Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 51413 dokumen yang sesuai dengan query
cover
Hernandia Astika Kusumawati
"Penelitian ini bertujuan untuk menganalisis pengaruh perendaman larutan stroberi terhadap perubahan kekerasan permukaan resin komposit bulk-fill. Total sampel terdiri dari enam puluh spesimen resin komposit Tetric N-Ceram bulk-fill (ketebalan 3 mm dan diameter 6 mm; warna IVB). Spesimen dikelompokan menjadi dua, yaitu kelompok perendaman dalam akuades (kontrol) dan larutan stroberi. Spesimen direndam dalam akuades dan disimpan dalam inkubator bersuhu 37°C selama 24 jam sebagai baseline. Selanjutnya masing-masing kelompok direndam selama 1 hari, 3 hari dan 7 hari (n=10). Setelah perendaman, dilakukan pengukuran nilai kekerasan permukaan menggunakan Micro Vickers Hardness Tester dengan indenter Knoop. Data yang diperoleh dianalisis menggunakan uji One-Way ANOVA. Hasil menunjukan bahwa perendaman dalam akuades dan larutan stroberi selama 1 hari, 3 hari dan 7 hari dapat menurunkan kekerasan permukaan resin komposit bulk-fill secara signifikan (p<0,05). Dapat disimpulkan bahwa derajat keasaman dan durasi perendaman menurunkan kekerasan permukaan resin komposit bulk-fill.

This study aimed to analize the effect of immersion in strawberry solution on surface hardness of bulk-fill composite resin. The total sample consist of sixty Tetric N-Ceram bulk-fill composite resin specimens (thickness 3 mm and diameter 6 mm; shade IVB). Samples were devided into two groups; distilled water as the control group and strawberry solution. Samples were immersed in distilled water and saved in an incubator at 37°C for 24 hours as a baseline. Then samples were alternately immersed for 1 day, 3 days and 7 days (n=10). After immersion, the changes in surface hardness of bulk-fill composite resin were measured using Micro Vickers Hardness Tester with Knoop Indentor. The data obtained were analyzed using One-Way ANOVA. The result showed that immersion in distilled water and strawberry solution for 1 day, 3 days and 7 days can significantly reduced the surface hardness of bulk-fill composit resin. It can be concluded that the acidity degree and immersion duration decrease the surface hardness of bulkfill composire resin."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rigita Ayu Dyah Prawestiningrum
"Penelitian ini bertujuan untuk mengetahui pengaruh perendaman larutan nanas terhadap kekerasan permukaan resin komposit bulk-fill. Enam puluh spesimen resin komposit Tetric®N-Ceram Bulk-Fill shadeIVB berdiameter 6 mm dan tebal 3 mm dibagi menjadi dua kelompok perlakuan, yaitu perendaman dengan aquades sebagai kontrol dan larutan nanas pH: 3,8±0,1(n= 30). Sebelumnya seluruh kelompok direndam terlebih dahulu dalam aquades selama 24 jam dalam inkubator bersuhu 37oC sebagai baseline. Kemudian masing-masing kelompok tadi akan direndam kembali dalam larutan selama 1 hari, 3 hari dan 7 hari (n= 10). Kekerasan permukaan diukur menggunakan HMV-G SeriesVickers Micro Hardness Tester Shimadzu®dengan indenter Knoop. Setiap spesimen akan diindentasi dengan beban sebesar 50 gf, sebanyak 5 kali indentasi. Hasil penelitian menunjukkan bahwa terdapat perbedaan bermakna (p<0,05)antara perendaman 1 hari, 3 hari dan 7 hari pada kelompok perendaman larutan nanas dengan uji One-way ANOVA. Disimpulkan bahwa larutan nanas dapat menurunkan kekerasan permukaan resin komposit bulk-fill.

