Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 132615 dokumen yang sesuai dengan query
cover
Fauzan Naufal Jassin
"Global warming is caused by human activity, one of them being fossil fuel combustion, which raises heat-trapping greenhouse gas levels in the atmosphere. Buildings consume a huge amount of energy and resources, causing damage on environment. Indonesia is committed to achieving net zero emissions by 2060. One way to reduce emissions is by conserving our energy consumption, such as using phase-changing materials for Thermal Energy Storage (TES). Thermal energy storage involves heating or cooling to be used later, thus balancing energy usage during low and high demand periods. Latent Heat Storage is a technology for developing energy-efficient buildings by utilizing phase change materials (PCMs). Solid-solid PCMs (SS-PCMs) are considered potential alternatives, as they can maintain the structure while material phase changes. The objective of this research is to determine the optimal thickness of SS-PCM and the energy savings achieved compared to DGW standard. Research was conducted through a Glass Reinforced Concrete (GRC) Box with cooling system such as evaporator and axial fan, calibrated and uncalibrated incandescent lamps, and 3 irradiation inputs (1000 W/m², 750 W/m², and 500 W/m²) for DGW and 5 thickness samples of DGW with SS-PCM (3 – 7 mm). This experiment resulted in better energy consumption with an average of 8,19% energy savings. 3mm SS-PCM has the highest energy savings of 16,15%. NPV and IRR analysis conducted indicate that the investment has the potential to generate a higher return than the cost of capital, meaning the investment is profitable.

Pemanasan global disebabkan oleh aktivitas manusia, salah satunya adalah pembakaran bahan bakar fosil yang meningkatkan tingkat gas rumah kaca di atmosfer. Bangunan mengonsumsi jumlah energi yang sangat besar, sehingga menyebabkan kerusakan pada lingkungan. Indonesia berkomitmen untuk mencapai emisi net zero pada tahun 2060. Salah satu cara untuk mengurangi emisi adalah dengan menghemat konsumsi energi, seperti menggunakan bahan-bahan yang mengalami perubahan fase untuk Penyimpanan Energi Panas. Penyimpanan energi panas melibatkan pemanasan atau pendinginan, sehingga menyeimbangkan penggunaan energi selama periode demand rendah dan tinggi. Bahan-bahan PCMs solid-solid (SS-PCMs) dianggap sebagai alternatif potensial, karena mereka dapat mempertahankan struktur sementara material mengalami perubahan fase. Tujuan dari penelitian ini untuk menentukan ketebalan optimal SS-PCM dan penghematan energi yang dicapai dibandingkan dengan DGW. Penelitian dilakukan melalui box GRC dengan sistem pendinginan seperti evaporator dan fan axial, lampu pijar yang dikalibrasi dan tidak dikalibrasi, serta 3 input iradiasi (1000 W/m², 750 W/m², dan 500 W/m²) untuk DGW dan 5 contoh sampel ketebalan DGW dengan SS-PCM (3 – 7 mm). Hasil eksperimen ini menunjukkan konsumsi energi yang lebih baik dengan rata-rata penghematan energi sebesar 8,19%. SS-PCM 3mm memiliki penghematan energi tertinggi sebesar 16,15%. Analisis NPV dan IRR yang dilakukan menunjukkan bahwa investasi memiliki potensi untuk menghasilkan return yang lebih tinggi daripada biaya modal, berarti investasi ini menguntungkan.
