"Tujuan utama penelitian ini difokuskan pada presurisasi tangga kebakaran dan pengendalian asap di ruang berukuran besar. Sebanyak 180 artikel akademik yang diterbitkan antara 1964 sampai 2022 ditinjau untuk merangkum strategi sistem presurisasi dan ekstraksi asap yang berkaitan dengan keselamatan berbasis kinerja di bangunan gedung. Dampak perbedaan tekanan dalam tangga darurat terhadap luar diteliti ada gedung perkantoran aktual 32 lantai. Pressurized-fan injeksi tunggal dipasang di atas ruang tangga. Sensor tekanan juga dipasang di lima lantai terpisah. Selanjutnya lima skenario pengujian dilakukan untuk mengukur perbedaan tekanan antar tangga dan koridor dengan beberapa pintu terbuka di berbagai lantai. Hasil pengujian menunjukan perbedaan tekanan sebesar 5-15 Pa diperoleh dari pengukuran lapangan dan perbedaan tekanan 10-20 Pa diperoleh melalui analisa numerik dengan kode FDS (Fire Dynamic Simulator). Analisa numerik juga menunjukkan distribusi tekanan di sepanjang tangga lebih merata dengan sistem presurisasi multi-injeksi. Dalam mempelajari manajemen asap di ruang berukuran besar, sebuah kompartemen berskala 1/10 berukuran 2,4m x 1,6m x 1,0m dan berlantai dua dengan sebuah lantai mezzanine dijadikan sebagai model eksperimen. Sumber asap berasal dari pembakaran sabut kelapa. Piranti lunak FDS juga digunakan untuk membandingkan hasil investigasi secara eksperimental dan analisis numerik. Analisa numerik FDS memperkirakan kenaikan obskurasi asap dan kenaikan temperatur lebih tinggi tinggi daripada yang diperoleh dari hasil pengujian. Meskipun banyak penelitian sebelumnya telah memberikan solusi untuk manajemen asap, kreativitas manusia dalam desain berkembang lebih cepat daripada regulasi atau pedoman sebelumnya sehingga diperlukan pendekatan berbasis kinerja dalam merancang sistem keselamatan kebakaran.

The primary aim of the research is focused on stairway pressurization systems and smoke control in large-volume spaces. A total of 180 academic publications published between 1964 and 2022 were included to summarize the practical applications of smoke control strategies based on pressurization or extraction systems, and potential research pertaining to performance-based safety schemes for smoke ventilation control in tall buildings. In an actual 32-story office building, the impact of a pressure differential over the stairs was studied. The single injection pressurized fan on the top of the stairwell and pressure sensors were on five separate floors to measure the pressure differential over time. Five scenarios are tested to observe the impact of differential pressure caused by an open door on various floors. The pressure difference between the stairwell and outside is 5 to 15 Pa gained in field measurements and 10 to 20 Pa in numerical studies. The numerical research also demonstrates that the pressure distribution along the stairs performed better for the multi-injection system. To explore smoke management in large volume spaces, another reduced-scale model of two levels with a mezzanine floor was developed using a 1/10 reduced-scale experimental compartment 2.4m x 1.6m x 1.0m. The smoke in the compartment was created by the combustion of coconut husks. Comparing experimental investigations to numerical analysis using FDS codes. The numerical calculations overestimate the rise in obscuration during the time of smoke accumulation. The increase in temperature simulated by FDS is also more than that observed by testing. While designing a smoke control system, it is necessary to use a performance-based approach."
Depok: Fakultas Teknik Universitas Indonesia, 2023
D-pdf
UI - Disertasi Membership  Universitas Indonesia Library
cover
Sudarman
"Fire safety merupakan faktor penting dalam desain gedung bertingkat tinggi. Asap diakui sebagai pembunuh utama dalam situasi kebakaran. Oleh karena itu, dibutuhkan adanya sistem pengendalaian asap seperti sistem pressurusasi dan exhaust. Sistem pressurized smoke stop lobby dan sitem exhaust fan diharapkan dapat mengurangi adanya korban jiwa dalam kebakaran. Faktor penting lain dalam desain safety adalah waktu deteksi asap sehingga korban dapat dievakuasi sebelum asap masuk ke tangga darurat.

