Ditemukan 8 dokumen yang sesuai dengan query
cover
Tarigan, Akor
Abstrak :
Rancang bangun pengendali temperatur pada chamber simulasi Inkubator bayi yang diajukan pada tugas akhir ini adalah sistim pengendali menggunakan komponen Rele sebagai penggerak akhir untuk heater dan komponen elektronik untuk mengontrol bekerjanya rele tersebut,dan Sensor temperatur digunakan NTC (Negative Temperature Coeficient). Stabilitas temperatur pada chamber simulasi dapat diperoleh sesuai dengan besaran setpoint Dengan menggunakan blower sebagai sirkulasi panas akan diperoleh respon time cepat pada temperatur yang dinginkan. Harga konduktivitas panas dengan menggunakan blower lebih baik dibandingkan tanpa blower, dimana : Dengan blower = 10 menit ; H = 30.6 (w/cmzoC) Tanpa blower = 16 menit ; H = 19.15(w/cm*’C) Sebagai chamber simulasi dibuat dari pelat dan acrylic berukuran P = 29 Cm,L = 11 Cm, T = 16 Cm dan element pemanas berupa lampu pijar 220 Volt 100 watt serta sebuah blower 12Vdc/4w.
Depok: Fakultas Teknik Universitas Indonesia, 1996
S38870
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arika Dhia
Abstrak :
Naskah ini melapokan hasil rancang bangun perangkat pemantau respirasi untuk aplikasi inkubator bayi. Perangkat pemantau respirasi menggunakan sensor serat optik yang diintegrasikan pada kain lentur. Sensor bekerja dengan memanfaatkan perubahan rugi-rugi intensitas cahaya yang terjadi jika lengkungan serat optik berubah seiring dengan ekspansi rongga dada saat proses pernapasan. Daya keluaran serat optik dimasukkan ke rangkaian elektronika pendukung untuk selanjutnya diolah agar tingkat respirasi napas per menit dapat ditampilkan secara real-time pada LCD.Berdasarkan hasil pengujian yang dilakukan, ditunjukkan bahwa sistem mampu mengukur tingkat pernapasan dari rentang 10 hingga 130 napas per menit, dengan galat error 0.006 dan nilai hysteresis 0.2 .
This text reports the result of respiratory monitor design for infant incubator application. Respiratory monitor uses fiber optic sensor which is intergrated into supple fabric. Sensor utilizes light intensity losses difference that changes as thorax expansion during respiration. The fiber optic rsquo s output then goes to the supporting electronic circuits to be processed in Arduino Uno R3 so real time respiration rate the number of breath per minute can be presented on LCD.The result shows that the system is capable to measure respiratory rate in the range of 10 to 130 breath per minute with 0.00595 error and 0.2 hysteresis error.
Depok: Fakultas Teknik Universitas Indonesia, 2017
S68691
UI - Skripsi Membership  Universitas Indonesia Library
cover
Putri Fadhillah Nugraha
Abstrak :
ABSTRAK
Menurut data dari World Health Organization WHO , Indonesia merupakan salah satu negara dengan tingkat kelahiran prematur tertinggi di dunia, dengan jumlah bayi yang terlahir prematur sebanyak 675.744 di tahun 2010, dan inkubator bayi menjadi salah satu cara untuk menyalamatkan mereka. Namun, distribusi listrik yang tidak merata di beberapa daerah terpencil merupakan kendala dalam penggunaannya di Indonesia, sehingga inkubator bayi non-elektrik diperlukan.Penggunaan Phase Change Material PCM tipe Beeswax sebagai elemen pemanas inkubator bayi non-elektrik telah menghasilkan bukti bahwa inkubator bayi tidak harus selalu bergantung pada listrik. Penelitian ini bertujuan untuk mendapatkan desain baru dari inkubator menggunakan energi PCM yang lebih efisien daripada inkubator dalam dua penelitian sebelumnya dengan mengatur perpindahan panas di dalamnya dan melakukan perubahan pada bahan inkubator dari kayu menjadi polyurethane serta cartridge PCM dari tembaga menjadi stainless steel yang membuat berat keseluruhan inkubator menjadi jauh lebih ringan.Variasi eksperimen dibagi menjadi waktu siang dan malam hari , penempatan cartridge PCM saat cartridge PCM ditempatkan secara sejajar atau tegak lurus terhadap lubang sirkulasi udara , dan bentuk lubang sirkulasi udara lubang lingkaran kecil dan lubang persegi panjang . Prototipe Inkubator Grashof tipe F yang telah dimodifikasi digunakan di sini dengan penambahan katup di dalamnya dan penerapan proses konveksi alami. Dari hasil percobaan, dapat disimpulkan bahwa Beeswax dapat mempertahankan temperatur 32 C ndash; 36 C selama 108.8 menit di siang hari dan 119.5 menit di malam hari, serta inkubator bayi non-elektrik dapat bekerja secara lebih efisien karena beberapa modifikasi yang dilakukan.
