Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 514 dokumen yang sesuai dengan query
cover
Sunarto
"A fluorescence spectrometer, with gating PMT (Photo Multiplier Tube) has been designed and constructed for the observation of Time Resolved Spectroscopy. Employed as a source far the fluorescence spectrometer a pulsed N2 lasers with about 5-nanosecond pulse width and 400-kilowatt power. Gating PMT carries out the sampling. In this method some of the dynodes of the PMT are being biased at voltages below normal operating voltage, while the other dynodes are held at their normal voltages. Sampling pulses generated by avalanche transistor are fed into the dynodes of the lower voltage to operate the PMT. A variable delay circuit of the order of nanosecond with respect to the N2 lasers pulse delays the sampling pulses. The output of the PMT is read on an oscilloscope and the lifetime of the fluorescence can be obtained by plotting the output of the PMT vs. the delay time."
Depok: Fakultas Teknik Universitas Indonesia, 1988
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Yusuf Zaim Hakim
"ABSTRAK
Sintesis ligan turunan pirazol 2-(1,5-difenil-4,5-dihidro-1H-pirazol-3-yl)piridin telah berhasil dilakukan dengan metode kondensasi Claisen-Schmidt diikuti dengan penambahan fenil hidrazin berlebih dalam medium pelarut etanol. Padatan kuning kemerahan dengan yield sebesar 28,85% kemudian dikarakterisasi menggunakan spektrofotometer UV-Vis, FTIR, dan spektrometer H-NMR. Studi spektroskopi UV-Vis dilakukan untuk mengetahui pembentukan kompleks antara logam lantanida dengan ligan dalam pelarut asetonitril. Uji aplikasi fluoresens dengan spektrofluorometer diamati untuk melihat perubahan intensitas emisi pada penambahan logam La3+ dan Eu3+. Hasil studi dengan spektroskopi UV-Visible menunjukkan pembentukan kompleks [EuL2]3+ dengan perbandingan Eu3+ : L (1:2) terjadi pada panjang gelombang 366 nm, sedangkan kompleks [LaL3]3+ dimana perbandingan La3+ : L (1:3) terjadi pada λmax 342 nm. Analisis fluoresensi menunjukkan ligan memiliki λ eksitasi 257 nm dan 365 nm dengan nilai absorptivitas molar yang cukup besar pada konsetrasi 2x10-5 M. Penambahan logam La3+ menghasilkan efek fluorescence enhancement pada panjang gelombang emisi 355 nm. Sedangkan penambahan Eu3+ menunjukkan efek pemadaman intensitas emisi pada panjang gelombang 340 nm. Studi selektivitas ligan terhadap keberadaan ion Eu3+ dan La3+ secara bersamaan menunjukkan ligan merupakan fluoresensor yang selektif terhadap La3+ pada λ eksitasi dan λ emisi 257 nm dan 356 nm serta terhadap Eu3+ pada λ eksitasi 273 nm dan λ emisi 341 nm

ABSTRAK
Synthesis of pyrazole derivative ligand 2- (1,5-diphenyl-4,5-dihydro-1H-pyrazole-3-yl) pyridine has been successfully carried out by the method of Claisen-Schmidt condensation followed by the excess addition of phenyl hydrazine in ethanol solution. Reddish yellow solid with a 28.85% yield then characterized using FTIR , UV-Visible, and H1-NMR spectroscopy. UV-Visible spectroscopy study was conducted to determine the complex formation between lanthanide ions with ligands. Fluorescence application test with spectrofluorometer was observed in ligand emission intensity change upon addition of La3+ and the Eu3+. The study by UV-Visible spectroscopy show complex formation of [EuL2]3+ with the ratio Eu3+ : L (1:2) occurs at a absorption wavelength of 366 nm, while the complex [LaL3]3+ with the ratio La3+ : L (1:2) occurred at 342 nm in acetonitrile solution. Fluorescence analysis showed ligands have two excitation λ at 257 nm 365 nm with a appreciable molar absorptivity in concentration 2x10-5 M. The addition of La3+ metal lead to the fluorescence enhancement effect on the λem at 355 nm. While the addition of the Eu3+ demonstrates the effect of fluorescence quenching at the λem 340 nm. Ligand selectivity studies of the existence of ion Eu3+ and La3+ simultaneously show selective fluorescence against La3+ occurred at λex and λem 257 nm and 356 nm as well as the Eu3+ occurred at 273 nm and 341 nm respectively."