Fire safety is an important factor in the design of high-rise buildings. Smoke is recognized as a major killer in fire situations. Therefore, it is necessary to have smoke control systems such as pressurized and exhaust systems. Smoke stop lobby pressurized system and theexhaust system is expected to reduce victim in fires. Another important factor in the design of safety is a smoke detection time, so that the victim can be evacuated before smoke into the emergency stairs."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S53033
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adhi Saputra
"Kebakaran adalah sesuatu bencana yang sangat sering terjadi. Laboratorium Forensik Markas Besar Kepolisian Republik Indonesia (Puslabfor Mabes Polri) menyebutkan kebakaran yang terjadi di Indonesia periode 1990 ? 1996 adalah 2033 kasus dan tahun 1997 ? 2001 sekitar 1121 kasus. Sedangkan NFPA (National Fire Protection Association) menyebutkan pada tahun 2002 kebakaran di Amerika Serikat 1.687.500 kasus dan di Inggris 519.400 kasus. Dampak yang diakibatkannya juga mencapai tingkat yang mengkhawatirkan.
Seperti yang dilaporkan oleh NFPA pada tahun 2002 dari total kebakaran yang terjadi menyebabkan orang meninggal dunia di Amerika sekitar 3.380 orang dan luka 18.425 orang. Sedangkan di Inggris orang meninggal akibat kebakaran adalah 562 orang dan 16.595 orang terluka. Pada tesis ini dilakukan pengkajian (analisis) bahaya kebakaran bangunan khususnya bahaya asap serta penanggulangannya. Bangunan dievaluasi dengan menggunakan bantuan perangkat lunak FDS. Adapun tujuan dari tesis ini adalah untuk memahami berbagai macam skenario kebakaran serta untuk menciptakan bangunan ruko yang aman. Dari hasil simulasi yang dilakukan terbukti dengan menggunakan smoke shaft dapat mengurangi kepekatan asap mencapai 83%, sehingga penghuni mendapatkan waktu evakuasi yang lebih panjang.

Fire is a disaster that most occur in the world. Laboratory of Indonesian Police Department say fire occur in Indonesia during 1990 ? 1996 are 2033 case, and during 1997 ? 2001 are 1121 case. NFPA (National Fire Protection Association) say fire occur in USA at 2002 are 1.687.500 case and in UK 519.400 case. Impact of the fire are very serious.
As reported by NFPA at 2002 from total of fire that occur in USA causes 3.380 people die and 18.425 people injury, in UK 562 people die and 16.595 people injury In this thesis make analyze of fire building hazard specially smoke hazard and how prevent it. The software that used to evaluate this smoke hazard is Fire Dynamics Simulator (FDS). The objective of this thesis are to understand some fire scenario and creating a safe shophouse from smoke hazard. Result of this simulation prove that using smoke shaft can reduce of soot density until 83%, so occoupant get longer evacution time."
Depok: Fakultas Teknik Universitas Indonesia, 2007
T24380
UI - Tesis Membership  Universitas Indonesia Library
cover
Marlian
"The Fire damage occurs in unpredictable time and can cause losses to the owner because of the damage. It can occur in buildings that do not have Fire Protection and Fire Safety Management System in the building. By detecting and preventing against fire damage, which arise in unpredictable times will prevent loss of lives and assets of the buildings.
There has been considerable research into the fire damage such as at the Polo Condominium in Colorado. The Polo Condominium that was built in 1967 caught fire on October 31' because it did not have the Fire Protection System in each floor. When the fire came and burned the building interior, the building could not extinguish the fire because it did not have fire detector and sprinklers in place.
To solve the problem, in Jakarta there are a lot of guidelines such as the Minister Of Public Works Decree # 02IKPTSI1985 for Fire Safety in building. But from many fire damages, the guidelines could not accommodate the problem because the buildings did not incorporate Fire Protection and Fire Safety Management System. Relevant research indicated that Fire Protection and Fire Safety Management System are very important to detect and prevent against fire damage. In this research, the Fire Protection and Fire Safety Management System are defined as Fire Safety Design which have been taken from many relevant theories and journals.
From 50 questionnaires sent to various high rise office buildings in Jakarta, 30 responses were received to be viable for in depth analysis. The result of the analysis shows clearly that the Fire Safety Design is positively correlated in a linear manner to four of the key Fire Safety Design variables. The four key variables influencing building reliability in design carried out by the consultant and controlled by the construction manager in the projects are : detection and fire alarm, building architecture, the designer's fire certificate and special equipment to stop fire_ This research can then be used to control and measure the quality of Future Fire Safety Design of the high rise building reliability in Jakarta."