This study aims to determine effect of pineapple solution immersion on surface hardness of bulk-fill composite resin. Sixty specimens of Tetric®N-Ceram Bulk-Fill composite resin shade IVB, 6 mm in diameter and 3 mm thick were divided into two groups, with immersion in aquades as a control and pineapple solutionpH: 3,8±0,1 (n= 30). Before immersion, all specimens were immersed in aquades for 24 hours and were saved in incubator at 37oC as a baseline.Each group of immersions would be divided into three groups, with immersion for 1 day, 3 days and 7 days (n= 10). The surface hardness was measured using HMV-G Series Vickers Micro Hardness Tester Shimadzu®with Knoop Indenter. Each specimen was indented with load of 50 gf for 5 times. The results showed that there were statistically significant differences (p <0.05) between pineapple solution immersion for 1 day, 3 days and 7 days with One-way ANOVA test. It can be concluded that pineapple solution can reduce surface hardness of bulk-fill composite resin."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Trihanna Kezya Rima
"Penelitian ini bertujuan untuk mengetahui pengaruh perendaman minuman isotonik terhadap kekerasan permukaan resin komposit bulk-fill. Enam puluh spesimen Tetric N-Ceram Bulk-Fill berdiameter 6 mm dan tinggi 3 mm dibagi menjadi 2 kelompok perendaman yaitu dengan akuades (kontrol) dan minuman isotonik. Setiap kelompok direndam dengan lama perendaman 1 hari, 3 hari dan 7 hari. Kekerasan permukaan diuji menggunakan HMV-G Series Micro Vickers Hardness Tester.
Hasil menunjukan terdapat perbedaan bermakna (p<0,05) antara perendaman akuades dan minuman isotonik uji Independent T-Test. Hasil menunjukkan bahwa terdapat perbedaan bermakna (p<0,05) antara semua kelompok perendaman minuman isotonik dengan lama perendaman 1 hari, 3 hari dan 7 hari dengan uji statistik One-Way Anova dan PostHoc Tukey HSD. Dapat disimpulkan bahwa minuman isotonik mempengaruhi kekerasan permukaan resin komposit bulk-fill.

This study aims to determine the influence of isotonic drink immersion on surface hardness of bulk-fill composite. Sixty specimens of Tetric N-Ceram Bulk-Fill, 6 mm in diameter and 3 mm height were divided into two groups of storage media; deionized water (control) and isotonic drink. Each group was for 1 day, 3 days and 7 days. The surface hardness is measured using a HMV-G Series Micro Vickers Hardness Tester.
The results showed that there were significant differences (p <0.05) between immersion of control and isotonic drink with Independet T-Test. The results showed that there were significant differences (p <0.05) between all isotonic drink immersion groups with immersion duration of 1 day, 3 days and 7 days with One-Way Anova Test and Post Hoc Tukey HSD. It can be concluded that isotonic drinks affect the surface hardness of bulk-fill composite.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ayuna Ajeng Ratna
"Penelitian ini bertujuan untuk mengetahui pengaruh lama perendaman dalam saliva buatan terhadap perubahan pH-nya dan kekasaran permukaan resin komposit Giomer Bulk-Fill. Jumlah spesimen 63 buah dibagi dalam sembilan kelompok perlakuan yaitu perendaman dalam saliva buatan pH 7; 5,5; dan 4,5 selama masing-masing 1 jam, 24 jam, dan 72 jam pada suhu 370C. Perubahan pH saliva buatan diukur menggunakan pH meter dan pengujian kekasaran permukaan spesimen menggunakan surface roughness tester. Hasil menunjukkan bahwa terdapat perbedaan yang bermakna pada setiap kelompok perlakuan.

This study aimed to determine the effect of immersion time on artificial saliva pH changes and surface roughness of Giomer Bulk Fill composite resin. Sixty three specimens were divided into nine groups with immersion in artificial saliva pH 7, 5.5, and 4.5 for 1 hour, 24 hours, and 72 hours at 370C respectively. The changes in artificial saliva pH were measured using a pH meter and the surface roughness measured using surface roughness tester. The results showed that there were significant differences between each groups."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Marcella Lydia
"Latar Belakang: Resin komposit Giomer Bulk-Fill merupakan resin komposit yang dapat ditumpat hingga ketebalan 4 mm dan dapat melepas ion fluor. Resin komposit ini juga menjadi buffer asam ketika tingkat pH saliva turun dan mengembalikan ke pH netral. Namun, kenaikan pH diikuti dengan penurunan sifat fisik dari material. Belum diketahui apakah terdapat pengaruh terhadap kekerasan permukaan setelah material ini melepas fluor dan perubahan pH saliva.
Tujuan: Untuk mengetahui pengaruh perbedaan pH saliva buatan dan lama perendaman terhadap kekerasan permukaan resin komposit Giomer Bulk-Fill.
