Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3809 dokumen yang sesuai dengan query
cover
cover
cover
cover
Ronnie Higuchi Rusli
"Boron liquid metal ion sources (LMIS) for focused ion beam system have been developed in the form of binary eutectic alloy of Pd73B27. This alloy source was selected as a p-type dopant source. A source life time of more than 120 h has been recorded with different emitter tip radii to test boron ion beam stability. Microstructure examination of the Pd73B27 binary alloy proved that boron LMIS instability was cause primarily by the formation of solid precipitates due to a change in alloy stoichiometry. Auger electron spectroscopy (AES) analysis of boron beam deposited on a flat silicon substrate shows rhenium emitter erosion as well as other elements (Fe, Ni and Cr) resulting from extractor sputtering. Greater attention was paid on the metallurgical aspect of LMIS to develop more reliable boron LMIS.

Sumber ion metal cair boron untuk sistem berkas ion terpusat telah dibuat dengan menggunakan paduan biner "eutectic" Pd73B27- Sumber berkas ion dari paduan ini dipilih sebagai sumber dopan jenis p. Masa pakai paduan lebih dari 120 jam telah dicatat dengan percobaan menggunakan berbagai ukuran jari-jari emiter untuk mengukur kestabilan dari berkas ion yang berbasis boron. Penyelidikan terhadap struktur mikro dari paduan biner Pd73B27 membuktikan bahwa ketidak stabilan dari sumber ion metal cair berbasis boron disebabkan oleh pembentukan presipitat padatan. Pembentukan presipitat padatan ini akibat dari perubahan "stoichiometry". Analisa dengan menggunakan spektroskopi Auger dengan cara mendipositkan berkas ion ini pada permukaan lempeng silikon yang rata membuktikan bahwa terjadi erosi emiter yang terbuat dari rhenium dan juga elemen lain akibat dari pengaruh "sputtering" ekstraktor. Perhatian pada penelitian ini ditujukan pada aspek metalurgi dari sumber berkas ion metal cair untuk mengembangkan sumber ion metal cair boron yang dapat diandalkan."
[place of publication not identified]: Jurnal Ilmu dan Rekayasa Material, 1999
JIRM-1-2-Agust1999-1
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Muhammad Alief Meinanda
"

Teknik Neutron Scattering merupakan salah satu teknik yang berperan sangat penting terhadap perkembangannya teknologi baterai lithium-ion, yang dimana teknik ini digunakan untuk menginvestigasi kemampuan penyimpanan energi pada baterai lithium-ion. Pada prinsipnya neutron scattering memanfaatkan neutron yang mampu mendeteksi unsur-unsur yang sangat ringan dan menjadikan suatu kelebihan yang sangat penting pada teknik.neutron scattering. Mengingat pentingnya material penyimpanan energi seperti lithium-ion yang digunakan pada perangkat elektronik sehari-hari maka semakin besar tuntutan untuk membuat dan menemukan material baterai litihum-ion semakin berkembang pada life time, kemampuan cyclic dan stabilitasnya. Penelitian ini dilakukan untuk mempelajari cara penggunaan dan pemanfaatan teknik neutron beam scattering dalam mengidentifikasi struktur crystal dari sampel yang digunakan yaitu anoda ZnO, dengan menggunakan high resollution power diffraction (HPRD) di Badan Tenaga Nuklir Nasional (BATAN). Hasil yang didapat pada posisi 2 theta pada titik 114,32 derajat didapat grid parameter 2,899 yang dimana apabila dibulatkan sangat mendekati grid parameter unsur besi (Fe) yang bernilai 2,866 Angstorm. Namun belum terlihat unsur lain selain besi dikarenakan besarnya intensitas casing besi dari sample coin cell baterai.

 


Neutron Scattering technique is one technique that plays a very important role in the development of lithium-ion battery technology, which is used to investigate the energy storage capabilities of lithium-ion batteries. In principle, neutron scattering utilizes neutrons which are capable of detecting very light elements and making a very important advantage in techniques. Neutron scattering. Considering the importance of energy storage materials such as lithium-ion used in everyday electronic devices, the greater the demand to make and find battery-litihum-ion materials increasingly develops on life time, cyclic ability and stability. This research was conducted to study how to use and use the neutron scattering technique in identifying the crystal structure of the sample used, namely ZnO anode, using high resistance power diffraction (HPRD) at BadaN National Nuclear Power (BATAN).

