Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 92325 dokumen yang sesuai dengan query
cover
Aulia Yasmin
"Latar Belakang: Alginat merupakan salah satu bahan cetak kedokteran gigi yang dapat menjadi sumber potensial kontaminasi silang, sehingga harus dilakukan desinfeksi tanpa menyebabkan distorsi pada sifat fisik alginat seperti perubahan dimensi, reproduksi detail, dan kompatibilitas dengan gipsum. Saat ini beredar alginat buatan Indonesia dan belum ada penelitian mengenai sifat fisik alginat buatan Indonesia setelah dilakukan desinfeksi perendaman. Tujuan: Mengetahui pengaruh desinfeksi perendaman dalam larutan natrium hipoklorit (NaOCl) 0,5%, glutaraldehid 2%, dan klorheksidin 0,2% pada bahan cetak alginat buatan Indonesia (Hexalgin) dan luar negeri (GC Aroma Fine Plus Normal Set) terhadap perubahan dimensi, reproduksi detail, dan kompatibilitas dengan gipsum. Metode: Masing-masing 20 spesimen alginat buatan Indonesia dan luar negeri dibuat sesuai dengan standar ISO 1563 dan dibagi menjadi kelompok desinfeksi perendaman dalam larutan NaOCl 0,5%, glutaraldehid 2%, klorheksidin 0,2%, dan kontrol lalu dilakukan pengecoran dengan gipsum tipe III. Pengujian dilakukan sesuai standar ISO 1563 dan ISO 21563, diukur dengan kaliper digital dan dinilai dengan kamera digital dengan perbesaran 6,3X. Analisis data dengan uji statistik One Way ANOVA dan uji Pearson Chi-Square. Hasil: Rerata perubahan dimensi antara kelompok perlakuan perendaman dalam larutan disinfektan berbeda pada alginat buatan Indonesia dan luar negeri menunjukkan perbedaan bermakna (p<0,05). Rerata perubahan dimensi antara alginat buatan Indonesia dengan buatan luar negeri setelah desinfeksi perendaman dalam berbagai larutan tidak berbeda bermakna (p≥0,05), kecuali pada kelompok klorheksidin 0,2%. Secara berurutan, nilai rerata perubahan dimensi pada hasil cetakan alginat buatan Indonesia dan alginat buatan luar negeri setelah desinfeksi perendaman dalam NaOCl 0,5% adalah 0,126±0,035% dan 0,089±0,015%, glutaraldehid 2% adalah 0,162±0,036% dan 0,128±0,026%, klorheksidin 0,2% adalah 0,204±0,029% dan 0,131±0,023% dan kontrol adalah -0,025±0,011% dan -0,014± 0,009%. Proporsi reproduksi detail menunjukkan hasil yang sama pada seluruh spesimen, yaitu dapat mereproduksi detail. Skor kompatibilitas dengan gipsum menunjukkan skor 1, 2, dan 3. Proporsi skor kompatibilitas dengan gipsum antar kelompok perlakuan serta antara alginat buatan Indonesia dan luar negeri tidak berbeda bermakna (p≥0,05). Kesimpulan: Alginat buatan Indonesia setelah desinfeksi perendaman dalam larutan NaOCl 0,5%, glutaraldehid 2%, dan klorheksidin 0,2% mengalami perubahan dimensi yang dapat diterima secara klinis, dapat mereproduksi detail dengan baik, dan kompatibel dengan gipsum tipe III.

