Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 8 dokumen yang sesuai dengan query
cover
Agus Purnomo
Depok: Fakultas Teknik Universitas Indonesia, 1994
S38580
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abstrak :
Study on carrageenan extraction using filter press with variation ratio of seaweed and extraction medium (water), temperature of precipitation, potassium chloride concentration has been conducted. Ratio of seaweed and water used were 1:20, 1:30 and 1:40 (w/v), temperature of precipitation were varied at 15 and 30°C, and potassium chloride concentration used were 1 and 1.5%. Parameters observed on the carrageenan were yield, viscosity, gel strength, moisture content, ash content, sulfate content and acid insoluble ash. Result showed that the best treatment was ratio seaweed : water = 1:20, temperature of precipitation at 30°C and potassium chloride concentration of 1%, with quality of carrageenan i.e. gel strength 1897.14 (g/cm2), viscosity 145 (cPs), ash content 29.59%, acid insoluble ash 0.83%, sulfate content 18.36%, yield 31.77% and moisture content 9.73%. The carrageenan quality has met with the standard established by Food Agriculture Organization (FAO), Food Chemical Codex (FCC) and European Economic Community (EEC).
620 JPBK 6:1 (2011)
Artikel Jurnal  Universitas Indonesia Library
cover
Abstrak :
The changes in stream water temperture help to identify the mechanism that generates the initil response .
2010
551 LIMNO 17:2 (2010)
Artikel Jurnal  Universitas Indonesia Library
cover
Irwan Kustianto
Abstrak :
Pemantauan temperatur air sangat penting dalam memahami perubahan lingkungan. Untuk itu, dibutuhkan perangkat yang dapat mendeteksi temperatur secara realtime dengan tingkat sensitivitas yang tinggi. Pada penelitian ini, dilakukan karakterisasi terhadap fiber Bragg grating (FBG) sebagai sensor berbasis optik untuk mengukur temperatur dalam rentang yang lebar, yaitu  4  hingga 50 . Hasil eksperimen skala laboratorium dengan air tawar menunjukkan bahwa  terdapat hubungan yang linear antara perubahan panjang gelombang dengan sensitivitas rata-rata 0,0103 , dengan error repeatibility dari 0,96%.  Selanjutnya, untuk mengantisipasi aplikasi pengukuran temperatur air di laut dilakukan simulasi untuk kondisi kedalaman 2000 . Hasil simulasi menunjukkan bahwa semakin tinggi tekanan hidrostatik akan berdampak terhadap bertambahnya peningkatan perubahan panjang gelombang Bragg. Selain itu dilakukan juga integrasi sensor temperatur FBG ini ke dalam sistem Internet of Things (IoT). Perancangan dimulai dengan pengolahan data yang didapat dari sensor temperatur FBG melalui optical interrogator, pembuatan database dan mengirimkannya ke dalam web server, di samping juga pembuatan website IoT dashboard yang berisi data-data yang didapat dari sensor temperatur FBG agar dapat dibaca secara online dan realtime. Dari hasil pengukuran quality of service website tersebut didapatkan nilai pengukuran throughput sebesar  0.73942412 , packet loss 0%, dan delay sebesar 1.3 . ......Monitoring water temperature is crucial in understanding environmental changes. For this purpose, a device capable of detecting temperature in real-time with high sensitivity is required. In this research, characterization of Fiber Bragg Grating (FBG) was conducted as an optical-based sensor to measure temperature over a wide range - from 4  to 50 . Laboratory-scale experiments with freshwater revealed a linear relationship between wavelength changes and an average sensitivity of 0.0103 , with a repeatability error of 0.96%. Furthermore, to anticipate the application of water temperature measurement in the sea, simulations were carried out for conditions at a depth of 2000 . The simulation results indicated that higher hydrostatic pressure impacts the increase in Bragg wavelength changes. In addition, integration of the FBG temperature sensor into the Internet of Things (IoT) system was also performed. The design began with processing data obtained from the FBG temperature sensor through an optical interrogator, creating a database, and sending it to a web server. This was complemented by the development of an IoT dashboard website displaying data from the FBG temperature sensor, accessible online and in real-time. The quality of Service measurements of this website showed a throughput value of 0.73942412 , 0% packet loss, and a delay of 1.3
Depok: Fakultas Teknik Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Paulus Nurdiatmoko
Abstrak :
Fungsi utama kondensor uap pada suatu instalasi pembangkit tenaga uap adalah untuk mengkondensasikan uap buangan dari turbin dan dengan demikian rnemulihkan air-umpan berkualitas-tinggi untuk dipakai Iagi dalam siklus. Jika air pendingin yang bersirkulasi cukup rendah, akan menimbulkan tekanan balik yang rendah untuk membuang uap keluar dari turbin. Hal ini akan menurunkan tekanan akhir yang keluar dari turbin sehingga daya turbin akan menjadi lebih besar dibandingkan dengan instalasi yang tidak meggunakan kondensor. Atau dengan daya turbin yang tetap, efisiensi instalsi akan meningkat. Kondensor uap yang merupakan alat penukar kalor berpendingin air akan sangat dipengaruhi oleh kondisi air pendingin atau sirkulasi, baik suhu atau kebersihannya. Pada pembuatan tugas akhir ini akan diperhitungkan pengaruh dari variasi suhu air pendingin terhadap unjuk kerja kondensor. Perhitungan diambil berdasarkan data-data yang didapat dari PLTU Muara Karang unit 3. Hasil akhir dapat dilihat bahwa dengan sernakin tingginya suhu air pendingin, maka akan meningkatkan tekanan lcondensor, suhu saturasi kondensor, beda suhu rata-rata, koefisien perpindahan kalor total dan beban kalor konclensor. Dan dari sini akan mengakibatkan makin menurunnya efisiensi termal siklus.
