Ditemukan 4 dokumen yang sesuai dengan query
cover
"The book provides a detailed, up-to-date account of the basics, the technology, and the clinical use of ion beams for radiation therapy. Theoretical background, technical components, and patient treatment schemes are delineated by the leading experts that helped to develop this field from a research niche to its current highly sophisticated and powerful clinical treatment level used to the benefit of cancer patients worldwide. This book consists of related chapters. It is a common achievement by 76 experts from around the world. Their expertise reflects the diversity of the field with radiation therapy, medical and accelerator physics, radiobiology, computer science, engineering, and health economics. The book addresses a similarly broad audience ranging from professionals that need to know more about this novel treatment modality or consider to enter the field of ion beam therapy as a researcher. However, it is also written for the interested public and for patients who might want to learn about this treatment option."
Berlin : Springer, 2012
e20425204
eBooks  Universitas Indonesia Library
cover
Risayanti
"Telah dilakukan pengukuran PDD, faktor keluaran dan profil dosis pada lapangan kecil dengan teknik penyinaran setengah lapangan menggunakan Film Gafchromic EBT3, bilik ionisasi Exradin A16, dan detektor matriks PTW 2D-Array 729. Tujuan dari penelitian ini adalah mengetahui karakteristik berkas foton lapangan kecil menggunakan teknik penyinaran setengah lapangan, dan membandingkan hasil pengukuran dengan data referensi yang menggunakan teknik penyinaran lapangan penuh full-beam . Evaluasi pengukuran PDD dilakukan dengan menentukan nilai dmax dan menghitung nilai TPR20,10. Profil dosis dianalisa berdasarkan nilai FWHM dan penumbra. Hasil pengukuran menunjukkan bahwa nilai dmax, TPR20,10, FWHM, penumbra, dan faktor keluaran menghasilkan pola yang sama dengan hasil pengukuran teknik penyinaran lapangan penuh full-beam . Deviasi FWHM terbesar menggunakana Film Gafchromic EBT3 dan Exradin A16 adalah -10.99 dan -33.14 terjadi saat pengukuran pada luas lapangan 0.8 0.8 cm2 dan kedalaman 1.5 cm, sedangkan deviasi FWHM terbesar menggunakan detektor matriks PTW 2D-Array 729 adalah -46.25 terjadi saat pengukuran pada luas lapangan 1.6 1.6 cm2 dan kedalaman 1.5 cm. Persentase deviasi faktor keluaran terbesar adalah -54.22 yaitu saat pengukuran menggunakan detektor matriks PTW 2D-Array 729 pada kondisi pengukuran luas lapangan 0.8 0.8 cm2 dan kedalaman 10 cm.

PDD measurements, output factor, and dose profile have been conducted in small field with half beam irradiation technique using Gafchromic EBT3 Film, Exradin A16 ionization chamber, and PTW 2D Array 729 matrix detector. This study was aimed to determine the characteristic of small field photon beam using half beam irradiation technique and compare the measurement results with reference data that performed full beam irradiation technique. PDD measurements evaluation has been done by determining the value of dmax and calculate the TPR20,10 value. Dose profile was analyzed based on the value of FWHM and penumbra. The measurement results showed that the value of dmax, TPR20,10, FWHM, penumbra, and output factor have similar pattern with the measurement results of full beam irradiation technique. The highest FWHM deviation value that can be obtained using Gafchromic EBT3 Film and Exradin A16 are 10.99 and 33.14 occurred when measurements were conducted in the field size of 0.8 0.8 cm2 and depth of 1.5 cm. The highest deviation percentage of output factor that can be obtained using PTW 2D Array 729 matrix detector is 54.22 occured in the field size of 0.8 0.8 cm2 and depth of 10 cm.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2016
