Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 121333 dokumen yang sesuai dengan query
cover
Ahmad Saptadi
"Latar Belakang: Komplikasi serius yang menyertai tindakan odontektomi adalah cedera nervus alveolaris inferior. Hal penting untuk mengetahui secara tepat posisi gigi molar tiga mandibula impaksi terhadap kanalis mandibula, dengan pemeriksaan radiologi baik 2 dimensi (radiograf panoramik) maupun 3 dimensi (CBCT Scan). Tujuan: Mengevaluasi posisi gigi molar tiga mandibula impaksi yang memiliki kedekatan terhadap kanalis mandibula pada radiograf panoramik berdasarkan  CBCT Scan. Metode: Penelitian deskriptif analitik menggunakan data radiograf Panoramik dan DICOM File CBCT Scan yang memenuhi kriteria inklusi dari  beberapa fasilitas kesehatan yang ada di Jakarta dari bulan November 2010 sampai Desember 2017. Pemeriksaan dilakukan dengan menggunakan komputer yang dilengkapi sistem operasi Macintosh atau Windows serta Planmeca  Romexis Ò imaging software viewer. Analisa data menggunakan SPSS 22 dan uji Chi-Square. Hasil: 48 pasien dengan 61 sampel  memenuhi kriteria inklusi. Kategori posisi berdasarkan radiograf panoramik paling banyak ditemukan adalah peningkatan radiolusensi. Kategori posisi berdasarkan CBCT Scan yang paling banyak ditemukan adalah posisi inferior. Berdasarkan uji statistik ditemukan terdapat perbedaan proporsi yang bermakna (p<0.05) antara kategori Radiograf Panoramik dan kategori lingual-bukal-inferior pada CBCT Scan. Kesimpulan: Penelitian ini dapat dijadikan acuan untuk mengevaluasi posisi gigi molar tiga mandibula terhadap kanalis mandibula dalam memperkirakan resiko terjadinya komplikasi cedera nervus alveolaris inferior selama tindakan odontektomi.

Introduction:The serious complication associated odontectomy is inferior alveolar nerve (IAN) injury.  It is essential to investigate accurately the position of impacted mandibular third molars improved the mandibular canal is by radiological examination in nor 2-dimensional (radiograph panoramic) and 3-dimensional (CBCT Scan). Obejctive: The aim of this study is to evaluate the positions of impacted mandibular third molars in which have proximity the mandibular canal on a panoramic radiography based on CBCT Scan. Materials and Methods: This study use descriptive analytic with panoramic radiograph and DICOM File data CBCT Scan that qualified inclusion criteria from several healthcare facilites in Jakarta from November 2010 until  December 2017. The research is done using a computer equipped with Macintosh or Windows operating system and Planmeca Romexis Ò imaging software viewer. Data analysis using SPSS 22 and Chi-Square test. Result: We got 48 patient with 61 teeth sample that qualified inclusion criteria. The most common found position we got from panoramic radiograph is increasing radiolucency. While, from CBCT scan we got the inferior position as the most common found position. Based on statistical test of result between Panoramic Radiograph and CBCT Scan we found that there is proportionally significance (p< 0.05) among category of panoramic radiograph and category of lingual-buccal-inferior on CBCT scan. Conclusion: This study can be used as a reference to evaluate the positions of mandibular third molars against the mandibular canal in prediction the risk of complications of inferior alveolar nerve injury during odontectomy.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Bambang Tri Susilo
"Latar Belakang : Tebal ramus mandibula merupakan salah satu faktor penting yang harus diperhatikan saat melakukan Bilateral Sagittal Split Osteotomy BSSO . Fraktur unvaforable atau bad split dapat terjadi saat melakukan BSSO apabila ramus mandibula tipis. Data antropometri tentang tebal ramus mandibula masih belum banyak diteliti. Data antropometri tentang tebal ramus mandibula bisa dipakai sebagai acuan jika akan melakukan BSSO.
Tujuan : untuk mengetahui tebal ramus mandibula berdasarkan CBCT Scan sebagai acuan tindakan BSSO.
Metode : Subjek penelitian ini terdiri dari 61 sampel data DICOM CBCT Scan yang kemudian dilakukan reorientasi dalam 3 bidang dan dilakukan pengukuran pada tebal ramus mandibula menggunakan software Osirix LXIV.