Depok: Fakultas Teknik Universitas Indonesia, 2002
S37673
UI - Skripsi Membership  Universitas Indonesia Library
cover
Faradilla Maulina
Abstrak :
Operasional Reaktor Serba Guna (RSG) 30 MW di kawasan Puspitek, Serpong yang memungkinkan terjadinya pelepasan radionuklida yang akan mengkontaminasi sistem perairan, salah saatunya adalah Cesium-137. Biota laut mampu mengakumulasi zat radioaktif sehingga konsentrasinya pada tubuh biota menjadi berlipat dibandingkan konsentrasi zat radioaktif di lingkungan. Kontaminasi dapat terjadi melalui jalur internal (ingesti) maupun jalur eksternal (radiasi lingkungan). Didukung oleh hal tersebut maka dilakukan studi bioakumulasi 137Cs oleh ikan kerong-kerong (Therapon jarbua) dari perairan Teluk Jakarta melalui jalur air laut. Penelitian ini bertujuan untuk mempelajari mekanisme bioakumulasi 137Cs dengan faktor pengaruh salinitas dan suhu air pada T. jarbua dengan menggunakan metode biokinetika kompartemen tunggal melalui tiga tahap percobaan yaitu, aklimatisasi, kontaminasi dan depurasi serta dilakukan pengukuran aktivitas 137Cs dengan spektrometer gamma HPGE. Hasil penelitian menunjukkan Nilai faktor biokonsentrasi (BCF) pada salinitas 26?; 29?; 32?; dan 35? berturut-turut adalah 2.22; 2.14; 1.56; dan 6.17 mL g-1, sedangkan nilai BCF pada suhu 28˚C; 31 ˚C;34 ˚C; dan 37 ˚C berturut-turut adalah sebesar 2.78; 3.25; 3.79; dan 3.51 mL g-1. ......The 30MW-Serba Guna Reactors (RSG) in puspitek ,Serpong may allow the release of the radionuclides that would contaminate the water system, one of them, is Caesium-137. Marine organisms are capable of accumulating the radioactive substances, resulting a higher concentration of it inside their body in contrast to the environment. Contamination can occur through internal pathways (ingestion) or external pathway (radiation in the environment). Supported by these statement, the 137Cs bioaccumulation study was performed by observing Target Fish (Therapon jarbua) from the Jakarta Bay. This research is intended to study the bioaccumulation's mechanism of 137Cs with the influence of salinity and water temperature on T. jarbua using a single-compartment biokinetic model by doing three experimental processes, namely acclimatization, contamination, and depuration. The activity of 137Cs was measured by High-purity Germanium (HPGE) gamma spectrometer. The results shows the values of bioconcentration factor (BCF) on T. jarbua at 26 ?; 29 ?; 32 ?; and 35 ? salinity, which are 2.22; 2.14; 1.56; and 6.17 mL g-1, respectively. On the other hand, the BCF values at 28°C; 31 °C; 34 ° C; and 37 ° C temperature are 2.78; 3.25; 3.79; and 3.51 mL g-1, respectively.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2016
S64449
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dito Tunjung Parahyta
Abstrak :
Proses Thermal Mixing adalah jenis dari proses pencampuran yang penting di berbagai industri, seperti industri pangan, pupuk, farmasi, material sampai petrochemical. Proses Thermal Mixing merupakan proses Multi input multi ouput (MIMO), karena bekerja dengan mengendalikan dua flow air panas dan air dingin untuk mengendalikan temperatur dan level campuran. Meskipun memiliki respon yang kurang baik untuk mengendalikan MIMO, namun PID masih banyak digunakan karena kesederhanaannya. Algoritma non konvensional yang lebih baik seperti fuzzy control memiliki kerumitan yang tinggi dibanding PID. Algoritma Adaptive Fuzzy PID Controller (AFPIDC) merupakan gabungan dari keduanya, memiliki basis PID yang cukup sederhana namun ditambahkan aspek Fuzzy untuk mempercepat pengendalian dengan cara mengubah konstanta PID secara real-time (on the fly). Algoritma AFPIDC ini diterapkan pada simulasi sistem pengendalian temperatur dan level air pada proses water Thermal Mixing dan dilakukan pada program MATLAB/SIMULINK di