Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 37193 dokumen yang sesuai dengan query
cover
Budihardjo
"Cooling towers are required in building HVAC systems that use water as the cooling condenser fluid. Cooling towers used in this study are of the forced draft, counter flow, indirect/closed evaporative type. This study sought to demonstrate the performance characteristics of a closed system cooling tower by its effectiveness value, Number of Transfer Units (NTU), cooling capacity, and overall heat transfer and mass coefficient of the cooling tower. Experiments were performed on a heat exchanger coil intercrossed with ? inch diameter intersections on parallel lines. Results of the experiment were then compared with the heat and mass transfer correlations taken from previous studies, and also combined with Computational Fluid Dynamics (CFD) simulations to examine the physical processes that occur in the cooling towers. All the experimental results, theoretical calculations and CFD simulations used variations of warm water mass, cold air, and water spray to present a clear description of the performance characteristics of a closed system cooling tower. The results of this study have shown that an increase in the amount of water spray mass flow causes an increase in the effectiveness value, heat transfer and overall mass transfer, as well as the cooling capacity of the cooling tower. The waste heat typically utilizes up to 80% of latent evaporation heat, and 20% of sensible air heat; however, waste heat in the closed system cooling tower utilizes 100% of latent evaporation heat. The mass transfer coefficient rate tends to be stable for a small mass of water spray."
Depok: Faculty of Engineering, Universitas Indonesia, 2015
UI-IJTECH 6:3 (2015)
Artikel Jurnal  Universitas Indonesia Library
cover
Muhammad Abdullah Hamidi
"Menara pendingin dibutuhkan dalam sistem tata udara pada gedung sebagai pendingin air kondenser. Menara pendingin yang digunakan pada penelitian ini bertipe forced draft - counter flow – indirect/ closed evaporative cooling tower. Penelitian ini berusaha untuk menunjukkan karakteristik performa menara pendingin sistem tertutup berupa nilai efektivitas, NTU (Number of Transfer Unit), kapasitas pendinginan, dan koefisien perpindahan kalor dan massa keseluruhan dari menara pendingin. Eksperimen dilakukan pada penukar kalor berupa koil dengan susunan bersilangan dengan diameter 3/8 inchi, yang memiliki jalur parallel.
Hasil eksperimen kemudian dibandingkan dengan korelasi perpindahan kalor dan massa dasar yang ada pada textbook, juga dipadukan dengan simulasi CFD untuk menginvestigasi proses fisik yang terjadi di dalam kolom menara pendingin. Baik eksperimen, perhitungan teoritis, dan simulasi CFD, divariasikan dengan nilai laju massa air hangat, udara dingin, dan air semprot yang berbeda untuk memberikan deskripsi yang jelas tentang karakteristik performa dari menara pendingin sistem tertutup.

Cooling towers are needed in a HVAC sistem in buildings to reject heat from cooling water of a condenser. The type of cooling tower used in this research is forced draft - counter flow – indirect/ closed evaporative cooling tower. This research try to show the performance characteristics of Closed Circuit Cooling Tower (CWCT), specifically the effectiveness value, NTU (Number of Transfer Unit), cooling capacity, and overall coefficient of heat and mass transfers of CWCT. Experiment doing in heat exchanger coils (tube bundle) with stagerred line and 3/8 inch diameter with multipath (parallel path).