 

"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rizky Fitri Lestari
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
TA1343
UI - Tugas Akhir  Universitas Indonesia Library
cover
Innet Maysyarah
"ABSTRAK
Klopidogrel merupakan obat antiplatelet yang konsentrasinya dalam darah sangat kecil karena akan dimetabolisme menjadi metabolit aktif dan inaktifnya setelah pemberian oral. Klopidogrel induk memiliki konsentrasi plasma 2000 kali lebih rendah dari metabolit inaktifnya, yakni klopidogrel karboksilat. Penelitian ini bertujuan untuk memperoleh metode analisis klopidogrel dalam plasma yang sensitif dan selektif serta tervalidasi agar dapat mengukur kadar klopidogrel dalam plasma secara akurat, menggunakan Kromatografi Cair Kinerja Ultra Tinggi - Tandem Spektrometri Massa (KCKUT-SM/SM). Sistem kromatografi terdiri dari kolom Waters Acquity UPLC Class BEH C18 1,7 μm (2,1 x 100 mm), fase gerak berupa asam formiat 0,1% dalam air ? asam formiat 0,1% dalam asetonitril (30:70), dengan elusi isokratik dan laju alir 0,2 mL/menit. Deteksi massa dilakukan dengan Waters Xevo TQD tipe Electrospray Ionization (ESI) positif pada mode Multiple Reaction Monitoring. Klopidogrel dideteksi pada m/z 322,086 > 212,097, dan irbesartan sebagai baku dalam pada m/z 429,233 > 207,131. Preparasi sampel dilakukan dengan metode pengendapan protein menggunakan asetonitril kemudian dikocok dengan vorteks selama 10 menit dan disentrifugasi pada kecepatan 13.000 rpm selama 20 menit. Metode ini linear pada rentang konsentrasi 0,2 -10 ng/mL dengan r > 0,9997. Hasil validasi terhadap metode analisis klopidogrel yang dilakukan memenuhi persyaratan validasi berdasarkan EMEA Bioanalytical Guideline tahun 2011.

ABSTRACT
Clopidogrel is an antiplatelet drug with a very small plasma concentration because of its extensive metabolism into active and inactive metabolites after oral administration. The parent clopidogrel has plasma concentration 2000 times lower than the inactive metabolite, clopidogrel carboxylic. This study was aimed to obtain sensitive, selective and valid method to analyze clopidogrel in plasma, using Ultra Performance Liquid Chromatography tandem Mass Spectrometry (UPLC-MS/MS). Chromatography system used are Waters Acquity UPLC Class BEH C18 1.7 μm ( 2.1 x 100 mm) column and 0.1% formic acid in water ? 0.1% formic acid in acetonitrile (30-70) as mobile phase, under isocratic elution with flow rate 0.2 mL/min. Mass detection was performed with Waters Xevo TQD equipped with positive electrospray ionization (ESI) on multiple reaction monitoring (MRM) mode. Clopidogrel was detected at m/z 322.086 > 212.097, compared to internal standard irbesartan at m/z 429.233 > 207.131. Sample was prepared by protein precipitation method with acetonitrile, mixed with vortex for 10 minutes, and then centrifuged on 13000 rpm for 20 minutes. This method is showing linear result at the concentration range 0.2-10 ng/mL with r > 0.9997. This method meets the 2011 EMEA Bioanalytical Guideline validation requirement."
2016
S64312
UI - Skripsi Membership  Universitas Indonesia Library
cover
Amsterdam : Elsevier, 1989
530.41 ION
Buku Teks SO  Universitas Indonesia Library
cover
Yang V. Li, editor
"Stroke is a major cause of death and disability in the U.S. and worldwide. A variety of pathophysiologic episodes or cellular medications occur following a stroke, and knowledge of these aftermath events can lead to potential therapeutic strategies that may reverse or attenuate stroke injury. Cellular events that occur following stroke include the excessive releases of excitatory amino acids, alterations in the genomic responses, mitochondrial injury producing reactive oxygen and nitrogen species (ROS), and secondary injury, often in the setting of reperfusion."
New York: [, Springer], 2012
e20417622
eBooks  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>