PC. Fuzzy yang digunakan memiliki dua input berupa error dan perubahan error, dan memiliki tiga output berupa perubahan nilai konstanta PID. Pengujian sistem dilakukan dengan simulasi perubahan setpoint dan gangguan berupa kebocoran flow. Dari hasil pengujian sistem, pengendali AFPIDC memiliki performa yang lebih baik dari PID dalam mengendalikan temperatur dan level pada sistem. Dalam pengendalian temperatur, didapatkan nilai settling time PID sebesar 830 detik, AFPIDC sebesar 328 detik dan untuk nilai overshoot PID 6,3% dan AFPIDC 0%. Untuk pengendalian level didapatkan settling time PID 3221 detik dan AFPIDC 235 detik dengan nilai overshoot PID 10,5% dan AFPIDC 0%. Dari pengujian sistem terhadap gangguan kebocoran, pengendali temperatur membutuhkan waktu untuk kembali stabil pada PID 780 detik, AFPIDC 250 detik. Sedangkan untuk pengendalian level untuk kembali stabil membutuhkan waktu PID 4510 detik, AFPIDC 225 detik.
The Thermal Mixing Process is a type of mixing process that is important in various industries, such as the food, fertilizer, pharmaceutical, material to petrochemical industries. The Thermal Mixing Process is a multiple-input multiple-output process (MIMO), because it works by controlling hot water and cold-water flows to control the temperature and level of the mixture. Although it has a poor response to control MIMO system, PID is still widely used because of its simplicity. There are some better control algorithm, such as fuzzy control, but have higher complexity than PID. The Adaptive Fuzzy PID Control (AFPIDC) algorithm is a combination of the two, has a simple PID basis with added Fuzzy aspects to speed up control by changing the PID constant in realtime. The AFPIDC algorithm is applied to the simulation of temperature and water level control systems in the process of water Thermal Mixing and is done on the MATLAB/SIMULINK program on a PC. The fuzzy algorithm uses two inputs in the form of errors and changes in errors and has three outputs in the form of changes in the value of the PID constant. System testing is done by simulating setpoint changes and disruption in the form of leakage flow. From the results of system testing, AFPIDC controllers have better performance than PID in controlling temperature and level in the system. In temperature control, the PID settling time is 830 seconds, AFPIDC is 328 seconds and the PID overshoot is 6,3% and AFPIDC is 0%. In level control, the settling time of PID is 3221 seconds while AFPIDC is 235 seconds with PID overshoot is 10,5% while AFPIDC 0%. From testing the system with leakage disturbance, the temperature controller needs time to regain stability at PID 780 seconds, AFPIDC 250 seconds. Meanwhile the level controlling stabilizes at PID 4510 seconds, and AFPIDC at 225 seconds.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Bambang Suryawan
Abstrak :
There are some parameters that identify the quantity of air i.e. dry bulb temperature, wet bulb temperature, humidity ratio, relative humidity, and dew point temperature. These parameters can be used to construct a new formula in order to determine the effectiveness of air processing equipment When air passes through an evaporative pad its dry bulb temperature will decrease. it can be lowered to 5°C, when its wet bulb temperature is maintained constant. Due to the air temperature is higher than the water temperature, so then the heat will flow from the air to water. U' the temperature of flow air assumed remain constant, this hear is to be used to evaporate the water drops. So, it is caused increasing of the air humidity ratio. This research found out that the humidity ratio increased until 2. 22-gram water/ kg dry air.
Depok: Fakultas Teknik Universitas Indonesia, 2001
JUTE-15-2-Jun2001-166
Artikel Jurnal  Universitas Indonesia Library