Hasil Pencarian

Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 50804 dokumen yang sesuai dengan query
cover
Syifaa Sagakirana
"Latar belakang: Pengembangan material kalsium sulfat yang digabungkan dengan hidroksiapatit, disebut sebagai biphasic hidroksiapatit/kalsium sulfat (biphasic HA/CS), bertujuan untuk dapat menurunkan kelarutan kalsium sulfat. Salah satu pembuatan blok biphasic HA/CS telah berhasil dilakukan melalui metode disolusi presipitasi. Namun, besarnya kelarutan blok biphasic HA/CS tersebut belum diketahui. Tujuan: Penelitian ini bertujuan untuk menguji kelarutan blok biphasic HA/CS pada larutan penyangga 0,05 mol/L Tris-HCl. Metode: Penelitian ini menggunakan tiga kelompok spesimen blok biphasic HA/CS dengan jumlah komposisi HA dan CS yang berbeda, serta satu kelompok spesimen blok kalsium sulfat (blok CS) sebagai kelompok kontrol. Keempat kelompok spesimen tersebut kemudian direndam dalam larutan penyangga Tris-HCl pH 7,4 dan disimpan dalam inkubator dengan suhu 370C selama 7 hari. Setelah 7 hari, spesimen dikeluarkan dari larutan penyangga Tris-HCl dan konsentrasi ion kalsium spesimen yang terlarut dalam larutan penyangga Tris-HCl diukur menggunakan atomic absorption spectroscopy (AAS). Analisis data dilakukan dengan uji statistik One-Way ANOVA. Hasil: Rerata konsentrasi ion kalsium terlarut antara kelompok blok biphasic HA/CS dengan blok CS menunjukkan perbedaan bermakna secara statistik (p<0,05). Rerata konsentrasi ion kalsium kelompok blok CS yang terlarut pada larutan penyangga Tris-HCl, yaitu 206,15 mg/L. Sedangkan, rerata konsentrasi ion kalsium kelompok blok biphasic HA/CS yang terlarut untuk komposisi HA/CS 1 (25,5% HA, 73,9% CS), HA/CS 2 (46,7% HA, 52,4% CS), dan HA/CS 3 (78,1% HA, 20,8% CS), yaitu 121,08; 106,99; dan 94,7 mg/L. Kesimpulan: Blok biphasic HA/CS memiliki kelarutan yang lebih kecil dibanding blok CS. Selain itu, semakin besar komposisi HA pada blok biphasic HA/CS, semakin kecil kelarutan blok biphasic tersebut. Nilai kelarutan terkecil hingga terbesar dari blok biphasic HA/CS secara berurut, yaitu kelompok HA/CS 3, HA/CS 2, dan HA/CS 1.

Background: The development of calcium sulfate material combined with hydroxyapatite, called biphasic hydroxyapatite/calcium sulfate (biphasic HA/CS), aimed to reduce the solubility of the calcium sulfate. The fabrication of biphasic HA/CS block has been successfully carried out through the dissolution-precipitation method. However, the solubility of the biphasic HA/CS block is not yet known. Objective: This study aimed to test the solubility of the biphasic HA/CS block in 0.05 mol/L Tris-HCl buffer solution. Methods: This study used three groups of biphasic HA/CS block with different amounts of HA and CS composition, and one group of calcium sulfate block (CS block) as a control group. The all four groups were then immersed in a Tris-HCl buffer solution with pH 7.4 and stored in an incubator at a temperature of 370C for 7 days. After 7 days, the specimens were removed from the Tris-HCl buffer solution, and the calcium ion concentration of the specimen dissolves in the Tris-HCl buffer solution was measured using atomic absorption spectroscopy (AAS). Data analysis was performed using One-Way ANOVA statistical test. Results: The mean concentration of dissolved calcium ion between the biphasic HA/CS block with CS block group showed a statistically significant difference (p<0.05). The mean concentration of calcium ion in the CS block group dissolves in the Tris-HCl buffer solution was 206.15 mg/L. Meanwhile, the mean concentration of dissolved calcium ion in the biphasic HA/CS block group, HA/CS 1 (25.5% HA, 73.9% CS), HA/CS 2 (46.7% HA, 52.4% CS), and HA/CS 3 (78.1% HA, 20.8% CS), were 121.08, 106.99, and 94.7 mg/L. Conclusions: The biphasic HA/CS block has smaller solubility than the CS block. In addition, the greater the HA composition in the biphasic HA/CS block, the smaller the solubility of the biphasic block. The smallest to the greatest solubility value of biphasic HA/CS blocks respectively are HA/CS 3, HA/CS 2, and HA/CS 1 groups."