Background: Alginate is one of dental impression materials that can be a potential source of cross-contamination, so disinfection must be carried out without causing distortion on the physical properties of alginate such as dimensional changes, detail reproduction, and compatibility with gypsum. Currently, Indonesian-made alginate has been circulating in Indonesia and there has been no research on the physical properties of Indonesian-made alginate after immersion disinfection. Objective: To determine the effect of immersion disinfection in 0.5% sodium hypochlorite (NaOCl), 2% glutaraldehyde, and 0.2% chlorhexidine between Indonesian-made (Hexalgin) and foreign-made (GC Aroma Fine Plus Normal) alginate impression on dimensional changes, detail reproduction and compatibility with gypsum. Methods: 20 Indonesian-made and foreign-made alginate specimens were made according to the ISO 1563 standard and grouped into disinfection by immersion in 0.5% NaOCl, 2% glutaraldehyde, 0.2% chlorhexidine solution, and control and then cast with type III gypsum. Tests were carried out according to ISO 1563 and ISO 21563 standards, measured with digital calipers and assessed with a digital camera with 6.3X magnification. Data analysis with One Way ANOVA test and Pearson Chi-Square test. Results: The mean dimensional changes between treatment groups (immersion in different disinfectant solutions) on Indonesian-made and foreign-made alginates showed a significant difference (p<0.05). The mean dimensional change between Indonesian-made and foreign-made alginate after disinfection by immersion in different solutions was not significantly different (p≥0.05), except for the 0.2% chlorhexidine group. The mean value of dimensional changes in the Indonesian-made and foreign-made alginate impressions after disinfection by immersion in NaOCl 0.5% are 0.126±0.035% and 0.089±0.015%, glutaraldehyde 2% are 0.162±0.036% and 0.128±0.026%, chlorhexidine 0.2% are 0.204±0.029% and 0.131±0.023%, and control are -0,025±0,011 % and -0,014±0,009 %. The proportion of detail reproduction of all specimens showed same results, details were reproduced. The compatibility with gypsum scores showed a score of 1,2, and 3. Proportion of compatibility with gypsum scores between treatment groups and between Indonesian-made and foreign-made alginates were not significantly different (p≥0.05). Conclusion: Indonesian-made alginate after disinfection by immersion in 0.5% NaOCl, 2% glutaraldehyde, and 0.2% chlorhexidine solutions undergo dimensional changes that were clinically acceptable, could reproduce details well, and were compatible with gypsum type III."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Elsa Dara Aullia
"Latar Belakang: Alginat mengandung mikroorganisme akibat paparan dari rongga mulut sehingga perlu prosedur desinfeksi. Desinfeksi dapat mempengaruhi sifat fisik seperti stabilitas dimensi, reproduksi detail dan kompatibilitas dengan gipsum. Indonesia telah memproduksi bahan cetak alginat sendiri. Belum ada penelitian mengenai pengaruh teknik desinfeksi penyemprotan terhadap sifat fisik alginat buatan Indonesia. Tujuan: Mengetahui perbedaan pengaruh teknik desinfeksi penyemprotan dengan larutan Natrium hipoklorit (NaOCl) 0,5%, Glutaraldehid 2% dan Klorheksidin 0,2% antara bahan cetak alginat buatan Indonesia (Hexalgin) dan buatan luar negeri (GC Aroma Fine Plus Normal Set) terhadap stabilitas dimensi, reproduksi detail dan kompatibilitasnya dengan gipsum (dental stone). Metode: Pembuatan 20 spesimen alginat buatan Indonesia dan 20 spesimen alginat buatan luar negeri mengikuti standar ISO 1563 dibagi ke dalam 4 kelompok perlakuan desinfeksi penyemprotan yaitu dengan NaOCl 0,5%, Glutaraldehid 2%, Klorheksidin 0,2% dan Kontrol kemudian didiamkan dalam kantung plastik zip lock selama 10 menit. Pengecoran dengan dental stone tipe III. Perubahan dimensi, reproduksi detail, dan kompatibilitas dengan gipsum diuji sesuai standar ISO 1563 dan 21563 dan diukur menggunakan kaliper digital dan dinilai dengan kamera digital dengan perbesaran 6,3x. Analisis data dengan uji statistik One Way Anova dan uji Pearson Chi-Square. Hasil: Rerata perubahan dimensi antara kelompok perlakuan desinfeksi penyemprotan dengan larutan disinfektan berbeda menunjukkan berbeda makna secara statistik (p<0,05) pada alginat buatan Indonesia maupun alginat buatan luar negeri. Rerata perubahan dimensi antara alginat buatan Indonesia dengan alginat buatan luar negeri tidak berbeda makna secara statistik (p≥0,05). Rerata perubahan dimensi pada hasil cetakan alginat buatan Indonesia dan buatan luar negeri secara berurutan setelah desinfeksi penyemprotan dengan NaOCl 0,5% (0,030±0,011% dan 0,016±0,011%), Glutaraldehid 2% (0,055±0,013% dan 0,041±0,013%), Klorheksidin 0,2% (0,078±0,015% dan 0,064±0,011%) dan Kontrol (0,011±0,011% dan 0,011±0,011%). Proporsi reproduksi detail dan kompatibilitas dengan gipsum konstan, yaitu seluruh garis tereproduksi dan kompatibilitas dengan skor 2. Kesimpulan: Perubahan dimensi alginat buatan Indonesia setelah desinfeksi penyemprotan dengan NaOCl 0,5%, Glutaraldehid 2%, dan Klorheksidin 0,2% dapat diterima secara klinis, mereproduksi detail dengan baik, dan kompatibel dengan dental stone tipe III. Desinfeksi dengan NaOCl 0,5% memberikan perubahan dimensi yang paling kecil.