2016
S64244
UI - Skripsi Membership  Universitas Indonesia Library
cover
Girsang, Gery Rafaniel
"Pencitraan fluorescence merupakan salah satu jenis pencitraan yang digunakan oleh tenaga medis dalam mendiagnosa penyakit yang dimiliki pasien. Pencitraan ini juga mampu dilakukan secara intraoperative tanpa harus mengakibatkan efek samping seperti mutasi gen yang disebabkan oleh jenis pencitraan lainnya yang menggunakan radiasi elektromagnetik dan radioaktif (CT, MRI, dan PET). Keterbatasan dana menjadi penyebab tidak semua rumah sakit mampu membeli sistem deteksi pencitraan fluorescence yang mahal. Salah satu komponen penting dalam pencitraan ini adalah filter optik yang mampu memblokade sinar eksitasi dan membiarkan sinar emisi untuk dideteksi oleh kamera. Penelitian ini dimaksudkan untuk merancang filter optik sinar fluorescence dengan menggunakan bahan dasar plastik mika yang didapat secara komersil. Perancangan filter menggunakan kombinasi plastik mika dan foto film serta kamera CCTV berbasis IP yang telah dimodifikasi untuk mampu mendeteksi sinar fluorescence pada area sinar infra merah. Pengujian dilakukan pada ruang yang gelap dengan objek yang diuji adalah campuran Indocyanine Green (ICG) yang dicampurkan dengan air steril. Perancangan filter menggunakan spektrofotometer sehingga menghasilkan kombinasi filter abu abu gelap-foto film yang memiliki rasio gain sebesar 2,56. Pada saat pengujian, filter mampu meningkatkan sinyal cahaya fluorescence (S/B) dari 0,675 menjadi 1,502 akibat adanya peredaman sinar eksitasi pada bagian latar belakang gambar.

Fluorescence imaging is a type of imaging used by medical professionals when diagnosing disease in patients. This imaging can also be performed intraoperatively without causing side effects such as genetic mutations caused by other types of imaging (CT, MRI, and PET) that use electromagnetic and radioactive radiation. Funding constraints are why not all hospitals can afford expensive fluorescent imaging detection systems. One of the important components of this imaging is the filter, which blocks the excitation beam and allows the camera to detect the emitted light. This study aimed to design fluorescence filters using commercially available mica plastic as the base material. The filter design combines mica paper and film with a modified IP-based CCTV camera capable of detecting fluorescence in the infrared region. The test was carried out in a dark room, and the test object was a mixture of indocyanine green (ICG) and sterile water. The filter design uses a spectrophotometer to produce a dark gray-film filter combination with a gain ratio of 2.56. When tested, the filter was able to increase the fluorescence (S/B) light signal from 0.675 to 1.502 due to attenuation of the excitation light on the image background."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Parintosa Atmodiwirjo
"Risiko kegagalan dapat terjadi pada rekonstruksi dengan flap bebas karena mengandalkan vaskularisasi kecil. Pemeriksaan klinis yang merupakan baku emas dalam evaluasi sirkulasi flap masih bersifat subjektif dan sulit untuk mendeteksi gangguan vaskularisasi secara dini. Indocyanine green (ICG) merupakan instrumen pemeriksaan objektif yang dapat digunakan untuk evaluasi sirkulasi flap, tetapi belum ada konsensus mengenai dosis ICG dan kekuatan fluoresensi bersifat dose-dependent. Pada penelitian awal model in vitro dan hewan coba didapatkan konsentrasi 0,5 mg/mL menghasilkan fluoresensi yang setara dengan konsentrasi standar (5 mg/mL). Analisis dosis titrasi ICG dilakukan pada penelitian ini untuk mengevaluasi (sirkulasi) flap bebas menggunakan kamera near-infrared radiation standar serta korelasinya terhadap