Ditemukan 18 dokumen yang sesuai dengan query
cover
Sholeh Hadi Pramono
"A study on the design and construction of measurement system of electric current of power line has been carried out. The electromagnetic induction on inductor placed near a power line was used as modulator signal of laser diode. The modulator signal in frequency signal form is obtained by converting the amplitude of induced voltage into frequency signal by voltage-to-frequency converter. The optical light of laser diode modulated by the frequency signal was transmitted by optical fiber. At the output of the fiber, the optical light was detected and converted by optical detector into electrical signal. The electrical signal was then demodulated and amplified by a receiver to be measured by a frequency counter. The experimental result shows a linear property of induced voltage as a function of current in the power line; the frequency as a function of voltage and current is also linear; the frequency on transmitter is the same with the frequency on receiver. It is concluded that the system designed and constructed in this study is applicable for remote measurement of electric current of power line."
Depok: Universitas Indonesia, 1990
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Sukarsan
"Piranti pengukuran besaran listrik sangat diperlukan, terutama bagi perusahaan listrik dan perusahaan lainnya yang memakai daya listrik cukup besar. Baik untuk mengecek kelayakan daya yang tersuplay maupun untuk mengkalibrasi peralatan tertentu yang menggunakan tegangan rendah maupun tegangan tinggi. Pada peralatan tertentu seperti unit Roentgen, diperlukan pengkalibrasian secara rutin. Pengukuran arus tabling merupakan salah satu parameter yang harus dikalibrasi. Pada pengukuran arus tabling pada unit Roentgen diperlukan alat ukur arus yang safety serta mampu meng-hold arus yang mengalir beberapa saat tersebut agar hasil pembacaan arus dapat terbaca. Pada skripsi ini dirancang-bangun suatu alat ukur arus puncak sesaat secara tak sentuh. Alat ini menggunakan mikrokontroller AT90S8535 sebagai pengatumya. Sensor arus yang digunakan yaitu current transformer atau lebih dikenal dengan tang ampere. Sensor ini bekerja atas dasar prinsip induksi elektromagnetik, sehingga hanya dapat digunakan pada arus listrik AC atau DC berdenyut. Sesuai dengan karakteristik arus tabling pada unit Roentgen, alat ukur ini bekerja baik pada arus listrik dengan frekuensi rendah yaitu antara 50Hz sampai 120 Hz dan memiliki besar amplitude yang stabil. Alat ukur yang berhasil dirancang-bangun mempunyai prosentase kesalahan pengukuran sebesar 5 % pada pengukuran arus listrik sinusoida dengan frekuensi 50 Hz dan periode mengalimya arus antara 0,5 detik sampai 1 detik."
Depok: Fakultas Teknik Universitas Indonesia, 2006
S40728
UI - Skripsi Membership  Universitas Indonesia Library
cover
Asrizal Tatang
"Saat dilakukan penutupan pada pemutus tenaga terhadap tegangan sumber transformator diperkirakan timbul arus sampai beberapa kali arus normalnya atau yang lebih dikenal dengan arus Inrush. Akibat dari arus Inrush ini dapat menimbulkan pengaruh terhadap unjuk kerja jari rele-rele pengaman Transformator yang pada akhirnya dapat menghambat kontinuitas pelayanan terhadap tenaga listrik. Karena sudut penutupan yang terjadi saat dilakukan penutupan pemutus tenaga tidak bisa dikontrol dan dilihat dari akibat arus inrush diatas terhadap kontinuitas pelayanan, maka perlu ditentukan pedoman dan data untuk dapat memperkirakan arus inrush yang mungkin terjadi saat penutupan pemutus tenaga. Dari hasil percobaan dan perhitungan terlihat bahwa sudut penutupan pemutus tenaga mempunyai pengaruh terhadap besarnya arus Inrush maksimum yaitu semakin kecil sudut penutupan semakin besar arus Inrush yang terjadi dan sebaliknya semakin besar sudut penutupan semakin kecil arus Inrush yang terjadi."
