cover
Teerachai Howongsakun
"The objective of this research was to study the effects of highly moist inlet air conditions such as temperature, relative humidity, and frontal air velocity on the value of the Lewis number (Le) in the cooling and dehumidifying process of air. A finned tube cooling coil was tested under ranges of temperature, relative humidity and frontal velocity. It was found that the Lewis number (Le) varied within the range of 0.92−1.62 and that the increase in inlet air relative humidity tends to decrease the Lewis number (Le). Based on the experimental, a correlation for predicting the Lewis number (Le) was also established in this article. The correlation has the mean absolute error (MAE) of 3.04% and covers 98.07% of the data where a discrepancy within ± 10%."
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:7 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Howongsakun, Teerachai
"The objective of this research was to study the effects of highly moist inlet air conditions such as temperature, relative
humidity, and frontal air velocity on the value of the Lewis number (Le) in the cooling and dehumidifying process of air. A finned tube cooling coil was tested
under ranges of temperature, relative humidity and frontal velocity. It was
found that the Lewis number (Le) varied within the range of 0.92-1.62 and that the increase in inlet air relative humidity tends to
decrease the Lewis number (Le). Based on the
experimental, a correlation for predicting the Lewis number (Le) was also established in this article. The
correlation has the mean absolute error (MAE) of 3.04% and covers 98.07% of the data where a discrepancy within ± 10%."
2016
J-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
Citrani Prameswari
"Telah dibuat alat ukur kelembaban udara dengan menggunakan humidity sensor tipe HSP15P dengan keluaran yang diukur berupa tegangan. Besarnya impedansi yang terukur pada percobaan tergantung pada perubahan kelembaban. Semakin besar kelembaban maka semakin besar impedansi. Reaktansi kapasitif pada sensor yang disebabkan oleh kadar uap air di udara, memberikan pengaruh pada besarnya keluaran yang diukur. Pada percobaan juga dilakukan pengambilan data menggunakan sensor SHT11 sebagai referensi. Rangkaian yang dipergunakan berfungsi untuk mempermudah pembacaan keluaran pada multimeter."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
TA626
UI - Tugas Akhir  Universitas Indonesia Library
cover
Bagus Ragil Kurniawan
"Indonesia merupakan negara beriklim trpois dengan temperatur udara berkisar 28°C-35°Cdengan kelembaban Relative Humidity 70%-90%. Sedangkan kondisi nyaman udara pada suatu ruangan yaitu pada temperature 22°C-25°C dengan kelembapan relative humidity 40%-60%. Oleh karena itu pengkondisian udara merpakan sebuah solusi atas permasalahan tersebut. Hampir semua pengkondisian udara di Indonesia dilakukan dengan cooling dan dehumidification. Pada perkembangan beberapa akhir tahun ini, biaya operasional bangunan telah habis hingga 60% digunakan untuk pengkondisian udara. Aplkasi Heat pipe dalam pengkondisian udara telah banyak diterapkan. Heat pipe merupakan sebuah alat heat exchanger dengan kemampuan transfer panas yang sangat baik. Heat pipe dapat berfungsi sebagai precooler dan reheater serta berperan dalam menurunkan relative humidity.

Indonesia have a tropic climate with 28°C-35°C in temperature and 70%-90% in Relative Humidity. Comfortable condition of air in building is about 22°C-25°C and relative humidity 40%-60%. So, air conditioning which in Indonesia using cooling and dehumidification system is a solution. But the cost of air conditioning is very expensive and almost spend 60% of operational cost. So, heat pipe application in heat exchanger for air conditioning is often used. Heat pipe have a good ability in heat exchanger. It's function for precooling, reheating and also dehumidification in air conditioning."
