesar 243±265 CFU/m3, pemekat lumpur sebesar 155±326 CFU/m3, digester anaerob sebesar 154±157 CFU/m3, dan biofilter aerob anaerob sebesar 76±122 CFU/m3. Sedangkan pada musim hujan konsentrasi bakteri yaitu unit bak pengisian sebesar 33±24 CFU/m3, pemekat lumpur sebesar 25±62 CFU/m3, biofilter aerob-anaerob sebesar 21±20 CFU/m3, dan digester anaerob sebesar 16±13 CFU/m3. Kemudian pada musim kemarau, konsentrasi jamur pada pemekat lumpur sebesar 516±554 CFU/m3, unit bak pengisian sebesar 364±202 CFU/m3, digester anaerob sebesar 340±181 CFU/m3, dan biofilter aerob-anaerob sebesar 231±201 CFU/m3. Sedangkan pada musim hujan konsentrasi jamur pada unit bak pengisian sebesar 58±39 CFU/m3, pemekat lumpur sebesar 55±33 CFU/m3, digester anaerob sebesar, 36±32 CFU/m3, dan biofilter aerob-anaerob sebesar 32±23 CFU/m3. Sehingga, diketahui konsentrasi bakteri tertinggi ditemukan pada unit bak pengisian pada musim kemarau dan terendah pada digester anaerob pada musim hujan. Konsentrasi jamur tertinggi ditemukan di pemekat lumpur pada musim kemarau dan terendah pada biofilter aerob-anaerob pada musim hujan. Konsentrasi bakteri dan jamur berada dibawah standar baku mutu. Sedangkan korelasi antara faktor lingkungan terhadap konsentrasi bakteri dan jamur ditemukan di beberapa tempat dan terdapat juga perbedaan konsentrasi bakteri dan jamur pada musim kemarau dan musim hujan.

Sewage Treatment Plants (STPs) are wastewater processing systems that are designed to process only stool mud received from local systems of stool mud transport. The stool mud received must be processed so that it abides to the standard of quality according to the Regulation of the Minister of the Environment Number 68 Year 2016 concerning Domestic Wastewater Quality Standards. However, in the treatment process, there is a probability for a microbiological air pollutant (bioaerosol) to be produced that cannot be avoided. This research aims to analyze the source of pollution, the total amount of bacteria and fungi in the air, the difference of bacteria and fungi concentration between the dry and rainy season, and observe the environmental factors (temperature, humidity, wind speed) that affects bacteria and fungi concentration. This research was done during the dry and rainy season, each for a 5 day period in four observation points at the Kalimulya Depok STP (filling unit, anaerobic digester, mud concentrator and aerobic-anaerobic biofilter). The results of this research shows that the average bacteria concentration during the dry season is 243±265 CFU/m3 at the filling unit, 155±326 CFU/m3 at the mud concentrator, 154±157 CFU/m3 at the anaerobic digester, and 76±122 CFU/m3 at the aerobic-anaerobic biofilter. During the rainy season, the average bacteria concentration is 33±24 CFU/m3 at the filling unit, 25±62 CFU/m3 at the mud concentrator, 21±20 CFU/m3 at the aerobic-anaerobic biofilter, and 16±13 CFU/m3 at the anaerobic digester. The average fungi concentration during the dry season is 516±554 CFU/m3 at the mud concentrator, 364±202 CFU/m3 at the filling unit, 340±181 CFU/m3 at the anaerobic digester, and 231±201 CFU/m3 at the aerobic-anaerobic biofilter. As for the rainy season, the average fungi concentration is 58±39 CFU/m3 at the filling unit, 55±33 CFU/m3 at the mud concentrator, 36±32 CFU/m3 at the anaerobic digester, and 32±23 CFU/m3 at the aerobic-anaerobic biofilter. It can be seen that for the bacteria concentration, its highest value occurs at the filling unit during the dry season while its lowest value occurs at the anaerobic digester during the rainy season. For the fungi concentration, its highest value occurs at the mid concentrator during the dry season while its lowest value occurs at aerobic-anaerobic biofilter during the rainy season. The bacteria and fungi concentration values lie below the standard of quality. There are several correlations between environmental factors and the bacteria and fungi concentration values in some of the observed locations. There is also a difference between the bacteria and fungi concentration during the dry season and the rainy season.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rizky Amalia Kusuma
"ABSTRAK
Tempat Pemrosesan Akhir (TPA) Cipayung, Depok, yang berada di daerah pemukiman warga tentu saja memberikan dampak bagi kehidupan warga sekitar, salah satunya ialah pencemaran udara baik karena bau yang ditimbulkan maupun mikroba yang berasal dari tumpukan sampah yang ada di TPA Cipayung, Depok tersebut. Oleh karena itu penelitian ini dilakukan untuk melihat kualitas udara mikrobiologis yang dilakukan di 3 lokasi sampling di daerah sekitar TPA Cipayung, Depok.