Background: Alginate contains microorganisms due to exposure from the oral cavity, so it needs a disinfection procedure. Disinfection can affect physical properties such as dimensional stability, reproduction of details and compatibility with gypsum. Indonesia has produced its own alginate impression material. There has been no research on the effect of spraying disinfection techniques on the physical properties of Indonesian-made alginates. Objective: Determine the difference in the effect of spraying disinfection techniques with 0.5% sodium hypochlorite, 2% glutaraldehyde and 0.2% chlorhexidine between alginate impression materials made in Indonesia (Hexalgin) and alginate made in foreign countries (GC Aroma Fine Plus Normal Set) on dimensional stability, detail reproduction and compatibility with gypsum (dental stone). Methods: The manufacture of 20 specimens of alginate made in Indonesia and 20 specimens of alginate made in foreign countries following the ISO 1563 standard were divided into 4 spraying disinfection treatment groups, namely 0.5% NaOCl, 2% Glutaraldehyde, 0.2% Chlorhexidine and Control then left in a zip plastic bag lock for 10 minutes. Casting with dental stone type III. Dimensional changes, detail reproduction and compatibility with gypsum were tested according to ISO 1563 and 21563 standards and measured using digital calipers and assessed with a digital camera at 6.3x magnification. Data analysis with One Way Anova and Pearson Chi-Square statistical test. Results: The mean dimensional change between the spraying disinfection treatment groups with different disinfectant solutions showed statistically different meanings (p<0.05) for alginates made in Indonesia and foreign countries. The mean change in dimensions between alginate made in Indonesia and foreign countries did not differ in statistical significance (p≥0.05). The mean dimensional changes in the results of alginate impressions made in Indonesia and foreign countries after disinfection by spraying with 0.5% NaOCl (0.030±0.011% and 0.016±0.011%), Glutaraldehyde 2% (0.055±0.013% and 0.041±0.013%), Chlorhexidine 0.2% (0.078±0.015% and 0.064±0.011%) and Control (0.011±0.011% and 0.011±0.011%). The proportion of detail reproduction and compatibility with gypsum is constant, the entire line is reproduced and compatibility with a score of 2. Conclusion: Changes in the dimensions of alginate made in Indonesia after spray disinfection with 0.5% NaOCl, 2% Glutaraldehyde, and 0.2% Chlorhexidine are clinically acceptable, reproduce details well, and were compatible with dental stone type III. Disinfection with 0.5% NaOCl gave the smallest dimensional change."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Cika Radezky
"Latar Belakang: Alginat adalah salah satu bahan cetak kedokteran gigi yang paling sering digunakan. Sifat fisik alginat, seperti reproduksi detail, kompatibilitasnya dengan gipsum, dan perubahan dimensi, dapat dipengaruhi waktu penundaan pengecoran. Belum ada studi yang menguji sifat fisik alginat buatan Indonesia jika dibandingkan dengan alginat yang diproduksi di luar negeri. Tujuan: Mengetahui perbedaan reproduksi detail dan kompatibilitas dengan gipsum serta perubahan dimensi antara bahan cetak alginat buatan Indonesia (Hexalgin) dengan bahan cetak alginat buatan luar negeri (GC Aroma Fine Plus Normal Set) jika pengecorannya dengan dental stone ditunda selama 10 menit, 20 menit, dan 30 menit setelah penyemprotan disinfektan. Metode: 20 spesimen Hexalgin dan 20 spesimen GC Aroma Fine Plus Normal Set dibuat berdasarkan standar ISO 1563. Spesimen didesinfeksi dengan natrium hipoklorit 5,25% dan dibungkus paper towel lembap dalam plastik klip tertutup selama 10 menit, 20 menit, 30 menit, atau segera dibilas. Pengecoran dilakukan dengan menggunakan dental stone tipe III. Perubahan dimensi, reproduksi detail, dan kompatibilitas dengan gipsum diuji sesuai standar ISO 1563 dan ISO 21563, diukur menggunakan kaliper digital serta diamati dengan kamera digital dengan perbesaran 6,3x. Data dianalisis dengan uji One Way Anova dan uji Pearson Chi Square.