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42845
UI - Skripsi Open  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 2000
S37185
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aris Manga
"ABSTRAK
Teknik refrijerasi dengan penyerapan, yang menggunakan energi kalor yang rendah dan mampu menghasilkan pengkondisian udara serta efek refrijerasi, mendapatkan perhatian besar sebagai bagian dari teknologi konversi energi. Teknologi refrijerasi dengan penyerapan mencakup teknologi absorpsi dan teknologi adsorpsi. Naskah ini mempresentasikan desain terbaru chiller adsorpsi silica gel/air yang dikembangkan di Departemen Teknik Mesin, Universitas Indonesia. Konfigurasi chiller terdiri dari dua ruang penyerapan, dengan menggunakan rectangular finned-tube heat exchanger sebagai adsorber, kondenser and evaporator. Chiller diuji pada kondisi temperatur hot water inlet/cooling water inlet sebesar 65/30 C. Heat dan mass recovery diadopsi dalam eksperimen untuk meningkatkan kapasitas pendinginan masing-masing dengan waktu 40 dan 20 detik. Waktu siklus pendinginan pada 800,700,600 dan 500 detik untuk menghasilkan waktu optimal yang berkaitan dengan performa. Nilai rata-rata COP, SCP dan kapasitas pendinginan dihitung untuk mendapatkan performa chiller secara keseluruhan masing-masing 0,6 kW; 0,7 kW/kg dan 3 kW.Kata kunci: chiller adsorpsi; heat recovery; mass recovery; performa; penyerapan; silica gel/air

ABSTRACT
Sorption refrigeration, which is driven by the lowgrade heat and provides the air conditioning and refrigeration effect, is paid more and more attention as one of the energy conversion technologies. Sorption technology includes absorption and adsorption technology. This paper presented a new design of silica gel water adsorption chiller which is developed in Mechanical Engineering Department, University of Indonesia. The chiller design configuration is composed of two sorption chamber, with compact rectangular finned tube heat exchanger as adsorber, condenser and evaporator. The chiller is tested under typical condition for hot water inlet cooling water inlet 65 30 C, respectively. Heat and mass recovery were adopted in experiment to increase the cooling capacity time are 40 and 20 s, respectively. The cooling time were 800,700,600 and 500 s to obtain the optimum cooling time related to the performance. Average value of COP, SCP and cooling power were calculated to obtain overall performance of the chiller are 0.6 kW 0.7 kW kg and 3 kW, respectively.Keywords adsorption chiller heat recovery mass recovery performance silica gel water sorption"
2016
T47239
UI - Tesis Membership  Universitas Indonesia Library
cover
Sintong, Jeremy Ericsson
"Penelitian ini memuat simulasi permodelan adsorpsi di fin tube adsorbent bed. Permodelan komputasi didasarkan pada persamaan konservasi massa, momentum, dan energi pada adsorbent bed yang terdiri atas fin, tube, dan adsorber. Metode simplifikasi dari simulasi dibuat dengan 2 buah fin, 1 buah tube, air dengan temperatur tinggi sebagai adsorbat, dan silika gel yang terisi penuh pada bed sebagai adsorber. Simulasi juga diimplementasikan menggunakan metode volume hingga melalui Computational Fluid Dynamics CFD pada program Fluent. Metode User Defined Function UDFs dimuat pada program Fluent untuk memberikan batasan kondisi dan merekayasa persamaan adsorpsi yang tidak didefinisikan di Fluent. Simulasi unsteady di keseluruhan bed pada kondisi inisiasi awal saat t = 25 detik, adsorpsi absolut dengan konsentrasi tertinggi berada di kuantitas 0.0846 mol/kg pada bagian tepi sedangkan konsentrasi terendah berada di kuantitas 0.0065 mol/kg pada bagian pusat. Pada saat t = 525 detik, konsentrasi adsorpsi absolut tertinggi berada di pusat dengan magnitudo sebesar 0.124 mol/kg sedangkan konsentrasi adsorpsi absolut terendah berada di tepi dengan magnitudo sebesar 0.0911 mol/kg. Simulasi unsteady di penampang Fin pada saat kondisi inisiasi awal saat t = 125 detik, adsorpsi absolut dengan konsentrasi tertinggi berada di kuantitas 101 mol/kg pada bagian tepi sedangkan konsentrasi terendah berada di kuantitas 0,739 mol/kg pada bagian pusat. Pada saat t = 700 detik, konsentrasi adsorpsi absolut tertinggi berada di pusat dengan magnitudo sebesar 107 mol/kg sedangkan konsentrasi adsorpsi absolut terendah berada di tepi dengan magnitudo sebesar 79,4 mol/kg. Simulasi unsteady pada potongan 3D menunjukkan bahwa kontur yang ditampilkan tidak simetris yang diakibatkan karena adanya instability pada saat simulasi yang syarat dengan mekanisme trial error. Nilai kapasitas adsorpsi tertinggi mempunyai magnitudo 1 mol/kg sedangkan yang terendah berada di dalam tube dengan magnitudo 0 mol/kg. Selain itu, energi total, entropi, dan karakterisasi dari adsorbat dan adsorber bersifat tetap selama waktu simulasi terkait.