Hasil : Didapatkan rata-rata tebal ramus mandibula pada laki-laki 8.049 1.205 mm dan pada perempuan 8.463 1.358 mm. Pada kelompok usia 18-30 tahun didapatkan rata-rata tebal ramus mandibula 8.087 1.29 mm, kelompok usia 31-40 tahun 8.176 1.49 mm, kelompok usia 41-50 tahun 8.742 1.04 mm.
Kesimpulan : Berdasarkan CBCT Scan, secara statistik tidak terdapat perbedaan yang bermakna tebal ramus mandibula pada jenis kelamin laki-laki dan perempuan maupun pada kelompok usia.

Backgorund: Ramus mandibular thickness is one of the most important factor that has to be concerned when performing Bilateral Sagittal Split Osteotomy BSSO . Unfavorable fracture or bad split could happen when performing BSSO if the ramus mandible thickness is thin. There only a few regarding antropometric data about thickness of mandibular ramus.
Objective: To measure thickness of mandibular ramus based on CBCT Scan as a reference when performing BSSO.
Methods: Subject of this research consist of 61 data sample DICOM CBCT Scan which reoriented in three planes and measuring thickness of the ramus mandible using Osirix LXIV.
Result: Mean thickness of the ramus mandible for male is 8.049 1.205 mm and female 8.463 1.358 mm. In group age of 18 30 mean thickness of the ramus mandible is 8.087 1.29 mm, group age 31 40 is 8.176 1.49 mm, group age 41 50 is 8.742 1.04 mm.
Conclusion: Based on CBCT Scan there are no difference statistically between thickness of ramus mandible in male and female, and group of age.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2017
SP-PDF
UI - Tugas Akhir  Universitas Indonesia Library
cover
Irene Tenriana Kenia
"Dewasa ini, teknologi kedokteran gigi di Indonesia, khususnya di Yogyakarta semakin berkembang dengan sangat pesat. Tindakan medis yang umumnya dilakukan pada kasus impaksi gigi berupa pencabutan terhadap gigi yang impaksi. Sebelum dilakukan pencabutan gigi, pasien akan diminta dokter gigi untuk melakukan pemeriksaan radiografi. Teknologi  radiografi yang saat ini dikenal sebagai pemeriksaan penunjang untuk mendiagnosis impaksi gigi adalah Cone-Beam Computed Tomography dan Panoramik.
Tujuan dari penelitian ini adalah mengetahui efektivitas biaya dari dua fasilitas pemeriksaan penunjang, yaitu CBCT dan Panoramik yang dilakukan di RSGM UMY Yogyakarta. Penelitian ini bersifat non eksperimental menggunakan evaluasi ekonomi model cost effectiveness analysis dengan cohort retrospective. Data sekunder yang digunakan dalam penelitian ini adalah rekam medis, dokumen keuangan, dokumen bagian fix asset, dan dokumen pencatatan ruang radiologi di RSGM UMY dari 1 Januari 2021 hingga 31 Desember 2021.
Penelitian ini menghitung biaya dari setiap aktivitas menggunakan metode Activity Based Costing. Biaya yang dihitung dalam penelitian ini terdiri dari biaya investasi, biaya pemeliharaan, serta biasanya operasional. Biaya tersebut dihitung sesuai dengan aktivitas yaitu di pendaftaran, poli perawat, poli gigi, poli radiologi, dan kasir. Sedangkan output pada penelitian ini terdapat empat indikator yaitu akurasi radiografi, error rateradiograf, dosis radiasi, dan waktu paparan. Efektivitas yang dihitung dari akurasi radiograf kedua pemeriksaan penunjang.
Hasil penelitian memperlihatkan bahwa biaya pemeriksaan CBCT Rp 614.843,4 dan kelompok Panoramik didapatkan hasil yang lebih murah yaitu Rp 333.342,0. Biaya investasi yang memiliki kontribusi adalah biaya investasi di poli gigi yaitu sebesar Rp 89.545,9 baik pada pemeriksaan CBCT maupun Panoramik. Output yang diukur dalam penelitian ini adalah akurasi radiograf, error rate radiograf, dosis radiasi, dan waktu paparan. Namun, untuk mendapatkan nilai efektivitas dilakukan perhitungan akurasi, dimana pada pemeriksaan CBCT didapatkan hasil akurasi sebesar 50% dan persentase akurasi radiografi Panoramik sebesar 90,8%.
Panoramik memiliki efektivitas yang lebih baik dari CBCT dan harga yang lebih rendah. Oleh karena itu, radiografi Panoramik pada penelitian ini mendominasi. Sehingga dapat dikatakan Panoramik lebih cost effective dari CBCT.