The result of experiments compared with basic heat and mass transfer correlations in textbook, and combined with CFD simulation to investigate physical process that occurred in CWCT column. Neither the experiments, theoretical calculations, and CFD simulations, are variated with different mass flow of warm water, cold air, and spray water, to describe the performace characteristics of CWCT.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S53361
UI - Skripsi Membership  Universitas Indonesia Library
cover
R. BG. Hudy Prabowo Edyson
"Air bersih dikonsumsi dalam jumlah banyak sebagai media penghantar panas di pabrik pemurnian minyak kelapa sawit, terutama pada menara pendingin. Program konservasi air bersih dapat dilakukan dengan cara mengurangi jumlah air blowdown menara pendingin. Namun, pengurangan tersebut menyebabkan perubahan karakteristiknya. Penelitian ini bertujuan untuk menganalisis pengaruh program konservasi air bersih pada karakteristik air blowdown menara pendingin, menganalisis perbedaan beban pencemaran air limbah pada outlet IPAL dan biaya pemakaian air bersih dengan diadakannya program tersebut, menganalisis pengaruh tingkat pengetahuan pada sikap karyawan dalam program tersebut. Eksperimen dilakukan dengan mengurangi debit air blowdown menara pendingin dari 60 M3/hari hingga 0 M3/hari. Kuesioner digunakan untuk menganalisis tingkat pengetahuan dan sikap karyawan. Hasil penelitian menunjukkan program konservasi dapat dilakukan dengan mengurangi jumlah air blowdown menara pendingin hingga cycle of concentrationnya mencapai nilai 4,4. Karakteristik air blowdown akan semakin pekat dengan berkurangnya debit air blowdown. Berkurangnya debit air blowdown menjadi 30 M3/hari untuk dua menara pendingin akan mengurangi biaya pemakaian air bersih dan rata-rata beban pencemaran air limbah outlet IPAL untuk parameter COD sebesar 8,20% dengan sistem kontinu. Hubungan tingkat pengetahuan dan sikap karyawan dalam program konservasi air bersih ini bersifat positif dan kuat, sedangkan pengaruh tingkat pengetahuan pada sikap karyawan bersifat sedang.

A large amount of clean water used in heat transfer system in palm oil refinery plant, especially in cooling tower device. Clean water conservation program should be conducted by reducing cooling tower blowdown water. However, reducing blowdown water will impact on changes in its characterisctics. This research examines the impact of clean water conservation program to blowdown water characteristics, analyse the difference of wastewater pollution load and clean water cost thorough that program implementation, analyse an influence of employees  knowledge level on employees attitude in that program. Experiment was conducted by reducing cooling tower blowdown water debit from 60 M3/day to 0 M3/day. Questionnaire was used to analyse employees knowledge level and attitude. The result shows that conservation program can be applied by reducing blowdown water until cycle of concentration has the value of 4,4. Blowdown water characteristics become more concentrated by reducing cooling tower blowdown water. Reducing blowdown water of two cooling towers to 30 M3/day will reduce clean water cost and wastewater COD pollution load by 8,20 with continue treatment. Level of knowledges and attitude correlation in this program is strong and positive, whereas level of knowledges influence employees attitude in clean water conservation program on moderate level."
Jakarta: Sekolah Kajian Stratejik dan Global Kajian Ilmu Lingkungan, 2019
T52341
UI - Tesis Membership  Universitas Indonesia Library
cover
Muhammad Hafil Nugraha
"Dalam suatu siklus kondenser perpendingin air, air pendingin kondenser menyerap panas dari fenomena kondensasi refrijeran. Air pendingin tersebut perlu didinginkan kembali menggunakan sistem menara pendingin.Terdapat dua jenis menara pendingin evaporatif yakni sistem terbuka dan tertutup. Dari kedua jenis menara pendingin ini terdapat perbedaan unjuk kerja yang perlu ditinjau. Unjuk kerja suatu menara pendingin bergantung pada nilai efektifitas, bilangan NTU, dan kapasitas pendinginan yang dihasilkan.Untuk menara pendingin terbuka eksperimen dilakukan dengan menggunakan paking di dalam menara dan tidak menggunakan paking (non-paking) pada menara pendingin tertutup digunakan penukar kalor berupa koil dengan susunan bersilangan dengan diameter 3/8 inchi, yang memiliki jalur parallel.Peninjauan terhadap perbedaan unjuk kerja antara dua jenis menara pendingin perlu dilakukan dengan membandingkan hasil dari percobaan.