Hasil: Rerata perubahan dimensi (%) pada Hexalgin untuk penundaan 10 menit 0,144±0,048, penundaan 20 menit 0,228±0,021, penundaan 30 menit 0,553± 0,042, dan pengecoran segera -0,151±0,031, dan pada GC Aroma Fine Plus Normal Set untuk penundaan 10 menit 0,041±0,018, penundaan 20 menit 0,141±0,021, penundaan 30 menit 0,311±0,026, dan pengecoran segera -0,039±0,034. Rerata perubahan dimensi antara kelompok perlakuan dan antara Hexalgin dengan GC Aroma Fine Plus Normal Set berbeda bermakna (p<0,05). Proporsi reproduksi detail menunjukkan hasil sama yaitu dapat mereproduksi detail. Baik pada alginat Hexalgin maupun GC Aroma Fine Plus Normal Set terdapat skor kompatibilitas dengan gipsum 1, 2, dan 3. Tidak ada spesimen dengan skor 4. Proporsi skor kompatibilitas dengan gipsum Hexalgin dan GC Aroma Fine Plus Normal Set tidak berbeda bermakna (p≥0,05). Proporsi skor kompatibilitas dengan gipsum antara kelompok perlakuan berbeda bermakna (p<0,05). Kesimpulan:Penundaan pengecoran pada bahan cetak alginat buatan Indonesia (Hexalgin) selama 10 menit, 20 menit, dan 30 menit menghasikan perubahan dimensi yang dapat diterima secara klinis, dapat mereproduksi detail dengan baik, dan kompatibel dengan dental stone tipe III.

Background: Alginate is one of the most frequently used dental impression materials. Physical properties of alginate, such as reproduction detail, compatibility with gypsum, and dimensional stability, can be affected by the pouring delay duration. There has been no study about the physical properties of Indonesian-made alginate compared to foreginmade alginate. Objective: To determine the differences in detail reproduction, compatibility with gypsum, and dimensional changes between Indonesian-made alginate impression material (Hexalgin) and foreign-made alginate impression material (GC Aroma Fine Plus Normal Set) if the pouring with dental stone is delayed for 10 minutes, 20 minutes, and 30 minutes after spraying the disinfectant. Materials and Method: 20 specimens of Hexalgin and 20 specimens of GC Aroma Fine Plus Normal Set were made based on ISO 1563 standard. Specimens were disinfected with 5.25% sodium hypochlorite and wrapped in damp paper towels in plastic clips for 10 minutes, 20 minutes, or 30 minutes, or immediately rinsed. Pouring was done using type III dental stone. Dimensional changes, detail reproduction, and compatibility with gypsum were assessed according to ISO 1563 and ISO 21563 standard, measured using digital calipers and a digital camera at 6.3x magnification. Data were analyzed using One Way Anova test and Pearson Chi Square test. Result: The mean dimensional changes (%) on Hexalgin was 0.144±0.048 for 10 minutes delay, 0.228±0.021 for 20 minutes delay, 0.553±0.042 for 30 minutes delay, and -0.151±0.031 for immediate pouring, and for GC Aroma Fine Plus Normal Set it was 0.041±0.018 for 10 minutes delay, 0.141±0.021 for 20 minutes delay, 0.311±0.026 for 30 minutes delay, and -0.039±0.034 for immediate pouring. Mean of dimensional changes between treatment groups and between Hexalgin and GC Aroma Fine Plus Normal Set was significantly different (p<0.05). Proportion of detail reproduction showed constant results, details were reproduced. Both alginates had compatibility with gypsum scores of "
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yunanda Maindra
"ABSTRACT
Penelitian ini bertujuan untuk mengetahui pengaruh lama perendaman terhadap degradasi scaffold HA/alginat 30/70 dan scaffold HA/alginat/kitosan 30/50/20 . Degradasi ditentukan melalui selisih berat sebelum dan setelah perendaman selama 3, 6, 9, 12, atau 24 jam. Hasil penelitian menunjukkan bahwa degradasi scaffold HA/alginat selama 3, 6, 9, 12, atau 24 jam secara berurutan 17,6 1,33; 21,3 0,66; 24,2 1,01; 26,2 1,19 atau 27,6 0,31 dan degradasi scaffold HA/alginat/kitosan dengan lama perendaman yang sama secara berurutan 30,2 0,81; 39,4 0,67; 43,7 0,66; 48,1 0,94; atau 51,5 0,39. Degradasi scaffold HA/alginat dan HA/alginat/kitosan berbeda bermakna.

