Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 32292 dokumen yang sesuai dengan query
cover
cover
cover
cover
Ronnie Higuchi Rusli
"Boron liquid metal ion sources (LMIS) for focused ion beam system have been developed in the form of binary eutectic alloy of Pd73B27. This alloy source was selected as a p-type dopant source. A source life time of more than 120 h has been recorded with different emitter tip radii to test boron ion beam stability. Microstructure examination of the Pd73B27 binary alloy proved that boron LMIS instability was cause primarily by the formation of solid precipitates due to a change in alloy stoichiometry. Auger electron spectroscopy (AES) analysis of boron beam deposited on a flat silicon substrate shows rhenium emitter erosion as well as other elements (Fe, Ni and Cr) resulting from extractor sputtering. Greater attention was paid on the metallurgical aspect of LMIS to develop more reliable boron LMIS.

Sumber ion metal cair boron untuk sistem berkas ion terpusat telah dibuat dengan menggunakan paduan biner "eutectic" Pd73B27- Sumber berkas ion dari paduan ini dipilih sebagai sumber dopan jenis p. Masa pakai paduan lebih dari 120 jam telah dicatat dengan percobaan menggunakan berbagai ukuran jari-jari emiter untuk mengukur kestabilan dari berkas ion yang berbasis boron. Penyelidikan terhadap struktur mikro dari paduan biner Pd73B27 membuktikan bahwa ketidak stabilan dari sumber ion metal cair berbasis boron disebabkan oleh pembentukan presipitat padatan. Pembentukan presipitat padatan ini akibat dari perubahan "stoichiometry". Analisa dengan menggunakan spektroskopi Auger dengan cara mendipositkan berkas ion ini pada permukaan lempeng silikon yang rata membuktikan bahwa terjadi erosi emiter yang terbuat dari rhenium dan juga elemen lain akibat dari pengaruh "sputtering" ekstraktor. Perhatian pada penelitian ini ditujukan pada aspek metalurgi dari sumber berkas ion metal cair untuk mengembangkan sumber ion metal cair boron yang dapat diandalkan."
[place of publication not identified]: Jurnal Ilmu dan Rekayasa Material, 1999
JIRM-1-2-Agust1999-1
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Muhammad Falahuddin Malich Salaz
"Asam valproat merupakan obat anti epilepsi yang bisa digunakan pada semua tipe epilepsi dan berkembang sebagai terapi tambahan untuk penyakit bipolar Obat ini memiliki indeks terapi sempit sehingga dibutuhkan pemantauan terapi obat menggunakan metode dried blood spot yang sederhana dan mudah dilakukan serta akurat Tujuannya untuk memperoleh kondisi optimum dan metode tervalidasi asam valproat dalam darah total secara Kromatografi Cair Kinerja Ultra Tinggi Tandem Spektrometri Massa KCKUT SM SM Larutan kontrol kualitas dan kurva kalibrasi sampel darah dibuat dengan menotolkan masing masing sebanyak 20 L dan dikeringkan selama lebih kurang 1 jam Kertas DBS dipotong sekitar lebih kurang 5 mm dan diekstraksi menggunakan campuran larutan asetonitril metanol 1 3 yang mengandung baku dalam asam benzoat dengan konsentrasi 1000 g mL Pemisahan dilakukan menggunakan kolom Waters AcquityTM UPLC C18 1 7 m 2 1 x 100 mm dengan fase gerak berupa campuran asam asetat 0 1 asetonitril 40 60 dengan elusi isokratik dan laju alir 0 4 mL menit Deteksi massa dilakukan dengan Waters Xevo TQD tipe Electrospray Ionization ESI negatif pada mode Multiple Reaction Monitoring Pendeteksian asam valproat berada pada nilai m z 142 95 142 95 dan asam benzoat pada m z 121 1 77 1 Metode ini linear pada rentang 0 5 ndash 100 g mL dengan r 0 9991 Akurasi dan presisi baik within run maupun between run memenuhi persyaratan dengan nilai diff dan KV tidak melebihi 15 dan tidak lebih dari 20 pada konsentrasi LLOQ Sampel DBS stabil minimal 16 hari pada suhu kamar Metode analisis tervalidasi diaplikasikan terhadap satu subjek sehat dan diperoleh Cmax sebesar 88 15 g mL dan Tmax 1 5 jam Secara keseluruhan metode ini memenuhi persyaratan validasi menurut EMEA Guideline 2011.
Valproic acid VA is drug of anticonvulsant which used to treat all types of epilepsy and be developed as an adjuvant therapy for bipolar disorder Valproic acid VA has a narrow of therapeutic window index that need therapeutic drug monitoring with dried blood spot method which is simple easy and accurate This aim of this research is to develop an optimum and validated method valproic acid in whole blood as Dried Blood Spot method using Ultra Performance Liquid Chromatography tandem Mass Spectrometry UPLC MS MS Quality control and calibration samples were obtained by pipetting 20 L onto CAMAG DBS Paper and left to dry at room temperature for 1 h before processing Using a 5 mm punch cutter Disc were transferred to microtube and 200 L extraction solution asetonitril metanol 1 3 containing benzoic acid as internal standard 1000 g mL was added Chromatographic separation was achieved by Waters AcquityTM UPLC C18 1 7 m 2 1 x 100 mm with mobile phase consist of 0 1 acetic acid acetonitrile 40 60 under isocratic elution and flow rate was 0 4 mL min Mass detection was performed on Waters Xevo TQD equipped with an electrospray ionization ESI source at negative ion mode in the multiple reaction monitoring MRM mode Valproic acid VA was detected at m z 142 95 142 95 benzoic acid at m z 121 11 77 1 This method was linear in range concentration of 0 5 ndash 100 g mL with r 0 9991 This method also fulfill the acceptance of accuracy and precision within and between run in three days by diff and coefficient of variation CV not more than 15 and not more than 20 for LLOQ concentration The DBS Card samples is stable at least for 16 days at room temperature Validation method was applied in one healthy subject was obtained Cmax 88 15 g mL with Tmax 1 5 h Overall this method fulfill the acceptance criteria of validation based on EMEA Guideline 2011."
Depok: [Fakultas Farmasi Universitas Indonesia;Fakultas Farmasi Universitas Indonesia, Fakultas Farmasi Universitas Indonesia], 2015
S59742
UI - Skripsi Membership  Universitas Indonesia Library
cover
Anisa Maulidina
"ABSTRAK
Klopidogrel merupakan prodrug dengan onset aksi lambat yang konsentrasinya dalam plasma sangat kecil sehingga diperlukan metode analisis yang sensitif dan selektif. Pada analisis dalam plasma in-vivo seringkali digunakan jenis antikoagulan yang berbeda dengan analisis in-vitro. Perbedaan antikoagulan memungkinkan dapat mengganggu analisis sehingga diperlukan suatu evaluasi.
Penelitian ini bertujuan untuk melakukan optimasi dan validasi metode analisis klopidogrel dalam plasma menggunakan kromatografi cair kinerja ultra tinggi tandem spektrometer massa. Kondisi analisis optimal diperoleh menggunakan kolom BEH C18 (1,7 µm; 100 x 2,1 mm); fase gerak asam formiat 0,1% dalam air-asam formiat 0,1% dalam asetonitril (30:70); laju alir 0,2 mL/menit; suhu
kolom 35ºC; volume penyuntikkan 5,0 µL; waktu analisis 4 menit; dan irbesartan sebagai baku dalam. Aliquot diperoleh secara ekstraksi cair-cair menggunakan amonium asetat dan dietil eter. Akurasi dan presisi pada analisis plasma sitrat, heparin, dan EDTA memenuhi persyaratan dan kurva kalibrasi linear pada rentang konsentrasi 0,02-5,0 ng/mL. Stabilitas dan peak area ratio masing-masing plasma
dievaluasi menggunakan ANOVA. Hasil stabilitas menunjukkan tidak terdapat perbedaan signifikan (p>0,05) sedangkan peak area ratio menunjukkan perbedaan signifikan (p<0,05) pada ketiga plasma. Secara keseluruhan, analisis dengan plasma sitrat atau heparin memberikan hasil yang lebih baik dari plasma EDTA.