Depok: Fakutlas Teknik Universitas Indonesia, 2000
T676
UI - Tesis Membership  Universitas Indonesia Library
cover
Nur Laeli Khoirun Ni`Mah
"Kebakaran hutan adalah pemasalahan lingkungan yang muncul hampir setiap tahun di Indonesia termasuk di TNGC. Kebakaran hutan dapat berdampak negatif pada ekologi, perubahan komposisi dan struktur ekosistem hutan, serta dapat mengganggu kegiatan ekonomi masyarakat. Permasalahan dalam kajian ini adalah kegiatan pengendalian kebakaran hutan di TNGC telah melibatkan masyarakat peduli api, tetapi hasilnya belum maksimal yang ditandai masih seringnya terjadi kebakaran hutan di kawasan TNGC. Tujuan penelitian ini adalah menganalisis faktor yang mempengaruhi partisipasi MPA, menganalisis hubungan antara partisipasi dengan keberlanjutan manfaat taman nasional, merumuskan model dan strategi peningkatan partisipasi MPA dalam pengendalian kebakaran hutan. Metode yang digunakan adalah mix-method yang dilakukan melalui analisis regresi liner dan SWOT analisis.
Kesimpulan dari penelitian ini adalah faktor motivasi, kemampuan, dan kesempatan secara signifikan mempengaruhi partisipasi masyarakat peduli api. Oleh karena itu, model peningkatan partisipasi MPA dapat dibangun melalui ketiga variabel tersebut. Keberlanjutan taman nasional memiliki hubungan yang cukup kuat, signifikan dan searah dengan partisipasi dengan nilai korelasi 0,331. Rumusan peningkatan partisipasi masyarakat peduli api dalam pengendalian kebakaran hutan dari hasil analisis SWOT menunjukkan bahwa kondisi pengelolaan Balai Taman Nasional Gunung Ciremai berada pada kuadran I Diagram Kartesius. Strategi prioritas yang dilaksanakan adalah aggressive strategy.

Forest fires are environmental problems that appear almost every year in Indonesia, including in TNGC. Forest fires can have a negative impact on ecology, changes in the composition and structure of forest ecosystems, and may disrupt the economic activities of the people. The problem in this study is that forest fire control activities in TNGC have involved the community to care about fire, but the results have not been maximally marked by the frequent occurrence of forest fires in the TNGC area. The purpose of this thesis is to analyze the factors that influence the participation of the fire caring community, analyze the relationship between participation with the sustainability of the park 39 s benefits, formulate models and strategies to increase the participation of fire fighting public in fire control. The method used is mix method done through linear regression analysis and SWOT analysis.
Conclusion of the study, motivation, ability, and opportunity significantly influence the participation of the public concerning fire. Therefore, the MPA participation enhancement model can be built through these three variables. The sustainability of the park has a strong, significant and unidirectional relationship with participation with a correlation value of 0.331. The formulation of the increased participation of the public concerning fire in forest fire control from the SWOT analysis shows that the condition of the management of Gunung Ciremai National Park is in the first quadrant of Cartesian Diagram. The priority strategy implemented is aggressive strategy.
"
Jakarta: Program Pascasarjana Universitas Indonesia, 2017
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Tommy Novianto
"Stasiun MRT merupakan salah satu tempat umum yang memiliki jumlah pengguna yang banyak sehingga aspek mengenai keselamatan penumpang wajib untuk diperhatikan. Beberapa tahun kedepan pembangunan MRT di Jakarta akan selesai dimana 5-6 stasiun yang ada akan berada di bawah tanah. Manajemen keselamatan kebakaran di bawah tanah lebih rumit daripada stasiun yang ada di permukaan ataupun melayang sebab persebaran asap searah dengan jalur evakuasi. Tujuan dari penelitian ini adalah untuk mengetahui bagaimana dinamika asap yang terjadi pada kebakaran stasiun MRT ketika memanfaatkan tunnel sebagai tempat membuang asap tambahan.
Batasan dalam penelitian ini adalah sistem tunnel telah memiliki sistem ventilasi yang baik sehingga saat ada asap di tunnel segera bisa di buang ke permukaan dengan sistem ventilasi yang ada. Metode yang digunakan dalam penelitian ini adalah simulasi dengan menggunakan FDS v.5 dan ekperimen menggunakan model stasiun dengan skala 1 :25. Variasi dilakukan pada penggunaan ventilasi blower dan jumlah fan samping yang digunakan. Diharapkan dengan adanya pembuangan asap kedalam tunnel membuat kondisi didalam stasiun bisa lebih baik.