ABSTRACT
The aim of this study was to determine the effect of immersion time on degradation of HA alginate 30 70 and HA alginate chitosan 30 50 20 scaffolds. Degradation of the scaffold is determined by the difference of weight before and after immersion for 3, 6, 9, 12, or 24 hours. The result showed that degradation of HA alginate scaffold with 3, 6, 9, 12 or 24 hours of immersion time were 17,6 1,33 21,3 0,66 24,2 1,01 26,2 1,19 or 27,6 0,31 and degradation of HA alginate chitosan scaffold with the same immersion time were 30,2 0,81 39,4 0,67 43,7 0,66 48,1 0,94 or 51,5 0,39. HA alginate and HA alginate chitosan scaffolds has significantly different."
2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Kozin
"In order to reduce the dependency on imported products of railway wheels, efforts have been made to produce it in the country. The manufacture of railway wheels is done through a casting process of raw materials originated from used railway wheels. The results of the casting process requires heat treatment processes to improve the mechanical properties in accordance with the standards. This study has begun with the manufacture of test specimens for chemical composition, tensile strength, hardness and microstructure. It is followed by heat treatment processes namely normalizing, flame hardening and tempering. The normalizing process, at a temperature of 850°C with a holding time of 2 hours followed by cooling in the air, has resulted in tensile strength of 906.1 MPa and hardness of 24 HRC. The flame hardening process at a temperature of 800°C with a holding time of 60 seconds followed by water quenching has resulted in hardness of 57.33 HRC. The tempering process at a temperature of 500°C with a holding time of one hour followed by cooling in the air, has resulted in a final surface hardness of 34 to 37 HRC that complies with the railway standard with effective depth of hardening of 10 mm.

Dalam rangka untuk mengurangi ketergantungan terhadap produk impor roda kereta api, maka telah dilakukan usaha untuk membuatnya di dalam negeri. Usaha pembuatan roda kereta api dilakukan melalui proses pengecoran dengan bahan baku dari roda kereta api bekas. Hasil dari proses pengecoran tersebut memerlukan proses perlakuan panas untuk mendapatkan sifat mekanik yang sesuai dengan standar. Penelitian ini diawali dengan pembuatan spesimen untuk pengujian komposisi kimia, kekuatan tarik, kekerasan dan struktur mikro. Selanjutnya dilakukan proses perlakuan panas berupa normalizing, flame hardening dan tempering. Proses normalizing dilakukan pada temperatur 850°C, waktu penahanan selama 2 (dua) jam dan didinginkan di udara menghasilkan kekuatan tarik sebesar 906.1 MPa dan kekerasan 24 HRC. Proses flame hardening pada temperatur 800°C, waktu penahanan 60 detik dengan media pendingin air menghasilkan kekerasan permukaan sebesar 58.35 HRC. Proses tempering pada temperatur 500°C, waktu penahanan selama 1 (satu) jam menghasilkan kekerasan antara 34-37 HRC dengan kedalaman pengerasan efektif sebesar 10 mm."
Depok: Universitas Indonesia, 2012
T31280
UI - Tesis Open  Universitas Indonesia Library
cover
Sri Dwi Aryani
"ABSTRAK
Kitosan dan alginat merupakan polimer mukoadhesif yang dapat digunakan untuk sistem penghantaran obat target kolon. Kitosan memiliki sifat mukoadhesif untuk dapat berikatan dengan musin pada saluran pencernaan sehingga dapat memperlama waktu adsorpsi obat. Senyawa bioaktif mangostin diekstrak dari kulit manggis, kemudian disalut dengan menggunakan polimer kitosan. Proses ekstraksi pada kulit manggis dilakukan dengan metode maserasi. Mikropartikel diperoleh dengan metode gelasi ionic dan taut silang pada variasi konsentrasi komposisi kitosan-alginat. Uji adsorpsi musin pada mikropartikel kitosan-alginat dilakukan dengan metode Mucous Glycoprotein Assay dengan menggunakan reagen Periodic Acid dan Schiff. Mikropartikel dengan berat molekul kitosan rendah dan variasi komposisi kitosan alginat 1:0 memiliki sifat mukoadhesif yang paling tinggi yaitu antara 55-84% musin teradsorp dan nilai zeta potensial 35,1 mV. Mikropartikel yang juga memiliki sifat mukoadhesif adalah mikropartikel dengan berat molekul kitosan rendah dan variasi komposisi kitosan alginat 1:0,25 dengan persentase musin teradsorp sebesar 51 ? 79% dan nilai zeta potensial 31,1 mV.