In water cooled condenser, heat from the process of refrigerant condensation absorbed by cooling water. Cooling tower used to dissipate heat from water cooled refrigeration. There are two basic types of evaporative cooling devices. The first of these, the direct contact or open cooling tower. The second is indirect contact or closed-circuit cooling tower.The comparison perfomance between type of cooling tower must be known. Perfomance of cooling tower depends from the effectiveness, Number Transfer Unit (NTU), and cooling capacity.Experiment in open cooling tower doing with packing inside and non-packing. In closed cooling tower used the heat exchanger coils (tube bundle) with stagerred line and 3/8 inch diameter with multipath (parallel path)."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S53338
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aufalia Rosyida Maula
"Di negara tropis, suhu dan kelembapan tinggi menjadi salah satu kendala yang perlu ditangain dalam perancangan rumah. Sehingga banyak perumahan di perkotaan Indonesia yang bergantung pada pengudaraan buatan atau air-conditioning (AC). Sementara itu, dengan perkembangan pengetahuan, maka berkembang juga berbagai macam teknik pemanfaatan udara alami. Konsep passive cooling berpotensi mengurangi kebutuhan konsumsi energi listrik. Pengetahuan terkait sifat dasar pergerakan aliran udara serta strategi menurunkan suhu udara dapat mengoptimalkan passive cooling sehingga suhu udara tidak bergantung pada alat pendingin mekanis. Tujuan dari passive cooling adalah untuk mencapai kenyamanan termal dengan konsumsi listrik minim. Tulisan ini mendalami hal-hal yang perlu diperhatikan dalam perancangan sistem passive cooling yaitu iklim dan perubahan iklim, serta pengaruhnya pada kenyamanan termal manusia. Didapatkan bahwa pengetahuan terkait dasar pergerakan udara serta strategi passive coolinglainnya dapat mendukung tercapainya kenyamanan termal penghuni di suatu rumah.

In tropical countries, high temperatures and humidity are a few of the obstacles that need to be overcome when designing a home. Thus, many urban housings in Indonesia are dependent on artificial air-conditioning (AC). However, various kinds of natural air utilization techniques have been and are being developed. The concept of passive cooling has the potential to reduce the need for mass electricity consumption. Knowledge regarding the nature of air flow movements and strategies to reduce air temperature can optimize passive cooling so that a comfortable air temperature is not dependant on mechanical cooling devices. The purpose of passive cooling itself is to achieve thermal comfort with minimal electricity consumption. This paper explores the things that need to be considered in designing passive cooling systems, namely climate and climate change, and their effects on human thermal comfort. It was found that a thorough understanding of basic principles of air movement and other passive cooling strategies can support the achievement of residents' thermal comfort in a house."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ibnu Thooriq Ramadhan
"Menara pendingin adalah suatu unit yang membantu proses pembuangan kalor. Maka, efektivitas thermal adalah sebuah variabel yang vital untuk performa dari menara pendingin. Presipitasi kerak dapat menjadi faktor yang sangat mengganggu efektivitas thermal dari unit penukar kalor karena sifat natural nya yang mempunyai resistansi thermal yang tinggi. Proses ozonasi diharapkan dapat menurunkan potensi presipitasi kerak yang mana meningkatkan performa thermal menara pendingin. Air pendingin pada menara disirkulasikan lalu diaplikasikan dengan ozon dan sinar UV. Penelitian ini bertujuan untuk mengetahui karakteristik efek ozonasi terhadap total resistansi thermal fouling dari menara pendingin forced draft - counter flow - sistem tertutup serta kualitas air sirkulasi melalui metode Practical Ozone Scaling Index dan Langelier Saturation Index. Metode yang digunakan dalam mengetahui kualitas air menara pendingin sistem tertutup adalah dengan melakukan uji laboratorium seperti AAS, Titrimetric, Gravimetrik, dan Spectrophotometric. Hasil yang didapat dari penelitian ini menunjukkan bahwa dengan aplikasi ozon, total resistansi thermal menara pendingin sistem tertutup menurun sebesar 7 x10-6 m2K/W. Ozon juga dapat meningkatkan kualitas air sirkulasi menara pendingin sistem tertutup.