CBCT terbukti tidak cost effective karena memiliki biaya yang lebih tinggi namun efektivitasnya tidak lebih baik. Penelitian ini hanya berfokus pada RSGM UMY. Sampel yang terbatas tidak mencerminkan kondisi pelayanan radiografi gigi secara umum di fasilitas kesehatan lain.

Today, dental technology in Indonesia, especially in Yogyakarta, is growing very rapidly. The most common medical procedure for impacted teeth is the extraction of the impacted tooth. Prior to tooth extraction, the patient will be asked by the dentist to perform a radiographic examination. Radiographic technology currently known as a supporting examination for diagnosing impacted teeth is Cone-Beam Computed Tomography and Panoramic.
The purpose of this study was to determine the cost-effectiveness of the two supporting examination facilities, namely CBCT and Panoramic which were carried out at RSGM UMY Yogyakarta. This research is non-experimental using an economic evaluation model of cost-effectiveness analysis with a retrospective cohort. The secondary data used in this study are medical records, financial documents, fixed asset section documents, and radiology room recording documents at RSGM UMY from January 1, 2021 to December 31, 2021.
This study calculates the cost of each activity using the Activity Based Costing method. The costs calculated in this study consist of investment costs, maintenance costs, and usually operational costs. The fee is calculated according to the activities, namely at registration, nursing poly, dental poly, radiology poly, and cashier. While the output in this study there are four indicators, namely radiographic accuracy, radiographic error rate, radiation dose, and exposure time. Effectiveness was calculated from the accuracy of the radiographs of both investigations.
The results showed that the cost of the CBCT examination was Rp. 614,843.4 and the panoramic group got cheaper results, which was Rp. 333,342.0. The investment cost that has a contribution is the investment cost in the dental clinic, which is Rp. 89,545.9 for both CBCT and panoramic examinations. The outputs measured in this study were radiographic accuracy, radiographic error rate, radiation dose, and exposure time. However, to get the effectiveness value, an accuracy calculation is carried out, where the CBCT examination results in an accuracy of 50% and the percentage of Panoramic radiography accuracy of 90.8%.
Panoramic has better effectiveness than CBCT and lower cost. Therefore, panoramic radiography in this study dominates. So it can be said that Panorama is more cost effective than CBCT.
CBCT is proven not to be cost effective because it has a higher cost but its effectiveness is not better. This research only focuses on RSGM UMY. The limited sample does not reflect the general condition of dental radiography services in other health facilities.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Yudwitiawati
"Uji fungsi CBCT perlu dilakukan untuk memastikan performa terbaik pada CBCT. Uji fungsi yang dilakukan pada penelitian in adalah akurasi isocenter,kualitas citra 3D dan 2D dengan menggunakan fantom Ball bearing, Catphan, dan LEEDS. Uji fungsi dilakukan dengan 2 mode yang berbeda yaitu mode service dan clinical yang memiliki resolusi 540 x 540 dan 270 x 270. Pengukuran dengan menggunakan ball bearing dapat melihat pergeseran isocenter pada sumbu x, y, z. Pergeseran terbesar terjadi pada rotasi 0º sebesar 0.23 cm sumbu x 0.02 cm sumbu z. Hasil perbandingan evaluasi citra 3D pada mode service dan clinical menunjukan bahwa CT number keduanya tidak terlalu banyak perbedaan. Resolusi tinggi pada mode service mencapai 8lp/cm sedangkan pada mode clinical resolusi tidak mampu membedakan sama sekali. Uji citra 2D menggunakan tiga jenis fantom LEEDS. Kontras rendah dapat dilihat dan dievaluasi pada LEEDS TOR 18 FG,TOR CDR,dan TO10. Kontras tinggi hanya dapat dilihat pada LEEDS TOR 18 FG dan TOR CDR. Tidak terdapat perbedaan yang signifikan dari hasil evaluasi kontras rendah dan perbedaan signifikan terjadi pada kontras tinggi.dan uji resolusi antara kedua mode. Fantom NORMI 4 juga digunakan pada penelitian ini, dan tidak ada perbedaan hasil dari uji kontras tinggi dan kontras rendah antara NORMI 4 dan LEEDS. Hasil kontras tinggi dari fantom NORMI 4 adalah 4 lp/mm. Oleh karena itu fantom NORMI 4 dapat dijadikan alternatif lain untuk menilai resolusi dan kontras pada citra 2D. Perhitungan CBDIw dengan fantom CTDI berdiameter 16 cm adalah 8.3 mGy. Uji fungsi sebaiknya menggunakan resolusi tertinggi.