"
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alvin Hosea Widjaja
"Bangunan mempunyai konsumsi energi yang besar untuk pendinginan ruang demi mempertahankan lingkungan termal yang nyaman, dengan konsumsi energi keseluruhan di bangunan mewakili 36% dari semua sektor industri. Sistem HVAC menyumbang 49% dari konsumsi listrik di bangunan. Meningkatkan kinerja termal menggunakan Penyimpanan Energi Termal (TES) pasif dapat mengurangi konsumsi listrik dengan menurunkan beban pendinginan. Studi ini berfokus pada PCM Solid-solid (SS-PCM), yang menyerap dan melepaskan panas tanpa perubahan fase, sehingga mempertahankan kenyamanan termal tanpa enkapsulasi, memperpanjang penggunaan HVAC, dan meningkatkan efisiensi energi. SS-PCM Linear Polyurethane 2000 (PUL-2K) diintegrasikan ke dalam Jendela Ganda (DGW) untuk mengurangi suhu bangunan secara pasif. Penelitian ini bertujuan menentukan ketebalan optimal SS-PCM dan penghematan energi yang dicapai dibandingkan dengan DGW biasa. Eksperimen menggunakan Glass-Reinforced Concrete (GRC) dengan sistem pendingin disertai variasi iradiasi (1000 W/m², 750 W/m², dan 500 W/m²), serta lima sampel ketebalan SS-PCM DGW (3 – 7 mm), studi menemukan bahwa DGW dengan SS-PCM PUL-2K secara efektif mengurangi suhu ruangan. Ketebalan optimal SS-PCM PUL-2K adalah 3 mm, menghasilkan penghematan energi rata-rata 12,49%. Secara keseluruhan, DGW dengan SS-PCM PUL-2K mencapai penghematan energi hingga 16,15%, dengan rata-rata 8,19%, menunjukkan potensi signifikan untuk TES dalam konservasi energi bangunan.

Buildings consume a substantial amount of energy for space cooling to maintain a comfortable thermal environment, with the overall energy consumption in buildings representing 36% of all industrial sectors. HVAC systems account for 49% of electrical energy in buildings. Enhancing thermal performance using passive Thermal Energy Storage (TES) can reduce electrical energy consumption by lowering the cooling load. This study focuses on Solid-solid PCM (SS-PCM), which absorbs and releases heat without phase change, thus maintaining thermal comfort without encapsulation, extending HVAC usage, and improving energy efficiency. The SS-PCM Linear Polyurethane 2000 (PUL-2K) is integrated into Double Glazed Windows (DGW) to passively reduce building temperatures. The research aims to determine the optimal SS-PCM thickness and the energy savings achieved compared to standard DGW. Using a Glass Reinforced Concrete (GRC) Box with a cooling system, various irradiations (1000 W/m², 750 W/m², and 500 W/m²), and five thickness samples of SS-PCM DGW (3 – 7 mm), the study found that DGW with SS-PCM PUL-2K effectively reduces room temperature. The optimal thickness of SS-PCM PUL-2K is 3 mm, yielding an average energy savings of 12.49%. Overall, DGW with SS-PCM PUL-2K achieved energy savings up to 16.15%, with an average of 8.19%, indicating significant potential for TES in building energy conservation."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Prastika Dwi Agustin
"Indonesia merupakan salah satu negara yang memiliki iklim tropis. Dengan cuaca dan suhu ekstrem yang terjadi, hampir di seluruh bangunan menggunakan air conditioner untuk mendapatkan kenyamanan termal. Phase Change Material (PCM) merupakan Thermal Energy Storage (TES) dengan prinsip kerja kalor laten dapat dijadikan salah satu alternatif dalam mengurangi konsumsi energi akibat penggunaan air conditioner di bangunan.
Tujuan dari penelitian ini adalah untuk mengetahui karakteristik sifat termal, pada material bangunan yang diintegrasikan dengan material PCM yaitu beeswax. Dengan melakukan pengujian untuk mengetahui pengaruh dari penambahan beeswax ke material bangunan terhadap temperatur yang dihasilkan dan dibandingkan dengan material bangunan tanpa penambahan beeswax. Variasi dari penelitian ini adalah temperatur heater sebagai sumber panas (35, 40, 45 oC).
Hasil dari penelitian menunjukkan bahwa penambahan beeswax menghasilkan temperatur dinding dalam yang lebih rendah dibandingkan dengan yang tidak ditambahkan beeswax. Dengan konduktivitas termal batako-beeswax yang didapatkan dari hasil pengujian sebesar 0,0211-0,0212 W/moC dan difusivitas komposit sebesar 2,89x10-6 m2/s. Hal ini membuktikan bahwa dengan menambahkan PCM pada material bangunan, PCM akan menyerap kalor dan panas yang akan masuk ke ruangan akan tereduksi.

Indonesia is one of the countries that has a tropical climate. With the weather and extreme temperatures occurring, almost all buildings use air conditioner to get the thermal comfort. Phase Change Material (PCM) is a Thermal Energy Storage (TES) with latent heat working principle can be an alternative in reducing energy consumption due to the use of air conditioner in the building.