ABSTRACT
According to the World Health Organization WHO data, Indonesia is one of the countries with the highest preterm birth rates in the world, with the amount of 675,744 babies born prematurely in 2010, and an infant incubator is one of the ways to save them. However, the uneven power distribution in some remote areas is the obstacle in its use in Indonesia, so that non electric infant incubator is required.The use of Phase Change Material PCM type Beeswax as a heating element in non electric infant incubator has produced the evidence that the infant incubator does not have to always depend on electricity. This experiment aims to obtain the new design of incubator using PCM energy which is more efficient than the incubator in the two previous researches by regulating the heat transfer in it and make the changes of material of incubator from wood to polyurethane as well as PCM cartridge from copper to stainless steel which makes the overall mass of incubator much lighter.The experiment variation was divided into time day and night time , PCM cartridge placement when PCM cartridges were in parallel and perpendicular to the holes of circulation , and shape of air circulation hole small circle holes and rectangular holes . The modified prototype of Grashof Incubator Type F was used here by adding the valve inside it and applying natural convection process. From the experiment result, it could be concluded that Beeswax could maintained a temperature of 32 C ndash 36 C for 108.8 minutes in day time and 119.5 minutes in night time, as well as non electric infant incubator could worked in more efficient way due to some modifications made.
2017
S66828
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rho Natta Matahari
Abstrak :
[Salah satu tantangan dalam meningkatkan standar kesehatan di Indonesia adalah masih tingginya angka kelahiran bayi prematur. Upaya penyelamatan bayi yang lahir prematur terhambat oleh beberapa faktor terutama faktor ekonomi yang disebabkan mahalnya biaya perawatan di ruang NICU rumah sakit. Selain itu, distribusi listrik yang belum merata menyebabkan sedikitnya rumah sakit yang menyediakan fasilitas inkubator terutama pada wilayah terpencil di Indonesia. Penggunaan Phase Change Materials dari kelompok organik sebagai elemen pemanas inkubator portable non-elektrik agar aman bagi pernafasan bayi dan mudah pendistribusiannya menjadi salah satu alternatif upaya penyelamatan bayi prematur yang lahir terutama diwilayah yang belum dialiri listrik nasional. Eksperimen ini bertujuan mendapatkan masa PCM yang paling efisien sesuai Standar Nasional Indonesia untuk mendapatkan rentang waktu dan temperatur paling ideal bagi bayi prematur. Juga pengurangan masa PCM akan meringankan bobot inkubator secara total serta mengurangi biaya. Eksperimen dilakukan menggunakan prototype Inkubator Grashof seri-F yang memanfaatkan fenomena konveksi natural dalam proses pemanasan ruang inkubator. Temperatur diukur menggunakan termokopel tipe K yang dihubungkan pada Modul NI9211. Grafik pengukuran digambarkan oleh perangkat lunak Labview 8.5 yang diinstal pada Personal Computer Unit. Hasil eksperimen menunjukkan masa PCM jenis Beeswax sebesar 3kg adalah yang paling efisien dalam penggunaan energi. Aplikasi fin juga membantu mempersingkat waktu tunggu sebelum penggunaan inkubator dan distribusi panas yang lebih merata dalam ruang inkubator. ......One of the challenges in improving health standards in Indonesia is a high number of neonatal birth. Government efforts to save neonatals hampered by several factors especially economic factors caused by high cost of neonatals care in NICU room at the hospital. Moreover, the uneven of electricity distribution cause least hospitals providing incubator facilities, especially for remote areas in Indonesia. The use of Phase Change Materials from the organic group as a heating element for portable non-electric incubator to be safe for the baby's breathing and easy distribution into an alternative rescue efforts, especially premature babies born in the region that has not been electrified nationwide. Experiments aimed at finding the most efficient mass of PCM based on Indonesian National Standard to get the ideal time and temperature range for premature babies. PCM mass reduction also will lighten the weight of the incubator in total as well as reduce costs. Experiments conducted using prototype Incubator Grashof-F series which utilizes natural convection phenomena in the process of incubator space heating. Temperatures