Performence test of Cone Beam Computed Tomography (CBCT) must be done to ensure CBCT is on its best performance. The performance test done in this study are isocenter accuracy, 3D and 2D image quality using ball bearing phantom, CATPHAN, LEEDS test object, and Normi. The test was done using 2 different mode wich are service and clinical mode that has resolution of resolution 540 x 540 and 270 x 270. Ball bearing measurements showed that this technique can detect isocenter shift on the axis of x, y, and z. The largest isocenter displcement occurred at 0 º rotation at 0.23 cm x-axis 0.02 cm z-axis. 3D image comparison using service and clinical mode, show that CT Number value are not much different. High contras resolution at service mode is 8 lp/cm but on clinical mode is not able to distinguish at all. 2D image comparison were done using three types LEEDS test object, low contrast can be observed and evaluated on LEEDS TOR 18 FG, TOR CDR, and TO10, high contrast can be bserved on LEEDS 18 FG and TOR CDR. From LEEDS test object there were no significant difference were shown on low contrast comparison and significant difference were shown on high contrast and resolution test. Normi 4 phantom also used on this study, and there were no difference in trend result on high and low contrast between NORMI 4 phantom and LEEDS test object. Result of NORMI 4 measurement high contrast resolution is 4 lp/mm. Therefore Normi 4 can be used as an alternative to asses the image resolution and contrast in 2D images on CBCT. CBDIw calculations with 16 cm diameter CTDI phantom was 8.3 mGy. Performance tests should use the highest resolution.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S46815
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rina Fajarwati
"Latar Belakang: Identifikasi jenis kelamin membutuhkan sarana yang terjangkau dengan realibilitas yang baik, terutama pada kondisi jenazah yang terbakar hebat, rusak, atau terdekomposisi. Sinus maksilaris dan kanalis mandibularis merupakan salah satu struktur yang dapat digunakan untuk prakiraan jenis kelamin. Cone Beam Computed Tomography (CBCT) adalah metode non infasif yang dapat memberikan gambaran struktur anatomis maksilofasial termasuk sinus maksilaris dan kanalis mandibularis dengan resolusi yang tinggi, sehingga untuk kepentingan identifikasi forensik dapat memberikan pengukuran dengan akurasi tinggi. Tujuan: Hasil analisis perbedaan ukuran sinus maksilaris dan posisi kanalis mandibularis diharapkan dapat digunakan untuk prakiraan jenis kelamin. Metode: Membandingkan ukuran sinus maksilaris dan posisi kanalis mandibularis antara jenis kelamin menggunakan CBCT.
Hasil: Perbedaan yang bermakna pada ukuran sinus maksilaris, serta jarak dari kanalis mandibularis ke batas inferior mandibula antara laki-laki dan perempuan.
Kesimpulan: Terdapat perbedaan bermakna pada tinggi, panjang, dan lebar sinus maksilaris antara laki-laki dan perempuan, dengan nilai rerata masing-masing laki-laki dan perempuan sebesar 39.4 ± 4.6 dan 33.9 ± 4.8 pada tinggi, 39.9 ± 3.2 dan 37.4 ± 2.4 pada panjang, serta 31.1 ± 4.6 dan 28.6 ± 3.8 pada lebar sinus maksilaris. Terdapat perbedaan bermakna pada jarak dari kanalis mandibularis ke batas inferior mandibula antara laki-laki dan perempuan, dengan nilai rerata pada laki-laki dan perempuan yaitu sebesar 7.7 ± 1.7 dan 6.8 ± 1.5. Berdasarkan ukuran tinggi dan panjang sinus maksilaris, serta jarak dari kanalis mandibularis ke batas inferior mandibula maka didapatkan rumus P = 1/1+e- [-16.613 + (<0.183 x TSM) + (0.204 x PSM) + (0.260 x JIKM)] untuk prakiraan jenis kelamin, dengan nilai ≥ 0.5 pada laki-laki dan < 0.5 pada perempuan.

Background: Gender identification requires a tool which has high reliability, especially in the conditions of the bodies that are severely burned, damaged, or decomposed. The maxillary sinus and mandibular canal are one of the maxillofacial structure that can be used to identify the gender. Cone Beam Computed Tomography (CBCT) is a non-invasive method which can visualize the anatomical of the maxillofacial structure including the maxillary sinus and mandibular canal with high-resolution so that CBCT can provide better measurements for forensic identification.