Metode: Penelitian eksperimental laboratorik menggunakan sembilan puluh spesimen resin komposit Giomer Bulk-Fill berdiameter 6 mm dan tinggi 3 mm dibagi menjadi 9 kelompok perendaman yaitu dengan saliva buatan pH 7 (kontrol); pH 5,5; pH 4,5 dengan lama perendaman 1 jam, 24 jam, dan 72 jam yang disimpan dalam inkubator dengan suhu 37°C. Uji kekerasan menggunakan Knoop Microhardness Tester (Shimadzu HMV-G21DT, Jepang).
Hasil: Berdasarkan hasil uji statistik One-way ANOVA terdapat perbedaan bermakna (p<0,05) antara kelompok perendaman dalam saliva buatan pH 4,5 dengan kelompok perendaman dalam saliva buatan pH 5,5 dan kelompok perendaman dalam saliva buatan pH 4,5 dengan kelompok perendaman dalam saliva buatan pH 7 yang dilakukan perendaman selama 72 jam. Nilai kekerasan pada perendaman dengan saliva buatan pH 4,5 dan lama perendaman 1 jam, 24 jam, dan 72 jam beruturut-turut sebesar 35,9±2,40 KHN, 33,75±2,98 KHN, dan 32,7±2,71 KHN. Sementara itu, nilai kekerasan dengan saliva buatan pH 5,5 dan lama perendaman 1 jam, 24 jam, dan 72 jam beruturt-turut sebesar 38,92±2,96 KHN, 37,00±1,82 KHN, dan 38,6±3,42 KHN. Dengan larutan saliva buatan pH 7 dan lama perendaman 1 jam, 24 jam, dan 72 jam didapatkan nilai kekerasan berturut-turut adalah 37,01±2,21 KHN, 37,05±1,79 KHN dan 37,72±2,51 KHN.
Kesimpulan: Lama perendaman dan tingkat keasaman dalam saliva buatan dapat menurunkan nilai kekerasan permukaan resin komposit Giomer Bulk-Fill.

Introduction: Composite resin Giomer Bulk-Fill is a material for restoration that can be placed in single increment with depth until 4 mm and release fluoride ion. This composite resin can be an acidic buffer when pH saliva drops and turns it back to pH neutral. However, the physical properties of the material are decreased. It is unknown if there any change of surface hardness of the material due to fluoride ion release and changes in pH saliva.
Objective: This study aimed to determine the effect of immersion time and different pH levels of artificial saliva on surface microhardness of composite resin Giomer Bulk-Fill.
Methods: Laboratory experimental research using ninety specimens of resin composite Giomer Bulk-Fill and divided into nine groups with immersion in artificial saliva pH 7 (control); 5,5; and 4,5 for 1, 24, and 72 hours at 37°C respectively and tested using Knoop Microhardness Tester (Shimadzu HMV-G21DT, Japan).
Result: The statistical test using One-way ANOVA showed that there were significant differences (p<0,05) between group of immersion in artificial saliva pH 4,5 compared to group of immersion in artificial saliva pH 5,5 and group of immersion in artificial saliva pH 5,5 compared to group of immersion in artificial saliva pH 7 for 72 hours of immersion. The result showed that the hardness number of the groups immersed in artificial saliva pH 4,5 for 1 hour, 24 hours, and 72 hours respectively are 35,9±2,40 KHN, 33,75±2,98 KHN, and 32,7±2,71 KHN. Meanwhile, the hardness number of the groups immersed in artificial saliva pH 5,5 for 1 hour, 24 hours, and 72 hours respectively 38,92±2,96 KHN, 37,00±1,82 KHN, and 38,6±3,42 KHN. The hardness number of the groups immersed in aritificial saliva of pH 7 for 1 hours, 24 hours, and 72 hours are 37,01±2,21 KHN, 37,05±1,79 KHN dan 37,72±2,51 KHN.