Lengkap +
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rheta Indra
"Latar Belakang: Kalsium sulfat merupakan salah satu material alloplast yang banyak digunakan untuk bone graft. Namun, memiliki memiliki tingkat resorpsi yang cepat. Salah satu pengembangan kalsium sulfat yaitu blok biphasicHA/CS yang telah berhasil dilakukan melalui metode disolusi presipitasi dengan tujuan untuk memperlambat resorpsi dari kalsium sulfat. Kelarutan blok biphasic HA/CS tersebut belum diketahui besar kelarutannya. Tujuan: Penelitian ini bertujuan untuk mengetahui kelarutan blok biphasic HA/CS pada larutan penyangga asam asetat 0,08 mol/L selama 7 hari. Metode Penelitian: Blok biphasic HA/CS sebanyak sembilan blok dibagi menjadi tiga kelompok dengan setiap kelompok memiliki komposisi hidroksiapatit dan kalsium sulfat yang berbeda-beda dan blok kalsium sulfat sebanyak tiga blok pada satu kelompok. Setiap kelompok direndam dalam larutan penyangga asam asetat 0,08 Mol/L dengan suhu 37°C selama 7 hari. Setelah 7 hari, kelarutan diukur dengan atomic absorption spectroscopy (AAS). Hasil: Kelarutan berdasarkan hasil uji AAS pada blok biphasic HA/CS mengalami penurunan dibandingkan blok kalsium sulfat. Kelarutan pada blok biphasic HA/CS dengan komposisi 73,9% CS & 25,5% HA, 52,4% CS & 46,7% HA, 20,8% CS & 78,1% HA berturut-turut yaitu 46,44 mg/L; 40,53 mg/L dan 24,28 mg/L. Sedangkan kelarutan blok kalsium sulfat yaitu 59,7 mg/L. Kesimpulan: Blok biphasic HA/CS mengalami penurunan kelarutan dibandingkan blok kalsium sulfat dan semakin banyak komposisi hidroksiapatit pada blok biphasic HA/CS, maka kelarutannya akan semakin menurun.

Background: Calcium sulfate is one of the most widely used alloplast materials for bone graft. However, it has a fast resorption rate. One of the developments of calcium sulfate is the biphasic HA/CS block which has been successfully carried out through the precipitation dissolution method with the aim of slowing the resorption of calcium sulfate. The solubility of the biphasic HA/CS block is not yet known. Objective: This study aimed to determine the solubility of biphasic HA/CS block in 0.08 mol/L acetic acid buffer solution for 7 days. Research Methods: Nine biphasic HA/CS blocks were divided into three groups with each group having different hydroxyapatite and calcium sulfate compositions and three calcium sulfate blocks in one group. Each group was immersed in 0.08 Mol/L acetic acid buffer solution at 37°C for 7 days. After 7 days, the solubility was measured by atomic absorption spectroscopy (AAS). Results: The solubility based on the results of the AAS test on the biphasic HA/CS block decreased compared to the calcium sulfate block. Solubility in the biphasic HA/CS block with the composition of 73.9% CS & 25.5% HA, 52.4% CS & 46.7% HA, 20.8% CS & 78.1% HA, respectively, namely 46, 44 mg/L; 40.53 mg/L and 24.28 mg/L. While the solubility of calcium sulfate block is 59.7 mg/L. Conclusion: The biphasic HA/CS block has decreased solubility compared to the calcium sulfate block and the more hydroxyapatite composition in the biphasic HA/CS block, the lower the solubility.
"
Lengkap +
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Stella Sandra Aurelia
"Hidroksiapatit merupakan salah satu material yang dapat digunakan sebagai bahan bone graft. Adanya pori pada hidroksiapatit dapat membantu mempercepat pertumbuhan tulang. Pembuatan hidroksiapatit berpori yang dilakukan dengan cara sintering menghasilkan derajat kristalinitas yang tinggi. Untuk menghasilkan hidroksiapatit dengan derajat kristalinitas yang rendah dapat menggunakan metode disolusi presipitasi. Penelitian ini bertujuan untuk menghasilkan hidroksiapatit berpori dengan menggunakan kalsium sulfat hemihidrat sebagai prekursor dan PMMA sebagai porogen yang direndam ke dalam 0,5 mol/L larutan Na3PO4 selama 48 jam pada suhu 600C, 800C, dan 1000C. Spesimen dibuat dengan mencampurkan kalsium sulfat hemihidrat dengan bubuk polymethylmethacrylate (rasio berat kalsium sulfat hemihidrat : PMMA adalah 2 : 1). Setelah itu, bubuk dimasukan ke dalam air (rasio w/p 0,5)
dan diaduk hingga rata lalu dimasukkan ke dalam mold dengan tinggi 3 mm dan diameter 6 mm. Setelah itu, spesimen dibakar pada suhu 8000C selama 4 jam untuk menghilangkan porogen. Spesimen yang sudah dibakar direndam ke dalam 0,5 mol/L larutan Na3PO4 pada
suhu 600C, 800C, dan 1000C selama 48 jam masing-masing kelompok 11 spesimen. Uji pola difraksi sinar-X menggunakan PANalytical Xpert PRO (Malvern, UK) dilakukan pada 1 spesimen setiap kelompok dan uji kekuatan tarik diametral menggunakan Universal Testing Machine AGS-X (Shimadzu, Japan) pada 10 spesimen setiap kelompok. Hasil karakterisasi pola difraksi sinar-X pada setiap kelompok perlakuan menunjukkan fasa CaSO4 masih dominan dan fasa hidroksiapatit yang terbentuk masih sedikit. Setiap kelompok perlakuan menghasilkan persentase fasa yang berbeda-beda. Pada kelompok perendaman 1000C ditemukan fasa Ca(OH)2. Nilai kekuatan tarik diametral diuji statistik menggunakan One-Way ANOVA dan post-hoc Bonferonni. Dari hasil uji statistik, tidak ditemukan adanya perbedaan bermakna sebelum perendaman dan setelah perendaman. Pada kelompok perendaman 600C dan 1000C terdapat perbedaan bermakna. Hidroksiapatit berpori tidak sepenuhnya terbentuk pada perendaman kalsium sulfat anhidrat berpori dalam larutan 0,5 mol/L Na3PO4 pada suhu 600C, 800C, ataupun 1000C selama 48 jam."