Aim: The results of the study can show the differences in maxillary sinus size and mandibular canal position which are expected to be used for gender identification.
Methods: Comparing the maxillary sinus size and mandibular canal position between genders using CBCT.
Result: The maxillary sinus sizes and the distance from the mandibular canal to the inferior border of the mandible between men and women were significantly different.
Summary: There were significant differences in the height, length, and width of the maxillary sinus between men and women, with the mean value of men and women, respectively were 39.4 ± 4.6 mm and 33.9 ± 4.8 mm for height, 39.9 ± 3.2 mm and 37.4 ± 2.4 mm for length, and 31.1 ± 4.6 mm and 28.6 ± 3.8 mm for width of the maxillary sinus. There was a significant difference in the distance from the mandibular canal to the inferior border of the mandible between men and women, with a mean value were 7.7 ± 1.7 mm and 6.8 ± 1.5 mm. Based on the height and length of the maxillary sinus, which exclude the width of the maxillary sinus, and the distance from the mandibular canal to the inferior border of the mandible, the formula for gender estimation was P = 1/1+e- [-16.613 + (0.183 x Height of maxillary sinus) + (0.204 x Length of maxillary sinus) + (0.260 x JIKM). The distance from the mandibular canal to the inferior border of the mandible with male values ≥ 0.5 whereas for women when < 0.5.
"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2019
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Tarigan, Sonak Tioria
"Penelitian ini bertujuan untuk mengevaluasi akurasi perhitungan dosis berdasarkan citra Cone Beam Computed Tomography (CBCT) sebagai adaptive planning. Perencanaan terapi radiasi dilakukan terhadap 3 pasien kanker laring, 7 pasien kanker paru dan 5 pasien kanker prostat dengan menggunakan teknik Intensity Modulated Radiotherapy (IMRT) dan Volumetric Modulated Arc Therapy (VMAT). Perhitungan dosis dilakukan pada TPS Eclipse v13.6 dengan variasi algoritma Analytical Anisotropic Algorithm (AAA) dan Acuros External Beam (AXB).
Penelitian ini diawali dengan tahapan (1) kalibrasi HU citra CBCT menggunakan fantom CIRS 002LFC (2) analisa dose volume histogram (DVH), (3) analisa gamma index dengan kriteria DD 2% / DTA 2mm serta DD 3% / DTA 3mm menggunakan perangkat EPID. Penyimpangan D98%, D50% dan D2% dari DVH dievaluasi dengan menjadikan citra CT algoritma AAA sebagai referensi. Diperoleh nilai penyimpangan D98%, D50% dan D2% tertinggi pada kasus kanker laring yaitu sebesar 9,08% ± 2,21 (CBCT AXBm - CT AAA), 0,74% ± 0,37 (CBCT AXBw - CT AAA) dan 3,79% ± 0,55 (CBCT AXBw - CT AAA).
Penyimpangan D98%, D50% dan D2% pada kasus kanker paru dan kanker prostat diperoleh lebih kecil dari 2%. Conformity index (CI) diperoleh pada rentang 0,98 ± 0,011 dan homogeneity index (HI) diperoleh pada rentang 0,08 ± 0,015. Analisa gamma index dengan kriteria 2%/2mm diperoleh pada range 87% - 94% dan kriteria 3%/3mm diperoleh 93% - 99%. Dari hasil penelitian ini didapati bahwa hasil kalkulasi dosis berdasarkan citra CBCT hampir sama dibandingkan dengan citra FBCT sehingga citra CBCT dilihat layak digunakan sebagai adaptive planning radiotherapy.  

The purpose of this study was to evaluate the accuracy of dose calculation based on Cone Beam Computed Tomography (CBCT) as adaptive planning. Treatment planning was generated for 3 patients larynx, 7 patients lung and 5 patients prostate using Intensity Modulated Radiotherapy (IMRT) and Volumetric Arc Therapy (VMAT). Eclipse v13.6 treatment planning system (TPS) with Analytical Anisotropic Algorithm (AAA) and Acuros External Beam (AXB) algorithm has been used to calculate the dose.