Conclusion: Different immersion times and pH levels decrease surface microhardness of Giomer Bulk-Fill composite resin.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alamsyah Putra
"Latar belakang : Resin komposit bulkfill merupakan resin terbaru yang dapat direstorasi dengan kedalaman 4-5 mm dalam sekali penyinaran. Polimerisasi dipengaruhi oleh durasi penyinaran dan besaran irradiansi lightcuring untuk mendapatkan kekerasan permukaan dan depth of cure yang optimal. Tujuan: Penelitian ini bertujuan untuk mengetahui perbedaan nilai kekerasan resin komposit dan depth of cure resin komposit Tetric® N- Ceram bulk-fill yang disinari lightcure dengan durasi 5 detik, 10 detik dan 15 detik. Metode Penelitian: Dalam penelitian ini digunakan 24 spesimen resin komposit Tetric® N-Ceram bulk-fill berbentuk silinder dengan ukuran diameter 6 mm dan tebal 4 mm. Selembar mylar strip diletakkan diatas permukaan resin komposit sebelum dilakukan proses curing. Polimerisasi dilakukan menggunakan Light Curing Unit (LED DBA iLed) selama 5 detik, 10 detik dan 15 detik dengan irradiansi 1100 mW/cm2. Setelah polimerisasi, spesimen direndam dalam akuades pada suhu 37oC selama 24 jam. Spesimen dibagi menjadi tiga kelompok (n=8) yaitu; kelompok resin komposit dengan penyinaran 5 detik, penyinaran 10 detik dan penyinaran 15 detik. Spesimen diuji menggunakan HMV-G Series Micro Vickers Hardness Tester (Shimadzu, Jepang) dengan beban 100 gram selama 10 detik untuk mendapatkan nilai kekerasan. Data dianalisis dengan uji statistik Kruskall Wallis dan Post-Hoc Mann Whitney. Hasil Penelitian: Hasil uji statistik menunjukkan kenaikan bermakna nilai kekerasan permukaan dan depth of cure pada resin komposit Tetric® N-Ceram bulk-fill. Nilai kekerasan dan depth of cure tertinggi terlihat pada resin komposit Tetric® N-Ceram bulk-fill pada kelompok penyinaran 15 detik, yaitu sebesar 41,61 ± 1,25 KHN dan 72,71 ± 1,88. Kesimpulan: Disimpulkan bahwa semakin bertambah durasi penyinaran lightcure yang disinari, semakin bertambah nilai kekerasan permukaan dan depth of cure resin komposit Tetric® N-Ceram bulk-fill.

Background : Bulkfill composite resin is the newest resin that can be restored to a depth of 4-5 mm in one step. Polymerization is determined by the irradiation time and the amount of light curing irradiance to obtain optimal microhardness and depth of cure. Objective: The aim of this study was to determine the difference in the value of the microhardness of the composite resin and the depth of cure of the Tetric® N-Ceram bulk- fill composite resin irradiated by lightcure with a duration of 5 seconds, 10 seconds and 15 seconds. Method: Twenty four specimens of Tetric® N-Ceram bulk-fill Composite Resin were used in this study. All materials were prepared into disk-shaped specimens of 6 mm in diameter and 4 mm in thickness. A piece of mylar strip was placed on the top of the specimens just before the polymerization.. Polymerization was carried out using a Light Curing Unit (LED DBA iLed) for 5 seconds, 10 seconds and 15 seconds with an irradiance of 1100 mW/cm2. After polymerization, specimens were immersed in 37 aquadest solution for 24 hours. Specimens were divided into three groups (n=8) that is; composite resin group with 5 seconds of irradiation, 10 seconds of irradiation and 15 seconds of irradiation. Specimens were tested with HMV-G Series Micro Vickers Hardness Tester (Shimadzu, Jepang) with 100 gram indentation in 10 seconds. Data were analyzed using Kruskall Wallis and Post-Hoc Mann Whitney to assess the significant differences among groups Result: The results of statistical tests showed a significant increase in the value of microharhardness and depth of cure on Tetric® N-Ceram bulk- fill composite resin. The highest microhardness and depth of cure values were seen in the Tetric® N-Ceram bulk-fill composite resin in the 15 second irradiation group, namely 41.61 ± 1.25 KHN and 72.71 ± 1.88. Conclusion: It was concluded that the longer the duration of irradiation of the irradiated lightcure, the higher the microhardness value and depth of cure of the Tetric® N-Ceram bulk-fill composite resin."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Margaretha Claresta Borris Agrippina
"Tujuan :Penelitian bertujuan untuk mengetahui pengaruh aplikasi gel acidulated
phosphate fluoride terhadap perubahan warna material restoratif resin komposit bulk-fill
flowable yang direndam dalam larutan kopi. Metode penelitian: Dua puluh spesimen
resin komposit bulk-fill flowable berbentuk silinder berdiameter 6 mm dengan tebal 2 mm
disiapkan kemudian dibagi menjadi 2 kelompok, dengan salah satu kelompok menerima
aplikasi gel APF dan kelompok lainnya tidak. Setelah diberikan aplikasi gel, spesimen
kemudian direndam di dalam larutan kopi (37oC) selama 7 hari. Pengukuran warna
dilakukan dengan colorimeter pada saat sebelum perlakuan, setelah aplikasi gel APF dan
setelah perendaman di dalam larutan kopi, kemudian dihitung nilai perubahan warnanya
sesusai sistem CIE Lab. Analisis data menggunakan uji statistik Independent T-Test
untuk menilai perbedaan perubahan warna antara kelompok dengan dan tanpa aplikasi
gel APF. Hasil: Hasil menujukkan kelompok yang menerima gel APF mengalami
perubahan warna yang lebih besar (p>0.05) daripada kelompok tanpa gel APF.
