Ditemukan 3 dokumen yang sesuai dengan query
cover
Irshadi Izhhar
"Kereta Rel Listrik (KRL) disuplai tegangan 1500 V DC oleh gardu traksi yang didalamnya terdapat komponen penyearah. Penyearah ini memproduksi harmonisa yang menyuntikkan arus menuju sumber tegangan menengah 20kV PLN dan dapat menyebabkan rusaknya peralatan listrik. Hasil pengukuran distorsi harmonisa pada kubikel 20kV/1.2kV gardu traksi menunjukkan THD maksimum tegangan sebesar 1.87 % dan THD arus maksimum sebesar 63.38 %. THD maksimum tegangan masih dibawah standar IEEE (<5%) sedangkan THD maksimum arus berada diatas standar IEEE (<20%). Untuk mengurangi efek distorsi harmonisa arus, dirancang filter pasif untuk memfilter harmonisa orde ke-5,ke-7, dan ke-11. Hasil simulasi dengan ETAP 7.0.0 didapatkan hasil rancangan filter pasif optimum dapat mengurangi THD arus hingga rata-rata 6.24%.

Electric train is supplied with 1500 V DC by traction substation which have components of the rectifier . This rectifier produces harmonics that inject harmonics current toward source 20kV PLN and cause the damage of electric utility. Measurement results of harmonic distortion at 20kV/1.2kV cubicles in traction substation shows that the maximum value of THD-v is 1.87% and the maximum value of THD-i is 63.38 %. THD-v is below IEEE standard (< 5 %) and THD-i is above the IEEE standard (<20 %). In order to reduce the effects of harmonics currents, passive filter is designed to filter harmonics for 5th , 7th , and 11th order. ETAP 7.0.0 simulation result obtains the optimum design of passive filter that can reduce THD-i to 6.24% average.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S57222
UI - Skripsi Membership  Universitas Indonesia Library
cover
Naufal Auliya
"Peralatan-peralatan elektronik dan eletkronika daya yang mayoritas merupakan beban non-linear dan berbasis sistem pensaklaran pada sebuah sistem data center menyebabkan permasalahan kualitas daya lisrik yaitu berupa distorsi harmonisa. Maka dari itu dilakukan penilitan ini yang bertujuan untuk mengidentifikasi fenomena harmonisa pada sistem data center yang terdapat Uninterruptible Power Supply (UPS) sebagai sumber dari harmonisa. Untuk melihat fenomena harmonisa yang terjadi dilakukan dengan simulasi perangkat lunak ETAP 12.6.0. Selanjutnya akan dilihat bagaimana besar dari %THD dan %IHD melalui grafik hasil analisa harmonisa load flow yang nantinya akan dibandingkan dengan standar besar harmonisa IEEE 519-1992. Lalu akan dirancangan sebuah single-tuned passive filter dalam rangka untuk mereduksi distorsi harmonisa dengan memvariasikan nilai dari quality factor sehingga didapatkan filter yang paling optimal dengan tingkat %THD-v berada dibawah 5%.

Electronic and power electronic equipments that most of them are non-linear loads and switching-based equipments on a system of data center electricity causing power quality problems in the form of harmonic distortion. Therefore by doing this research which aims to identify harmonic's phenomenon on data center which has Uninterruptible Power Supply (UPS) as the source of harmonics. To see harmonic phenomenon that occurs is investigated by doing simulation in ETAP 12.6.0. Furthermore, we will see the characteristic of %THD and %IHD through the results of harmonic load flow analysis that will be compared with harmonic standard of IEEE 519-1992. Then will be designed a single-tuned passive filter in order to reduce harmonic distortion by varying the value of the quality factor to obtain the most optimal filter with the value of %THD-v in all buses below 5%."
Depok: Fakultas Teknik Universitas Indonesia, 2016
S62928
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nareza Denanda Putra
"Harmonisa adalah permasalahan kualitas daya yang berupa distorsi terhadap gelombang tegangan dan arus akibat pemakaian beban non linier. Efek dari harmonisa sendiri dapat menyebabkan tidak efisiennya alat, dan merusak perangkat terutama pada alat-alat kedokteran yang memiliki harga yang cukup mahal. Pada penelitian ini akan dirancang filter harmonisa berdasarkan data hasil pengukuran setiap harinya. Urutan harmonisa dominan yang muncul setiap harinya adalah pada urutan ke-5, ke-7, dan ke-11. Lalu dirancang single-tuned passive filter untuk mereduksi distorsi harmonisa dengan beberapa variasi filter untuk mendapatkan filter yang paling optimal. Didapatkan penurunan presentase THD-i paling optimum pada jenis filter hari Sabtu dan dengan nilai IHD-I tiap fasanya yang sudah sesuai standar.

Harmonics is a power quality problem in the form of distortion to voltage and current waves due to non linear load usage. The effects of the harmonics themselves can lead to inefficient tools, and damage the device, especially in medical devices that have a fairly expensive price. In this research will be designed harmonic filter based on daily measurement data. The dominant harmonic sequence that appears each day is in the order of the 5th, 7th, and 11th. Then designed single tuned passive filter to reduce harmonic distortion with some filter variation to get the most optimal filter. The most optimum percentage reduction of THD i was observed on Saturday filter types and with IHD I values per standard phase."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67266
UI - Skripsi Membership  Universitas Indonesia Library