This study was divided into three major parts : (1) HU calibration for CBCT images by using CIRS phantom 002LFC (2) dose volume histogram (DVH) analysis, (3) analysis of Gamma Passing Rate with criteria DD 2% / DTA 2mm and DD 3% / DTA 3mm using EPID. The DVH analysis for D98%, D50% dan D2% deviation was evaluated and CT images with AAA algorithm used as reference. The highest deviation of D98%, D50% dan D2% was found for larynx cancer with value  9,08% ± 2,21 (CBCT AXBm - CT AAA), 0,74% ± 0,37 (CBCT AXBw - CT AAA) and 3,79% ± 0,55 (CBCT AXBw - CT AAA).
Deviation of D98%, D50% dan D2% for lung and prostate cancer is less than 2%. Range of conformity index based on CBCT images is 0,98 ± 0,011 and homogeneity index is in the range of 0,08 ± 0,015. The gamma criteria of dose difference and dose to agreement for 2%/2mm are 87% - 94% and for 3%/3mm are 96% - 98%. From the result, we found that the difference of dose calculation based on CBCT images is almost similar to CT images, so CBCT images are proper to be used for adaptive planning.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
T54121
UI - Tesis Membership  Universitas Indonesia Library
cover
Antonius Berwin
"Latar Belakang: Gigi impaksi merupakan kondisi ketika gigi mengalami kegagalan untuk erupsi sepenuhnya ke lengkung gigi dalam waktu yang diharapkan. Berdasarkan frekuensi kejadiannya, gigi molar tiga rahang bawah (M3 RB) paling sering mengalami impaksi dengan prevalensi mencapai 60.6% di Indonesia. Salah satu faktor lokal utama terjadinya gigi M3 RB impaksi adalah kurangnya ruang pada lengkung rahang bawah yang sering dikaitkan dengan proses pertumbuhan tulang mandibula. Beberapa studi menunjukkan bahwa ukuran morfologi tulang mandibula yang mencerminkan kuantitas dan arah pertumbuhan tulang seperti tinggi simfisis mandibula, panjang badan mandibula, dan sudut gonial berpotensi untuk mempengaruhi kejadian gigi M3 RB impaksi.
Tujuan: Mengevaluasi hubungan kejadian gigi M3 RB impaksi dengan morfologi tulang mandibula.
Metode: Sebanyak 110 sampel sisi rahang bawah diperoleh dari 67 data radiografi panoramik digital pasien RSKGM FKG UI (50 perempuan dan 17 laki-laki; usia: 21.22–30.91 tahun). Sampel yang tersedia kemudian dibagi menjadi kelompok kasus (sisi rahang dengan gigi M3 RB yang mengalami impaksi baik fully unerupted atau partially erupted) dan kelompok kontrol (sisi rahang dengan gigi M3 RB yang erupsi sempurna) untuk dilakukan perbandingan. Pada studi ini, uji-t independen dan uji Anova 1 arah digunakan untuk menganalisis hubungan status impaksi gigi M3 RB dan klasifikasinya dengan morfologi tulang mandibula pada data berdistribusi normal. Di sisi lain, uji Mann-Whitney U dan Uji Kruskal Wallis digunakan untuk menganalisis hubungan status impaksi gigi M3 RB dan klasifikasinya dengan morfologi tulang mandibula pada data berdistribusi tidak normal.
Hasil: Tinggi simfisis mandibula dan sudut gonial secara statistik (p < 0.05) lebih rendah pada kelompok kasus. Sementara itu, panjang badan mandibula antara kelompok kasus dan kelompok kontrol tidak berbeda secara statistik (p > 0.05). Pada hasil tinjauan pasien laki-laki saja, tidak ditemukan adanya perbedaan tinggi simfisis, panjang badan mandibula, dan sudut gonial antara kelompok kasus dan kelompok kontrol secara statistik (p > 0.05).
Kesimpulan: Terdapat hubungan kejadian gigi M3 RB impaksi dengan ukuran tinggi simfisis dan sudut gonial. Semakin kecil ukuran tinggi simfisis dan sudut gonial, semakin besar kemungkinan gigi M3 RB mengalami impaksi. Di sisi lain, tidak ditemukan adanya hubungan kejadian gigi M3 RB impaksi dengan ukuran panjang badan mandibula.

Background: An impacted tooth is a condition when a tooth fails to fully erupt into the dental arch within the expected time. Based on the frequency of occurrence, the mandibular third molar (M3M) is the most frequently impacted with a prevalence of 60.6% in Indonesia. One of the main local factors for impacted M3M is the lack of space in the lower arch which is often associated with the growth process of the mandibular bone. Several studies have shown that the size of the mandibular bone morphology that reflects the quantity and direction of bone growth such as symphisis mandibular height, mandibular body length, and gonial angle has the potential to influence the occurance of impacted M3M.