Kesimpulan : Dari hasil penelitian, disimpulkan bahwa aplikasi gel APF memiliki
pengaruh terhadap perubahan warna pada resin komposit bulk-fill flowable

Objective: The aim of this study was to determine the effect of application of
acidulated phosphate fluoride gel on the color change of bulk-fill flowable composite
resin restorative material immersed in coffee. Methods: Twenty specimens of bulk-fill
flowable composite resin in the form of cylinders 6 mm in diameter and 2 mm in thickness
were prepared and then divided into 2 groups, with one group receiving APF gel
application and the other group not. After being given the gel application, the specimens
were then immersed in a coffee solution (37oC) for 7 days. Color measurement was
carried out with a colorimeter before treatment, after application of APF gel and after
immersion in coffee solution, then the value of the color change was calculated according
to the CIE Lab system. Data was analyzed using the independent T-Test statistical test to
assess differences in color change between groups with and without APF gel application.
Results: The results showed that the group that received the APF gel had a greater color
change (p> 0.05) than the group without APF gel application. Conclusion: From the
results of the study, it was concluded that the application of APF gel had an effect on the
color change of the flowable bulk-fill composite resin.
"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rivandy Holil
"Latar Belakang: Dalam dunia kedokteran gigi, terdapat banyak pilihan material restoratif yang dapat digunakan, salah satunya yaitu resin komposit. Seiring dengan perkembangan teknologi, para peneliti berhasil mengembangakan resin komposit baru yaitu Bulk-Fill. Sebagai contoh adalah resin komposit Giomer Bulk-Fill yang memiliki berbagai sifat seperti sifat mekanik, fisis dan biologis. Namun, belum ada penelitian pada resin komposit Giomer Bulk-Fill yang secara spesifik menguji nilai kekuatan tarik diametral yang merupakan salah satu sifat mekanik material restoratif.
Tujuan Penelitian: Penelitian ini bertujuan untuk mengetahui pengaruh lama perendaman 1, 24, dan 72 jam serta perbedaan nilai pH saliva buatan 7; 5,5; dan 4,5 terhadap kekuatan tarik diametral resin komposit Giomer Bulk-Fill.
Metode: Penelitian eksperimental laboratorik dengan menggunakan 90 spesimen berbentuk silindris pejal dengan diameter 6 mm dan tinggi 3 mm yang diuji menggunakan Universal Testing Machine (Shimadzu AGS-X 5kN, Japan) dan dibagi ke dalam 3 kelompok pH larutan saliva buatan yaitu 7; 5,5; dan 4,5; serta 3 kelompok lama perendaman yaitu 1, 24, dan 72 jam.