MRT station is one of the public facility that has a lot of users, therefore aspects of passenger safety are required to be considered. In the next few years, Jakarta’s MRT construction will be finished. There will be 5-6 stations located underground. Fire safety management in the underground station is more complicated than the existing stations on the surface, because the spread of smoke drift in the same direction as the evacuation route. The purpose of this research is to learn about smoke dynamics that occur in fires at MRT station when utilizing the tunnel as a place to dispose smoke.
Limitation in this study is the tunnel system already has a good ventilation system so that when there is smoke in the tunnel, it can be disposed to the surface with the existing ventilation system immediately. The method used in this research is simulated using FDS v.5 and experimented using the model of the station with a scale of 1: 25. Variations are performed by using blower ventilation and the amount of side fan that is used. Hopefully, disposing smoke into the tunnel make the conditions inside the station better.
"
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59087
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sony Virawan Sonata
"ABSTRAK
Penelitian ini bertujuan untuk mengevaluasi kesesuaian sistem proteksikebakaran
pada rancangan bangunan gedung RSPTN UI. Penelitian deskriptif inidilakukan
dengan telaah dokumen. Metode yang digunakan adalah evaluasi menggunakan
checklist sesuai dengan Permen PU No.26/PRT/M/2008, Perwal Depok No. 14
Tahun 2012, Pedoman Teknis Prasarana Rumah Sakit yang dikeluarkan oleh
Kemenkes pada tahun 2012, serta Standar Nasional Indonesia (SNI). Penelitian ini
juga mengambil contoh kasus di ruang operasi untuk dibahas lebih mendalam.
Hasil dari penelitian ini menunjukkan bahwasebagian besar sistem proteksi
kebakaran pada rancangan bangunan gedung RSPTN UI telah sesuai dengan
peraturan pemerintah Indonesia. Sistem proteksi kebakaran yang belum seluruh
persyaratannya terpenuhi yaitu pintu eksit, detektor dan alarm kebakaran, sistem
pipa tegak, alat pemadam api ringan, dan lif kebakaran. Oleh karena itu,
diperlukan penyesuaian rancangan sistem proteksikebakaran tersebut agar sesuai
dengan peraturan pemerintah Indonesia.

ABSTRACT
The aim of this study is to evaluate the compliance of fire protection system
design in RSPTN UI in accordance to Indonesian goverment’s regulations. This
descriptive study was conducted with document review. The method used is the
evaluation in accordance with Permen PU No. 26/PRT/M/2008, Perwal Depok
No. 14 Year 2012, Technical Guideline of Hospital Facility, Ministry of Health,
Year 2012, and Indonesian National Standard (SNI). Checklist from these
regulation had been developed and utilized as the tool for this study. This study
also took a sample of cases in the operating room as a case study. The results of
this study indicate that the majority of fire protection systems in RSPTN UI
design is complied with Indonesian government regulations. Fire protection
systems that not meet all the requirements are exit doors, detectors and fire alarm,
standpipe systems, fire extinguisher, and fire elevator. Therefore, the necessary
adjustments to the design of the fire protection system to suit the Indonesian
government regulations. Therefore, required fire protection system design
adjustment to suit the Indonesian goverment regulation."
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2014
T42786
UI - Tesis Membership  Universitas Indonesia Library
cover
"Selama tahun 2013, detektor kebakaran di instalasi radiometalurgi (IRM) sering mengirimkan sinyal ganguan ke panel kantrol kebakaran (FCP), sehingga timbul bunyi alarm palsu. Oleh karena itu diperlukan pemeriksaan secara keseluruhan pada detektor kebakaran yang terpasang di IRM tersebut. Tujuan dilakukannya pemeriksaan detektor asap dan panas adalah untuk memastikan bahwa sistem deteksi kebakaran IRM beroperasi seperti yang diharapkan. Metoda yang digunakan adalah memeriksa koneksi kabel di FCP, kotak hubung utama (FMDF) dan kotak hubung (JBFA). Masing-masing zona detektor pada FMDF dan JBFA, tegangan operasinya diukur. Tegangan operasi detektor pada zona 1, 13, 20, 41, 61, 77, 78 dan 101 cukup rendah, yaitu 21.80 -22.60 V. Tegangan operasi FCP ideal bekerja pada 24 V untuk masing-masing zona detektor. Dari pemeriksaan lebih lanjut, diketahui bahwa terdapat 10 unit detektor panas, dan 9 unit detektor asap tidak berfungsi. Untuk menggantikan detektor lama yang tidak berfungsi, telah dipasang detektor baru : 9 unit detektor panas dan 4 unit detektor asap. Detektor yang belum diganti diantaranya : 1 unit detektor panas, dan 5 unit detektor asap, namun telah dipasangi resistor 10 k untuk mencegah timbulnya alarm palsu. Dari hasil uji detektor, disimpulkan bahwa sistem deteksi kebakaran IRM, telah beroperasi dengan baik."