pemeriksaan suhu flap, TcPCO2, TcPO2, kadar HIF-1α, dan gambaran histopatologi flap untuk menunjang bedah mikro rekonstruksi. Penelitian menggunakan desain eksperimental uji klinis acak tersamar ganda di Rumah Sakit Umum Pusat Nasional dr. Cipto Mangunkusumo (RSCM) dan Rumah Sakit Persahabatan (RSP) pada bulan September 2022 hingga Januari 2024. Sebanyak 63 pasien yang sesuai dengan kriteria inklusi dari kuesioner skrining dilakukan randomisasi menjadi 3 kelompok konsentrasi ICG, yaitu 5 mg/mL, 2,5 mg/mL, dan 0,5 mg/mL yang diberikan ICG secara intravena, dengan jumlah masing-masing 21 flap. Data diambil segera pasca-operasi, 24 jam, 72 jam, serta 120 jam pasca-operasi. Ketiga kelompok menunjukkan peningkatan fluoresensi ICG dari waktu ke waktu, dengan intensitas fluoresensi pada konsentrasi 2,5 mg/mL serupa dengan konsentrasi standar (p = 0,792), tetapi intensitas konsentrasi 0,5 mg/mL lebih lemah (p = 0,006 dan p = 0,041). Intensitas fluoresensi tidak berkorelasi dengan pemeriksaan objektif lainnya. Disimpulkan besar dosis ICG memengaruhi intensitas fluoresensi karena fenomena quenching effect dan keseimbangan ikatan ICG dengan protein plasma. Analisis konsentrasi 5 mg/mL dan 2,5 mg/mL menghasilkan intensitas serupa sehingga penggunaan dosis 2,5 mg/mL dapat menggantikan dosis standar pada praktik klinis. Pemeriksaan objektif lainnya belum dapat menggantikan pemeriksaan ICG untuk evaluasi sirkulasi flap bebas.

The risk of failure in free flap reconstruction may occur due to small vascularization. Clinical examination, which is the gold standard for free flap evaluation, is subjective and difficult to detect early vascularization problems. Indocyanine green (ICG) is an objective instrument to evaluate flap circulation, but there is no ICG consensus and the fluorescence emitted is dose-dependent. In the preliminary studies conducted in vitro followed by in vivo with animal models, we found that 0.5 mg/mL concentration produced equivalent fluorescence to the standard concentration (5 mg/mL). This study aimed to analyze the titration dose of ICG to evaluate free flaps using a standard near-infrared radiation camera and its correlation with the examination of flap temperature, TcPCO2, TcPO2, HIF-1α levels, and histopathological to support reconstructive microsurgery procedure. This was a randomized, double-blind clinical trial at Dr. Cipto Mangunkusumo National Central General Hospital and Persahabatan Hospital from September 2022 to January 2024. A total of 63 patients that met the inclusion criteria through screening questionnaire were randomized into 3 ICG concentration groups: 5 mg/mL, 2.5 mg/mL, and 0.5 mg/mL. The ICG was given intravenously to each group which consist of 21 subjects. The data were obtained immediately postoperative, 24 hours, 72 hours, and 120 hours post-operative. There were 63 flaps divided into three groups with 21 flaps each. All three groups showed an increase in ICG fluorescence over time, with fluorescence intensity emitted by 2.5 mg/mL concentration is equivalent to the standard concentration (p = 0.792), but the fluorescence from 0.5 mg/mL concentration emitted weaker intensity (p = 0.006 and p = 0.041). Fluorescence intensity did not correlate with other objective examinations. It was concluded that the titration dose of ICG influenced the fluorescence intensity due to quenching effect and ICG and plasma protein bond equilibrium. Analysis of 5 mg/mL and 2.5 mg/mL concentration groups produced similar intensities, leading to the feasibility of 2.5 mg/mL concentration to replace the standard dose in clinical practice. Other objective examinations can not replace ICG examination for free flap perfusion evaluation."