Konsentrasi jamur maksimum yang didapat dari 3 lokasi sampling ialah sebanyak 4099 CFU/m3 dan minimum sebanyak 848 CFU/m3. Sedangkan untuk bakteri, konsentrasi maksimumnya ialah sebanyak 14276 CFU/m3 dan minimumnya ialah sebanyak 890 CFU/m3. Jika mengacu kepada hasil penelitian yang dilakukan oleh Shelton et al., 2002 untuk jamur dan Folmsbee & Strevett, 1999 untuk bakteri maka sebagian besar konsentrasi jamur dan bakteri di 3 lokasi sampling di daerah sekitar TPA Cipayung, Depok melebihi hasil penelitian tersebut, sehingga bisa menyebabkan dampak lebih lanjut bagi masyarakat sekitar.
Upaya untuk mencegah agar udara yang berasal dari tumpukan sampah di TPA Cipayung, Depok tidak masuk ke pemukiman warga ialah dengan memasang ventilasi gas serta green barrier di wilayah TPA Cipayung, Depok.

ABSTRACT
Place of End Processing (TPA) Cipayung, Depok, which located in residential areas certainly impact the lives of people around, one of which is either due to air pollution and microbial odor that generated from the waste pile at the landfill Cipayung, Depok. Therefore, the study was conducted to look at microbiological air quality at three locations in the area around the Cipayung, Depok landfill.
The maximum concentration of fungal that obtained from 3 sampling locations area is 4099 CFU/m3 and the minimum concentration is 848 CFU/m3 For bacterial, the maximum concentration is 14276 CFU/m3 and the minimum concentration is 890 CFU/m3. Referring to the results of research conducted by Shelton et al., 2002 for fungal and Folmsbee & Strevett, 1999 for bacterial, that the most concentration of fungal and bacterial in the three sampling locations area around the Cipayung, Depok landfill are exceed the results, which can cause further impact to the surrounding community.
Efforts to prevent the spread of air pollution from waste in the Cipayung, Depok landfill are by using gas vents and green barrier around the Cipayung, Depok landfill area."
2012
S42107
UI - Skripsi Open  Universitas Indonesia Library
cover
Diinii Haniifah
"Kualitas udara dalam ruangan di rumah sakit harus menjadi perhatian khusus karena pasien salah satu sumber pencemar mikroorganisme patogen ke udara yang dapat memicu persebaran infeksi nosokomial, maka dilakukan penelitian terhadap kualitas udara di salah satu rumah sakit di Depok, yaitu Rumah Sakit Tugu Ibu, untuk mengetahui konsentrasi mikroorganisme di udara. Sampel udara diambil menggunakan EMS Bioaerosol Sampler Single Stage Sampler dengan debit aliran udara sebesar 28,3 L/menit. Bakteri di udara diambil selama dua menit pada media Tryptic Soy Agar dan diinkubasi pada temperatur 35-37oC selama 24 jam, sementara itu jamur pada media Malt Extract Agar selama dua menit dan diinkubasi pada temperatur 25-29oC selama 48-72 jam. Koloni yang tumbuh dihitung sebagai colony-forming Units CFU/m3 . Hasil penelitian menunjukkan hasil angka kuman, temperature dan kelembaban udara dalam ruangan pada rentang 1.385-2.930 CFU/m3, 25-28oC dan 72-91 yang mana melebihi batas baku mutu KepMenKes No. 1204/MENKES/SK/X/2004. Hasil pengukuran konsentrasi diuji secara statistik menggunakan uji non-parametrik untuk menunjukkan korelasi dengan jumlah orang dan hasil menunjukkan korelasi sig< 0,05 pada konsentrasi bakteri dengan jumlah orang dan tidak menunjukkan korelasi sig > 0,05 pada konsentrasi jamur dengan jumlah orang. Berdasarkan pengukuran dan perhitungan, sebagian besar Bilangan Reynold lebih besar dari 2.000 yang mengindikasikan bahwa jenis aliran udara didominasi oleh aliran turbulen. Jumlah pertukaran udara sebagian besar kurang dari 4 kali/jam sehingga tidak memenuhi standar yang ditetapkan oleh ASHRAE 1999 . Besarnya konsentrasi bakteri dan jamur dipengaruhi oleh temperature, kelembaban udara, kecepatan udara, jenis aliran udara, dan pertukaran udara per jam. Sementara itu, jumlah orang sangat berpengaruh terhadap konsentrasi bakteri namun tidak berpengaruh terhadap konsentrasi jamur.