ABSTRACT
Chitosan and alginate are polymer which has been widely used for drug delivery colon target. Mucoadhesive properties of chitosan can prolong time of drug absorption. Mangostin as bioactive compound obtained from Garcinia mangostana Linn is coated with chitosan. Extraction process used to obtain mangostin is maceration. Microspheres obtained by ionic gelation method with ratio chitosan-alginate variation and chitosan molecular weight variation. The percentage of mucin adsorption on chitosan-alginate microspheres were determined by Mucous Glcycoprotein Assay using Periodic Acid and Schiff reagent. Microparticles with low molecular weight of chitosan and ratio chitosan alginate 1:0 has the highest mucoadhesive properties, between 55-84% mucin adsorption and zeta potential value 35.1 mV. Microparticles with low molecular weight of chitosan and ratio chitosan alginate 1:0.25 also has good mucoadhesive properties with 51-79% mucin adsorption and zeta potential value 31.1 mV.
"
2016
S64078
UI - Skripsi Membership  Universitas Indonesia Library
cover
Eikla Luwlu Yasmina
"Penelitian ini bertujuan untuk mengetahui pengaruh lama perendaman dalam berbagai pH saliva buatan terhadap kekerasan permukaan material restoratif glass hybrid (EQUIA® FORTE Glass Hybrid Restorative System, GC Corporation, Japan). Jumlah spesimen 90 buah terbagi dalam sembilan kelompok perlakuan yaitu perendaman dalam saliva buatan dengan pH 4,5; 5,5; dan 7 dengan waktu perendaman masing-masing 1 jam, 24 jam, dan 72 jam pada suhu 37oC. Uji kekerasan permukaan menggunakan Knoop Microhardness Tester (Shimadzu HMV-G Micro Hardness Tester, Japan) dengan beban 50 gram selama 15 detik sebanyak 5 indentasi pada tiap spesimen. Hasil data dianalisis statistik dengan One-way ANOVA (p<0,05).
Hasil penelitian menunjukkan terdapat perbedaan bermakna pada setiap kelompok perlakuan yaitu nilai kekerasan pada perendaman dengan larutan saliva buatan pH 4,5 dan lama perendaman 1 jam, 24 jam, dan 72 jam berturut-turut adalah sebesar 69,48 0,57 KHN, 54,76 0,23 KHN, dan 42,90 0,41 KHN. Sementara itu, nilai kekerasan dengan saliva buatan pH 5,5 dan lama perendaman 1 jam, 24 jam, dan 72 jam berturut-turut adalah sebesar 75,34 0,32 KHN, 57,45 0,47 KHN, dan 45,84 0,27 KHN. Dengan larutan saliva buatan pH 7 dan lama perendaman 1 jam, 24 jam, dan 72 jam didapatkan nilai kekerasan berturut-turut adalah 82,89 0,68 KHN, 62,49 0,37 KHN, dan 49,84 0,14 KHN. Disimpulkan bahwa dengan menurunnya pH saliva buatan dan semakin lamanya perendaman dapat menurunkan nilai kekerasan permukaan material restoratif glass hybrid.

This study aims to determine the effect of immersion time in various pH of artificial saliva on the surface hardness of glass hybrid restorative materials (EQUIA® FORTE Glass Hybrid Restorative System, GC Corporation, Japan). There were 90 specimens (diameter 6mm, thickness 3mm), and the specimens were divided into nine groups immersed in artificial saliva with pH 4,5; 5,5; and 7 for 1 hour, 24 hours, and 72 hours at 37oC respectively. The surface hardness of each specimens were tested using Knoop Microhardness Tester (Shimadzu HMV-G Micro Hardness Tester, Japan) with 50 grams load for 15 seconds, with 5 indentations on each specimens. The statistical analysis using One-way ANOVA (p<0,05) showed that there were significant differences between each groups.