were measured using a K-type thermocouple connected to the module NI9211. Measurement chart illustrated by Labview 8.5 software installed on the Personal Computer Unit. The experimental results indicate the mass of 3kg PCM types Beeswax is the most efficient in energy use. Applications fin also help shorten the waiting time before the use of incubators and more even heat distribution within the incubator.;One of the challenges in improving health standards in Indonesia is a high number of neonatal birth. Government efforts to save neonatals hampered by several factors especially economic factors caused by high cost of neonatals care in NICU room at the hospital. Moreover, the uneven of electricity distribution cause least hospitals providing incubator facilities, especially for remote areas in Indonesia. The use of Phase Change Materials from the organic group as a heating element for portable non-electric incubator to be safe for the baby's breathing and easy distribution into an alternative rescue efforts, especially premature babies born in the region that has not been electrified nationwide. Experiments aimed at finding the most efficient mass of PCM based on Indonesian National Standard to get the ideal time and temperature range for premature babies. PCM mass reduction also will lighten the weight of the incubator in total as well as reduce costs. Experiments conducted using prototype Incubator Grashof-F series which utilizes natural convection phenomena in the process of incubator space heating. Temperatures were measured using a K-type thermocouple connected to the module NI9211. Measurement chart illustrated by Labview 8.5 software installed on the Personal Computer Unit. The experimental results indicate the mass of 3kg PCM types Beeswax is the most efficient in energy use. Applications fin also help shorten the waiting time before the use of incubators and more even heat distribution within the incubator., One of the challenges in improving health standards in Indonesia is a high number of neonatal birth. Government efforts to save neonatals hampered by several factors especially economic factors caused by high cost of neonatals care in NICU room at the hospital. Moreover, the uneven of electricity distribution cause least hospitals providing incubator facilities, especially for remote areas in Indonesia. The use of Phase Change Materials from the organic group as a heating element for portable non-electric incubator to be safe for the baby's breathing and easy distribution into an alternative rescue efforts, especially premature babies born in the region that has not been electrified nationwide. Experiments aimed at finding the most efficient mass of PCM based on Indonesian National Standard to get the ideal time and temperature range for premature babies. PCM mass reduction also will lighten the weight of the incubator in total as well as reduce costs. Experiments conducted using prototype Incubator Grashof-F series which utilizes natural convection phenomena in the process of incubator space heating. Temperatures were measured using a K-type thermocouple connected to the module NI9211. Measurement chart illustrated by Labview 8.5 software installed on the Personal Computer Unit. The experimental results indicate the mass of 3kg PCM types Beeswax is the most efficient in energy use. Applications fin also help shorten the waiting time before the use of incubators and more even heat distribution within the incubator.]
Depok: Fakultas Teknik Universitas Indonesia, 2016
S61757
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arif Widianto
Abstrak :
Pada skripsi ini, dilakukan rancang bangun perangkat pengukur berat badan bayi untuk aplikasi inkubator. Perangkat bekerja dengan memanfaatkan load cell sebagai pendeteksi berat yang dipasang di bagian bawah alas tidur bayi. Keluaran load cell diolah dengan rangkaian elektronika pendukung untuk kemudian diproses oleh mikrokontroler Arduino Uno R3 dan ditampilkan pada LCD. Hasil pengujian menunjukkan bahwa perangkat mampu bekerja pada rentang berat 0 ndash; 3000 gram dengan threshold dan resolusi masing-masing sebesar 12,5 gram. Perangkat hasil rancang bangun telah dibandingkan dengan timbangan konvensional yang memiliki nilai galat error rata-rata sebesar 7,541 , sementara nilai galat error rata-rata yang dihasilkan perangkat memiliki nilai yang lebih rendah, yaitu 4,313 . Selain itu, perangkat menghasilkan hysteresis yang lebih rendah dibandingkan dengan hysteresis timbangan konvensional.