Lengkap +
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ferdian Yudha Ranadya
"Penelitian ini bertujuan untuk melakukan evaluasi karakteristik pada Thermoluminescence Dosimeter berbahan CaSO4 yang diberikan pendadah fosfor dan berbahan LiF. TLD LiF merupakan dosimeter komersial yang hingga saat ini seringkali digunakan dalam aplikasi klinis seperti radiografi, radioterapi, cath lab, dll. Penggunaan TLD berbahan LiF ini didasarkan karena sifatnya yang mampu menyerap radiasi yang diterima dengan baik karena nilai Atomic Number yang mendekati jaringan manusia. Namun, TLD LiF ini memiliki metode sintesis yang tergolong sulit dan harganya yang cukup mahal, sehingga penelitian ini bertujuan untuk meninjau TLD berbahan lain yakni CaSO4 yang diberi pendadah fosfor untuk melihat sifat dan responnya dalam menyerap radiasi terutama pada energi rendah 50 kVp, 60 kVp, 70 kVp, 80 kVp, 90 kVp dengan mAs yang dijaga konstan sebesar 10 mAs, dan modalitas mamografi 100 mAs, 160 mAs, 200 mAs, dan 250 mAs dengan kVp yang dijaga konstan sebesar 30 kVp. TLD CaSO4:P disintesis menggunakan metode ko-presipitasi kimia dan diuji karakteristiknya menggunakan X-Ray Fluorescence (XRF), X-Ray Diffraction (XRD), dan Scanning Electron Microscope (SEM). Dari penelitian ini, TLD CaSO4:P memiliki karakteristik yang mirip sebagaimana TLD LiF dalam menyerap radiasi, meskipun sensitivitasnya tidak jauh lebih baik namun TLD CaSO4:P memiliki potensi untuk menjadi alternatif dalam penggunaan TLD kedepannya dikarenakan metode sintesisnya yang tergolong mudah dan biaya pembuatannya yang jauh lebih murah.

This research aims to evaluate the characteristics of Thermoluminescence Dosimeters (TLD) of CaSO4 with phosphor dopant and LiF. LiF TLD is a commercial dosimeter that is frequently used in clinical applications such as radiography, radiotherapy, cath lab, etc. The use of LiF-based TLD is based on its ability to efficiently absorb and store received radiation due to its Atomic Number value close to human tissue. However, LiF TLD has a relatively difficult synthesis method and is quite expensive. Therefore, this research aims to explore another TLD material, CaSO4 doped with phosphor, to examine its properties and response in absorbing radiation, especially at low energies of 50 kVp, 60 kVp, 70 kVp, 80 kVp, 90 kVp with constant 10 mAs, and mammography modality at 100 mAs, 160 mAs, 200 mAs, and 250 mAs with constant 30 kVp. CaSO4:P TLD were synthesized using a chemical co-precipitation method and their characteristics were tested using X-Ray Fluorescence (XRF), X-Ray Diffraction (XRD), and Scanning Electron Microscope (SEM). From this research, CaSO4:P TLD exhibit similar characteristics to LiF TLD in terms of absorbing radiation. Although their sensitivity is not significantly better, CaSO4:P TLDs have the potential to become an alternative for future TLD applications due to their relatively easy synthesis method and lower production cost."
Lengkap +
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fatimah Azzahrah Hanifah
"Dosimeter termoluminesensi (TLD) merupakan dosimetri relatif berupa padatan berbahan fosfor yang digunakan untuk mengukur dosis. TLD telah banyak digunakan dalam aplikasi medis baik radiodiagnostik, radioterapi, dan kedokteran nuklir. TLD berbahan fosfor kalsium sulfat (CaSO4) memiliki sifat termoluminesensi dengan sensitivitas tinggi dan pemudaran TL yang rendah. Pendadah P banyak ditambahkan sebagai kodoping pada TLD CaSO4:Dy dan dilaporkan dapat meningkatkan sensitivitas TL tanpa terjadi pergeseran suhu puncak pada TLD. Penelitian ini bertujuan untuk mempelajari sifat termoluminesensi dari penambahan pendadah P (fosforus) pada TLD CaSO4:P hasil sintesis dengan variasi pendadah P yaitu 0,1; 0,5; 1; dan 1,5 mol%. Hasil karakterisasi XRD menunjukkan bahwa CaSO4:P memiliki bentuk kristal ortorombik dan memiliki kemiripan dengan CaSO4 anhidrat (COD 96-500-0041). Selain itu, ukuran rata-rata kristal (D) juga cenderung mengecil seiring bertambahnya konsentrasi pendadah P. Berdasarkan hasil karakterisasi XRF menunjukkan bahwa penambahan pendadah P akan mengalami saturasi pada 0,1 molar. Sementara, hasil karakterisasi SEM menunjukkan bahwa penambahan pendadah P pada kristal CaSO4 menyebabkan perubahan pada morfologi kristal CaSO4 dan menghasilkan ukuran partikel yang semakin mengecil seiring bertambahnya konsentrasi pendadah P. Hasil uji respon TLD CaSO4:P hasil sintesis menunjukkan sensitivitas yang paling baik pada konsentrasi pendadah P 0,1 mol% dengan hasil respon bacaannya sebesar 22,34 ± 11,99 nC, 51,26 ± 24,01 nC, 53,05 ± 10,45 nC dan 63,56 ± 13,23 nC untuk energi 70 kVp, 90 kVp, 6 MV, dan 10 MV. Penambahan pendadah P di atas 0,1 mol% menghasilkan perangkap elektron yang terlalu banyak sehingga elektron sulit tereksitasi dari pita valensi ke pita konduksi dan menyebabkan banyak perangkap elektron yang kosong. TLD CaSO4:P hasil sintesis memiliki respon yang meningkat hingga energi 10 MV dengan suhu puncak kurva pancar di atas 300°C. Berdasarkan perbandingan hasil respon bacaan antara TLD CaSO4:P hasil sintesis dan TLD komersil LiF:Mg,Ti menunjukkan hasil yang cukup sensitif pada energi rendah dengan sensitivitas maksimum pada energi 90 kVp dan perbandingan hasil respon bacaan yang didapatkan yaitu 51,26 ± 24,01 nC untuk TLD CaSO4:P hasil sintesis serta 76,50 ± 26,04 untuk TLD komersil LiF:Mg,Ti.