Depok: Fakultas Kedokteran Universitas Indonesia, 2024
D-pdf
UI - Disertasi Membership  Universitas Indonesia Library
cover
Evelyn
"Amplifikasi isotermal merupakan metode yang popular pada saat ini sebagai alternatif PCR (polymerase chain reaction) untuk melakukan amplifikasi asam nukleat. Tidak seperti PCR yang memerlukan perubahan suhu siklik, amplifikasi dapat dilakukan pada suhu konstan dalam metode amplifikasi isotermal. Salah satu metode amplifikasi isotermal yang sangat banyak diaplikasikan adalah loop-mediated isothermal amplification (LAMP). Sejak pertama kalinya ditemukan pada tahun 2000, LAMP dimanfaatkan secara luas untuk deteksi berbagai jenis patogen. Dalam penelitian ini, dirancang suatu prototipe yang dapat memfasilitasi reaksi LAMP. Prototipe terdiri dari dua sistem: sistem pemanas yang berfungsi untuk menyediakan suhu konstan 60oC terhadap sampel untuk aplikasi LAMP dan sistem deteksi optik berbasis fluoresens yang digunakan untuk melakukan kuantifikasi intensitas fluoresens dalam 6 tabung sampel 0,5mL dengan kadar fluorescence agent 0,5mL, 0,4mL, 0,3mL, 0,2mL, 0,1mL, dan 0mL. Agar panas dapat disalurkan sampel dengan baik, dirancang sebuah blok panas (heat block). Selain itu, sebuah housing prototipe juga dirancang untuk menyokong komponen dan mendukung proses deteksi fluoresens. Berdasarkan hasil penelitian ini, sistem pemanas sederhana menggunakan kontrol PID dan blok panas yang dirancang mampu mempertahankan suhu pada setpoint 60oC dan 65oC, sehingga dapat digunakan untuk aplikasi LAMP. Selain itu, sistem optik yang dirancang mampu memfasilitasi proses deteksi optik berbasis fluoresens. Proses kuantifikasi intensitas fluoresens menunjukkan bahwa intensitas emisi fluoresens proporsional terhadap kadar fluorescence agent dalam sampel, dimana sampel dengan total volume 0,5mL pada kadar fluorescence agent 0,5mL, 0,4mL, 0,3mL, 0,2mL, maupun 0,1mL dapat menghasilkan emisi cahaya dengan nilai keabuan minimal 121,179.

Isothermal amplification is a popular method today as an alternative to PCR (polymerase chain reaction) for nucleic acid amplification. Unlike PCR which requires cyclic temperature changes, amplification can be carried out at a constant temperature in the isothermal amplification method. One of the most widely applied isothermal amplification methods is loop-mediated isothermal amplification (LAMP). Since it was first discovered in 2000, LAMP has been widely used to detect various types of pathogens. In this research, a prototype is designed that can facilitate the LAMP reaction. The prototype consists of two systems: a heating system which serves to provide a constant temperature of 60oC to the sample for the LAMP application and a fluorescence-based optical detection system which is used to quantify the fluorescence intensity in 6 sample tubes of 0.5mL with fluorescence agent content of 0.5mL, 0.4mL, 0.3mL, 0.2mL, 0.1mL, and 0mL. In order for heat to be transferred to the sample properly, a heat block is designed. In addition, a prototype housing is also designed to support components and support the fluorescence detection process. Based on the results of this study, the designed simple heating system with PID control and heating block are able to maintain a temperature at a setpoint of 60oC dan 65oC, so it can be used for LAMP applications. Moreover, the designed optical system is able to facilitate fluorescence-based optical detection process. The fluorescence intensity quantification process showed that fluorescent emission intensity is proportional to the content of fluorescence agent in the sample, where the sample with total volume of 0.5mL in which the fluorescence agent content is 0.5mL, 0.4mL, 0.3mL, 0.2mL, and 0.1mL can generate light emission with gray value of minimal 121.179."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fadhlir Rahman Aufar Al Fatah
"Senyawa natrium hipoklorit merupakan senyawa umum yang digunakan sebagai bahan disinfektan pada air keran dan air kolam renang. Pada penelitian ini nanopartikel Silika-MB@GO-NH2 disintesa dan digunakan sebagai paper based sensor dengan metode fluoresensi dalam deteksi senyawa NaOCl murni serta sampel air keran, dan air kolam renang yang diuji dibawah sinar lampu UV-A. Hasil karakterisasi FTIR diamati adanya puncak serapan yang mengindikasikan keberadaan nanopartikel Silika-MB@GO-NH2. Pengujian Spektroskopi Raman menunjukan puncak D band dan G band dengan rasio yang menandakan keberadaan dari GO-NH2 serta Silika-MB@GO-NH2. Untuk mengetahui panjang gelombang terhadap %R, dilakukan uji dengan UV-DRS pada paper based sensor dengan variasi konsentrasi NaOCl dan dihasilkan sebesar 367.282 nm^-1 serta pada uji sampel air keran dan air kolam renang sebesar 388.704 nm^-1 yang menunjukan bahwa nanopartikel tersebut mengabsorpsi cahaya pada daerah sinar ultraviolet (UV). Pada pengujian paper based sensor dibawah lampu UV-A menunjukan cahaya hanya sedikit yang berpendar dan menjelaskan respon kurang baik pada paper based sensor. Data optimasi dan kurva kalibrasi linier terhadap uji interferensi logam Cu dengan nilai y = 0.1204x + 0.0385, dan konsentrasi nya sebesar 0.455 mg / L. Pada logam Fe dengan nilai y = 0.0519x + 0.031 dan konsentrasi sebesar 0.597 mg / L. Pada uji interferensi peroksida di air keran sebesar 0.25 mg / L dan dikolam renang sebesar 0.552 mg / L. Pada interferensi senyawa klorida di air keran didapatkan sebesar 420.165 mg / L dan dikolam renang sebesar 422.215 mg / L.