Cooling tower is a unit that helps heat dissipation process. Thus, thermal effectiveness is a vital variable for performance of the cooling tower. Scale precipitation can be a very disturbing factor to the thermal effectiveness of the heat exchange unit due to its natural properties which have high thermal resistance. The ozonation process is expected to decrease the potential of precipitation of the scale which improves the cooling tower thermal performance. The cooling water is circulated from the tower, then applied by ozone and UV ray. This study aims to determine the characteristics of the effects of ozonation on the overall thermal fouling resistance of forced draft type ndash counter flow closed system cooling towers and the quality of water circulation through Practical Ozone Scaling Index and Langelier Saturation Index methods. Water quality of closed system cooling towers is determined by conducting laboratory tests such as AAS, Titrimetric, Gravimetric, and Spectrophotometric. The results obtained from this study indicate that by the presence of ozone, the overall thermal tower resistance of the closed system cooling towers reduced by 7 x10 6 m2K W. Ozone can also improve the water quality of closed system cooling towers."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rifqi Miftah Majduddin
"Menara Pendingin adalah suatu unit yang dapat membantu melakukan perpindahan kalor dimana kalor tersebut sudah tidak dibutuhkan lagi. Dalam operasi menara pendingin, ada beberapa faktor yang dapat dijadikan tinjauan dalam mengukur performa dari menara pendingin. Banyaknya bakteri di dalam menara pendingin menyebabkan presipitasi kerak yang dapat mengganggu efektivitas thermal dari menara pendingin dikarenakan kerak-kerak tersebut akan menghambat laju perpindahan kalor karena mempunyai resistansi thermal yang tinggi. Ada beberapa cara untuk mengurangi laju pertumbuhan dari kerak, salah satunya adalah ozonasi. Ozonasi adalah injeksi ozon pada air pendingin menara pendingin untuk mengurangi potensi dari presipitasi kerak yang akan meningkatkan performa dari menara pendingin.
Penelitian ini bertujuan untuk mengetahui karakteristik efek ozonasi terharap performa dari menara pendingin dan kualitas air pendingin pada menara pendingin sistem tertutup. Metode yang digunakan untuk menguji kualitas air adalah pengujian dengan alat ukur yang dicelupkan setiap harinya dan uji laboratorium seperti AAS, Titrimetric, Gravimetrik, dan Spectrophotometric.
Hasil yang didapat pada penelitian ini adalah karakterisitik laju performa setiap harinya dan laju kualitas air setiap harinya maupun saat sebelum dan sesudah ozonasi. Hasil dari nilai efektivitas yang didapat adalah 0.12 % untuk nilai terkecil dan 8.74 % untuk nilai terbesar. Ozonasi terbukti dapat meningkatkan kualitas air menara pendingin tetapi belum terbukti dapat meningkatkan performa atau efektivitas menara pendingin untuk jangka waktu ozonasi selama 15 hari.

Cooling tower is a unit or system that used for heat transfer process where the heat is not useful anymore. There is several factor in the cooling tower operations that can observed for cooling tower performance. The large amount of bacteria on cooling tower become potential of scale precipitation that can decrease the cooling tower thermal effectivity because of the scale will act as inhibitor for heat transfer rate since the scale has high value of thermal resistance. There are several method for reducing scale precipitation growth rate, one of them is ozonation or ozone injection method. The ozone will injected to the cooling water to reduce the scale precipitation growth rate that can decreases the cooling tower performance.
This research intends to find the characteristic of ozonation effect from cooling tower performance and water quality. The method for water quality checking are AAS method, Titrimetric, Gravimetric, and Spectrophotometric.