Depok: Lembaga Penelitian Universitas Indonesia, 1993
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Yayasan Bina Usaha Lingkungan
Jakarta: YBUL,
333.793 YAY l
Buku Teks  Universitas Indonesia Library
cover
"Dalam sistem transmisi dan distribusi daya listrik, banyak terdapat sambungan kabel. Sambungan kabel ini memiliki resistansi yang dapat membuat rugi daya meningkat. Semakin besar resistansi sambungan maka semakin besar rugi daya sehingga membuat temperatur sambungan semakin tinggi. Besar resistansi sambungan dipengaruhi oleh beberapa faktor antara lain luas permukaan sambungan, besar arus yang melewati sambungan tersebut serta kekuatan sambungan. Oleh karena itu dilakukan pengujian dengan menggunakan variasi faktor permukaan sambungan tersebut. Bila arus yang dialirkan semakin besar, maka resistansi sambungan semakin besar karena sambungan mengalami kenaikan temperatur yang lebih cepat dibandingkanjika dialirkan arus yang lebih kecil. Dari pengujian didapatkan bahwa semakin kecil kekuatan sambungan mengakibatkan semakin besar rongga udara sehingga resistansi sambungan semakin besar. Dengan demikian semakin kecil luas permukaan sambungan maka temperatur sambungan lebih tinggi."
Fakultas Teknik Universitas Indonesia, 2006
S40751
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nibras Fitrah Yayienda
"SNSU-BSN adalah lembaga yang berada di puncak ketertelusuran fisis di Indonesia dan disarankan memilki penjaminan kualitas pengukuran sesuai dengan arahan ISO 17025:2017 klausa 7.7 tentang pemastian keabsahan hasil. Namun demikian, sejauh ini penjaminan kualitas pada standar referensi di bidang metrologi kelistrikan belum pernah dilakukan. Hal ini dibuktikan dengan hasil peer review untuk tahun 2017 dan 2019 pada parameter tegangan AC/DC dan arus AC/DC bahwa belum ada proses penjaminan kualitas pada kedua parameter ini. Untuk itu, diperlukan sebuah metode untuk melakukan penjaminan kualitas pengukuran diantara periode kalibrasi, untuk memastikan keabsahan hasil ukur dalam rentang waktu tersebut. Pada penelitian ini diusulkan suatu metode penjaminan mutu pengukuran untuk memastikan kualitas hasil pengukuran diantara periode kalibrasi. Metode penelitian yang digunakan adalah dengan melakukan cek antara yang termasuk didalamnya terdapat proses pembentukan batas kontrol dan melakukan pengujian pada setiap bulan dalam kurun waktu 1 tahun. Pada proses ini, hasil ukur yang keluar dari batas kontrol akan dianalisa lebih lanjut dengan menggunakan Uji Ditribusi F dan Uji T-Student. Uji Distribusi F yang digunakan untuk mengetahui kesetaran sebaran hasil ukur lama dan baru dan Uji T-Student yang digunakan untuk mengetahui kesetaraan rata-rata hasil ukur lama dan baru. Titik ukur yang digunakan pada penelitian ini adalah 1 V dan 10 V pada paremter VDC; 1 mA dan 10 mA pada parameter IDC; 1 V dan 10 V dengan frekuensi masing-masing 1 kHz pada parameter VAC, serta 1 mA dan 10 mA dengan frekuensi masing-masing 1 kHz pada parameter IAC. Dari hasil pengujian diperoleh bahwa pada parameter VDC, tidak diperlukan pembaruan batas kontrol. Selanjutnya pada parameter titik ukur 1 mA dan 10 mA, masing-masing terdapat dua kali dan lima kali pembaruan batas kontrol. Kemudian pada parameter VAC terdapat dua kali pembaruan batas kontrol pada titik ukur 1 V dengan frekuensi 1 kHz, dan tidak diperlukan perbaruan batas kontrol pada titik ukur 10 V dengan frekuensi 1 kHz. Selanjutnya, pada titik ukur 1 mA dan 10 mA dengan frekuensi masing-masing 1 kHz, dibutuhkan dua kali pembaruan batas kontrol. Penyebab pembaruan batas kontrol adalah keluarnya hasil ukur dari batas kontrol yang disebabkan oleh drift. Namun demikian, meskipun nilai tersebut bergeser, pengukuran dalam periode tersebut valid, dan terjamin kualitasnya karena tidak ada yang melebihi nilai spesifikasi yang diberikan oleh pabrik.