Objective: To evaluate the relationship between the occurance of impacted M3M and mandibular bone morphology.
Methods: A total of 110 samples of the mandibular side were obtained from 67 digital panoramic radiographic data of RSKGM FKG UI patients (50 women and 17 men; age: 21.22–30.91 years). The data were then divided into the case group (jaw side with M3M that were fully unerupted or partially erupted) and the control group (jaw side with M3M that fully erupted) for comparison. In this study, an independent t-test and 1-way ANOVA test was used to analyze the relationship between the impaction status of M3M and their classification with the morphology of the mandible in normally distributed data. On the other hand, the Mann-Whitney U test and the Kruskal Wallis test were used to analyze the relationship between the impaction status of the M3M tooth and its classification with the morphology of the mandible bone in abnormally distributed data.
Results: Symphisis mandibular height and gonial angle were statistically (p < 0.05) lower in the case group. Meanwhile, the mandibular body length between the case group and the control group was not statistically different (p > 0.05). In the results of the review of male patients only, there was no statistical difference in symphisis height, mandibular body length, and gonial angle between the case group and control group (p > 0.05).
Conclusion: There is a relationship between the occurance of impacted M3M with the size of the symphisis height and gonial angle. The smaller the size of the symphisis height and gonial angle, the more likely the M3M to experience impaction. On the other hand, there was no relationship between the occurance of impacted M3M and mandibular body length.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lumban Gaol, Refelina Evelina Margaretha
"[Latar Belakang: CBCT dapat mengukur ketebalan tulang mandibula dan ketebalan nervus alveolaris inferior yang dekat dengan kanalis mandibularis pada gigi M1 M2 M3 sehingga mampu mencegah kerusakan pada nervus alveolaris inferior. Tujuan: Memperkirakan ukuran ketebalan tulang mandibula dari apical gigi M1 M2 M3 tepat dekat kanalis mandibularis dengan CBCT sehingga dapat menentukan ketepatan dalam mendiagnosis, serta mencegah kerusakan pada nervus alveolaris inferior, mendapat kanposisi yang tepat dari M3 impaksi dan memberikan informasi yang detail mengenai anatomis struktur jaringan sekitarnya dengan kanalis mandibularis, adanya gambaran koronal, apikal, sagital dapat mengukur ketebalan tulang terutama daerah bukal dari nervus alveolaris inferior. Material dan metode: penelitian dilakukan di RSGM Ladokgi TNIAL R.E Martadinata antara September – November2014 dengan merekap data dari kartu status pasien rontgen foto CBCT. Usia pasien 14-60 tahun jumlah pasien 32 org laki-laki 14 perempuan 18 kriteria inklusinya berupa gambar CBCT kualitas dan densitas, kontrasnya baik. Adanya gigi M1M2M3 dekat dengan canalis mandibularis. Data penelitian ini menggunakan t-test analysis. Hasil: Adanya perbedaan significant antara ketebalan tulang laki-laki lebih tebal dari perempuan (p<0,5) dari hasil t test. Kesimpulan : Bahwa ketebalan tulang lakilaki lebih tebal dari perempuan., Aim: To measure side bone thickness of the mandible from apical teeth M1 M2 M3 right of canalis mandible by using CBCT. The accuracy diagnosis can be achieved long with preventing nervus demage. To give right information of M3 based on anatomical structure of surrounding tissue around canalis mandible. To the give the coronal, apical as well as features sagital future. Thus the bone thickness can be calculated correctly. Material and methods: the study was perfomed at RSGM Ladokgi TNI AL RE Mardinata during periode January with age patient 14-60 years old. Total patient 32 male14 female 18 CBCT feature. The inclusive patient are quality, contrast, and density of CBCT picture, M1 M2 M3 tooth near canalis mandible. The calculation was using t-test analysis. Result : there is a significant differencess between the bone thickness accuracy male and female (p<0,05). The bone thickness on male was thicker than female. Conclusion : from the result we conclude thet the bone thickness of male thicker the female.]"