Hasil: Hasil pengujian menggunakan uji One-way ANOVA menunjukkan adanya perbedaan bermakna pada spesimen-spesimen yang digunakan (p<0,05). Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 7, hasil rerata kekuatan tarik diametral pada perendaman selama 1 jam adalah sebesar 36,7 ± 2,7 MPa. Kemudian mengalami penurunan setelah perendaman 24 jam dengan rerata nilai kekuatan tarik diametralnya sebesar 35,2 ± 2,2 MPa dan meningkat kembali setelah perendaman 72 jam dengan hasil rerata kekuatan tarik diametralnya sebesar 40,1 ± 3,6 MPa. Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 4,5, pada perendaman selama 1 jam hasil rerata kekuatan tarik diametralnya sebesar 33,6 ± 2,4 MPa. Kemudian setelah perendaman 24 jam dan 72 jam meningkat menjadi 42,6 ± 2 MPa dan 44,2 ± 2,8 MPa. Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 5,5, hasil rerata kekuatan tarik diametral setelah perendaman selama 1 jam adalah sebesar 34 ± 2,4 MPa. Namun, terjadi perbedaan jika dibandingkan dengan kelompok pH 4,5 yaitu pada kelompok dengan pH 5,5 pada lama perendaman 24 jam terjadi peningkatan yaitu sebesar 44,7 ± 2,8 MPa kemudian menurun setelah perendaman 72 jam dengan nilai rerata sebesar 39 ± 3,3 MPa.
Kesimpulan: Nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill tidak dipengaruhi oleh pH saliva buatan 4,5; 5,5; dan 7 yang digunakan di dalam penelitian ini. Nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill yang direndam selama 1, 24, dan 72 jam di dalam saliva buatan dengan pH 4,5; 5,5; dan 7 secara umum mengalami peningkatan sehingga lama perendaman dalam penelitian ini mempengaruhi nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill.

Background: In the world of dentistry, there are many choices of restorative materials that can be used, one of them is composite resin. Along with the development of technology, the researchers succeeded in developing a new composite resin called Bulk-Fill. One example is Giomer Bulk-Fill composite resin which has various properties such as mechanical, physical and biological properties. However, there is no research on Giomer Bulk-Fill composite resin which specifically tests the value of diametral tensile strength which is one of the mechanical properties of restorative material.
Objective: This study aims to determine the effect of immersion time and the difference in pH value 7; 5,5; and 4,5 of the artificial saliva solution on the value of diametral tensile strength of Giomer Bulk-Fill composite resin.
Method: Laboratory experimental research using 90 solid cylindrical specimens with a diameter of 6 mm and a height of 3 mm which were tested using Universal Testing Machine (Shimadzu AGS-X 5kN, Japan) and were divided into 3 groups pH of artificial saliva solution (7; 5.5; and 4.5) and 3 groups of immersion periods (1, 24 and 72 hours).
Results: The test results using the One-way ANOVA test showed significant differences in the specimens used (p <0.05). In the group of specimens which were immersed in artificial saliva solution with pH 7, the results of the average diametral tensile strength at immersion for 1 hour were 36.7 ± 2.7 MPa. Then it decreased for 24 hours immersed time with a mean value of diametral tensile strength of 35.2 ± 2.2 and increased again at 72 hours immersed time with an average value of diametral tensile strength 40.1 ± 3.6 MPa. In the group of specimens which were immersed in artificial saliva solution with pH 4.5, at immersion for 1 hour the average value of diametral tensile strength was 33.6 ± 2.4 MPa. Then in 24-hour and 72-hour immersion, it increased to 42.6 ± 2 MPa and 44.2 ± 2.8 MPa. In the group of specimens immersed in artificial saliva solution with a pH of 5.5, the average value of diametral tensile strength for 1 hour was 34 ± 2.4 MPa. However, there was a difference when compared to the pH 4.5 group, which was in the group with a pH of 5.5 in the 24-hour immersion period, the value increase for 44.7 ± 2.8 MPa and then decreased for 72 hours of immersion with an average value of 39 ± 3.3 MPa.
Conclusion: The value of diametral tensile strength of Giomer Bulk-Fill composite resin is not affected by pH of artificial saliva 4.5; 5.5; and 7 that used in this study. The value of diametral tensile strength of Giomer Bulk-Fill composite resin, which is immersed for 1, 24, and 72 hours in artificial saliva with pH 4.5; 5.5 and 7 generally increased so that the immersion time in this study affected the diametral tensile strength of Giomer Bulk-Fill composite resin.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rifdah Yunerizka Fatma
"Latar belakang: Mode penyinaran pulsa merupakan alternatif dari mode penyinaran kontinu untuk mempolimerisasi resin komposit. Saat ini resin komposit nanofil dan bulkfil merupakan material restorasi yang memerlukan surface gloss yang baik untuk memenuhi kebutuhan estetik. Surface gloss dapat dipengaruhi oleh penyinaran.
