Muhammad Waliyyulhaq
"Penelitian ini bertujuan untuk membandingkan kualitas dari perencanaan terapi menggunakan conformity index (CI) dan homogeneity index (HI) pada kasus kanker paru-paru. Dengan menggunakan 5 pasien kanker paru-paru yang berada pada paru kanan. Dilakukan evaluasi pengaruh dari dose grid, kalibrasi densitas elektron berdasarkan fan beam dan cone beam CT.
Hasil dari penelitian ini menunjukkan pasien dengan volume target berukuran besar memiliki kecenderungan CI yang rendah dan HI yang tinggi. Pada penggunaan variasi grid dose, nilai CI dan HI masing-masing kurang dari 0.02 dan 0.013. Perbedaan perhitungan antara cone beam dan fan beam adalah 10% untuk CI dan 60% untuk HI.
This research aims to compare the quality of planning by using conformity index (CI) and homogeneity index (HI) for lung cancer cases. We used 5 lung cancer patients which is located in right lung. We evaluated the impact of dose grid, eletron density calibration based on fan beam and cone beam CT. The results of shows the patient with big size target volume has tendency low CI value and high HI. On the use of grid dose variation, the CI and HI values less than 0.02 dan 0.013, respectively. The differences between the cone beam and fan beam calculation was 10% for CI and 60% for HI."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
S62136
UI - Skripsi Membership Universitas Indonesia Library
Wahyu Edy Wibowo
"[Telah dilakukan penelitian dalam mengevaluasi pengaruh material homogen dan inhomogen pada teknik IMRT (Intensity Modulated Radiotherapy) menggunakan modalitas Fan Beam CT (FBCT) dan Cone Beam CT (CBCT) terhadap Gamma Index (GI). Perencanaan ulang dilakukan untuk 5 pasien kanker paru kanan pada modalitas FBCT dan CBCT menggunakan TPS Phillips Pinnacle energi foton 6 MV. Menggunakan Teknik IMRT 30 segmen, 50 segmen, dan 70 segmen untuk perencanan terapi. Calculation Grid Resolution (CGR) 0.2 cm dan 0.4 cm digunakan sebagai resolusi dalam perhitungan dosis. Serta kalibrasi bilangan CT (KBC) FBCT, CBCT, dan linear dipergunakan sebagai koreksi CT density number. Pengukuran plannar dose untuk evaluasi Gamma Index (DD 2% / DTA 2 mm, passing rate 90%) dilakukan pada SAD 100 cm dengan material homogen dan inhomogen pada kedalaman 1.5 cm, 5 cm, dan 10 cm. Didapatkan deviasi nilai rata-‐rata GI antara CGR 0.2 cm dengan 0.4 cm material homogen modalitas FBCT dan CBCT berturut-‐tutut ≤1.46% dan ≤ 1.13%. Serta deviasi pada material inhomogen sebesar ≤ 2.54% (FBCT) dan ≤ 1.74% (CBCT). Deviasi Nilai rata-rata GI antara FBCT dengan CBCT dengan CGR 0.2 cm berturut-turut ≤ 1.95% (homogen) dan ≤ 2.36% (inhomogen). Dan deviasi Nilai rata-‐rata GI antara material homogen dan material ekuivalen homogen sebesar ≤ 0.80%. Dari hasil penelitian yang didapat, bahwa evaluasi Gamma Index dapat dipengaruhi oleh jumlah segmen, modalitas CT, kalibrasi bilangan CT, Calculation Grid Resolution, dan kedalaman material.
These Studies have been carried out to evaluate the effect of a homogeneous and inhomogeneous material on IMRT Technique (Intensity Modulated Radiotherapy) using Fan Beam CT (FBCT) and Cone Beam CT (CBCT) for the Gamma Index (GI). The Phillips Pinnacle treatment plan was used to replan 5 patients on right side of lung cancer. Photon 6 MV was applied to this technique with 30 segments, 50 segments, and 70 segments, repectively. Using Calculation Grid Resolution (CGR) 0.2 cm and 0.4 cm for resolution in the calculation of the dose. As well as the calibration of CT numbers (CCN) FBCT, CBCT, and the linear density are used as a correction CT number. The planar measurement for the evaluation of Gamma Index (DD 2% / DTA 2 mm, the passing rate of 90%) carried out at 100 cm SAD with the homogeneous and inhomogeneous material at a depth of 1.5 cm, 5 cm, and 10 cm, respectively. We obtained deviation average value of GI between CGR 0.2 cm and 0.4 cm using the homogeneous material on FBCT and CBCT modality ≤1.46% and ≤ 1:13%, respectively. As well as the material inhomogeneous deviation of ≤ 2.54% (FBCT) and ≤ 1.74% (CBCT). The deviation of the average GI value between FBCT with CBCT with CGR 0.2 cm respectively ≤ 1.95% (homogeneous) and ≤ 2.36% (inhomogeneous). Finally, the deviation of the average GI value between homogeneous and equivalent of homogeneous material is ≤ 0.80%. From the results obtained, that the Gamma Index can be influenced by the number of segments, modalities of CT, calibration of CT numbers, calculation grid resolution and depth of material., TheseStudieshavebeencarriedouttoevaluatetheeffectofahomogeneousandinhomogeneousmaterialonIMRTTechnique(IntensityModulatedRadiotherapy)usingFanBeamCT(FBCT)andConeBeamCT(CBCT)fortheGammaIndex(GI).ThePhillipsPinnacletreatmentplanwasusedtoreplan5patientsonrightsideoflungcancer.Photon6MVwasappliedtothistechniquewith30segments,50segments,and70segments,repectively.UsingCalculationGridResolution(CGR)0.2cmand0.4cmforresolutioninthecalculationofthedose.AswellasthecalibrationofCTnumbers(CCN)FBCT,CBCT,andthelineardensityareusedasacorrectionCTnumber.TheplanarmeasurementfortheevaluationofGammaIndex(DD2%/DTA2mm,thepassingrateof90%)carriedoutat100cmSADwiththehomogeneousandinhomogeneousmaterialatadepthof1.5cm,5cm,and10cm,respectively.WeobtaineddeviationaveragevalueofGIbetweenCGR0.2cmand0.4cmusingthehomogeneousmaterialonFBCTandCBCTmodality≤1.46%and≤1:13%,respectively.Aswellasthematerialinhomogeneousdeviationof≤2.54%(FBCT)and≤1.74%(CBCT).ThedeviationoftheaverageGIvaluebetweenFBCTwithCBCTwithCGR0.2cmrespectively≤1.95%(homogeneous)and≤2.36%(inhomogeneous).Finally,thedeviationoftheaverageGIvaluebetweenhomogeneousandequivalentofhomogeneousmaterialis≤0.80%.Fromtheresultsobtained,thattheGammaIndexcanbeinfluencedbythenumberofsegments,modalitiesofCT,calibrationofCTnumbers,calculationgridresolutionanddepthofmaterial.Keywords:CalculationGridResolution,CalibrationofCTNumbers,Cone]"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2016
T45207