Indoor air quality in hospital has to be considered because patients could be a source of pollutant and lead a nosocomial infection. Therefore, bioaerosol was measured in selected hospitals at city of Depok, which is Tugu Ibu Hospital. Air sampling was conducted by using EMS Bioaerosol Single Stage Sampler and worked at a flowrate of 28.3 l min. Airborne bacteria were collected for two min on Tryptic Soy Agar and then incubated at 35 37oC for 24 h, while fungi on Malt Extract Agar for two min and then incubated at 25 29oC for 48 72 h. The colonies were counted as colony forming units CFU m3 . The result showed that indoor air bacteria and fungi concentrations, air temperature and humidity with the range approximately between 1,385 2,930 CFU m3, 25 28oC and 72 91 , respectively. All the numbers have exceeded the quality of standards by Ministry of Health Decree No. 1204 MENKES SK X 2004. Spearman rank correlation showed strong correlation sig 0.05 between indoor air bacteria concentrations and number of visitors and no correlation sig 0.05 between indoor air fungi concentrations and number of visitors. Based on measurements and calculations, Reynold numbers were mostly over 2,000, which indicated the indoor airflow dominated by turbulent flow. Air change rates were mostly less than 4 times hour and did not meet quality standards by ASHRAE 1999 . Indoor air bacteria and fungi concentrations were influenced by temperature, air humidity and velocity, type of airflow and air change rates. Meanwhile, number of visitors affected the concentration of bacteria but did not on fungi."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67487
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rohadatul Aisy Afla
"Kualitas udara pada ruang rawat inap merupakan poin penting yang perlu diperhatikan untuk menghindari risiko dan gangguan kesehatan yang dapat tersebar melalui udara. Indikator bioaerosol dalam ruangan yang dipakai adalah bakteri dan jamur. Alat yang digunakan untuk pengambilan sampel bakteri dan jamur pada Gedung A RSCM adalah EMS dan media kultur TSA serta MEA. Sampel bakteri diinkubasi pada suhu ±37oC selama ±24 jam, sedangkan jamur diinkubasi pada suhu ±27oC selama ±48 jam. Tujuan dari penelitian ini adalah untuk mengetahui perbedaan konsentrasi bakteri dan jamur pada ruang perawatan kelas 1, VIP, dan VVIP dan menganalisis faktor lingkungan yang dapat mempengaruhi keberadaan bioaerosol dalam ruangan. Dari penelitian yang telah dilakukan, hasil uji perbedaan konsentrasi bakteri pada ruang rawat inap yang diperoleh adalah 0,02 dengan tingkat signifikansi (α) 0,05 dengan menggunakan uji Kruskal-Wallis, sedangkan untuk jamur sebesar 0,002. Sehingga ada perbedaan konsentrasi bakteri dan jamur pada ruang perawatan kelas 1, VIP, dan VVIP. Suhu dan kelembaban diketahui sebagian besar tidak memiliki hubungan dengan kualitas bioaerosol dalam ruang rawat inap. Hasil uji korelasi Spearman untuk suhu dan bakteri adalah 0,085; 0,567; 0,000, sedangkan untuk suhu dan jamur adalah 0,058; 0,168; 0,05. Uji korelasi Spearman untuk kelembaban dan bakteri 0,095; 0,688; 0,320, sedangkan untuk kelembaban dan jamur adalah 0,399; 0,008; 0,920. Dari data tersebut dapat dijelaskan bahwa pada beberapa ruangan rawat inap tidak ada hubungan antara faktor lingkungan dengan konsentrasi bakteri dan jamur.