The purpose of this research is to determine the characteristics of thermal properties in building materials integrated with PCM material namely beeswax. By conducting thermal properties testing to determine the effect of adding a beeswax to the building material to the resulting temperature and compared to the building material without the addition of beeswax. Variations of this research is the temperature of heater as heat source (35, 40, 45 oC).
The results of the study showed that the addition of beeswax resulted in a lower inner wall temperature compared to those not added by beeswax. With the thermal conductivity of beeswax-concrete composite obtained from the test result are 0.0211-0.0212 W/m oC and the composite diffusivity at 2.89x10-6 m2/s. This proves that by adding PCM to the building material, the PCM will absorb the heat and the heat that enter the room will be reduced.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Faza Furqan Wibisana
"Indonesia merupakan negara yang beriklim tropis, menyebabkan Indonesia cenderung mendapatkan sinar matahari secara merata dan memiliki temperature yang cukup panas. Hal tersebut dapat dimanfaatkan sebagai keuntungan dalam pemanfaatan energi surya dan juga menyebabkan kerugian pada tinggi nya suhu pada ruang bangunan akibat energi termal. panasnya energi termal menyebabkan ketidaknyamanan termal pada bangunan, sehingga dibutuhkan sistem pendinginan ruangan yang dapat menyebabkan peningkatan konsumsi listrik. oleh karena itu sistem konservasi energi merupakan solusi yang tepat untuk mengatasi permaslahan tersebut. penelitian ini menggunakan sistem Closed loop pulsating heat pipe dengan fluida kerja biner DI Water- Methanol untuk konservasi energi pada bangunan Gedung. Closed loop pulsating heat pipe bekerja dengan prinsip heat exchange pada tiga bagian yaitu evaporator, adiabatic dan kondensor. bagian evaporator diharapkan dapat menyerap panas dan menggerakan fluida kerja sebagai medium perpindahan panas melalui bagian adiabatik ke bagian kondensor untuk melepas panas. studi ini dilakukan untuk mengetahui kinerja sistem CLPHP dengan fluida kerja biner DI Water-Methanol sebagai perangkat reduksi termal dan konservasi energi Gedung serta pemanfaatan Kembali panas yang dilepas pada bagian kondensor sebagai pemanas air. eksperimen ini menggunakan variasi antara lain Mixing ratio 10:1, 5:1, 1:1, 1:5, 1:10 sudut inklinasi 5°, 10° , 15° dan Heat Input 25 W 35 W 45 W. Hasil pengujian menunjukan bahwa Mixing ratio 1:5 dengan sudut inklinasi 5 danHeat Input 45 W menghasilkan hasil paling optimum dengan nilai resistensi termal (0,741°C/W) dan perolehan suhu akhir pada tangki kondensor (34,89 °C).

Indonesia is a tropical country, which means it tends to receive sunlight evenly and has relatively high temperatures. This can be leveraged as an advantage in the utilization of solar energy but also poses a disadvantage in terms of high indoor temperatures due to thermal energy. The heat from thermal energy causes thermal discomfort in buildings, necessitating cooling systems that can increase electricity consumption. Therefore, energy conservation systems are an appropriate solution to address this issue. This research utilizes a Closed loop pulsating heat pipe (CLPHP) system with a binary working fluid of DI Water-Methanol for energy conservation in buildings. The Closed loop pulsating heat pipe operates on the principle of heat exchange in three sections: the evaporator, the adiabatic section, and the condenser. The evaporator is expected to absorb heat and move the working fluid as a heat transfer medium through the adiabatic section to the condenser to release heat. This study aims to determine the performance of the CLPHP system with the binary working fluid DI Water-Methanol as a thermal reduction device and energy conservation for buildings, as well as the reutilization of heat released in the condenser section for water heating. This experiment employs variations including Mixing ratios of 10:1, 5:1, 1:1, 1:5, 1:10; inclination angles of 5°, 10° , 15°; and Heat Inputs of 25 W, 35 W, and 45 W. The test results show that working fluid with Mixing ratio of 1:5 with an inclination angle of 5° and a Heat Input of 45 W produces the most optimal results with thermal resistance value of 0.741 °C/W and a final temperature gain in the condenser tank of 34.89°C."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Salma Ilmiati