In this undergraduate thesis, design of weight monitoring system based on load cellfor newborn incubator application has been conducted. The system works by usinga load cell as a sensing element which is installed under a sleeping mats. The outputof load cell is processed by the support electronic circuit and then displayed onLCD by Arduino Uno R3 microcontroller. Experiment results show that the deviceis able to measure the body weight of the newborn from 0 up to 3000 gram. Thethreshold value is 12.5 gram and its resolution value is also 12.5 gram. Compared toconventional baby scale with error 7.541 this device has a lower error, 4.313 .It is also shown that the developed device has a lower hysteresis compared to theconventional baby scale.
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67435
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ketut Vanda Aryanthera Wisnu Nadia
Abstrak :
Masalah respirasi umum terjadi pada bayi prematur. Beberapa masalah respirasi yang dialami bayi prematur adalah kesulitan bernapas, penyakit paru-paru kronis, dan apnea. Apnea adalah kondisi ketika seseorang berhenti bernafas atau mengalami kesulitan menghirup udara melebihi 2 mL/kg. Penyakit ini dapat menyebabkan kerusakan pada organ lain atau kematian. Oleh karena itu, pemantauan pada proses respirasi diperlukan. Namun, pemantauan respirasi di rumah sakit Indonesia, sebagian besar dilakukan secara manual dalam jangka waktu tertentu. Dalam penelitian ini, dikembangkan rancang bangun perangkat pemantau respirasi berdasarkan refleksi cahaya untuk aplikasi inkubator bayi yang dapat beroperasi secara real-time. Perangkat ini terdiri dari sumber cahaya dengan panjanga gelombang 650 nm dan daya 5 mW, kertas reflektor, detektor, rangkaian pengkondisi sinyal, mikrokontroler Arduino UNO R3 dan juga buzzer untuk mengantisipasi situasi darurat, seperti apnea. Perangkat diuji dengan simulator yang dapat diatur secara manual dengan mengikuti aplikasi metronome. Berdasarkan hasil, ditunjukkan bahwa error sebesar 1,99, nilai ini masih di bawah batas maksimal error untuk peralatan medis, yaitu 5. Batas tersebut berdasarkan AAMI Association for Advancement of Medical Instrument.
Respiratory problems are common in premature infants. Some of the problems of respiration experienced by premature infants are difficulty breathing, chronic lung disease, and apnea. Apnea is a condition when a person stops breathing or have difficulty in breathing the air that exceeds 2 mL kg. This disease can cause damage to other organs or death. Therefore, monitoring the premature respiratory process is needed. But in Indonesia, respiration monitoring at health centers mostly is done manually in a certain period of time. In this research, we propose the design of respiration sensor based on laser reflection for infant incubator that can operate continuously. The device consists of a laser with wavelength 650 nm and power 5 mW, a paper reflector, detector, signal conditioning circuit, microcontroller Arduino UNO and also a buzzer for anticipating the emergency situation, such as apnea. The device is tested with a simulator that can be set manually by following the metronome application. Based on the results, it is shown that the error is 1.99, this value is still below the maximum limit error for medical equipment, which is 5. The limit is based on AAMI Association for Advancement of Medical Instruments.
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Farrel Mahardhika Fajar
Abstrak :
Kelahiran prematur merupakan masalah berkepanjangan yang berhubungan dengan risiko morbiditas dan mortalitas bayi. Sistem inkubator dikemukakan untuk meminimalkan risiko kelahiran prematur. Salah satu sistem otomasi yang digunakan pada inkubator adalah regulasi panas dan kelembaban. Regulasi panas dan kelembaban umumnya dikendalikan menggunakan sistem kendali feedback seperti PID dan fuzzy-logic PID. Material PTC adalah material yang biasa digunakan sebagai pemanas ruangan. Sistem kendali digunakan untuk mengendalikan pemanas PTC agar mencapai suhu yang diinginkan. Pada penelitian ini dilakukan empat jenis eksperimen untuk mengevaluasi performa PTC sebagai pemanas inkubator dengan PID dan fuzzy logic-PID sebagai sistem kendali. Pertama, dilakukan uji karakteristik hambatan PTC terhadap suhu. Selanjutnya, PTC dihubungkan dengan kipas dan digunakan sebagai pemanas inkubator untuk diuji performa material sebagai pemanas. Eksperimen ini meliputi uji step response untuk mengetahui parameter yang diperlukan untuk tuning PID. Parameter ini kemudian digunakan pada kendali PID. Ditambah itu, diberikan implementasi fuzzy-logic pada PID untuk