ABSTRACT
Clopidogrel is a prodrug with a very slow onset and whose concentration in plasma is so small that a sensitive and selective analysis method is required. In the analysis of plasma in-vivo, different types of anticoagulants is often used, for example citrate, heparin, and EDTA. The anticoagulant difference allows it to interfere with the analysis so that an evaluation is needed. This research is aimed to the optimization and validation of clopidogrel analysis method in plasma using ultra-high performance liquid chromatography tandem mass spectrometer. The optimal analysis conditions were obtained using BEH C18 column (1,7 μm; 100 × 2,1 mm); formic acid 0,1% in water-formic acid 0,1% in acetonitrile (30:70); 0.2 mL/min flow rate; 35ºC column temperature; inject volume 5,0 μL; 4 minute of analysis time; and irbesartan as internal standard. Aliquots were obtained by liquid-liquid extraction using ammonium acetate and diethyl ether. The accuracy and precision of the analyisis of citrate, heparin, EDTA plasma met the requirements and linear calibration curve at range concentrations 0,02-5,0 ng/mL.
The stability and peak area ratio of the respective plasma area responses were evaluated using ANOVA. Results on stability showed no significant differences (p>0,05) while peak area ratio showed significant differences (p<0.05). As a whole, analysis using citrate or heparin plasma produce a better result than EDTA plasma."
2017
S69340
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Alief Meinanda
"