Thermoluminescence dosimeter (TLD) is a relative dosimetry device made of solid phosphor material used to measure radiation dose. TLD has been widely used in medical applications, including radiodiagnostics, radiotherapy, and nuclear medicine. TLD based on phosphor calcium sulfate (CaSO4) exhibits thermoluminescent properties with high sensitivity and low TL fading. Phosphorus (P) dopant is often added as a co-dopant in TLD CaSO4:Dy and reported to enhance TL sensitivity without shifting the TL peak temperature. This study aims to investigate the thermoluminescent properties of TLD CaSO4:P synthesized with varying concentrations of P dopant, namely 0.1; 0.5; 1; and 1.5 mol%. XRD characterization results show that CaSO4:P has an orthorhombic crystal structure and is similar to anhydrous CaSO4 (COD 96-500-0041). Additionally, the average crystal size (D) tends to decrease with increasing P dopant concentration. Based on XRF characterization, the addition of P dopant reaches saturation at a concentration of 0.1 mol%. SEM characterization results show that the addition of P dopant to CaSO4 crystals alters the crystal morphology and leads to smaller particle sizes with increasing P dopant concentration. The synthesized TLD CaSO4:P shows the best sensitivity at a P dopant concentration of 0.1 mol%, with response readings of 22.34 ± 11.99 nC, 51.26 ± 24.01 nC, 53.05 ± 10.45 nC, and 63.56 ± 13.23 nC for energies of 70 kVp, 90 kVp, 6 MV, and 10 MV, respectively. Adding P dopant above 0.1 mol% results in an excessive number of electron traps, making it difficult for electrons to be excited from the valence band to the conduction band and causing many empty electron traps. The synthesized TLD CaSO4:P exhibits an increased response up to 10 MV energy with the peak temperature of the glow curve above 300°C. By comparing the response readings between synthesized TLD CaSO4:P and commercial TLD LiF:Mg,Ti, a sufficiently high sensitivity is observed at low energies, with the maximum sensitivity occurring at 90 kVp energy. The obtained response readings are 51.26 ± 24.01 nC for synthesized TLD CaSO4:P and 76.50 ± 26.04 nC for commercial TLD LiF:Mg,Ti."
Lengkap +
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Tazkia Qolbina Azzami
"Latar Belakang: Pada penelitian sebelumnya, Hidroksiapatit (HA) berhasil dibuat menggunakan Metode Disolusi Presipitasi dan menghasilkan Prototipe HA yang diprediksi lebih cepat teresorpsi daripada HA yang dibuat dengan Metode Sintering. Akan tetapi, dalam penelitian tersebut belum dikatahui kemampuan resopsinya. Kemampuan resorpsi material berhubungan dengan sifat kelarutannya, oleh karena itu, untuk mengetahui kemampuan resorpsi Prototipe HA dilakukan Uji Kelarutan pada Prototipe HA yang dibandingkan dengan kelarutan HA tersinter (GranuMaSTM). Tujuan: Mengetahui kelarutan Prototipe Hidroksiapatit [Ca10(PO4)6OH2] dari blok CaSO4.2H2O yang dibuat oleh peneliti sebelumnya dengan Metode Disolusi Presipitasi dalam kondisi hidrotermal. Metode Penelitian: Penelitian ini dilakukan dengan merendam Prototipe HA dan GranuMaSTM dalam Larutan Buffer Asetat 0,08 mol/L dan Larutan Buffer TRIS-HCl 0,05 mol/L selama 7 hari dalam suhu 370C. Larutan tersebut kemudian difiltrasi dan dilakukan uji kelarutan menggunakan atomic absorption spectrometry. Data yang diperoleh dianalisis menggunakan Uji T Test Independen untuk mengetahui apakah terdapat perbedaan bermakna antar kelompok. Hasil: Uji statistik menunjukkan perbedaan konsentrasi kalsium yang signifikan antara kedua kelompok pada masing-masing larutan. Pada Larutan Buffer Asetat didapatkan konsentrasi kalsium dengan rata-rata 74,37 mg/L pada larutan yang merendam Prototipe HA dan 62,52 mg/L pada larutan yang merendam GranuMaSTM, sedangkan pada Larutan Buffer TRIS-HCl didapatkan konsentrasi kalsium dengan rata-rata 2,89 mg/L pada larutan yang merendam Prototipe HA dan 3,95 mg/L pada larutan yang merendam GranuMaSTM. Kesimpulan: Pada Larutan Buffer Asetat, kelarutan Prototipe HA lebih besar daripada kelarutan yang terjadi pada GranuMaSTM. Hal tersebut menunjukkan bahwa Prototipe HA diprediksi akan lebih cepat teresorpsi daripada GranuMaSTM ketika terjadi pembentukan tulang. Pada Larutan Buffer TRIS-HCl, kelarutan Prototipe HA lebih kecil daripada kelarutan yang terjadi pada GranuMaSTM. Hal tersebut menunjukkan bahwa Prototipe HA diprediksi akan lebih lambat terlarut daripada GranuMaSTM ketika berinteraksi dengan cairan tubuh sebelum pembentukan tulang baru.