Fakultas Kedokteran Gigi Universitas Indonesia, 2014
SP-PDF
UI - Tugas Akhir  Universitas Indonesia Library
cover
Maulianti
"Citra Cone Beam CT (CBCT) sangat berperan dalam menentukan keberhasilan verifikasi posisi pasien radioterapi, oleh karena itu jaminan kualitas sistem CBCT sangat diperlukan. Percobaan ini dilakukan dengan menggunakan pesawat Linear accelerator yang dilengkapi dengan CBCT dan CT Simulator GE Bright Speed Edge. Fantom Catphan® 600 dan CBCT Electron DensityTM digunakan untuk menilai kualitas dari citra CBCT dan linearitas CT Number. Sesuai dengan uji kualitas, citra pada CBCT hanya dapat membedakan kontras rendah dan kontras tinggi (udara, jaringan dan tulang).
Hasil uji ketebalan slice menunjukkan nilai yang didapat masih dalam batas toleransi ±0.5 mm. Pada uji kontras rendah bagian supra-slice untuk target kontras 1%, 0.5%, dan 0.3% nilai konstantanya sebesar 3, 2.5, dan 4.5, sedangkan pada bagian sub-slice untuk target kontras jarak 7, 5, dan 3 mm memiliki nilai konstanta 5 mm. Hasil pengujian resolusi tinggi pada CBCT dan CT Simulator adalah 3 lp/cm dan 7 lp/cm. Hasil pengujian uniformitas pada CBCT tidak memenuhi standar dari batas toleransi rata-rata CT Number tepi dan tengah kurang dari 5 HU, dan nilai setiap titik tepi dan tengah ±2 HU.

Cone Beam Computed Tomography (CBCT) image is very important in verification of patient positioning in the treatment couch radiotherapy machine so quality control of the system is required. The experiment was performed using the Linear accelerator with equipped with CBCT and CT simulator GE Bright Speed Edge. Catphan® 600 and CBCT Electron DensityTM phantom was used to evaluate the quality of CBCT and CT Number linearity. According to the image quality test, the CBCT image only be able to distinguish low contrast and high contras for air, tissue and bone.
Quantitavely, the slice thickness was in tolerance limit ±0.5 mm, low contrast with constant value of 3, 2.5, dan 4.5 for supra-slice contrast targets 1%, 0.5%, dan 0.3% whereas sub-slice targets axis lenghts for 3, 5, and 7 mm with constant value of 5 mm, the high resolution appear in 3 lp/cm and 7 lp/cm for CBCT and CT simulator, respectively. On the one hand, CBCT uniformity was out of tolerance limit with average CT number edge and central less than 5 HU, and ±2 HU for the edge and center point.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S45532
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ginting, William Carlos
"ABSTRAK
Latar belakang: Kecemasan dental merupakan respon stress pasien terhadap keadaan spesifik terkait perawatan dental. Ekstraksi gigi molar tiga mandibula impaksi merupakan perawatan dalam bedah kedokteran gigi yang paling sering menimbulkan kecemasan. Musik mengambil peran dalam mengurangi kecemasan pasien saat prosedur ekstraksi tersebut. Tujuan : Untuk mengetahui pengaruh musik pilihan pasien pada saat ekstraksi gigi molar tiga mandibula impaksi terhadap kecemasan dan membandingkannya dengan musik klasik. Metode : Penelitian ini menggunakan desain eksperimental single-blinded acak dengan kontrol di RSKGM FKG UI. Intervensi menggunakan musik dengan alat BoseÒ SoundWearÔ untuk memutarkan musik. Subjek penelitian dibagi dalam 3 kelompok : Musik Pilihan Pasien, Musik Klasik, dan Kontrol (tanpa musik). Operator ekstraksi adalah Mahasiswa Program Pendidikan Dokter Gigi Spesialis Bedah Mulut FKG UI. Pengukuran kecemasan menggunakan MDAS, APAIS, VAS, dan mengukur tanda vital. Pengukuran tanda vital, tekanan darah dan frekuensi nadi, menggunakan OMRON HEM-7130, JAPAN. Analisis data menggunakan SPSS dengan analisis bivariat Paired T-Test dan Independent T-Test pada setiap kelompoknya. Hasil : Terdapat pengurangan rata rata skor total tingkat kecemasan antara sebelum dan sesudah intervensi pada kelompok (A) musik pilihan pasien dan kelompok (B) musik klasik yang diukur dengan MDAS, APAIS, dan VAS (p < 0,05). Kelompok kontrol menunjukkan peningkatan tekanan darah dan frekuensi nadi sesudah intervensi (p < 0,05). Kesimpulan : Musik pilihan pasien dan musik klasik memberikan efek dalam mengurangi kecemasan pasien yang diukur dengan MDAS, APAIS, dan VAS dibandingkan tanpa menggunakan musik."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>