The output of this research are characteristic of cooling tower performance each day and rate of water quality before and after ozonation and each day. The effectiveness value results obtained in this research was 0.12 % for the lowest value and 8.74 % for the highest value. Ozonation has been proven to improve water quality rate of cooling towers but has not been proven to improve the performance or effectiveness of cooling towers for an ozonation period of 15 days.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Randa Kelvin
"Dalam dunia industri, menara pendingin merupakan salah satu peralatan yang digunakan sebagai sirkulasi air pendingin dalam berbagai industri. Penanggulangan kualitas air pendingin yang kurang memadai dapat menyebabkan mesin seperti unit heat exchanger akan mengalami korosi atau terbentuk kerak yang menyebabkan keefektifitasan menara pendingin berkurang. Penelitian ini bertujuan untuk mengetahui pegaruh penggunaan ozon terhadap efektifitas kinerja dan kualitas air menara pendingin sistem tertutup bertipe forced draft ndash; cross flow ndash; indirect/closed. Metode yang digunakan dalam penelitian ini adalah menyuntikkan ozon 3gr/hr ke dalam basin menara pendingin sistem tertutup dan melakukan uji laboratorium seperti AAS, Titrimetric, Gravimetrik, dan Spectrophotometric.
Hasil penelitian ini adalah kefektifitasan dari menara pendingin sistem tertutup setelah disuntikkan ozon memiliki nilai terkecil 6.6 dan nilai terbesar 26.7 Nilai Evaporation Loss nilai terkecil 0.03 m /h dan terbesar 0.119 m /h. Ozon terbukti mempengaruhi kualitas air pada basin menara pendingin sistem tertutup tetapi ozon belum dapat dikatakan mempengaruhi performa dari menara pendingin sistem tertutup dalam jangka 10 hari.

In the industrial world, cooling towers are one of the equipments used as cooling water circulation in various industries. Inadequate cooling water may cause the machine such as a heat exchanger unit becomes corrosion or crust formation which causes the cooling tower less effective. This study aims to determine the effect of using ozone based on performance and quality of the cooling tower with type forced draft cross flow indirect closed. 3g hr ozone is injected into closed system cooling tower as a method and conducted laboratory tests such as AAS, Titrimetric, Gravimetric, and Spectrophotometric.
As the result, the effectiveness of closed system cooling tower after ozone injection has the smallest value of 6.6 and the largest value of 26.7 . Evaporation Loss value of smallest value 0.03 m h and largest 0.119 m h. The role of ozone in closed system cooling towers affects water quality in the cooling system cooling basin but ozone does not affect the performance of the closed system cooling tower within 10 days.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Okti Giffari, auhtor
"Menara pendingin atau Cooling Tower merupakan salah satu komponen penting pada suatu pembangkit. Pada PLTP, menara pendingin berguna untuk menurunkan suhu fluida cair hasil dari perubahan fase gas-cair pada proses vakum di kondensor. Sehingga fluida cair dapat mebuang kalor panasnya ke udara luar dan dapat dipakai lagi untuk proses vakum pada kondensor. peningkatan vakum kondensor membuat hasil output listrik pada turbin semakin optimal. Oleh karena itu proses pendinginan fluida pada Menara Pendingin sangat penting. Akan tetapi proses pendinginan pada menara pendingin sangat bergantung dengan kondisi lingkungan udara lokasi pembangkit.
Pada skripsi ini penulis membuat analisis kinerja dari Menara Pendingin dengan jenis Crossflow inducted draft Cooling Tower dengan mengevaluasi hasil yang didapat dari data Control room dan data desain awal pembangkit. Dengan analisis kerja ini didapat bahwa temperatur wet bulb dari udara masuk cooling tower mempengaruhi nilai dari temperatur hasil pendinginan menara pendingin pada basin yang juga mempengaruhi kondisi tekanan vakum pada kondensor dan menyebabkan perubahan pada hasil beban generator.

Cooling tower is one of the important components of geothermal power plant. Cool-ing tower useful for lowering the temperature of liquid fluid result of the gas ?fluid changes phase in the proces of vacuum in condenser. So that the hot liquid fluid can transfer calorific heat to the outdoor air and the liquid result can be used again for the vacuum in the condenser. Condenser vacuum increase make the electrical out-put of the turbine further optimized. Therefore, the process of cooling fluid in the cooling tower is very important. But the cooling process in the cooling tower is very dependent on the environmental air plant site.