This paper builds an adsorption model in fin tube adsorbent bed. The CFD model is based on the mass, momentum, and energy conservation equations of the adsorption bed system formed of fin, tube, and adsorber. The simplification method of the simulation is made within two fins, one tube, high water temperature as the adsorbate and full compacted silica gel as the adsorber. The simulation is also implemented using a finite volume method through the computational fluid dynamics software Fluent. User defined functions UDFs hooked in Fluent software are given to set the boundary conditions or modify the mass and energy conservation equations. The result shows the contour profile of adsorption process at unsteady condition. First simulation is made at the whole adsorbent bed area, whereas at 25 seconds the highest absolute adsorption rate is achieved with the magnitude of 0,0846 mol kg at the outer surface, while the lowest rate is achieved with the magnitude of 0,0065 mol kg at the center. On the other hand, after 525 seconds, the highest absolute adsorption rate is achieved with the magnitude of 0,124 mol kg at center, while the lowest rate is achieved with the magnitude of 0,0911 mol kg at the outer surface. Then the second simulation is made at the surface area of fin, whereas at 125 seconds the highest absolute adsorption rate is achieved with the magnitude of 101 mol kg at the outer surface, while the lowest rate is achieved with the magnitude of 0,739 mol kg at the center. On the other hand, after 700 seconds, the highest absolute adsorption rate is achieved with the magnitude of 107 mol kg at center, while the lowest rate is achieved with the magnitude of 79,4 mol kg at the outer surface. Last simulation is made within 3D geometrical model in which the highest adsorption rate is achieved with the magnitude of 1 mol kg while the lowest is 0 mol kg. Besides, the total energy, entrophy, and the properties of adsorbate and adsorber are constant in related period of time."
Depok: Universitas Indonesia, 2016
S63565
UI - Skripsi Membership  Universitas Indonesia Library
cover
Tegar Habib
"Cooling Tower merupakan salah satu komponen penting bersama dengan mesin lainnya di suatu industri yang berfungsi untuk menurunkan temperature air. Cooling Tower sistem terbuka menggunakan air sebagai media pertukaran panas. Air yang terus bersirkulasi dapat menyebabkan kerak, korosi, dan lumut karena kualitas air menurun sehingga proses pertukaran panas di cooling tower tidak optimal. Umumnya perawatan cooling tower pada industri menggunakan bahan kimia, namun hal tersebut dianggap belum efektif. Langkah alternatif dalam menjaga kualitas air di cooling tower adalah dengan menggunakan ozon. Flowrate, temperature inlet, dan jumlah ozon terlarut yang diinjeksikan tentu berpengaruh pada cooling tower, terutama kualitas air. Tujuan dari penelitian ini adalah untuk mengetahui pengaruh temperature inlet yang divariasikan terhadap kualitas air, efektivitas cooling tower dan penghematan air. Metode yang digunakan dalam penelitian ini adalah eksperimen kuantitatif. Penilitian ini menggunakan miniatur cooling tower dengan sistem terbuka berukuran (70 x 42,5 x 53) cm. Kualitas air dari cooling tower sistem terbuka ditentukan dengan melakukan pengukuran menggunakan alat uji dan melakukan pemeriksaan laboratorium. Data yang dicatat dari penelitian ini adalah Electric Conductivity, Total Dissolved Solid (TDS), pH, alkalinitas, Ca dan Mg Hardness, Na, dan Cl, serta Range dan Approach. Data tersebut akan digunakan untuk mencari nilai Losses, Practical Ozone Scaling Index (POSI), memprediksi nilai Maximum Cycle dan Maximum Cycle of Concentration, menghitung nilai Blowdown Rate dan Make up Water yang dibutuhkan dan menghitung persentase Efektivitas Cooling Tower. Hasil yang diperoleh dari penelitian ini menunjukan bahwa temperature inlet 30? merupakan temperature inlet yang paling optimal. Ketika temperature inlet 30?, jumlah volume air blowdown dapat menurun 60,94% dan jumlah kebutuhan make up water dapat menurun 36,76%.