......As an institution holding the highest level of physical traceability in Indonesia, SNSU BSN is encouraged to have quality assurance of measurements under the directives of ISO 17025:2017 clause 7.7 to ensure the validity of the result. However, quality assurance has never been carried out on reference standards in the field of electrical metrology. This is proved by the results of peer reviews for 2017 and 2019 for the parameters of AC/DC voltage and AC/DC current that there is no quality assurance process for these two parameters. For this reason, a method is needed to guarantee the quality of measurements between calibration periods to ensure the validity of the measurement results within that period. Therefore, this study proposes a measurement assurance method to ensure the quality of measurement results between calibration periods. The research method is an intermediate check, including establishing control limits and conducting monthly tests for one year. In this process, the measurement results that are out of the control limits will be further analyzed using the F Distribution Test and the Student T-Test. The F distribution test determines the variability equivalence, and the Student T-Test determines the variability in an average of former and latest measurement results. The measuring points used in this study were 1 V and 10 V on the VDC parameter; 1 mA and 10 mA on IDC parameters; 1 V and 10 V with a frequency of 1 kHz each on the VAC parameter and 1 mA and 10 mA with a frequency of 1 kHz each on the IAC parameter. From the test results, it is found that the VDC parameter does not need the update of the control limit. Furthermore, at the 1 mA and 10 mA measuring point parameters, there are two and five times updates of the control limits, respectively. Then in the VAC parameter, there are two updates of the control limit at the 1 V measuring point with a frequency of 1 kHz and no update of the control limit at the 10 V measuring point with a 1 kHz frequency. Furthermore, at the 1 mA and 10 mA measurement points with a frequency of 1 kHz each, it takes the twice updates of the control limit. The cause of updating the control limit is the out-of-control measured value caused by drift. However, even though the value has shifted, the quality is valid and guaranteed in that period because no measurement value exceeds the specifications determined by the manufacturer."
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Nuril Aditya Dewi
"Pada gardu induk sebagai pusat pengaturan pelayanan beban dalam sistem tenaga listrik harus dipasang sistem pentanahan yang handal. Sistem pentanahan pada gardu induk berfungsi sebagai pengaman personil dan peralatan-peralatan listrik pada gardu induk dengan desain yang umumnya digunakan adalah desain sistem pentanahan Grid-Rod yang menggunakan konduktor grid yang ditanam sejajar dengan permukaan tanah pada kedalaman tertentu dan ditambahkan penanaman batang-batang pentanahan secara vertikal. Skripsi ini akan membahas optimalisasi rancangan sistem pentanahan Grid-Rod pada gardu induk 150 kV dalam PLTP Ulubelu berdasarkan standar IEEE 80-2000 dengan menggunakan kalkulator desain Microsoft Excel dan modul Ground Grid Systems ETAP 7.0.0.
Dari hasil simulasi dengan memodifikasi variabel desain terkait konfigurasi konduktor grid, kedalaman penanaman konduktor grid dan konfigurasi batang pentanahan, diperoleh bahwa rancangan sistem pentanahan Grid-Rod yang paling optimal secara teknis dan ekonomis adalah konfigurasi konduktor grid dengan ukuran kisi-kisi (mesh) 6 x 5 meter, kedalaman penanaman konduktor grid sejauh 0,6 meter dari permukaan tanah dan batang pentanahan sebanyak 4 buah. Desain ini menghasilkan nilai tahanan pentanahan sebesar 0,56 Ohm, tegangan sentuh sebesar 639,3 Volt dan tegangan langkah sebesar 497,7 Volt yang telah memenuhi standar aman IEEE 80-2000.
......
On substation as the center of load service controlling in electrical power system must be installed a reliable grounding system. Grounding system on substation has a function for the protection of personnel and electrical equipments in substation with commonly used design is the design of Grid-Rod grounding system which using grid conductor are planted parallel to the ground surface at a certain grid depth and then added some ground rods. This thesis will research how to optimize design of Grid-Rod grounding system for 150 kV Ulubelu substation based on IEEE Std 80-2000 by using calculator for designing Grid-Rod grounding system on Microsoft Excel and Ground Grid Systems modul on ETAP 7.0.0.
From the result of simulation by modifying the associated design variable of grid conductor’s configuration, grid depth and ground rod’s configuration, founded that most technically and economically optimal design is the grid conductor’s configuration with mesh size 6 x 5 meter , grid depth as far as 0,6 meter from the ground surface, and 4 ground rods. This design will result grounding resistance value 0,56 Ohm, touch voltage 639,3 Volt and step voltage 497,7 Volt which have met the requirements of a safety standard IEEE 80-2000."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S47622
UI - Skripsi Membership  Universitas Indonesia Library
cover
Darrell Sanjaya
"Hidrogen merupakan salah satu bahan bakar yang diusulkan sebagai energi karena memiliki sifat ramah lingkungan serta memiliki kapasitas penyimpanan energi tinggi (143 MJ/kg). Hidrogen dapat diproduksi melalui proses elektrolisis sehingga lebih ramah lingkungan dibandingkan proses steam methane reforming (SMR). Pada dasarnya, elektrolisis larutan NaCl memiliki prinsip mengubah energi listrik menjadi energi kimia. Beberapa faktor yang mempengaruhi efisiensi energi dalam konversi ini adalah bahan dan geometri elektroda, konsentrasi larutan, pola alir larutan, serta elektron transfer pada permukaan. Untuk memastikan transfer elektron maksimal, tipe aliran yang digunakan adalah elektrolisis kontinyu. Dalam hal ini, larutan yang digunakan adalah larutan NaCl pada konsentrasi 1M dan 2M. Selain itu, terdapat variasi ukuran mesh, yakni 30; 40; 60; 80; dan 100, dengan variasi arus listrik pada 3A dan 5A. Bahan elektroda yang digunakan adalah lembaran Stainless Steel (SS316) yang digulung sehingga membentuk elektroda sirkular. Didapatkan hasil laju produksi gas hidrogen tertinggi pada 2 gulung mesh untuk konsentrasi 2M hingga 40mL/s dibandingkan dengan 1 gulung mesh yang hanya 35mL/s. Efisiensi energi tertinggi didapat pada mesh 60 (35,7%), disusul dengan mesh 80 (29,8%). Pada mesh 100 terdapat penurunan efisiensi (27,9%). Hal ini diakibatkan karena pembentukkan senyawa Fe yang mengendap pada permukaan aktif elektroda.
