Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Arif Zakaria Kapa
"Kajian perencanaan pembangkitan listrik tenaga gas (PLTG) di anjungan Krisna-P CNOOC SES Ltd, dilandasi pertimbangan terbuangnya raw associated gas (RAG). Disisi lain, CNOOC SES Ltd memiliki kontrak penjualan non associated gas ke PLN untuk PLTGU Cilegon. Sebagian non associated gas (gas ekonomis) juga dimanfaatkan sendiri oleh CNOOC SES Ltd untuk pembangkit listrik menggunakan generator turbin gas. Karena kebutuhan akan listrik yang cukup besar maka konsumsi gas untuk pembangkitan sendiri juga besar. Keadaan ini memberi peluang untuk menghemat penggunaan gas bilamana merencanakan pembangkitan listrik yang tidak mengkonsumsi gas ekonomis ini.
Kenyataan bahwa anjungan Krisna-P memiliki sambungan listrik dengan jala-jala kelistrikan CNOOC SES Ltd, memungkinkan perencanaan pembangkitan di anjungan Krisna-P memanfaatkan gas buang ini. Dengan masuknya suplai listrik dari anjungan Krisna-P, membuat penghematan gas ekonomis, sehingga mobilisasi gas ke PLN bisa lebih besar lagi dan memberi keuntungan kepada CNOOC SES Ltd. Dengan demikian kajian keekonomian perencanaan pembangkitan di Krisna-P perlu dilakukan, dengan membandingkan keuntungan ekonomis dari tambahan gas yang di jual ke PLN, karena penghematan ini terhadap biaya investasi yang di perlukan.

Study of planning of electrical power generation by gas resources at Krisna-P platform is based on consideration of raw associated gas (RAG) wasting. At the other side, CNOOC SES Ltd have contract of gas selling to PLN for Gas and Steam Power Generation (PLTGU) Cilegon. Some of non associated gas (economic gas) that being sold to PLN is also utilized by CNOOC SES Ltd for own power generation using gas turbine generators. Due to the high requirement of electrical power the gas consumption for own generation is also high. This condition give an opportunity to save the gas upon there is a plan to make power generation that is not consuming this economic gas.
The fact that Krisna-P platform has electrical connection to CNOOC SES Ltd grid give possibility to have planning for electrical power generation at Krisna-P that consuming this uneconomic gas. By this Krisna-P electrical supplying, there will save the economic gas, so that gas mobilization to PLN can be increased and give more advantage to CNOOC SES Ltd. Therefore, the economic study of power generation planning at Krisna-P platform need to conduct to compare the economic advantage of gas sell to PLN with the investment required.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
T42628
UI - Tesis Membership  Universitas Indonesia Library
cover
Satrya Alfandi, Author
"ABSTRAK
Hidrogen sulfida merupakan gas beracun yang terkandung pada instalasi
produksi associated gas suatu industri eksplorasi minyak dan gas. Skripsi ini
merupakan penelitian deskriptif dengan pendekatan semi kuantitatif menggunakan
data sekunder perusahaan dan literature serta observasi lapangan yang kemudian
dianalisis menggunakan perangkat lunak Areal Location Hazardous Atmosphere
(ALOHA). Tujuan penelitian ini adalah mengetahui konsekuensi yang terjadi
berdasarkan jangkauan dispersi gas, dan populasi berisiko terpajan dari skenario
kebocoran instalasi produksi associated gas yang sudah dirancang.
Hasil penelitian ini didapatkan bahwa skenario worst case (ruptur dan
tidak terkendali) pada pipa gas berukuran 10 inch memiliki dispers gas paling
luas. Dalam satu jam, dispersi gas H2S terjauh dengan AEGL-1 0.51 ppm (60
min) mencapai 3.6 km dengan populasi berisiko mencakup penduduk yang tinggal
di sekitar area station produksi PT. X. Selain itu didapatkan gambaran
pengetahuan populasi berisiko terpanajan mengenai bahaya kebocoran gas serta
gambaran sistem keselamatan kebocoran gas yang tersedia di PT.X

ABSTRACT
Hydrogen sulfide is a toxic gas that is contained on the installation of
associated gas production of an oil and gas exploration industry. This thesis is a
descriptive study with a semi-quantitative approach using secondary data from the
company, literature and field observations. Then, these data are analyzed using the
software Areal Location of Hazardous Atmosphere (ALOHA). The purpose of
this study was to determine the consequences that occur based on the range of gas
dispersion, and population at risk to exposed of leakage scenarios that have been
designed at the associated gas production installations.
The results of this study found that the worst case scenario (uncontrolled
rupture) in a 10 inches gas pipeline has the most extensive gas dispersion. Within
an hour, the farthest H2S gas dispersion with AEGL-1 0.51 ppm (60 min) reached
3.6 km with a population at risk include people living in the surrounding area of
production station. Moreover, other results from this study were the level of
knowledge from population at risk about the dangers from gas leaks and gas leaks
safety systems overview that available in PT.X."
Universitas Indonesia, 2014
S54963
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mohamad Agus Farhan
"Pertumbuhan associated gas flaring sebagai efek samping dari perkembangan fasilitas produksi minyak dan gas bumi menimbulkan pemasalahan perubahan iklim global akibat emisi CO2. Pengurangan associated gas flaring harus dilakukan dengan cara memanfaatkanya karena masih memiliki value dengan penerapan teknologi yang tepat. Thesis ini menyajikan analisis tekno-ekonomi pemanfaatan skala kecil terkait pembakaran gas terakumulasi dari platform stasiun terapung. Skema teknologi pemanfaatan yang diusulkan adalah pembangkit listrik, mini LNG, mini GTL dan sumur injeksi ulang gas. Metode analisa teknis menggunakan proses simulasi dan cashflow untuk analisa keekonomiannya.
Hasil simulasi menunjukkan bahwa skema pertama menghasilkan listrik 13 x 106 kWh/tahun dan skema kedua menyediakan 20 tpd produk LNG, dan skema ketiga menyediakan 80 bpd produk syncrude dan skema terakhir hanya terjadi peningkatan tekanan reservoir sekitar 3 bar. Hasil analisis ekonomi, pembangkit listrik membutuhkan CAPEX terendah dan memberikan IRR tertinggi yaitu 30,12% dengan NPV sebesar 4,2 juta USD. Skema pembangkit listrik ini menjadi teknologi yang paling optimal berdasarkan tekno-ekonomi untuk pemanfaatan pembakaran gas terkait skala kecil di platform stasiun terapung.

The accretion of associated gas flaring as a side effect oil and gas production facilities growth raise climate changes issue in global due to CO2 emissions. Reduction of associated gas flaring should be done because associated gas still have a value by applying the right technology. This paper presents techno-economics analysis of utilization small-scale associated gas flaring of flow station platform. The proposed technology utilization scheme is a power plant, mini LNG, mini GTL and gas re-injection wells. Technical analysis method uses the simulation process and cashflow for economic analysis.
The simulation results show that 1st scheme generates 13 x 106 kWh/year of electricity and 2nd rd scheme provides 80 bpd of syncrude products and the last scheme only generate reservoir pressure enhancement around 3 bar Economic analysis result, Power generation requires lowest CAPEX and provides highest IRR 30.12% with NPV 4.2 million USD. Power generation scheme become the most optimum technology based on techno-economic analysis for the small-scale associated gas flaring utilization in flow station platform.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
T53192
UI - Tesis Membership  Universitas Indonesia Library