"ABSTRAK
Lignin adalah salah satu biopolimer terbanyak didunia. Lignin memiliki sisi polar dan nonpolar akibat struktur yang bercabang. Namun, berdasarkan penelitian sebelumnya, tendensi kepolaran lignin lebih besar dibandingkan kenonpolarannya. Lignin berpontensi sebagai kompatibiliser yang baik apabila kenonpolarannya dapat ditingkatkan. Penelitian ini bertujuan untuk mensintesis hibrida poliuretan berbasis lignin HPL untuk meningkatkan kenonpolaran lignin. HPL dihasilkan dari reaksi 4,4 39;- Methylenebis Cyclohexyl Isocyanate HMDI dengan variasi komposisi , PEG 6000 dan lignin. Variasi suhu ketika reaski dengan lignin juga dilakukan dengan variasi 80 hingga 100 C. Struktur HPL dikomfirmasi menggunakan nuclear magnetic resonance spectroscopy NMR dan fourier transform infrared spectroscopy FTIR . Berdasarkan NMR dan FTIR, HPL berhasil dihasilkan. NMR juga digunakan untuk menghitung rasio kepolaran HPL. Berdasarkan NMR, rasio kepolaran HPL menurun dari 0,069 ke 0,041 seiring meningkatnya komposisi HMDI. Peningkatan kenonpolaran juga dikonfimasi dengan tegangan permukaan hasil pengujian sessile drop. Tegangan permukaan HPL menurun seiiring dengan meningkatnya komposisi HMDI dengan nilai tegangan permukaan terkecil adalah 46,4 nM/m. Sifat termal HPL juga diuiji menggunakan STA. Berdasarkan STA, Td semakin meningkat seiring dengan meningkatnya komposisi dari HMDI dan suhu yang disebabkan oleh terbentuknya crosslinking. Nilai Td terbaik dimiliki oleh HPLE dengan nilai 417,6 C.

ABSTRACT
Lignin is one of the most abundant biopolymer on earth. It has polarity and non polarity side due to its hyperbranched structure, but the polarity of lignin has a higher tendency than non polarity. Lignin has potential to be compatibilizing agent if the portion of non polarity can be increased. This research is focused on investigation of synthesize lignin based polyurethane to enhance the portion of non polarity in lignin. Lignin based polyurethane was prepared by reacting 4,4 39 Methylenebis Cyclohexyl Isocyanate HMDI with variation compositions and polyethylene glycol PEG Mw 6000, then lignin was added to the reaction. The temperature of reaction for lignin also variated between 80 to 100 C. In this study, the structure of lignin based polyurethane was confirmed by nuclear magnetic resonance spectroscopy NMR and fourier transform infrared spectroscopy FTIR . NMR and FTIR showed that lignin successfully grafted. NMR, also used to investigated the effects of variation composition of diisocyanate contents to polarity of lignin based polyurethane. Based on NMR the ration p np decrease from 0.069 to 0,041 with the increasing of composition HMDI. The enhance of nonpolarity HPL also confirm by the value of surface tension from sessile drop. it show that the surface tension of HPL decline as the increasing of the composiiton of HMDI. The best serface tension was from HPLE with 46.4 nM m. Thermal properties of lignin based polyurethane also investigate using STA. The result was the increasing of thermal degradation of lignin based polyurethane as well as the increasing of composition HMDI and temperature condition, cause of the crosslingking in lignin. Td largest value is 417,6 C from HPLE"
2017
T47836
UI - Tesis Membership  Universitas Indonesia Library
cover
Herfira Triana
"Secara global, konsumsi energi pada bangunan didominasi sebesar 55% oleh penggunaan energi listrik selama bangunan beroperasi. Sementara di Jakarta, sebesar 15 – 25% dari keseluruhan konsumsi energi digunakan untuk sistem pencahayaan buatan, berdasarkan riset tahun 2009. Untuk menurunkan konsumsi energi, serta mengurangi dampak negatif emisi pada lingkungan, diterapkan upaya peningkatan efisiensi energi. ASHRAE 189.1 merupakan standar yang disusun oleh sebuah asosiasi profesional Amerika, yang menjadi acuan teknis dunia untuk mendesain bangunan dengan penggunaan energi yang efisien. Melihat pencahayaan buatan pada bangunan seni multifungsi memegang peran yang penting, konsumsi energi pada tipe bangunan ini berpotensi didominasi oleh sistem pencahayaannya.