S66624
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fitriyani
"Treatment Planning System (TPS) merupakan kunci dalam keberhasilan pengobatan radioterapi eksternal, yang secara langsung berdampak pada kualitas rencana perawatan dan ketepatan perhitungan dosis dalam perencanaan. Keluaran dari hasil perencanaan pada TPS berupa kurva DVH. DVH menjadi acuan dalam melihat penyebaran dosis pada target maupun organ sehat. Dalam penelitian ini, dilakukan perbandingan antara DVH hasil dari TPS dengan DVH hasil dari perhitungan analitik. Perbandingan DVH dilakukan dengan langkah awal membuat objek simulasi berupa fantom virtual menggunakan program Matlab dengan berbagai bentuk geometri, yaitu bola, kubus, dan silinder. Perencanaan terhadap objek simulasi dilakukan dengan menggunakan TPS Eclispe. Dari hasil perencanaan dengan menggunakan TPS Eclispe dan hasil perhitungan analitik, diperoleh perbedaan nilai tertinggi terdapat pada objek simulasi kubus untuk penyinaran 1 lapangan, dan pada objek simulasi silinder pada penyinaran 4 lapangan. Sementara pada perbandingan nilai Dmaks dan Dmin, perbedaan terbesar terdapat pada nilai Dmin dengan penyimpangan tertinggi berada pada objek simulasi kubus dan silinder. Tidak terdapat nilai yang sama pada perencanaan ini untuk semua objek simulasi.

Treatment Planning System (TPS) is the key to success of external radiotherapy treatment, which directly impacts the quality of treatment planning and the accuracy of dose calculation in planning. The output of the planning results at the TPS consists of the DVH curve. DVH is the target in looking at the distribution of doses to target and organ at risk. In this study, an experiment was conducted between DVH results from TPS and DVH results from analytical calculation. DVH comparison is done with the initial step of making simulation objects using virtual phantoms using the Matlab program with various geometric shapes, namely are sphere, cube, and cylinder. Planning of the simulation object is done using Eclispe TPS. From the results of planning using TPS Eclispe and analytical calculation results, the value of the assessment of the cube simulation object is obtained for 1 field illumination, and for cylinder simulation objects in 4 fields irradiation. While in determining the value of Dmax and Dmin, the biggest difference is the value of Dmin with the highest deviation in the comparison object of the cube and the cylinder. There are no equal values in this plan for all simulation objects."
Depok: Universitas Indonesia, 2019
T55297
UI - Tesis Membership  Universitas Indonesia Library
cover
Evi Pratiwi
"Linac Elekta Versa HD memiliki mode khusus pada berkas elektron energi 6 dan 10 MeV yang disebut mode High Dose Rate Electron (HDRE). Berkas elektron mode HDRE dapat menghasilkan dosis serap sepuluh kali lebih besar dari mode standar pada energi yang sama. Pada penelitian ini dilakukan pengukuran dosis serap ke air pada berkas elektron mode standar dan HDRE menggunakan protokol modifikasi kalibrasi dan protokol kalibrasi yang sudah banyak digunakan di seluruh dunia yaitu International Atomic Energy Agency Technical Report Series 398 (TRS-398) dan American Association of Physics in Medicine Task Group 51 (TG-51). Pada Institusi 1 digunakan detektor ionisasi silinder PTW 30013 dan detektor ionisasi plane-parallel PTW Roos yang dihubungkan dengan elektrometer PTW Unidos Romeo. Pada Institusi 2 digunakan detektor ionisasi silinder IBA FC65P, IBA CC13 dan detektor ionisasi plane-parallel IBA PPC40 yang dihubungkan dengan elektrometer IBA Dose 1. Modifikasi kalibrasi menggunakan detektor ionisasi silinder