Tujuan: Untuk menganalisa pengaruh penyinaran mode kontinu dan pulsa terhadap surface gloss resin komposit nanofil dan bulkfil segera dan setelah satu hari.
Metode: Spesimen resin komposit nanofil dan bulkfil disinar menggunakan mode kontinu atau pulsa beriradiansi 900 mW/cm2 selama 20 detik. Lalu dilakukan pengujian surface gloss segera setelah penyinaran. Kemudian spesimen disimpan selama satu hari dan dilakukan pengujian surface gloss kembali.
Hasil: Surface gloss yang dihasilkan oleh mode penyinaran kontinu dan pulsa tidak bermakna secara statistik (p>0,05). Resin komposit nanofil menghasilkan surface gloss lebih rendah daripada bulkfil, berbeda bermakna (p=0,00). Segera setelah penyinaran menghasilkan surface gloss lebih tinggi daripada setelah satu hari tidak bermakna secara statistik (p>0,05).
Kesimpulan: Pada penelitian ini surface gloss tidak dipengaruhi oleh mode penyinaran kontinu dan pulsa serta perbedaan waktu segera dan setelah satu hari. Namun terdapat pengaruh jenis resin komposit, nanofil menghasilkan surface gloss lebih rendah dari yang dihasilkan bulkfil.

Background: Pulse is an alternative of continuous light-curing mode to polymerize composite resin. Currently, nanofill and bulk-fill are restorative materials that require good gloss surface to meet aesthetic needs. Surface gloss can be obtained by irradiation.
Aim: To analyze influence of continuous and pulse light-curing mode on surface gloss of nanofill and bulk-fill immediately after irradiation and after one day.
Method: Nanofill and bulk-fill specimens were irradiated using continuous or pulse light-curing mode with irradiance of 900 mW/cm2 for 20 seconds. Then surface gloss test is carried out immediately after irradiation. Then the specimens were water-stored for one day and then tested their surface gloss again.
Result: Surface gloss produced by continuous and pulse light-curing mode were not statistically different (p>0,05). Nanofill produced lower surface gloss than bulk-fill, statistically significant (p=0,00). Immediately after irradiation, resulting surface gloss were higher than after one day, not statistically significant (p>0,05).
Conclusion: In this experiment, surface gloss was not affected by continuous and pulse light-curing mode as well as the time difference immediately and after one day. However, there is an influence on the type of composite resin, where nanofill produced lower surface gloss than bulk-fill.
"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Konita Nur Khasanah
"Tujuan penelitian ini untuk mengetahui pengaruh penggunaan sumber sinar berbeda terhadap kekuatan tarik diametral resin komposit bulk-fill. Resin komposit bulk-fill Tetric N-Ceram Bulk Fill dibuat sebanyak 20 spesimen berbentuk lempeng dengan diameter 6 mm dan tebal 3 mm. Spesimen dibagi menjadi dua kelompok yaitu kelompok yang disinari dengan sumber sinar QTH dan sumber sinar LED. Uji kekuatan tarik diametral dilakukan dengan menggunakan Universal Testing Machine. Hasil penelitian menunjukkan nilai rerata kekuatan tarik diametral resin komposit bulk-fill yang disinari sumber sinar QTH dan LED sebesar 38.62 2.34 dan 42.02 3.21. Hasil uji independent sample T menunjukkan nilai rerata pada kedua kelompok berbeda bermakna.

This study aimed to evaluate the effect of using different light sources on the diametral tensile strength of bulk fill resin composite. Bulk fill resin composite Tetric N Ceram Bulk Fill was used to make of 20 disc shape specimens with 6 mm in diameter and 3 mm in thickness. Specimens were divided into two groups, the two groups were polymerized with using QTH and LED light source curing unit. Diametral tensile strength test was conducted by using a Universal Testing Machine Shimadzu, Japan. The results showed that diametral tensile strength mean value of bulk fill resin composite that were cured with QTH and LED light source were 38.62 2.34 and 42.02 3.21 MPa respectively. Independent sample t test results showed that the mean value of the two groups was significantly different."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>