Background: In a previous study, Hydroxyapatite (HA) was successfully prepared using the Precipitation Dissolution Method and produced a prototype HA which was predicted to have a faster resorption than HA made by the Sintering Method. However, in that study, its resorption ability was not known. The resorption ability of the material is related to its solubility properties, therefore, to determine the resorption ability of the HA Prototype, a Solubility Test was carried out on the HA Prototype which was compared with the solubility of sintered HA (GranuMaSTM). Objective: To determine the solubility of the Hydroxyapatite [Ca10(PO4)6OH2] prototype from the CaSO4.2H2O block made by previous researchers using the Precipitation Dissolution Method under hydrothermal conditions. Methods: This research was conducted by immersing the HA and GranuMaSTM Prototypes in 0.08 mol/L Acetate Buffer Solution and 0.05 mol/L TRIS- HCl Buffer Solution for 7 days at 37°C. The solution was filtered, then the solubility test was carried out using atomic absorption spectrometry. The data obtained were analyzed using the Independent T Test to determine whether there were significant differences between groups. Results: Statistical tests showed a significant difference in calcium concentration between the two groups in each solution. In the Acetate Buffer Solution, the average calcium concentration was 74.37 mg/L in the solution that soaked the HA Prototype and 62.52 mg/L in the solution that soaked the GranuMaSTM, while in the TRIS-HCl Buffer Solution, the calcium concentration was obtained with an average 2.89 mg/L in the solution that soaked the HA Prototype and 3.95 mg/L in the solution that soaked the GranuMaSTM. Conclusion: In the Acetate Buffer Solution, the solubility of the HA Prototype is greater than the solubility that occurs in GranuMaSTM. This indicates that the HA prototype is predicted to be absorbed more rapidly than GranuMaSTM when bone formation occurs. In TRIS-HCl Buffer Solution, the solubility of Prototype HA is smaller than the solubility in GranuMaSTM. This suggests that the HA prototype is predicted to be absorbed more slowly than GranuMaSTM when interacting with body fluids prior to new bone formation."
Lengkap +
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Vallen Damayanti
"Blok hidroksiapatit yang dibuat melalui metode sintering sulit teresorpsi di dalam tubuh karena memiliki kristalinitas yang tinggi. Blok hidroksiapatit dengan kristalinitas rendah dapat dibuat melalui reaksi disolusi presipitasi. Kalsium sulfat dihidrat memenuhi persyaratan sebagai prekursor reaksi disolusi presipitasi, yaitu biokompatibel dan secara termodinamik lebih stabil dibandingkan dengan hidroksiapatit. Penelitian ini bertujuan menghasilkan blok hidroksiapatit menggunakan prekursor blok CaSO4.2H2O dengan metode disolusi presipitasi. Spesimen dibuat dengan mencampurkan bubuk CaSO4.1/2H2O dan akuades dengan rasio akuades banding bubuk 0,5. Blok CaSO4.2H2O direndam di dalam larutan Na3PO4 0,5 mol/L dan dipanaskan pada suhu 80˚C selama 24 jam, 48 jam, dan 72 jam. Karakterisasi blok hidroksiapatit dilakukan dengan uji X-ray Diffraction (XRD), kemudian data yang didapatkan dianalisis menggunakan Rietveld Refinement (High Score Plus, PANalytical). Uji kekuatan tarik diametral (DTS) dilakukan untuk mengevaluasi kekuatan mekanik spesimen. Tidak terdapat fasa hidroksiapatit yang teridentifikasi pada seluruh kelompok spesimen. Fasa yang teridentifikasi pada kelompok yang direndam selama 24 jam adalah CaSO4.2H2O, CaSO4, dan Ca(OH)2. Sedangkan pada kelompok yang direndam selama 48 jam dan 72 jam, fasa yang teridentifikasi adalah CaSO4 dan Ca(OH)2. Berdasarkan uji statistik One-Way ANOVA dan Post-Hoc Tamhane (IBM SPSS 2.0), terdapat penurunan nilai DTS yang signifikan pada kelompok sebelum dan sesudah perendaman selama 24 jam, 48 jam, dan 72 jam. Penurunan nilai DTS juga signifikan antara kelompok yang direndam selama 24 jam dengan kelompok yang direndam selama 48 jam dan 72 jam. Namun, tidak terdapat perbedaan bermakna antara nilai DTS kelompok 48 jam dan 72 jam. Disimpulkan bahwa hidroksiapatit tidak terdeteksi pada kelompok spesimen CaSO4.2H2O yang direndam dalam larutan Na3PO4 0,5 mol/L selama 24 jam, 48 jam, dan 72 jam.