The result showed that the hardness number of the groups immersed in artificial saliva pH 4,5 for 1 hour, 24 hours, and 72 hours respectively are 69,48 0,57 KHN, 54,76 0,23 KHN, and 42,90 0,41 KHN. Meanwhile, the hardness number of the groups immersed in artificial saliva pH 5,5 for 1 hour, 24 hours, and 72 hours respectively are 75,34 0,32 KHN, 57,45 0,47 KHN, and 45,84 0,27 KHN. With artificial saliva of pH 7 for 1 hour, 24 hours, and 72 hours, the hardness number are 82,89 0,68 KHN, 62,49 0,37 KHN, and 49,84 0,14 KHN. It can be concluded that the lower pH value of artificial saliva and prolonged immersion time can reduce the surface hardness value of glass hybrid restorative materials.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ayu Kamilah
"Kitosan dan alginat merupakan polimer mukoadhesif dapat digunakan untuk sistem penghantaran obat target kolon. Kitosan memiliki sifat mukoadhesif untuk dapat berikatan dengan musin pada saluran pencernaan sehingga dapat memperlama waktu absorbsi obat. Uji adsorpsi musin pada mikrosfer digunakan untuk mengukur kekuatan sifat mukoadhesif dari mikrosfer kitosan-alginat. Mikrosfer diperoleh dengan metode gelasi ionik pada variasi konsentrasi komposisi kitosan-alginat dan variasi berat molekul kitosan. Uji adsorpsi musin pada mikrosfer kitosan-alginat dilakukan dengan metode Mucous Glycoprotein Assay dengan menggunakan reagen Periodic Acid dan Schiff. Dari hasil spektrofotometri visible didapatkan bahwa mikrosfer dengan berat molekul kitosan rendah dan variasi komposisi kitosan alginat 1:0 memiliki sifat mukoadhesif yang paling tinggi yaitu antara 58-86% musin teradsorb. Campuran polimer kitosan-alginat berpotensi untuk dijadikan sistem penghantaran obat mukoadhesif

Chitosan and alginate are polymer which has been widely used for drug delivery colon target. Mucoadhesive properties of chitosan can prolong time of drug absorption. Mucin adsorption on microspheres is used to measure the strength of the mucoadhesive properties of chitosan alginate microspheres. Microspheres obtained by ionic gelation method with ratio chitosan-alginate variation and chitosan molecular weight variation. The percentage of mucin adsorption on chitosan-alginate microspheres were determined by Mucous Glcycoprotein Assay using Periodic Acid and Schiff reagent. Visible Spectrophotometry showed that the microspheres with low molecular weight of chitosan and ratio chitosan alginate 1:0 has the highest mucoadhesive properties, between 58-86% mucin adsorption. Chitosan-alginate polymer has the potential to be used as a mucoadhesive drug delivery systems.
"
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59256
UI - Skripsi Membership  Universitas Indonesia Library
cover
Prima Sony
"Beton aerasi memiliki keunggulan pada densitasnya bila dibandingkan dengan beton biasa. Dengan densitas yang rendah, beton aerasi dapat menghemat biaya dalam sebuah konstruksi seperti perumahan, gedung, dan jalan. Beton aerasi yang sudah diproduksi saat ini adalah beton aerasi dengan proses autoclave untuk proses pematangannya. Proses autoclave cenderung membutuhkan energi dan biaya untuk peralatan yang tinggi, oleh karena itu untuk menekan biaya produksi, dikembangkanlah pembuatan beton aerasi tanpa proses autoclave (NAAC). Sebagai salah satu dari bahan baku utama pembuatan beton aerasi, kapur yang ditambahkan mempengaruhi sifat fisik dan mekanik dari beton aerasi. Penelitian ini difokuskan untuk mengetahui pengaruh penambahan kapur terhadap sifat fisik dan mekanik pada NAAC Penelitian tentang pengaruh penambahan kadar kapur ini meliputi pengujian densitas, kekuatan tekan, struktur makro, struktur mikro dan komposisi kimia. Kadar kapur yang digunakan adalah 12.5 %, 25 %, 37.5%, 50% dan 62.5% dari jumlah semen yang digunakan. Proses pematangan dilakukan pada ruangan terbuka dengan temperatur kurang lebih 27_C. Dari penelitian yang dilakukan, telah dihasilkan beton aerasi dengan rentang densitas 968,25 kg/m3 ? 1163,27 kg/m3 (beton ringan memilki densitas dengan rentang 640 -1600 kg/m3). Densitas terendah, didapat dari sampel kadar kapur 50% kapur dengan nilai 968,25 kg/m3. Kekuatan tekan tertinggi diperoleh dari sampel 25% kapur dengan nilai 3,48 MPa. Secara umum terjadi reaksi antara kapur, semen dan agen pengaerasi yang membentuk pori-pori untuk menurunkan nilai densitas. Pengaruh kapur lebih ke arah kekuatan tekan dengan pembentukan fasa kalsium silikat hidrat.