Cooling Tower is an important component along with other machines in an industry that functions to reduce water temperature. Open system cooling towers use water as a heat exchange medium. Water that continues to circulate can cause scale, corrosion, and moss because the quality of the water decreases so that the heat exchange process in the cooling tower is not optimal. Generally, cooling tower maintenance in industry uses chemicals, but this is considered ineffective. An alternative step in maintaining water quality in cooling towers is to use ozone. Flowrate, inlet temperature, and the amount of dissolved ozone injected certainly affect the cooling tower, especially water quality. The purpose of this study was to determine the effect of varied inlet temperature on water quality, cooling tower effectiveness and water savings. The method used in this study is a quantitative experiment. This research uses a miniature cooling tower with an open system measuring (70 x 42.5 x 53) cm. Water quality from an open system cooling tower is determined by measuring using a test kit and conducting laboratory tests. Data recorded from this study are Electric Conductivity, Total Dissolved Solid (TDS), pH, alkalinity, Ca and Mg Hardness, Na and Cl, as well as Range and Approach. The data will be used to find Losses values, Practical Ozone Scaling Index (POSI), predict Maximum Cycle and Maximum Cycle of Concentration values, calculate the required Blowdown Rate and Make up Water values and calculate the percentage of Cooling Tower Effectiveness. The results obtained from this study indicate that the inlet temperature of 30? is the most optimal inlet temperature. When the inlet temperature is 30?, the amount of blowdown water volume can decrease by 60.94% and the amount of make-up water needed can decrease by 36.76%."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Maskur
"Vortex tube adalah sebuah alat pendingin tanpa refrigerant dalam proses kerjanya. Vortex tube telah banyak dlgunakan dl dunia industri untuk mengatasi barbagai masalah spot cooling karena relatif murah dan sederhana. Penelltian ini bertujuan untuk mengetahui pengaruh dari perubahan diameter inlet pada vortex tube pada berbagai variasi tekanan udara dari kompresor.
Pengujian dilakukan dengan menggunakan vortex tube proto x-1 F TUl dengan variasi lntet 1 mm dan 0,7 mm. Untuk besar tekanan udara masuk dlpakai empat variasi tekanan yaltu 5 bar; 6 ban 7 bag dan 8 bar: Parameter performa yang digunakan adalah penurunan temperatur dan kapasltas refrierasl yang dihasltkan oleh vortex tube.
Dari pengujian yang dilakukan pada semua variasi tekanan udara masuk diperoleh hasll untuk vortex tube dengan diameter inlet 1 mm menunjukan klnesjia yang lebih balk dibanding dengan diameter inlet 0,7 mm.
Perbedaan performa yang cukup signifikan ini karena pada diameter inlet yang Iebih besar diperoleh udara masuk yang juga besan Hal ini membuat performanya juga lebih maksimal."
Depok: Fakultas Teknik Universitas Indonesia, 2002
S37679
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Indra Siswantara
"Vortex tube adalah sebuah alat pendingin tanpa refrigerant dafam proses kerjanya Vortex tube telah banyak digunakan di dunia induslri Ulttuk mengarasi berbagai masalah spot cooling karena relatif murah dan sederhana. Penelitian ini bertujuan untuk mengetahui pengaruh dari perubahan diameter inlet pada vortex tube pada berbagal variasi tekanan udara dari kompressor.
Pengujian dilakukan dengan menggunakan vortex tube proto x-1 FTUI dengan variasi inlet 1 mm dan 0,7 mm untuk besar tekanan udara masuk dipakai empat variasi tekanan yaitu 5 bar, 6 bar, 7 bar, dan 8 bar. Parameter performa yang digunakan adalah penurunan temperatur dan kapasitas refrijerasi yang dihasilkan oleh vortex tube.
Dari pengujian yang dilakukan pada semua variasi tekanan udara masuk diperoleh hasil uniuk vortex tube dengan diameter inlet 1 mm menunjukkan kinerja yang lebih baik dibanding dengan diameter inlet 0,7 mm.
Inlet Kapasitas Refrijerasi Tempratur drop 1 mm 52.324 J/s 18.9℃
0.7 mm 21.398 J/s 12.8℃
Perbedaan performa yang cukup signifikan ini karena diameter pada inlet yang lebih besar diperoleh udara masuk yang juga besar. Hal ini membuat performanya juga lebih maksimal."
Depok: Universitas Indonesia, 2002
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library