Sintered hydroxyapatite cannot be resorbed in the body due to its high crystallinity. Low crystalline hydroxyapatite can be fabricated through dissolution-precipitation reaction. Calcium sulfate dihydrate meets the requirements to be used as a precursor for dissolution-precipitation reaction, that is biocompatible and thermodynamically more stable than hydroxyapatite. The aim of this study was to produce hydroxyapatite block using CaSO4.2H2O based on dissolution precipitation method. Specimens were made from CaSO4.1/2H2O powder mixed with distilled water at a water-to-powder ratio of 0,5. The CaSO4.2H2O blocks were immersed in Na3PO4 0,5 mol/L solution at 80˚C for 24, 48, and 72 hours each. For characterization of the specimens, X-ray Diffraction (XRD) analysis was used and data obtained from the test was analyzed with Rietveld Refinement (High Score Plus, PANalytical). Diametral tensile strength (DTS) was used for mechanical strength evaluation. There was no hydroxyapatite phase identified in all groups of specimens. The phases identified in group with 24 hours immersion time were CaSO4.2H2O, CaSO4, and Ca(OH)2. Whereas in group with 48 and 72 hours immersion time, the phases identified were CaSO4, and Ca(OH)2. Based on statistical analysis using One Way Anova and Post-Hoc Tamhane tests (IBM SPSS 2.0), there was a significant decrease in DTS value between group of specimens before and after immersion for 24, 48, and 72 hours. The decrease in DTS value was also significant between group of specimens with 24 hours immersion time and groups of specimens with 48 hours and 72 hours immersion time. But, the difference between group of specimens with 48 hours and 72 hours immersion time was not significant. It was concluded that there was no hydroxyapatite phase identified in groups of specimens immersed in Na3PO4 0,5 mol/L solution at 80˚C for 24, 48, and 72 hours."
Lengkap +
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhamad Sontang
"ABSTRAK
Telah dilakukan penelitian hydroxyapatite dalam tulang sapi yang dapat diaplikasikan sebagai pengganti tulang manusia. Hydroxyapatite merupakan. kristal dari kelompok mineral apatite dengan rumus molekul Ca10 (PO4)8(OH)2. Penelitian ini bertujuan untuk mengoptimasikan hydroxyapatite dalam tulang sapi melalui proses sintering dalam kondisi hampa udara (vacum). Untuk menentukan perkiraan suhu sintering diakukan penentuan suhu titik lebur tulang sapi dengan menggunakan alat Differential Thermal Analysis (DTA). Hasil yang diperoleh adalah 1227 °C. Proses sintering dilakukan melaluialat Boehler Furnace Automatic Digital dengan pompa vacum yang bertekanan P=103 Torr. Dilakukan pengujien pada soli 500, 600, 700, 800, den 900 selama 2 jam dan pengujian dilarutkan pada suhu 1000, 1100, 1200, 1300, 1400 0C selama 2, 3 and 4 jam. Indicator parameter pengujian dilakukan dengan cara analisa komposisi kilmia, struktur kristal dengan penghalusan data, struktur mikro, dan radikal bebas. Analisa pengujian komposisi kimia secara kualitatif pada permukaan tulang sapi dilakukan dengan alat Energy Diffraction Analysis X-ray (EDAX).
Hasil yang diperoleh adalah terdapat unsur penyusun utama Ca, P, 0, H and Na/lMg (zat an-organik). Pengujian standar mikro permukaan dilakukan dengan Scanning Electron Microscope (SEM) tulang sapi dengan ditemukannya lobang pori-port yang tersebar secara acak dan merata di setiap permukaan. Selanjutnya untuk melihat tingkat kemurnian hydroxyapatite tulang sapi bila dibandingkan dengan standar hydroxyapatite murni melalui parameter pengujian dan dianalisa dari struktur kristalnya secara kuantitatif dengan melihat profil pola dilfraksi sinar - x (X-Ray Diffraction) melalui acuan secara manual (File Data Hanawalt). Selanjutnya data struktur kristalografil hydroxyapatite tulang sapi yang terbaik yaitu pada suhu 1000 °C dengan lama sintering 3 jam dan dihaluskan dengan Rietan. Diperoleh parameter kisi a = 9,435 A° , c = 6,895 A°, volume unit cell (V = 531,605 A3), d = 1,2459, Density (D = 3, 131 gr/cm3). Untuk melihat perkembangan Jumlah radikal bebas dilakukan pengukuran dan pengujian dengan menggunakan sampel yang diradiasi dengan Basis 25 kGy, dan laju dosis 7,5 kGy/h Pengukuran dan pengujian rnenggunakan alat Electron Spin Resonance (ESR). Hasllnya menunjukkan bahwa terdapat pola profil yang spesifik yang sesuai dengan standard hydroxyapatite. Hal ini menunjukkan bahwa pada tulang sapi terdapat dua fase komponen penyusun zat an-organik (radical bebas yang berumur pendek dan berumur panjang). Radikal bebas yang berumur pendek (short life radical) dengan waktu penyimpanan antara (0-60 hari), terdapat pada bagian sisa mineral apatite (residual ash). Sedangkan radikal bebas yang berumur panjang (long life radical) dengan waktu penyimpanan (60-75 hari) terdapat pada bagilan hydroxyapatite. Dengan demikian diharapkan upaya mengoptimasikan hydroxyapatite yang terdapat dalam tulang sapi secara optimal baik kuantitas maupun kualitas produksinya dapat tercapai,melalui proses sintering pada suhu 1000 °C selama 3 jam.