Aerated concrete has advantage of its density compared with regular concrete. With the low density, aerated concrete can reduce the cost of a construction such as home, building and road. Generally, aerated concrete has been produced with curing process in the autoclave. Curing process in the autoclave needs high energy and cost for equipment investment. Therefore, aerated concrete without curing process in the autoclave has been developed. As an important raw material of the aerated concrete, lime may effect aerated concrete physical and mechanical properties. Thus, this study aims to examine the effect of lime addition to the physical and mechanical properties of Non Autoclave Aerated Concrete (NAAC). The examination of this study consist of density, compressive strength, macrostructure, microstructure and chemical composition test from the sample. Lime content in the sample varied from 12.5 % to 62.5% of the cement content. Curing process was conducted in room pressure and temperature(1 atm and 27_C). The result shows that NAAC was succesfully produced with the density range of 968,25 kg/m3 ? 1163,27 kg/m3(aerated concrete had density range about 640 - 1600 kg/m3). The lowest density of the NAAC was achieved with 50% lime content addition. On the other hand, the highest compressive strength NAAC was reached by addition of 25% lime content. Generally, the reaction among lime, cement and aerating agent form the pores in concrete. The presence of pores can decrease the density of concrete. Lime addition tends to affect the compressive strength with the Calsium Silicate Hydrate formation."
Depok: Fakultas Teknik Universitas Indonesia, 2007
S41705
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hasna Nugrahaningtyas
"Penelitian ini bertujuan untuk mengevaluasi pengaruh penambahan unsur timah (Sn) pada paduan aluminium-seng (Al-Zn) terhadap sifat fisik dan perilaku degradasinya sebagai anoda korban. Anoda korban berbasis Al-Zn dengan variasi penambahan Sn sebesar 0,4%, 0,8%, dan 1,2% dibuat melalui metode pengecoran dan diuji untuk sifat fisik menggunakan mikroskop optik (OM) dan scanning electron microscopy-energy dispersive spectroscopy(SEM-EDS). Hasil penelitian menunjukkan bahwa penambahan  Sn memperkecil ukuran butir paduan, yang berkontribusi pada peningkatan ketahanan terhadap korosi pitting. Pengujian degradasi dilakukan menggunakan pengujian cyclic potentiodynamic polarization(CPDP), electrochemical impedance spectroscopy (EIS), dan electrochemical capacitance (DNV RP-B401). Sampel dengan penambahan Sn sebesar 1,2 wt% memiliki grafik OCP yang paling fluktuatif, yang mengindikasikan bahwa sampel tersebut sulit terepasivasi. Penambahan unsur Sn juga dapat meningkatkan nilai Epitt. Nilai Epitt yang lebih negatif menunjukkan semakin mudah suatu sampel mengalami pitting corrosion. Sampel dengan penambahan unsur Sn sebesar 0,8 wt% memiliki nilai potensial akhir terbesar, tetapi untuk nilai ECC dan consumption rate masih unggul sampel dengan penambahan 1,2wt%, sehingga sehingga performa keseluruhan sampel AlZn1,2Sn lebih baik dalam hal ECC yang lebih tinggi dan laju konsumsi yang lebih rendah, meskipun sampel AlZn1,2Sn memiliki kecenderungan pitting corrosion yang lebih besar dibandingkan sampel AlZn0,8Sn.

This study aims to evaluate the effect of adding tin (Sn) to aluminum-zinc (Al-Zn) alloys on their physical properties and degradation behavior as sacrificial anodes. Al-Zn-based sacrificial anodes with Sn additions of 0.4%, 0.8%, and 1.2% were produced through casting and tested for physical properties using optical microscopy (OM) and scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS). The results indicated that the addition of Sn reduced the grain size of the alloy, contributing to increased resistance to pitting corrosion. Degradation testing was conducted using cyclic potentiodynamic polarization (CPDP), electrochemical impedance spectroscopy (EIS), and electrochemical capacitance (DNV RP-B401). The sample with a 1.2 wt% Sn addition had the most fluctuating OCP graph, indicating difficulty in repassivation. The addition of Sn also increased the Epitt value. A more negative Epitt value indicates that the sample is more prone to pitting corrosion. The sample with 0.8 wt% Sn addition had the highest final potential value, but for ECC and consumption rate, the sample with 1.2 wt% addition was superior. Therefore, the overall performance of the AlZn1.2Sn sample is better in terms of higher ECC and lower consumption rate, despite having a greater tendency for pitting corrosion compared to the AlZn0.8Sn sample."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>