PIN 8:15 (2015)
Artikel Jurnal  Universitas Indonesia Library
cover
Refaldo Fanther
"Penelitian tentang pengaruh pemberian tekanan (presurisasi) terhadap opasitas asap pada ruang tangga kebakaran di gedung bertingkat tinggi dilakukan pada suatu model gedung bertingkat dengan sistem presurisasi berukuran 70 cm x 65 cm x 200 cm menggunakan skala 1:20 dibandingkan dengan desain gedung bertingkat tinggi yang sebenarnya. Penelitian ini bertujuan untuk mempelajari pengaruh dari jumlah pintu terbuka di dalam ruang tangga bertekanan terhadap opasitas asap di gedung bertingkat tinggi. Penggunaan tekanan melalui pemberian suplai udara di dalam ruang tangga kebakaran adalah sebagai salah satu bentuk sistem pengendalian asap yang beertujuan untuk mencegah asap memasuki ruang tangga pada saat kebakaran. Penggunaan presurisasi pada ruang tangga juga disimulasikan dengan desain gedung yang sebenarnya, menggunakan Fire Dynamic Simulator (FDS Ver. 5.0). Data yang diperoleh melalui eksperimen pada model akan dibandingkan dengan hasil analisis yang dilakukan pada simulasi. Hasil dari penelitian ini adalah sistem ruang tangga kebakaran terbukti menurunkan tingkat opasitas asap, sehingga dapat diaplikasikan untuk mencegah asap kebakaran pada gedung bertingkat tinggi.

Experimental work on the effect of pressurized system on optical density of smoke in a high rise building was studied using a model with the size 70 cm x 65 cm x 200 cm. This represents a scaling factor of 1:20 compared to the typical building size. This study aims to study the influence of the number of open doors in the pressurized stairwell to the optical density of smoke in the high-rise buildings. The pressurization through the provision of air supply in the stairwell is as one of smoke control systems that aim to prevent smoke from entering the stairwell during a fire. The effect of pressurization on the stairwell was also simulated with the actual building design, using the Fire Dynamic Simulator (FDS Ver. 5.0). The data obtained through experiments on the model were compared with the results of analyzes performed on the simulation. The result of this research is the pressurized stairwell system was proven to decrease optical density of smoke, therefore it can be applied to prevent smoke of fire in high rise building."
Depok: Fakultas Teknik Universitas Indonesia, 2012
S43351
UI - Skripsi Open  Universitas Indonesia Library
cover
Narwoko
"ABSTRAK
Kejadian kebakaran sering terjadi di wilayah perkotaan termasuk di Kota Depok, dimana untuk mencegah dan menanggulanginya Pemda Depok membentuk Dinas Pemadam Kebakaran (damkar) sesuai konsep Wilayah Manajemen Kebakaran (WMK). Banyak tantangan yang dihadapi organisasi damkar dalam mencapai tujuannya antara lain kemacetan, keterbatasan sumber air, sarana dan prasarana, tata kota serta kurangnya kesadaran masyarakat. Organisasi merupakan sistem sosioteknikal yang harus memenuhi prinsip-prinsip sosioteknikal agar berfungsi dengan baik. Penelitian ini membahas struktur sistem kerja organisasi damkar dari perspektif makroergonomi dengan pendekatan deskriptif kualitatif. Hasil penelitian mengindikasikan adanya ketidaksesuaian struktur organisasi dengan prinsip-prinsip sosioteknikalnya yaitu pada dimensi formalisasi, kompleksitas, sentralisasi serta elemen profesionalismenya

ABSTRACT
Fire incident is still occurred in city area including City of Depok, to prevent such incidents, Government of Depok has established fire department with area of fire management concepts (Wilayah Manajemen Kebakaran-WMK). There are challenges to fire department organization including traffic congestion, limited water sources and facilities, city planning and low community awareness. Organization is sociotechnical system that needs to meet sociotechnical principles to ensure good functioning. The study analyze work system structure of fire department organization from macroergonomic perspective utilizing descriptive qualitative approach. Result of study reveals some nonconformity against its sociotechnical principles on formalization, complexity, and centralization dimension as well as its professionalism element"
2016
T46753
UI - Tesis Membership  Universitas Indonesia Library