Air quality in the patient room is an notable point that need to be considered to avoid risk and some health problems that can be spread through the air. Bioaerosol indicator for indoor air pollutants are bacteria and fungi. Air samples were taken by EMS with TSA and MEA culture media. This research was taken in Gedung A RSCM. Bacteria sampel would be incubated at 37oC for 24 hours, while fungi would be incubated at ±27oC for ±48 hours. This research wanted to know the difference between bacteria and fungi concentration at kelas 1, VIP, and VVIP inpatient rooms. The results showed that there is a difference of bacteria and jamur concentration between the class of inpatient rooms, because the level significant of Kruskal-Wallis (α = 0,05) for bacteria concentration is 0,02 and 0,002 for fungi concentration. Temperature and humidity mainly did not have any specific relation with bioaerosol quality in inpatient rooms. The results for Spearman’s corelation for humidity and bacteria are 0,085; 0,567; 0,000. Meanwhile, for temperature and bacteria area 0,095; 0,688; 0,320 and for humidity and fungi are 0,399; 0,008; 0,920. From those data known that some of the inpatient rooms were not had relation between environment factors with bacteria and fungi concentration."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aliyya Maitsaa Iffat
"Kualitas udara mikrobiologis di dalam lift gedung perlu diperhatikan karena sebagian besar orang lebih memilih untuk menggunakan lift daripada tangga. Banyaknya orang berlalu-lalang memungkinkan mikroorganisme untuk masuk dan mengalami pertumbuhan pada lingkungan yang ideal di dalam lift. Studi literatur mengenai keberadaan bioaerosol di dalam lift masih tergolong sedikit. Oleh sebab itu, penelitian kualitas udara mikrobiologis penting dilakukan di salah satu ruangan pada lingkungan kampus, yaitu lift gedung kuliah saat masa libur dan aktif perkuliahan. Penelitian ini dilakukan di lift pada Gedung S, K dan EC di Fakultas Teknik Universitas Indonesia dengan tujuan untuk mengetahui serta membandingkan hasil konsentrasi bakteri pada masa libur dan aktif perkuliahan, menganalisis pengaruh faktor lingkungan dan potensi sumber pencemar mikrobiologis potensial di sekitar lift gedung perkuliahan. Metode pengambilan sampel pasif digunakan untuk mengambil sampel udara selama 15 menit agar bakteri terdeposisi secara alami ke media Tryptone Soya Agar. Pengambilan sampel permukaan dengan dry swab dilakukan untuk mengetahui apakah tombol panel lift termasuk ke dalam salah satu sumber pencemar mikrobiologis potensial. Dari hasil penelitian dapat diketahui konsentrasi bakteri pada ketiga lift gedung tidak memenuhi baku mutu, yaitu 500 CFU/m3 dan 700 CFU/m3. Pada masa libur, konsentrasi tertinggi sebesar 1.330 CFU/m3 terdapat di lift Gedung EC dan terendah sebesar 608 CFU/m3 terdapat di lift Gedung S. Sedangkan pada masa aktif,  konsentrasi tertinggi sebesar 2.084 CFU/m3 terdapat di lift Gedung S dan terendah sebesar 1.081 CFU/m3 terdapat di lift Gedung K. Hasil uji komparatif menunjukkan bahwa hanya lift Gedung S yang memiliki perbedaan konsentrasi bakteri pada kedua masa perkuliahan. Uji korelasi antara konsentrasi bakteri dengan faktor lingkungan bervariasi tergantung pada kondisi cuaca selama pengambilan sampel. Hanya kecepatan angin yang tidak mempengaruhi karena menyebabkan tidak adanya dispersi mikroorganisme. Sumber indoor bioaerosol seperti keberadaan manusia sebagai pengguna lift sangat berpengaruh sangat kuat terhadap konsentrasi bakteri di dalam lift gedung. Perlu dilakukan pemeliharaan kebersihan secara rutin terhadap pendingin ruangan beserta filter, tombol panel lift, serta lingkungan di sekitar lift gedung agar dapat menurunkan konsentrasi bakteri.