Teknik Neutron Scattering merupakan salah satu teknik yang berperan sangat penting terhadap perkembangannya teknologi baterai lithium-ion, yang dimana teknik ini digunakan untuk menginvestigasi kemampuan penyimpanan energi pada baterai lithium-ion. Pada prinsipnya neutron scattering memanfaatkan neutron yang mampu mendeteksi unsur-unsur yang sangat ringan dan menjadikan suatu kelebihan yang sangat penting pada teknik.neutron scattering. Mengingat pentingnya material penyimpanan energi seperti lithium-ion yang digunakan pada perangkat elektronik sehari-hari maka semakin besar tuntutan untuk membuat dan menemukan material baterai litihum-ion semakin berkembang pada life time, kemampuan cyclic dan stabilitasnya. Penelitian ini dilakukan untuk mempelajari cara penggunaan dan pemanfaatan teknik neutron beam scattering dalam mengidentifikasi struktur crystal dari sampel yang digunakan yaitu anoda ZnO, dengan menggunakan high resollution power diffraction (HPRD) di Badan Tenaga Nuklir Nasional (BATAN). Hasil yang didapat pada posisi 2 theta pada titik 114,32 derajat didapat grid parameter 2,899 yang dimana apabila dibulatkan sangat mendekati grid parameter unsur besi (Fe) yang bernilai 2,866 Angstorm. Namun belum terlihat unsur lain selain besi dikarenakan besarnya intensitas casing besi dari sample coin cell baterai.

 


Neutron Scattering technique is one technique that plays a very important role in the development of lithium-ion battery technology, which is used to investigate the energy storage capabilities of lithium-ion batteries. In principle, neutron scattering utilizes neutrons which are capable of detecting very light elements and making a very important advantage in techniques. Neutron scattering. Considering the importance of energy storage materials such as lithium-ion used in everyday electronic devices, the greater the demand to make and find battery-litihum-ion materials increasingly develops on life time, cyclic ability and stability. This research was conducted to study how to use and use the neutron scattering technique in identifying the crystal structure of the sample used, namely ZnO anode, using high resistance power diffraction (HPRD) at BadaN National Nuclear Power (BATAN).

 

"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rizky Fitri Lestari
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
TA1343
UI - Tugas Akhir  Universitas Indonesia Library
cover
Innet Maysyarah
"ABSTRAK
Klopidogrel merupakan obat antiplatelet yang konsentrasinya dalam darah sangat kecil karena akan dimetabolisme menjadi metabolit aktif dan inaktifnya setelah pemberian oral. Klopidogrel induk memiliki konsentrasi plasma 2000 kali lebih rendah dari metabolit inaktifnya, yakni klopidogrel karboksilat. Penelitian ini bertujuan untuk memperoleh metode analisis klopidogrel dalam plasma yang sensitif dan selektif serta tervalidasi agar dapat mengukur kadar klopidogrel dalam plasma secara akurat, menggunakan Kromatografi Cair Kinerja Ultra Tinggi - Tandem Spektrometri Massa (KCKUT-SM/SM). Sistem kromatografi terdiri dari kolom Waters Acquity UPLC Class BEH C18 1,7 μm (2,1 x 100 mm), fase gerak berupa asam formiat 0,1% dalam air ? asam formiat 0,1% dalam asetonitril (30:70), dengan elusi isokratik dan laju alir 0,2 mL/menit. Deteksi massa dilakukan dengan Waters Xevo TQD tipe Electrospray Ionization (ESI) positif pada mode Multiple Reaction Monitoring. Klopidogrel dideteksi pada m/z 322,086 > 212,097, dan irbesartan sebagai baku dalam pada m/z 429,233 > 207,131. Preparasi sampel dilakukan dengan metode pengendapan protein menggunakan asetonitril kemudian dikocok dengan vorteks selama 10 menit dan disentrifugasi pada kecepatan 13.000 rpm selama 20 menit. Metode ini linear pada rentang konsentrasi 0,2 -10 ng/mL dengan r > 0,9997. Hasil validasi terhadap metode analisis klopidogrel yang dilakukan memenuhi persyaratan validasi berdasarkan EMEA Bioanalytical Guideline tahun 2011.

ABSTRACT
Clopidogrel is an antiplatelet drug with a very small plasma concentration because of its extensive metabolism into active and inactive metabolites after oral administration. The parent clopidogrel has plasma concentration 2000 times lower than the inactive metabolite, clopidogrel carboxylic. This study was aimed to obtain sensitive, selective and valid method to analyze clopidogrel in plasma, using Ultra Performance Liquid Chromatography tandem Mass Spectrometry (UPLC-MS/MS). Chromatography system used are Waters Acquity UPLC Class BEH C18 1.7 μm ( 2.1 x 100 mm) column and 0.1% formic acid in water ? 0.1% formic acid in acetonitrile (30-70) as mobile phase, under isocratic elution with flow rate 0.2 mL/min. Mass detection was performed with Waters Xevo TQD equipped with positive electrospray ionization (ESI) on multiple reaction monitoring (MRM) mode. Clopidogrel was detected at m/z 322.086 > 212.097, compared to internal standard irbesartan at m/z 429.233 > 207.131. Sample was prepared by protein precipitation method with acetonitrile, mixed with vortex for 10 minutes, and then centrifuged on 13000 rpm for 20 minutes. This method is showing linear result at the concentration range 0.2-10 ng/mL with r > 0.9997. This method meets the 2011 EMEA Bioanalytical Guideline validation requirement."
2016
S64312
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>