ABSTRACT
It has researched the bovine bone hydroxyapatite that is applied as human bone substitution. Hydroxyapatite is a crystal come from apatite mineral group that's molecul formulated as Cato (POI)s(OH)2. These observance purposes to optimize hydroxyapatite In bovine bone by sintering process In vacuum circumstance. To determine sintering temperature estimation is accomplished with determining melting point temperature of bovine bone by using Differential Thermal Analysis (DTA) device. The obtained result Is 1227 C. Sintering process Is carried out by Boehier Furnace Automatic Digital of vacuum pump P=10-3 Tor- pressurized. The testing was accomplished in temperature for 500, 600,700, 800, 900 gradually taken for 2 hours and for temperature 1000, 1100, 1200, 1300, 1400 °C for 2, 3 and 4 hours. Testing limit Indicator Is accomplished by analyzing chemical composition, crystal structure with smoothing data, micro structure and free radical. Analysis of chemical composition test of bovine bone surface qualitatively is carded out by Energy Diffraction Analysis X-ray (EDAX) device.
The obtained results, there are the main complier element an Inorganic substance. The experiment of surface micro structure Is accomplished by Scanning Electron Microscope (SEM) bovine bone and it got disordered porous and spread out to the standard of pure hydroxyapatite so the trial parameter is analyzed from its crystal structure quantitatively by watching X-ray diffraction patten profil (X-ray Diffraction) throught out the Hint manually (File Data Hanawalt). Than the structure of the best bovine bone hydroxyapatite crystograf reached 1000 °C taken for 3 hours sintering and smoothed by Rietan. Obtained grill parameter a = 9,435 A° , c = 6,895 A°, unit cell volume (V = 531,605 As), d = 1,2459, Density (D = 3, 131 gr/cm3). Watching the growth of the sum of bovine bone free radical with irradiation dose 25 key/rate dose 7,5 kGy/lh. Measuring and testing by using Electron Spin Resonance (ESR) device. Its result shows that the spesific pattern profile those suits with hydroxyapatite standard. It proves that bovine bone has 2 fase components to compile inorganic substance. It has short life radical with 0 - 60 stared day is in the of apatite mineral (residual ash).Otherwise the long life radical with 60-70 stared day is in hydroxyapatite-part. After all, it's expected the effort to optimized hydroxyapatite in the bovine bone for its production both quality and quantity can be reached optimally through out sintering process in temperature 1000 °C for 3 hours.

"
Lengkap +
2000
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Jesslyn Marteen Clarissa
"Latar Belakang: Perbaikan defek tulang dapat dilakukan dengan penggunaan material bone graft. Secara klinis, material bone graft dipakai dalam berbagai variasi ukuran granul yang disesuaikan dengan pertimbangan untuk aplikasi spesifik dan tujuan penggunaan bone graft. Di sisi lain, informasi mengenai pengaruh ukuran granul bone graft belum diketahui dan belum ada penelitian mengenai efek perbedaan ukuran granul pada prototipe karbonat hidroksiapatit terhadap kelarutan in vitro dan sitotoksisitas. Tujuan: Mengevaluasi pengaruh ukuran granul terhadap kelarutan in vitro dan sitotoksisitas prototipe karbonat hidroksiapatit. Metode: Uji kelarutan in vitro dengan merendam prototipe karbonat hidroksiapatit dalam larutan asetat buffer dan Tris-HCl buffer selama 7 hari dalam suhu 37°C. Nilai kelarutan in vitro diuji dengan alat Horiba Ion Selective Electrode. Uji sitotoksisitas dengan MTT Assay pengaruh medium ekstrak terhadap sel preosteoblas MC3T3-E1 selama 1 hari. Nilai absorbansi dibaca dengan ELISA Microplate Reader. Analisis data dengan uji statistik One-Way ANOVA. Hasil: Konsentrasi ion kalsium terlarut dalam larutan asetat buffer pada kelompok ukuran granul 250-500 µm yaitu 45,79 ± 3,11 mg/L, 500-1000 µm yaitu 37,41 ± 4,28 mg/L, dan 1000-2000 µm yaitu 35,85 ± 1,28 mg/L. Konsentrasi ion kalsium terlarut dalam larutan Tris-HCl buffer pada kelompok ukuran granul 250-500 µm yaitu 3,88 ± 0,36 mg/L, 500-1000 µm yaitu 2,94 ± 0,19 mg/L, dan 1000-2000 µm yaitu 2,02 ± 0,58 mg/L. Uji statistik menunjukkan perbedaan konsentrasi ion kalsium terlarut yang signifikan antara granul ukuran 250-500 µm dan 1000-2000 µm pada kedua larutan buffer. Persen viabilitas sel menunjukkan hasil diatas 70% pada semua kelompok ukuran granul dan konsentrasi ekstrak. Uji statistik menunjukkan perbedaan nilai absorbansi dan persen viabilitas sel pada konsentrasi ekstrak 50 mg/mL prototipe karbonat hidroksiapatit ukuran 250-500 µm terhadap 1000-2000 µm, 100 mg/mL prototipe karbonat hidroksiapatit ukuran 250-500 µm terhadap 500-1000 µm, dan konsentrasi ekstrak 200 mg/mL prototipe karbonat hidroksiapatit ukuran 250-500 µm terhadap 1000-2000 µm dan 500-1000 µm terhadap 1000-2000 µm. Kesimpulan: Semakin besar ukuran granul prototipe karbonat hidroksiapatit yang direndam dalam larutan asetat buffer dan Tris-HCl buffer, hasil uji kelarutan in vitro menunjukkan.rata-rata konsentrasi ion kalsium terlarut yang semakin kecil. Uji sitotoksisitas prototipe karbonat hidroksiapatit menunjukkan hasil nontoksik dengan viabilitas sel ukuran granul 1000-2000 µm>500-1000 µm>250-500 µm.

