Aditya Tri Oktaviana
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
T52314
UI - Tesis Membership Universitas Indonesia Library
Dimas Aria Shufyananda
"Saat ini, komputasi tomografi (computed tomography/CT) sinar-X sudah banyak diterapkan di industri manufaktur untuk menguji atau memeriksa struktur internal suatu sampel. Metode Filtered Back Projecrtion (FBP) merupakan metode rekonstruksi citra CT yang popular digunakan untuk menghasilkan citra yang mempunyai noise lebih sedikit, kontras yang tajam dan mampu membedakan densitas antara latar belakang dan objek. Pemindaian citra digunakan mode geometri cone beam dengan rentang sudut 360° dan inkremen sudut 1°. Proses dimulai dari denoising, normalisasi, sintesis sinogram, dan rekonstruksi citra menggunakan FBP. Hasil dari penelitian ini adalah citra 2 dimensi hasil dari pemindaian citra geometri cone beam, sinogram dan hasil rekonstruksi citra irisan dengan parameter evaluasi yaitu Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), dan kontras relatif. Untuk mencari parameter evaluasi tersebut digunakan input koordinat Region of Interest (RoI). Diperoleh filter Cosine paling baik dalam memberikan nilai SNR, CNR dan kontras relatif paling tinggi. Dalam post processing akan digunakan variasi filter low pass (Ideal, Butterworth dan Gaussian). Input citra hasil rekonstruksi FBP menggunakan filter Cosine. Terdapat parameter evaluasi tambahan yaitu SSIM (Structural Similarity Index Measure). Beberapa parameter input seperti frekuensi cut-off, dan orde akan mempengaruhi frekuensi spasial. Frekuensi ini mengacu pada seberapa sering suatu gray value muncul atau berulang dalam citra.
Currently, X-ray computational tomography (CT) has been widely applied in the manufacturing industry to test or examine the internal structure of a sample. The Filtered Back Projection (FBP) method is a popular CT image reconstruction method used to produce images that have less noise, sharp contrast and are able to distinguish densities between the background and the object. Image scanning uses the cone beam geometry mode with an angle range of 360° and an angle increment of 1°. The process starts from denoising, normalizing, sinogram synthesis, and image reconstruction using FBP. The results of this study are 2-dimensional images resulting from scanning geometric cone beam images, sinograms and reconstructed sliced images with evaluation parameters namely Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), and relative contrast. To find the evaluation parameters, the Region of Interest (RoI) coordinate input is used. The Cosine filter is the best in providing the highest SNR, CNR and relative contrvalues. In post processing, variations of low pass filters (Ideal, Butterworth and Gaussian) will be used. Input the FBP reconstruction image using the Cosine filter. There is an additional evaluation parameter, namely SSIM (Structural Similarity Index Measure). Several input parameters such as cut-off frequency, and order will affect the spatial frequency. This frequency refers to how often a gray value appears or repeats in the image."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership Universitas Indonesia Library
Indah Lestariningsih
"Teknik akuisisi scan spiral memperkenalkan istilah Pitch. Pitch yang besar mempengaruhi proses rekonstruksi karena interpolasi data menjadi lebih lebar sehingga dapat menurunkan resolusi citra. Penelitian ini dilakukan dengan menggunakan fantom toraks in house yang dibuat dan didesain berdasarkan pengukuran data citra CT Toraks 100 pasien laki-laki. Parameter eksposi yang digunakan 130 kVp, rotasi tabung 0,6 detik, perubahan arus tabung 70 mAs dan 100 mAs serta variasi pitch mulai dari 0.5, 0.8, 1, 1.5, 1.8 dan 2. Fantom terbagi menjadi 4 bagian. Fantom bagian A untuk evaluasi akurasi posisi dan kualitas citra pada selang berisi media kontras, bagian B untuk evaluasi kualitas citra lubang udara hole , bagian C untuk evaluasi mikrokalsifikasi dengan variasi ukuran mesh pada serbuk tulang dan hidroxyapatite, dan bagian D untuk evaluasi MTF. Scanning fantom A untuk evaluasi akurasi posisi selang antara ukuran di fantom dengan monitor menunjukkan deviasi < 4 berjumlah 408 data 84 di sisi kanan dan 417 data 86 di sisi kiri dari total 486 data. Evalusi kualitas citra pada fantom A, terdapat perbedaan ?SNR pada tiap slice dengan hubungan yang linier terhadap perubahan pitch, semakin besar pitch yang digunakan ?SNR akan semakin lebar. ?SNR paling lebar terdapat pada slice ke-1 dan ke-2, selanjutnya pada slice ke-3 sampai ke-9 ?SNR stabil dan cenderung menurun. Evaluasi fantom B menunjukkan hole titik I dan J yang berdiameter 0.9 mm dan 0.625 mm tidak dapat tervisualisasi pada seluruh slice. SNR yang didapat paling tinggi pada hole tengah titik H dengan diameter 2 mm. Sensitivitas Pesawat CT dapat mendeteksi serbuk tulang ukuran mesh 10 dan 30 tetapi tidak dapat memperlihatkan serbuk tulang ukuran mesh 50 yang tersebar merata di permukaan fantom, ditunjukkan dengan nilai SNR tertinggi pada pitch 0.8 sebesar 2.659 SNR.