Penulisan ini mengkaji sistem pencahayaan buatan pada salah satu bangunan seni multifungsi, yaitu Makara Art Center Universitas Indonesia, untuk mengetahui apakah konsumsi energi sistem pencahayaan buatan pada bangunan telah efisien menurut standar ASHRAE 189.1. Kajian ini diawali dengan meninjau literatur yang berkaitan dengan bahasan, dilanjutkan dengan mengukur dan mengevaluasi iluminasi sistem pencahayaan bangunan studi kasus secara manual berdasarkan standar SNI 7062: 2019 serta dengan simulasi menggunakan perangkat lunak DIALux evo 10.1, yang kemudian disetarakan dengan standar ASHRAE 189.1. Hasil pengukuran 36 ruangan pada bangunan ini menunjukkan konsumsi energi untuk sistem pencahayaannya berlebih sebesar 0.17%. Berdasarkan 6 ruangan yang mengkonsumsi energi berlebih, terdapat 5 ruang yang lebih dominan menggunakan pencahayaan alami. Maka secara keseluruhan, konsumsi energi untuk sistem pencahayaan buatan Makara Art Center telah mendekati efisien, namun tetap dapat ditingkatkan kembali.

Globally, energy consumption in buildings is dominated by 55% use of electrical energy during building operations. Meanwhile in Jakarta, 15 – 25% of the total energy consumption is used for artificial lighting systems, based on research in 2009. To reduce energy consumption, and reduce the negative impact of emissions on the environment, efforts to improve energy efficiency are implemented. ASHRAE 189.1 is a standard compiled by an American professional association, which is a world’s technical reference for designing buildings with energy efficient use. Seeing that artificial lighting in multifunctional art buildings plays an important role, energy consumption in this building type has the potential to be dominated by the lighting system.
This paper examines the artificial lighting system in one of the multifunctional art buildings, namely Makara Art Center Universitas Indonesia, to find out whether the energy consumption of the artificial lighting system in the building is efficient according to ASHRAE 189.1 standards. This study begins by reviewing the literature related to the discussion, followed by measuring and evaluating the lighting system’s illumination of the case study building manually based on the SNI 7062: 2019 standard and by simulating it using the DIALux evo 10.1 software, which is then compared to the ASHRAE 189.1 standard. The measurement results of 36 rooms in this building show that the energy consumption for the lighting system is 0.17% excessive. Based on 6 rooms that consume excess energy, there are 5 rooms that use natural lighting more dominantly. So overall, the energy consumption of Makara Art Center's artificial lighting system is nearly efficient, but still can be increased.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kuat Riyanto
"Pemakaian energi pada gedung merupakan sumber terbesar konsumsi energi. green building merupakan konsep penghematan energi yang berstandar internasional. Audit energi bangunan menggunakan simulasi software adalah salah satu cara untuk mengetahui bagaimana konsumsi energi bangunan dan mencari alternatif untuk mengurangi konsumsi energinya agar memenuhi kriteria sebagai gedung hemat energi. Dalam penelitian ini digunakan software EnergyPlus yang memiliki keunggulan dibanding software simulasi energi lainnya. Simulasi dilakukan dengan menggunakan sistem pendingin unitary dan VAV pada rancangan gedung MRC FT-UI. Dari hasil simulasi tersebut diketahui bahwa sistem VAV merupakan sistem yang lebih efisien dengan konsumsi energi sebesar 1386,67 GJ/tahun dan dapat menjaga dengan baik kondisi kenyaman ruangan pada temperatur 24,5 oC dan relative humidity antara 45%-65%.