Background: Repair of bone defects can be done using bone graft material. Clinically, bone graft material is used in a variety of granule sizes that are adjusted to consider the specific application and intended use of the bone graft. On the other hand, information regarding the influence of bone graft granule size is not yet known and there has been no research regarding the effect of differences in granule size in hydroxyapatite carbonate prototypes on in vitro solubility and cytotoxicity. Objective: To evaluate the effect of granule size on the in vitro solubility and cytotoxicity of the carbonate hydroxyapatite prototype. Methods: The in vitro solubility test was conducted by immersing the carbonate hydroxyapatite prototype in a solution of acetate buffer and Tris-HCl buffer for 7 days at a temperature of 37°C. The in vitro solubility value was tested using the Horiba Ion Selective Electrode. The cell cytotoxicity test was carried out using MTT assay for the effect of medium extracts on MC3T3-E1 preosteoblast cells. Absorption values were read with an ELISA Microplate Reader. Data analysis using the One-Way ANOVA statistical test. Results: The concentration of dissolved calcium ions in the acetate buffer solution in the granule size group 250-500 µm was 45.79 ± 3.11 mg/L, 500-1000 µm was 37.41 ± 4.28 mg/L, and 1000-2000 µm was 35, 85 ± 1.28mg/L. The concentration of dissolved calcium ions in the Tris-HCl buffer solution in the granule size group 250-500 µm was 3.88 ± 0,36 mg/L, 500-1000 µm was 2.94 ± 0.19 mg/L, and 1000-2000 µm was 2, 02 ± 0.58mg/L. Statistical tests showed significant differences in dissolved calcium ion concentrations between granules measuring 250-500 µm and 1000-2000 µm in both buffer solutions. The percentage of cell viability showed results above 70% in all granule size groups and extract concentrations. Statistical tests show differences in absorption values and percent cell viability at extract concentrations of 50 mg/mL of carbonate hydroxyapatite prototype with a size of 250-500 µm versus 1000-2000 µm, 100 mg/mL hydroxyapatite carbonate prototype with a size of 250-500 µm versus 500-1000 µm, and extract concentration 200 mg/mL carbonate hydroxyapatite prototype size 250-500 µm against 1000-2000 µm and 500-1000 µm against 1000-2000 µm. Conclusion: The larger the size of the carbonate hydroxyapatite prototype granules soaked in acetate buffer and Tris-HCl buffer, the results of the in vitro solubility test show a smaller average concentration of dissolved calcium ions. The cytotoxicity test of the carbonate hydroxyapatite prototype showed nontoxic results with cell viability of granule size 1000-2000 µm > 500-1000 µm > 250-500 µm."
Lengkap +
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Devi Nathania
"[Pemanfaatan radikal sulfat pada proses oksidasi lanjut belum banyak digunakan untukk mendegradasi limbah cair. Pada penelitian ini, akan dilakukan degradasi limbah amonia sintetik dengan proses oksidasi lanjut memanfaatkan radikal sulfat. Radikal sulfat ini disinyalir dapat mendegradasi amonia lebih efisien dibandingkan radikal hidroksil karena bekerja dengan 3 prinsip kerja yakni transfer elektron, pemutusan ikatan rangkap C, dan abstraksi hydrogen. Radikal sulfat didapatkan dari ion persulfat hasil ionisasi K2S2O8 kemudian radikal sulfat diaktifkan dengan menggunakan panas dari heater dengan memvariasikan suhu sebesar 27oC, 50oC dan 70oC. Limbah amonia sintetik dibuat dengan memvariasikan konsentrasi awal amonia sebesar 10 mg/L, 25 mg/L, dan 50 mg/L dan tingkat keasaman (pH) juga divariasikan pada pH 4,7,dan 10 untuk merepresentasikan keadaan asam, netral dan basa limbah amonia sintetik untuk melihat apakah amonia dapat terdegradasi lebih baik dalam bentuk ion atau radikal. Kadar amonia akhir setelah proses oksidasi diukur dengan menggunakan amoniameter dengan prinsip colorimetri. Didapatkan hasil degradasi amonia yang paling baik adalah 22,7% dengan kondisi optimum suhu 50oC, pH 10, dan konsentrasi awal amonia sebesar 10 mg/L., Degradation Technologies using Advanced Oxidation Process with sulfate radical has not been widely developed yet. This research will bring this technology to degrade sintetic amonia waste. Sulfate Radical may reduce ammonia more efficiently than hidroxyl radical mainly with 3 pathways, there are electron transfer, cut of unsaturated bond, and hydrogen abstraction. Sulfate Radical can be got from persulfate ion from Pottasium Persulfate that ionized and activated to be sulfate radical by heat from heater. Temperature of activation becomes one of the research variabel in 27oC, 50oC and 70oC. Initial sintetic ammonia waste is varied from 10 mg/L, 25 mg/L, and 50 mg/L. Acidity is also varied in 4, 7, and 10 that present acid, neutral, and base condition to see whether the amonia will be well degraded as ionic or molecule. The end concentration of ammonia is measured with martini ammoniameter. The best result for this research is 22,7% of ammonia removal in 50oC, pH 10, and the first ammonia concentration of 10 mg/L.]"
Lengkap +
Fakultas Teknik Universitas Indonesia, 2014
S58831
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>