Acquisition technique in spiral scan introduce the term of Pitch. The big pitch could be influence for reconstruction process because interpolation will be wider, be affecting the spatial resolution. This study was performed by using in house thoracic phantom that made and designed based on image data measurement of CT Thorax of 100 men patient. Exposure Parameter which used was 130 kVp, tube rotation 0.6 second, tube current 70 mAs and 100 mAs, with pitch variation start from 0.5, 0.8, 1, 1.5, 1.8 and 2. Phantom was divided into 4 parts. Part A was used for evaluating the accuracy of position and image quality on a pipe that consist of contrast media, part B was used for evaluating image quality on hole, part C was used for evaluating micro calcification with various mesh size on bone material and hidroxyapatite, while part D was used for evaluating MTF. Phantom A scanning was performed for evaluating the accuracy of position between pipe in phantom and monitor showed deviation 4 with 408 number of data 84 on the right side and 417 data 86 on the left side from 486 all data. The result obtained for image evaluation, showed the different between delta SNR in every slice in phantom A with the pitch changing, used higher pitch becoming SNR wider. The widest SNR were occurred in the 1st and 2nd slice, furthermore in the 3rd until 9th slice SNR were stable and tend to decreased. Evaluation of phantom B showed that hole in point I and J which have diameter 0.9 mm and 0.625 mm could not visualized. The highest SNR was occurred in the middle hole point H with diameter 2 mm. The sensitivity of CT scanner is good enough to detect bone with the mesh size of 10 and 30 but not with the mesh size of 50 that spread in the phantom surface, this is shown with the highest SNR in the pitch 0.8 as 2.659 SNR."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T49787
UI - Tesis Membership Universitas Indonesia Library
Siti Nur Hidayati
"Penelitian ini menggunakan fantom abdomen in house dengan tujuan mengukur dosis di berbagai daerah organ yaitu hepar, ginjal, reproduksi dan bladder. Pengukuran dosis pada daerah organ dilakukandengan menggunakan dosimeter gafchromic dan TLD. Selain itu penelitian ini bertujuan untuk mengetahui profil dosis sepanjang sumbu-z dan image quality dengan variasi pitch factor. Faktor eksposi yang digunakan disesuaikan dengan aplikasi klinis abdomen yaitu 130 kV, 80 mAs, rotation 1.5 s dan delay 3 s. Pemilihan parameter pitch factor pada pemeriksaan CT abdomen akan mempengaruhi nilai dosis dan image quality. Variasi Pitch factor yang digunakan 0,8; 1 dan 1.5. Secara umum pengukuran dosis dengan gafchromic dan TLD di berbagai daerah organ memperlihatkan bahwa semakin besar penggunaan pitch factor maka dosis yang didapatkan semakin kecil. Profil dosis sepanjang sumbu-z berbentuk parabola yang simetris dengan dosis maksimum di sekitar 3.45 mGy dan dosis minimum pada awal dan akhir scanning sekitar 3.286 mGy. Hubungan nilai SNR dan slice untuk ketiga nilai pitch 0.8, 1 dan 1.5 pada umumnya sinusoidal dan untuk obyek di daerah kanan dan kiri menunjukkan kurva yang berbeda fase. Demikian juga antara dua titik atas dan bawah. Pengukuran kesesuaian antara citra obyek dengan ukuran obyek sebenarnya dari 512 data diperoleh hasil pada pitch factor 0.8 deviasi diameter 0 ndash; 5 sekitar 50.5 dan selebihnya 49.5 deviasinya diatas 5 . Pada pitch factor 1 deviasi 0 ndash; 5 sekitar 53.5 dan deviasi lebih dari 5 sekitar 46.7 , sedangkan untuk pitch factor 1.5 deviasi 0 ndash; 5 sekitar 68 dan deviasi lebih dari 5 sekitar 32.
This study uses in house phantom abdomen with the aim of measuring doses in different regions of the organ namely liver, kidney, reproduction and bladder. Measurement of dose in the organ region is done by using gafchromic and TLD dosimeter. In addition, this study aims to determine the profil dose along the z axis and image quality with variation of pitch factor. The exposure factors were adjusted for the clinical application of abdomen 130 kV, 80 mAs, rotation 1.5 and delay 3 s. Selection of pitch factor parameters on abdominal CT examination will affect the dose value and image quality. Variation of pitch factor used 0.8 1 and 1.5. In general, Measurements dose with gafchromic and TLD in different organ regions showed that the greater the use pitch factor the smaller the dose. Profil doses along the z axis are parabolic shapes symmetrical with maximum doses about 3.450 mGy and minimum doses at the start and end of scanning around 3.286 mGy. The relation of SNR and slice values to the three pitch values 0.8 1 and 1.5 is generally sinusoidal and for the object in the right and left regions show different curves of phase. Likewise between the two points above and below. Measurement of conformity between object image and actual object size from 512 data obtained result on pitch 0.8 deviation of 0 ndash 5 diameter around 50.5 and 49.5 deviation over 5 . In pitch factor 1 deviation 0 ndash 5 about 53.5 and deviation more than 5 about 46.7 , while for pitch factor 1.5 deviations 0 ndash 5 about 68 and deviation more than 5 about 32 ."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T49770
UI - Tesis Membership Universitas Indonesia Library