Energy used in buildings is the largest source of energy consumption. Green building is the concept of energy saving or energy efficient based on international standard. Energy audits of buildings using the simulation software is one of the way to find out how the building energy consumption and find alternatives to reduce the energy consumption of its buildings to meet the criteria as energy- efficient buildings. This study used the EnergyPlus software which has more advantage then the other energy simulation software. The simulation using unitary and VAV cooling system in the MRC FT-UI building. From the simulation results can be known that the VAV system is more efficient with energy consumption of 1386,68 GJ/year and can maintain good indoor comfort conditions at the temperature of 24,5 oC and relative humidity between 45% -65%."
Depok: Fakultas Teknik Universitas Indonesia, 2011
S1068
UI - Skripsi Open  Universitas Indonesia Library
cover
Jana Hafiza
"ABSTRAK
Poliuretan merupakan jenis polimer yang dihasilkan dengan mereaksikan bahan kimia reaktif poliol dan diisosianat. Penambahan lignin pada poliuretan dapat dijadikan sebagai kompatibiliser karena lignin memiliki gugus polar dan nonpolar. Penelitian ini dilakukan pembuatan produk hibrida poliuretan berbasis lignin dengan menggunakan polietilen glikol PEG dan 4,4 rsquo; metilenbis sikloheksil isosianat HMDI serta lignin sebagai kompatibiliser. Variabel yang digunakan adalah penambahan berat molekul PEG dan mol HMDI dengan 0,5 gram lignin. Produk kemudian dikarakterisasi dengan menggunakan FT-IR Fourier Transform Infra-Red Spectroscopy , 1H-NMR Nuclear Magnetic Resonance , STA Simultaneous Thermal Analysis , SEM Scanning Electron Microscopy , serta sudut kontak. Hasil pengujian NMR diketahui bahwa gugus hidrogen meningkat seiring dengan peningkatnya berat molekul PEG. Spektra FTIR memperlihatkan pita serapan gugus alkohol yang lebih tinggi dengan penggunaan PEG 6000. Berdasarkan grafik STA terlihat bahwa bertambahnya berat molekul PEG akan semakin meningkatkan temperatur melting dan temperatur dekomposisi. Kestabilan termal terlihat lebih baik dengan penggunaan PEG 6000. Indeks perbandingan polar dan nonpolar pada produk hibrida poliuretan berbasis lignin meningkat seiring meningkatnya kadar HMDI. Dari pengujian contact angle diketahui bahwa meningkatkan berat molekul PEG meningkatkan sifat kenonpolaran produk hibrida poliuretan berbasis lignin.

ABSTRACT
Polyurethane is a polymer formed by reacting the reactive chemicals of polyols and diisocyanates. The addition of lignin to the polyurethane can be used as a compatibilizer because lignin has a polar and nonpolar group. In this research, the product formed by using polyethylene glycol PEG and 4,4 39 methylenebis cyclohexyl isocyanate HMDI and lignin as the compatibilizer. The variable used the addition of molecular weight of PEG and mole of HMDI with 0.5 gram lignin Characterized of product by FT IR Fourier Transform Infra Red Spectroscopy , 1H NMR Nuclear Magnetic Resonance , STA Simultaneous Thermal Analysis , SEM Scanning Electron Microscopy , and contact angle. The results of the NMR test show that the hydrogen group increases by increase the molecular weight of PEG. FTIR spectra showed higher absorption band of alcohol group with using PEG 6000. Based on STA showed that increasing PEG molecular weight will further increase melting temperature and decomposition temperature. Thermal stability looks increase with the use of PEG 6000. The polar and nonpolar comparison index on lignin based polyurethane hybrid products increases with increasing HMDI levels. Contact angle testing showed that increasing the molecular weight of PEG and mole of HMDI increases the nonpolar sides of lignin based polyurethane hybrid products."