dan plane-parallel menggunakan faktor konversi kualitas berkas dari hasil perhitungan menggunakan Monte Carlo. Pada Institusi 1 (PTW 30013 dan PTW Roos), faktor koreksi ion rekombinasi pada mode HDRE lebih besar dibandingakan mode standar dengan diskrepansi 5,00 – 5,33% dan 4,52 – 5,06% sedangkan pada Institusi 2 (IBA FC65P, IBA CC13 dan IBA PPC40) secara berturut-turut memiliki diskrepansi 3,22 – 3,51%, 2,88 – 3,04% dan 0,77 – 0,87%. Faktor konversi kualitas berkas pada penelitian ini menunjukan nilai yang seragam yaitu > 1,00. Pada Institusi 1 (PTW 30013 dan PTW Roos) nilai rasio dosis antara modifikasi kalibrasi dan IAEA TRS-398 memperoleh nilai rasio dosis minimum pada 1,006 dan 1,000 sedangkan rasio dosis maksimum 1,019 dan 1,023. Institusi 2 (IBA FC65P, IBA CC13 dan IBA PPC40) memperoleh nilai rasio dosis minimum pada 1,009, 1,002 dan 1,010 sedangkan rasio dosis maksimum pada 1,023, 1,009 dan 1,030. Pada Institusi 1 rasio dosis antara modifikasi kalibrasi dan AAPM TG-51 memperoleh rasio dosis minimum pada 1,011 dan 0,994 sedangkan rasio dosis maksimum pada 1,016 dan 1,015. Pada Institusi 2 memperoleh rasio dosis minimum pada 1,000, 0,995 dan 1,003 sedangkan rasio dosis maksimum pada 1,008, 1,000 dan 1,022.

Elekta Versa HD linear accelerator has a special mode for electron beam of 6 and 10 MeV called High Dose Rate Electron (HDRE) mode. HDRE mode electron beam could generate an absorbed dose ten times greater than the standard mode electron beam at the same energy. In this study, electron beam output calibration will be measured in standard and HDRE mode using modified calibration protocol compared to calibration protocol widely used throughout the world, International Atomic Energy Agency Technical Report Series 398 (TRS-398) and American Association of Physics in Medicine Task Group 51 (TG-51). This study was performed using Elekta Versa HD Linear Accelerator electron beams with energies 6 and 10 MeV with standard and HDRE mode. Center 1 used PTW 30013 and PTW Roos connected to a PTW Unidos Romeo electrometer. Center 2 used IBA FC65P, IBA CC13 and IBA PPC40 connected to IBA Dose 1 electrometer. The modified calibration using cylindrical and plane-parallel chambers with updated based on Monte Carlo calculations. The dose ratio of the modified calibration, TRS-398 and TG-51 were comparing at the dose at the maximum depth. The recombination ion correction factor in HDRE mode is greater than standard mode in Center 1 (PTW 30013 and PTW Roos) have a discrepancy 5,00 – 5,33% and 4,52 – 5,06%, respectively. Center 2 (IBA FC65P, IBA CC13 and IBA PPC40) have a discrepancy 3,22 – 3,51%, 2,88 – 2,04% and 0,77 – 0,87%, respectively. Beam quality conversion factor in the modified calibration is a function of . The result of calculating the beam quality conversion factor for modified calibration in this study produced uniform value of > 1.00. The dose ratio between modified and TRS-398 protocol at Center 1 on PTW 30013 and PTW Roos has a minimum dose ratio at 1,006 and 1,000 and a maximum dose ratio at 1,019 and 1,023. Meanwhile, Center 2 on IBA FC65P, IBA CC13 and IBA PPC40 has a minimum dose ratio at 1,009, 1,002 and 1,010 and maximum dose ratio at 1,023, 1,009 and 1,030. The result of the dose ratio between the modified calibration and TG-51 protocols at Center 1 on PTW 30013 and PTW Roos has a minimum dose ratio at 1,011 and 0,994 and a maximum dose ratio at 1,016 and 1,015. Center 2 provided the result on IBA FC65P, IBA CC13 and IBA PPC40 has a minimum dose ratio at 1,000, 0,995 and 1,003 and a maximum dose ratio at 1,008, 1,000 and 1,022."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
T-pdf
UI - Tesis Membership  Universitas Indonesia Library