Microbiological air quality in the building elevator needs to be considered because most people prefer to use elevators rather than stairs. The number of people passing by allows microorganisms to enter and grow in the ideal environment of elevator. Literature studies regarding the presence of bioaerosol in elevators are still relatively small. Therefore, microbiological air quality research is important in one of the rooms on the campus environment, the college building elevator during holidays and active periods of lectures. This research was carried out in the elevators of the S, K and EC Buildings at the Faculty of Engineering, University of Indonesia with the air of knowing and comparing the results of bacterial concentration during holidays and active periods of lectures, analyzing the influence of environmental factors and potential sources of potential microbiological pollutants around elevators. The passive sampling method is used to take air samples for 15 minutes so that bacteria are naturally deposited into the Tryptone Soya Agar medium. The surface samples taken by dry swab is done to find out whether the elevator panel button is included in one of the potential microbiological pollutant sources. From the results of research, it can be seen that bacterial concentrations in the three building elevators did not meet the quality standards, 500 CFU/m3 and 700 CFU/m3. During the holidays, the highest concentration of 1.330 CFU/m3 is found in the EC Building elevator and the lowest is 608 CFU/m3 in the S Building. While the active period, the highest concentrations of 2.084 CFU/m3 is found in the S building elevator and the lowest is 1.081 CFU/m3 in the K Building elevator. The comparative test results show that only the S Building elevator has a difference in bacterial concentration in the two lecture periods. Correlation test between bacterial concentration and environmental factors varies depending on weather conditions during sampling Only the wind speed does not affect because it causes no dispersion of microorganisms. Indoor bioaerosol sources such as the presence of humans as elevator users have a very strong influence on the concentration of bacteria in the building elevator. Routine hygiene maintenance needs to be done on air conditioners along with filters, elevator panel buttons, and the environment around the building elevators to reduce the concentration of bacteria."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Isnainy Valencia Sari
"Pencemaran bioaerosol yang ada di dalam ruangan memiliki potensi 1.000 kali lebih berbahaya daripada di luar ruangan. Oleh karena itu, kualitas udara mikrobiologis pada ruang kuliah Gedung S di FTUI Depok perlu diteliti lebih lanjut. Sampel udara diambil menggunakan EMS bioaerosol single stage sampler selama dua menit dengan debit pemompaan 28,3 L/menit. Media pertumbuhan yang digunakan untuk bakteri dan jamur adalah TSA dan MEA. Konsentrasi bakteri tertinggi pada ruang kelas S101 2.407 362 CFU/m3 , terendah terdapat pada Lobby 1 384 142 CFU/m3. Konsentrasi jamur tertinggi ditemukan pada ruang kelas S203 810 215 CFU/m3, terendah pada S503 195 51 CFU/m3. Sebagian besar konsentrasi bakteri di udara melebihi baku mutu, sedangkan konsentrasi jamur masih memenuhi baku mutu. Suhu seluruh ruangan 21-27oC sudah memenuhi baku mutu dan kelembapan 38-71 serta Intensitas cahaya 4,21-335 lux pada sebagian ruangan tidak memenuhi baku mutu. Uji-Independent T-test menunjukan terdapat perbedaan signifikan pada konsentrasi jamur dan bakteri lantai bawah dan lantai atas sig< 0,05. Korelasi Pearson Product Moment menunjukkan terdapat korelasi yang kuat antara jumlah orang dengan konsentrasi bakteri r=0,73 dan berkorelasi lemah dengan konsentrasi jamur r=0,47. Jenis aliran udara didominasi oleh aliran laminer dan kecepatan partikel bakteri dan jamur pada kisaran 0,002-0,16 cm/detik.