mengevaluasi perbandingan performa pengendali dengan performa inkubator yang sudah ada. Hasil penelitian yang dilakukan menunjukkan bahwa pemanas PTC dapat memanaskan udara pada inkubator dan dapat dikendalikan menggunakan sistem kendali PID dan fuzzy-logic PID. Meski performa lebih buruk dibandingkan sebagian besar inkubator yang sudah ada, konsumsi daya PTC yang hanya membutuhkan 120 Watt bersifat lebih hemat dibandingkan inkubator eksisting yang menghabiskan daya 350 – 400 Watt. ......Premature birth is an everlasting problem that relates to the risk of morbidity and mortality of prematurely-birth infants. Incubator system was invented to minimize the risk. One of the automation systems that are used in incubator is heat and humidity regulation. This particular regulation system commonly uses feedback control system such as PID and fuzzy-logic PID. PTC material is the material commonly used as a room heater. In order to meet the desired temperature, control system is implemented to the PTC. This research evaluates the performance of PTC as incubator heater with PID and fuzzy logic-PID as the control system of choice. First, characteristic test is performed at the material to evaluate its heating performance. This test costists of step response test to determine parameters required to perform PID tuning. The obtained parameter is then calculated to determine the tuned PID parameter gains. After that, fuzzy logic is implemented to the system which controls those parameters based on the measured error and change of error. The result of both experiments are compared to existing incubators used in publications. The result of this comparison shows that PTC is capable of warming incubator to desired temperature and can be controlled with PID and fuzzy-logic PID. While the performance is inferior to majority of existing incubators, this tradeoff of more efficient power (120 Watt versus 350 – 400 Watt) can be considered as an alternative.
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Muhammad Hadiyan Faza
Abstrak :
ABSTRAK
Inkubator bayi adalah alat elektromedik yang berfungsi untuk memberikan kehangatan, kelembaban, dan oksigen dimana seluruh lingkungannya terkontrol dan diperlukan oleh bayi prematur. Supaya inkubator bayi berfungsi dengan benar, dibutuhkan pasokan listrik yang cukup supaya tercapai berat badan bayi yang ideal. Untuk beberapa desa-desa di Indonesia yang tidak terjangkau oleh sumber listrik konvensional atau listrik PLN akan menjadi bahaya untuk bayi prematur. Sehingga dikembangkan sistem catu daya inkubator bayi dengan sumber energi terbarukan berbasis arus searah. Beberapa keuntungan sumber listrik arus searah adalah efisisensi yang tinggi dimana transmisi arus searah bisa membawa daya lebih banyak dengan rugi-rugi listrik dalam jumlah yang kecil serta kehandalan yang tinggi. Penelitian ini membahas tentang tiga skenario studi sistem catu daya inkubator bayi. Hasil dari penelitian yang dilakukan pada skenario pertama untuk durasi ketahanan suplai baterai asam timbal untuk daya lampu 42 W mampu bertahan selama 504 menit dan untuk daya lampu 31 W mampu bertahan selama 721 menit. Pada skenario kedua untuk durasi ketahanan suplai baterai lithium-ion untuk daya lampu 42 W mampu bertahan selama 755 menit dan untuk daya lampu 31 W mampu bertahan selama 990 menit. Untuk skenario ketiga pada ketahanan suplai baterai lithium-ion untuk daya lampu 50 W mampu bertahan selama 625 menit.
ABSTRACT
Baby incubator is an electromedical device that give a warm, humidity, and oxygen where it rsquo s environment controlled and required by premature baby. For the proper usage on this device, it requires an enough supply of electric to reach an ideal weight for babies. It rsquo s a difficulty for some villages in Indonesia that are not covered by a conventional electricity. Then, developed a power supply system for baby incubator with renewable energy based on Direct Current. Several advantages of direct current usage are high efficiency, which it rsquo s transmission can carry more power with a small amount of electrical losses and high reliability. This research discusses about three scenarios of electrical system for baby incubator. The result of this research is for the first scenario using a lead acid battery on 42 W lamp can last for 504 minutes and on 31 W lamp can last for 721 minutes. At the second scenario using lithium ion battery on 42 W lamp can last for 755 minutes and on 31 W lamp can last for 990 minutes. And for the third scenario using lithium ion battery on 50 W lamp can last for 625 minutes.
2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library