2017
T48698
UI - Tesis Membership  Universitas Indonesia Library
cover
Nurul Halida Ibrahim
"Peninjauan ini bertujuan untuk mempelajari faktor optik pada kaca pada laminasi yakni nilai-U, nilai SHGC, serta penambahan lapisan kaca pada kaca laminasi terhadap perubahan suhu dalam bangunan. Metode yang dilakukan adalah pengkajian literatur yang kemudian dijadikan landasan untuk melakukan observasi pada Bangunan FISIP yang terletak di Depok, sebagai salah satu contoh kasus bangunan yang terletak pada daerah beriklim tropis. Kemudian dilakukan simulasi untuk melihat perubahaan suhu ruangan dengan menggunakan jenis kaca laminasi dengan nilai optik yang berbeda. Dari hasil simulasi, ditemukan bahwa penggunaan teknologi tunggal pada kaca laminasi bening mampu menghasilkan suhu ruangan dengan rentang 30.2oC - 31.4 oC, sedangkan pada jenis kaca laminasi berwarna menghasilkan suhu dengan rentang 29 oC -30.2 oC. Pada penggunaan teknologi ganda terjadi penurunan suhu yang tinggi, dimana suhu tersebut berada pada rentang 27,1 oC - 28,5 oC. Hal ini menunjukkan bahwa dengan menggunakan teknologi ganda mampu menciptakan performa termal yang baik pada bangunan. Tetapi, dari hasil pertimbangan biaya yang akan dikeluarkan, penggunaan teknologi ganda tidak boleh digunakan pada seluruh bidang pada bangunan tinggi di iklim tropis
The aim of this article was to observe and analyze factors that may affected optic glass including U-value, SHGC value, and additional layer application of laminated glass (double glazing technology) in building temperature changes. This article represents a synthesis of an extensive literature review then became a baseline to observe FISIP buildings, located in Depok, as one of the buildings sample for tropical climates. In addition, we also did the stimulation test to observe alteration in room temperature by using 2 types of laminated glasses with different optical values. We found that single glazing technology application on clear laminated glass adjusted room temperature from 30.2oC to 31.4 oC. Whereas single color laminated glass application, set the room temperature ranges between 29 oC to 30.2 oC. Interestingly, the application of double glazing reduced the indoor temperature between 27.1 oC to 28.5 oC. These results showed that the significance of thermal performance of buildings can be accomplished by application of double glazing technology. Nevertheless, double glazing technology were not suggested to apply in all of edge of tropical building design due to the high cost issues."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gafero Priapalla Rahim
"Pada desain bangunan saat ini, pemakaian ruang terbuka ukuran besar dengan ketinggian ceiling sudah banyak dipakai. Panas dan asap adalah faktor yang membuat kebakaran berbahaya. Menggunakan model eksperimental dengan ukuran 2.4m x 1.6m x 1m, sirkulasi asap saat kebakaran diteliti dalam penelitian ini. Efek penimbunan dan pembuangan asap berkorelasi dengan kepekatan, temperatur, heat release rate dan laju pembuangan massa. Penggunaan sabut kelapa yang dibakar dengan menggunakan kompor berventilasi mekanik dapat menggambarkan kebakaran membara dengan laju produksi asap yang tinggi. Penggunaan massa sabut kelapa sebesar 40, 60 & 80 gr dapat mensimulasikan kondisi penumpukan asap dengan tingkat kepekatan asap yang sangat tinggi hingga 99%. Berdasarkan persamaan physical scale models dengan pendekatan nondimensional, nilai HRR untuk pengujian 40 gr, 60 gr & 80 gr sabut kelapa setara dengan kebakaran pada kursi, sofa dan unit kasur. Pada eksperimen pembuangan asap, semakin banyak sabut kelapa yang digunakan untuk eksperimen, maka akan semakin lama asap terbuang.

In many building designs nowadays, large open spaces with high ceilings are becoming more common. Heat and smoke are the two things that make a fire hazardous. Using an experimental enclosure model that measures 2.4m x 1.6m x 1m in a Scaled Atrium Compartment, researchers examine smoke circulation during a fire incident in a large space. The effect of smoke filling and clearance correlation on occupancy density, temperature, heat release rate and mass loss observed. The use of coconut fiber that is burned using a mechanically ventilated stove can describe a smoldering fire with a high smoke production rate. The use of coconut coir mass of 40, 60 & 80 grams can simulate smoke filling conditions with a very high level of smoke thickness with an optical density level of up to 99%. Based on the physical scale models with non dimensional similarity, the heat release rate from the 40gr, 60gr, and 80gr of burning coconut fibres is equivalent to the heat release rate gained by burning of cotton chair, polyurethane chair, and mattress. In the smoke clearance experiment, the more coconut fiber used, the longer the smoke will be thrown away."
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>