In this thesis, the author makes the analysis of the performance of the Crossflow inducted draft Cooling Tower to eval-uate the results obtained from the data Control room and plant the initial design data. The result found that the wet bulb temperature of the inlet air cooling tower affect the value of the temperature of cooling results in the cooling tower basin that also affect the condition of vacuum pressure in the condenser and cause changes in the results of the load generator
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64901
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rizqi
"Tingkat efisiensi penggunaan energi di Indonesia masih rendah, hal ini tentu saja menjadi masalah yang serius. Oleh karena itu harus ada upaya konservasi energi. Teknologi sistem CCHP Combined Cooling, Heating and Power pada bangunan hotel merupakan salah satu jawaban dari tantangan tersebut yang dibahas dalam penelitian ini.
Dalam penelitian ini dilakukan perbandingan antara pemakaian energi pada sistem eksisting listrik dari jaringan PLN/konvensional dengan sistem CCHP berdasarkan analisis teknis dan ekonomi pada hotel referensi. Selain itu juga akan dianalisis mengenai skema pengaplikasian sistem CCHP, yaitu sistem CCHP dibangun sendiri oleh pihak hotel atau melakukan kerjasama dengan ESCO melalui model bisnis BOT selama 10 tahun. Sistem CCHP disimulasikan dengan perangkat lunak berbasis analisis termodinamika dan konservasi energi dengan dasar desain FEL Following the Electric Load.
Hasilnya sistem CCHP mampu menghemat konsumsi energi primer sebesar 45,98 dibandingkan sistem eksisting. Sehingga akan terjadi penghematan biaya pengeluaran energi oleh pihak hotel. Pengaplikasian sistem CCHP pada hotel referensi dengan pembangunan sendiri akan memberikan keuntungan secara keekonomian dengan nilai NPV Rp 8.333.856.481, IRR 25,93 dan payback period 9 tahun. Sementara jika pembangunan dilakukan melalui skema kerjasama BOT dengan ESCO selama 10 tahun, dengan tarif energi flat sebesar Rp 1.402,75/kWh, maka akan mendapatkan keuntungan secara keekonomian dengan nilai NPV Rp 15.993.166.682, IRR 34,89 dan payback period 7 tahun. Emisi karbon dioksida CO2 dan nitrogen oksida NOx yang dihasilkan oleh sistem CCHP lebih sedikit 39 untuk emisi CO2 dan 75 untuk emisi NOx jika dibandingkan dengan sistem eksisting.

Level of efficiency of energy use in Indonesia is still low, it is of course become a serious problem. Therefore, there must be energy conservation efforts. CCHP Combined Cooling, Heating and Power system technology is one of the answers to these challenges that is discussed here.
In this study a comparison between the energy consumption in existing system from PLN electricity network conventional and CCHP system based on technical and economic analysis at the reference hotel. In addition, the scheme will also be analyzed regarding the application of CCHP system, by developing its own system of CCHP by the hotel or cooperating with the ESCO through BOT business model for 10 years. CCHP system is simulated with software based analysis of thermodynamics and energy conservation with the basic design of FEL Following the Electric Load.
As a result primary energy consumption saving from CCHP system is 45,98 compared to the existing system. So that there will be cost savings in energy expenditure by the hotel. CCHP system application in a reference hotel with its own development will provide the economic benefits with a value of Rp 8.333.856.481 NPV, IRR 25,93, and a payback period of 9 years. Meanwhile, if the construction was done through BOT scheme with ESCO cooperation for 10 years, with flat energy rate of Rp 1.402,75 kWh, then it will get the economic benefits with a value of Rp 15.993.166.682 NPV, IRR 34,89 and a payback period of 7 years. Emissions of carbon dioxide CO2 and nitrogen oxides NOx generated by CCHP system less 39 of CO2 emissions and 75 for NOx emissions when compared with existing systems."
Depok: Fakultas Teknik Universitas Indonesia, 2016
T47533
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>