Indoor bioaerosol contamination has potency 1,000 times more dangerous than outdoor. Therefore, microbiological air quality in the classrooms of Building S Engineering Faculty UI City of Depok need to be further investigated. The air samples were taken by using EMS bioaerosol single stage sampler in two minutes with airflow rate 28.3 L minute. The growth media used were TSA and MEA for bacteria and fungi. Highest bacterial concentration found in classroom S101 2,407 362CFU m3 , lowest in Lobby 1 384 142 CFU m3. The highest fungi concentration found in classroom S203 810 215 CFU m3, lowest in classroom S503 195 51 CFU m3. Most of the bacteria concentrations exceeded whereas the fungi concentration still met the quality standard. For the environmental factors, the entire classroom temperatures 21 27oC have met the quality standard but not the humidity 38 71 and light intensities 4.21 335 lux. The Independent T test showed that there were significance differences between bacteria and fungi on lower and upper floor sig."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jasmina Pertiwi
"DKI Jakarta merupakan salah satu daerah urban dengan kepadatan penduduk yang tinggi dan memiliki mobilitas kegiatan penduduk yang tinggi pula. Kegiatan penduduk seperti perindustrian, perkantoran, perumahan, dan transportasi akan menghasilkan pencemaran udara dimana pencemar tersebut akan dibuang ke udara bebas. Semakin besar peningkatan pencemaran udara akan semakin menurunkan kualitas udara ambien. Penelitian ini dilakukan penulis dengan observasi terhadap 4 lokasi sampling di wilayah DKI Jakarta dan Bukit Kototabang, Sumatera Barat sebagai Stasiun Global Atmosphere Watch (GAW) untuk Indonesia Bagian Barat. Analisis dilakukan terhadap sampel bulan April 2014-September 2014 untuk musim kemarau dan sampel bulan Oktober 2014-Maret 2015 untuk musim hujan. Konsentrasi SO2 saat musim kemarau lebih tinggi daripada saat musim hujan, dapat dilihat dari adanya penurunan konsentrasi saat musim hujan sebesar 5,126 μg/Nm3 untuk lokasi BMKG Jakarta; 5,023 μg/Nm3 untuk lokasi Monumen Nasional; 1,634 μg/Nm3 untuk lokasi Ancol; dan 6,502 μg/Nm3 untuk lokasi Glodok. Terjadi peningkatan konsentrasi SO2 di lokasi sampling GAW Bukit Kototabang sebesar 17,475 μg/Nm3 yang diakibatkan oleh adanya kebakaran hutan di Provinsi Riau. Konsentrasi NO2 saat musim kemarau lebih tinggi daripada saat musim hujan, dapat dilihat dari adanya penurunan konsentrasi saat musim hujan sebesar 0,583 μg/Nm3 untuk lokasi GAW Bukit Kototabang, 8,902 μg/Nm3 untuk lokasi BMKG Jakarta; 12,306 μg/Nm3 untuk lokasi Ancol; dan 2,0139μg/Nm3untuk lokasi Glodok. Konsentrasi SO2, NO2, dan logam Pb di udara saat musim hujan menurun karena adanya pengendapan atau pengumpulan polutan tersebut di awan dan terkondensasi menjadi bentuk cair / hujan (bentuk H2SO4 dan HNO3). Kualitas udara ambien terbaik di DKI Jakarta terdapat pada daerah Badan Meteorologi Klimatologi dan Geofisika (BMKG) dan terburuk pada Glodok, hal ini terkait kepada jumlah kendaraan bermotor yang melewati titik daerah sampling tersebut.

DKI Jakarta is one of the urban areas with highly crowded population and has a high mobility of daily activities. People activities in industrial, offices, housing, and using transportations will produce air pollution whose pollutants will be discharged into the air. The more the polution increases, the less the quality of ambient air will be. The research was conducted with the observation of 4 sampling locations in Jakarta and Bukit Kototabang, West Sumatera as the Global Atmosphere Watch (GAW) for Western Indonesia. Analyses were performed to samples of April 2014-September 2014 for the dry season, and samples of October 2014-Maret 2015 for the rainy season. SO2 gas concentrations in ambient air while the dry season is higher than the rainy season, can be seen from the presence of a decrease in the concentration of 5,126 μg/Nm3 for BMKG Jakarta; 5,023 μg/Nm3 for national monuments (Monas); 1,634 μg/Nm3 for Ancol; and 6,502 μg/Nm3 for Glodok. An increase in the concentration of SO2 in the sampling location GAW Bukit Kototabang of 17,475 μg/Nm3 activity caused by the forest fires in Riau Province. NO2 concentration while the dry season is higher than the rainy season, can be seen from the presence of a decrease in the concentration of 0,583 μg/Nm3 for GAW Bukit Kototabang, 8,902 μg/Nm3 for BMKG Jakarta; 12,306 μg/Nm3 for Ancol; and 2,0139 μg/Nm3 for Glodok. Concentrations of SO2, NO2, and metal Pb in the air when the rainy season decreases due to the deposition of the pollutants in the collection or the cloud and condensed into a liquid form / rain (HNO3 and H2SO4). The best ambient air quality in BMKG Jakarta and worst in Glodok, this corresponds to the number of motor vehicles passing through the area of the sampling point."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
S61316
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>