......Hydrogen is proposed as a fuel source due to its high energy storage capacity (143 MJ/kg).Although commonly produced through steam methane reforming, production through electrolysis is more evironmentally friendly. The electrolysis of NaCl solution has a principle of turning electrical into chemical energy in the form of hydrogen gas. Several factors that influence the efficiency energy of this conversion is the raw material, electrode geometry, solution concentration, solution flow pattern, and electron transfer on the surface. To ensure maximum surface reaction, the type of flow used is continuous electrolysis. Several variations made in this research include concentration of 1M and 2M, mesh sizes of 30; 40; 60; 80; and 100, and electric current variations at 3A and 5A. The electrodes utilized are made of Stainless Steel (SS316) wrapped to form a circular electrode. The results indicates that the flow rate of hydrogen is highest at 2 layers of mesh reaching up to 40mL/s compared to 1 layer of mesh at only 35mL/s. The highest energy efficiency is obtained at 60 mesh (35,7%), followed by mesh 80 (29,8%). At 100 mesh, there is a decline of energy efficiency (27,9%). This is due to the formation of Fe which deposits at the active surface of the electrode."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kezia Sherlita
"Perlindungan pada sistem tenaga listrik harus dirancang untuk memenuhi prinsip kehandalan, selektivitas, dan prinsip kestabilan, yang dapat dicapai melalui zonasi dan koordinasi proteksi. Dalam hal deteksi dan koordinasi proteksi gangguan tanah, sistem harus mempertimbangkan alokasi pentanahan dan kesesuaian hubungan, seperti pentanahan solid atau impedansi. Oleh karena itu, pemilihan lokasi dan koneksi pentanahan yang tidak tepat dapat menyebabkan gangguan yang tidak diinginkan dan kegagalan yang bertingkat. Studi ini menyajikan desain korektif untuk deteksi dan koordinasi proteksi gangguan hubung singkat satu fasa ke tanah. Sistem pentanahan dievaluasi dengan menggunakan rangkaian urutan nol untuk memperkirakan gangguan yang dapat terjadi pada sistem. Implementasi dari Standar IEEE 142-2007 digunakan untuk menyediakan sistem yang terhubung secara efektif, yang menghasilkan lokasi dan koneksi yang sesuai untuk pentanahan. Simulasi dilakukan dengan menggunakan perangkat lunak analisis sistem tenaga untuk membandingkan kinerja sebelum dan setelah desain korektif yang diusulkan. Hasilnya menunjukkan bahwa desain yang diusulkan dapat mengoreksi kesalahan operasi proteksi kesalahan tanah.
......Power system protection must be designed to meet the reliability, selectivity, and stability principle, which can be achieved through zoning and coordination. In the case of ground fault protection detection and coordination, the appropriate grounding allocation and connection, i.e. solid or impedance, shall be considered throughout the system. Hence, inaccurate selection for grounding location and connection may lead to undesirable disturbances and cascaded failure. This paper presents a corrective design for ground fault protection detection and coordination in an actual 34.5 kV power system network which has faced several misoperation of the ground fault protection. For this, the system’s grounding is assessed by using zero sequence network and the issues are summarized. The implementation of IEEE 142-2007 Standard is utilized to provide an effectively grounded system, resulting in the suitable location and connection for the grounding. The simulation is carried out by using power system analysis software to compare the performances before and after the proposed corrective design. The results shows that the proposed design can solve the misoperation of the ground fault protection."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Riches, B.E.
Bristol: ESM, 1989
621.319 2 RIC e
Buku Teks  Universitas Indonesia Library