Sodium hypochlorite (NaOCl) is common compounds used as a disinfectant in aquatic environments, such as tap water and swimming pool water. In this study, Silica-MB@GO-NH2 nanoparticles were synthesized and applied for paper based sensors, based on fluorescence method under UV-A exposure, for the detection of of pure NaOCl, tap water, and swimming pool samples. The results of FTIR characterization show the absorption peaks showed the formation of Silica-MB@GO-NH2 nanoparticles. Raman spectroscopy result depict the presence of peaks in the D band and G band with a ratio of which indicating the presence of GO-NH2 and Silica-MB@GO-NH2. To determine the wavelength of %R, a UV-DRS test was carried out on a paper-based sensor with variations in NaOCl concentration and the result was 367,282 nm ^-1 and the sample test for tap water and swimming pool water was 388,704 nm^-1 which depict that it can absorb light in the ultraviolet (UV) region. In testing the paper based sensor under a UV-A lamp, it shows that only a little light glow and explains the poor response to the paper based sensor. Then obtained optimization data and linear calibration curve for the interference test for Cu metal with a value of y = 0.1204x + 0.0385, and its concentration is 0.455 mg / L. The Fe metal with a value of y = 0.0519x + 0.031 with a concentration of 0.597 mg / L. In the peroxide interference test in tap water of 0.25 mg / L and in the swimming pool of 0.552 mg / L. On the interference of chloride compounds in tap water it was obtained at 420,165 mg / L and in the swimming pool at 422.215 mg / L."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
"We present the emission behavior of an elastic fluorescent material based on silicone doped wirh rhodamine 6G at 1.2 x103 M..Fluoresence properties of the material are modified by deformation, suggesting possible use of the material as a strain sensor...."
Artikel Jurnal  Universitas Indonesia Library
cover
New York : Academic Press, 1983
535.84 ULT
Buku Teks  Universitas Indonesia Library
cover
Orlando: Academic Press, 1984
570.72 OPT
Buku Teks  Universitas Indonesia Library
cover
M Akib Khu
"Analisis spektrokimia pada sampel besar seperti plat logam telah dilakukan dengan menggunakan sebuah ruang oakum kecil yang terhubung secara langsung dengan permukaan sampel melalui cincin berbentuk O. Teknik ini menghasilkan plasma yang dapat digunakan untuk analisis in-situ, sehingga prosedur penyiapan sampel yang relatif kurang praktis dapat diatasi. Di samping itu, dengan adanya cincin O yang menempel pada sampel, secara effektif menghalangi emisi kontinu yang tidak diinginkan dari plasma primer, sehingga meningkatkan sensitifitas deteksi dari teknik ini. Selanjutnya dalam eksperimen ini spektrum yang didapatkan dengan menggunakan sistem OMA tanpa fungsi gating masih menunjukkan sinyal latar belakang yang lebih rendah daripada yang didapatkan dengan metode LIBS (Laser induced Breakdown Spectroscopy).
"
2000
T3684
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>